Metallic Systems TYPE SPTC

Similar documents
TECHNICAL DATASHEET. Weatherproof LED luminaire ZALEDA EVOL II. 85,000 h product life. General characteristics. Mounting accessories.

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX Standard Plus. 50,000 h product life IK C. Applications recommendation

TECHNICAL DATASHEET. Weatherproof LED luminaire DUNA FLEX High Efficiency. 70,000 h product life IK C. Applications recommendation

P17 Tempra Pro plugs, mobile sockets, fixed sockets, surface mounting sockets and appliance inlets - IP 66/67-63 A A

HYPRA Prisinter 16/32/63 A

Small on price, big on boot

Issue One. Chemical Compatibility Guide

P17 combined units LIMOGES Cedex Telephone : Fax : Cat. No.(s) : 566 XX XX XX XX

Selection of DODGE E-Z KLEEN Polymer and Stainless Steel Housed Ball Bearings. P = (X x F R ) + (Y x F A ) F A C o

Strength, resilience, rigidity - these are all attributes needed to combat arduous and aggressive conditions. Tufflite has them all.

Flexible Conduit Systems for Critical Power & Data Cable Protection

How to Use the Chemical Compatibility Chart. Vials and Closures >> Chemical Compatibility Chart

Adaptaflex Metallic & Specialty Flexible Conduit Systems

P17 plugs, mobile sockets and surface-mounting sockets «New range 16 and 32 A»

Replacement Tubes for Gillian Gas Detection Pumps

2. RANGE. RAL 7035 Cabinets Vertical version (external dimensions in mm) Square version (external dimensions in mm) Supplied with plain plate (2) (1)

Q-Duct wiring duct. Q-Duct Wiring duct. Catalog number explanation QD 100 X 100 S G

Marina Cabinets LIMOGES Cedex Telephone: Fax:

Chemical Resistance of Arnitel

TANK LINING RESISTANCE GUIDE I-19

VAL QTY

Application Data Sheet. Chemical Compatibility Chart. IND-AS EN-01 (May, 2014) Metals Plastics Seals KEY. Good. Fair. Ethylene Propylene.

VentureClad Insulation Jacketing Tapes 1577 Series

TEST REPORT: CHM12-01-LSM

Halogen Free, Flame-retardant Polyether based TPU

Information. Mechanical. Electrical. Chemical. Conversions & Calculations

Product Information S/PA

We offer two fire retardant (FR) resins for strut systems: polyester and vinyl ester. Both resins are ideal for corrosive environments.

Hose and Fitting Edition

TECHNICAL MANUAL COMPRESSION FITTINGS

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

Pressure switch FF 4 Approval acc. to ATEX EN For mining and chemistry

High pressure industrial ball valves

Swivel Joints Flexmaster Joints Part Number NH NH NH NH NH NK NK

KLINGER top-chem A milestone in PTFE gasketing KLINGERsoft-chem

Colorimetric Gas Detector Tube System US Dollar Price List

Section 3 - Chemical/Environmental Resistance Part 1 - XR-5 Fluid Resistance Guidelines

SHIELD-FLEX EMI / RFI Shielded Conduit

Dynaform Fiberglass Structural Shapes. Design Guide. High Performance Composite Solutions. Corrosion Resistant. Fire Retardant.

material handling optibelt rr / rr Plus / hrr

KLINGER KGS. Rubber-Metal-Gaskets Safe sealing of gases and liquids

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

Physical properties of PET resins. 1. Intrinsic Viscosity (IV)

SHIELD-FLEX EMI / RFI Shielded Conduit

DURA SLAB PULTRUDED TECHNICAL SPECIFICATIONS January 2014

Control pressure switch series FF 4

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

FR PVC COATED RAINWEAR

16/32/63A - IP44 plugs, mobile sockets, socket inlets and appliance inlets

Chemical Resistance Chart

Neopolen. Contents. 1. Product 1.1 Description 1.2 Forms supplied 1.3 Delivery, Conveying, Storage

Plexo composable plate supports and boxes

KLINGER-KGS Rubber- Metal-Gasket

ENERGY. Solar Cables

Catalog June Mounted Bearings

Polycarbonate & Laminate Half Trays

Chemical Protective Clothing Standards Update. Ulf Nyström

Be prepared with Lutz. Safety is our concern

Pressure switch FF up to 250 bar, ample wiring room, easy to adjust high repeatability of set switchpoints, easily read scale

High Temperature Marker Tag

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

International Quality Assurance Exchange Program Schedule. Fuel Month Number Type Dispatch Date Closing Date

Safety Products brochure 11 Int INDEX. Exhaust Filters 2. Air Inlet Valve 5. GL45 Caps 6. DIN50 Caps 8. GL38 Caps 10. DIN60 Caps 11.

Tubing Size 1/8-1/4 1/8 Flow Chrome Brass 20CB Series Couplings

Grommet TET. Cable glands. Basic Data. Application. Press the grommet into the hole.

ANALYTICAL RESULTS. PWS ID/Name: ROCKHOUSE MOUNTAIN - CONWAY Report Date: 03/29/2016

NO: AC.2006.CT.01 شرکت کامپوزیت آسیاآسیا(سهامی تولیدکننده انواع قطعات کامپوزیتی گریتینگ و سینی کابل)

150 Series Brass Horizontal Float Valve. Technical Information

EN WORKMASTER HAZMAX BOOTS. Certification

Fibreglass Reinforced Plastic

MM PISTON PUMP

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM

Synonym(s) ) Chlorine, liquefied/gas. Ammonia, Gasoline, natural 7300 (gasoline) Hydrogen gas. Phosgene

60PP Series Couplings

Ducting & Ventilation Components

Dräger CMS Chip Measurement System

The Air Logic Division of Fred Knapp

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Dräger CMS. Dräger CMS: Highly accurate and easy to use. Dräger CMS Chip: Miniaturised Dräger-Tubes.

Delta Intercontinental Pte Ltd Tel : Fax: Woodlands Industrial Park E1, #

HelaGuard. Non-Metallic Conduit & Fittings

MM PISTON PUMP

KML KML. Socketless cast iron system for aggressive waste water from kitchens and laboratories. Product information

QCB Thermoplastic Bearing Units

General applications Chemical plant, oil refinery, power plant, steam, Dowtherm, fused alkali, fuel oil and gas

SERIE 2T SERIES 3T ASTM - A216 WCB, A216WCC, A351 CF8, A351 CF8M, A352 LCB, A351 CN7M, A105N, NO. Part Name Material

Cable Management Solutions. HelaGuard. Non-Metallic Conduits and Fittings

TECHNICAL INFORMATION

FILTRATION SYSTEMS CARBOX PHARMACEUTICAL HOODS ACTIVATED CHARCOAL FILTERS

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

Double Containment Piping Systems Kendall Group Tech Summit Presentation

ZHPCG CK0226 POWER CABLE WIRE & CABLE

Engineered installation products Solutions for control panel applications

MITSUBISHI ELECTRIC E1032. Installation manual. English MA

EF 8 EF 9. Company name Idemitsu Nippon Oil Cosmo Oil Showa Shell Sekiyu TonenGeneral Sekiyu Japan Energy

Strainer BOA-S PN 6/16/25 DN Type Series Booklet

Module 6: Chemical Resistance

RPL "Raised Panel Label"

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

Transcription:

CONDUIT 27/01/2009 Technical Data Sheet Page No. 1 Applications Hospitals External Safety Critical Area Fittings IP54 SPB Fittings type A & B Characteristics Very High UV Resistance High Flexibility Medium Fatigue Life High Mechanical High Abrasion Resistance Self Extinguishing High EMI Approvals CE LVD IEC61386 Material Operating Temperature: Galvanised Steel PVC Covering Tinned Copper Braid Static: 15 C +70 C Moving: 5 C +90 C Part No. NC Size NW Pitch (B) Inside Diameter (A) Outside Diameter Dimensions Reel Length (C) Min Bend Radius Colour SPTC 6.8.0 SPTC12 13.3 14.0 SPTC16 16 13.0 17.5 30 SPTC20 20 16.9 21.5 35 SPTC 21.4 26.0 55 SPTC32 32 28.1 34.0 60 SPTC40 40 37.7 43.6 80 SPTC50 50 48.4 56.0 90 Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom Tel: +44(0)1675 468222 Fax: +44(0)1675 464930 email: sales@adaptaflex.co.uk www.adaptaflex.com

CONDUIT 27/01/2009 Technical Data Sheet Page No. 2 Mechanical Properties Method/Standards Requirements Value Crush Strength @ 23 C IEC613861 <% reduction in diameter after load N Crush Strength @ 23 C % Crush, instantaneous value 2200N Impact Strength @ 23 C IEC613861 No Cracks diameter torpedo gauged 20J (Class 5) Impact Strength @ C IEC613861 No Cracks diameter torpedo gauged 6J Tensile Strength @ 23 C IEC613861 With A Type Fittings 00N Tensile Strength @ 23 C Ultimate pullout of Atype fitting 1450N Static Bend Radius @ 23 C 45mm Dynamic Bend radius @ 5 C IEC613862.3 5000 cycles @ 50mm Pass Thermal Properties Method/Standards Requirements Value Minimum Temperature Static Permanent use 15 C Maximum Temperature Static Permanent use +70 C Minimum Temperature Dynamic IEC613862.3 5000 cycles 5 C Maximum Temperature Dynamic IEC613862.3 5000 cycles 90 C Maximum Short Term static 3000 Hours Maximum 90 C Flammability, Smoke and Toxicity (FST) Performance Method/Standard Requirement Result Unit Halogen Free No Phosphorus Free Yes Sulphur Free Yes Oxygen Index ISO 4589 % Oxygen to support combustion 28 % Glow Wire rating IEC 60695 No ignition, extinguish within 2 s 850 C Flammability UL94 Vertical (V0, V2) or Horizontal (HB) V0 Flammability IEC613861 1kW burner @ 45 Pass Pass/Fail Pre test Conditions Duration 168 (Hours) Standard EN50086/IEC61386 Temperature 23 ( 0 C) Relative Humidity 50 (%) Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom Tel: +44(0)1675 468222 Fax: +44(0)1675 464930 email: sales@adaptaflex.co.uk www.adaptaflex.com

CONDUIT 27/01/2009 Technical Data Sheet Page No. 3 EMC Screening The graph below shows the results of SPTC20 screened conduit, with its appropriate fittings, tested by ERA Technology ti IEC 600962:1993 Radio Frequency Cables Part 1 Tests measured attenuation in decibels (db) over the frequency range covered by the EMC directive. 0.1 to 00MHz. Overbraiding Details Tinned copper wire OD 0.28 0.30mm. 32 carriers, 8 wires per carrier. Minimum 90% braid coverage. EMI Screening effectiveness of SPTC conduit 1 0 90 80 Attenuation (db) 70 60 50 40 30 0.1 1 0 00 Frequency (MHz) Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom Tel: +44(0)1675 468222 Fax: +44(0)1675 464930 email: sales@adaptaflex.co.uk www.adaptaflex.com

CONDUIT 27/01/2009 Technical Data Sheet Page No. 4 Chemical Properties Astm No.1 Astm No.2 Astm No.3 Acetic Acid (%) Acetone Aluminium Chloride Aniline Benzaldehyde Benzene Carbon tetrachloride Chlorine water Chloroform Citric Acid Copper Sulphate Cresol Diesel oil Diethylamine Ethanol Ether Ethylamine Ethylene Glycol Ethyl Ethanoate Freon 32 Hydrochloric Acid (%) Hydrochloric Acid (36%) Hydrogen Peroxide (35%) Hydrogen Peroxide (87%) Lactic Acid Lubricating oil Suitable Limited Suitability Methanol Methyl Bromide MEK Nitric Acid (%) Nitric Acid (70%) Oxalic Acid Ozone (Gas) Paraffin oil Petrol Phenol Sea Water Silver Nitrate Skydrol Sodium Chloride Sodium Hydroxide (%) Sodium Hydroxide (60%) Sulphur Dioxide (Gas) Sulphuric Acid (%) Sulphuric Acid (70%) Toluene Transformer Oil 1,1,1Trichloroethane Trichloroethylene Turpentine Vegetable Oil Vinyl Acetate Water White Spirit Zinc Chloride The information above is given as a guide only and is based on published technical data and experience. The chemical resistance of the above products is dependant on factors such as chemical exposure, concentration of the chemical and temperature. The above chemicals are valid for a temperature of 23 C. Use of the above table is at the users own discretion and risk. Those using it must satisfy themselves that their application presents no health and safety risks. The end user should assess compatibility with their application and contact Adaptaflex for further information. IEC 61386 CLASSIFICATION Fitting Compression Impact Min temp Max temp Bending Electrical IP Solids IP Water Corrosion Tensile SPTC SPB 4 4 2 2 4 3 5 4 4 NonFlame Propagation 1 Suspended Load 5 Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom Tel: +44(0)1675 468222 Fax: +44(0)1675 464930 email: sales@adaptaflex.co.uk www.adaptaflex.com

CONDUIT 27/01/2009 Technical Data Sheet Page No. 5 Dimension charts for associated fittings TYPE A TYPE B Adaptaflex, Station Road, Coleshill, B46 1HT United Kingdom Tel: +44(0)1675 468222 Fax: +44(0)1675 464930 email: sales@adaptaflex.co.uk www.adaptaflex.com