Bruker BioSpin MATCH. Multiple Adjustable Tube Clamp Holder User Manual - Version 005. NMR Solutions. think forward

Similar documents
Bruker BioSpin NMR CASE. Installation Manual. Version. NMR Spectroscopy. think forward

Bruker BioSpin NMR CASE. Troubleshooting Guide. Version. NMR Spectroscopy. think forward

minispec Plus Release Letter Innovation with Integrity Version 001 AIC

MAS Rotor Test Station

Agilent G5632 Valve Kit Instructions

Agilent 210/218 - Isocratic Pump

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent 210/218 - Binary Pump

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

HV angle valve with single acting pneumatic actuator and closing spring (NC)

BOHLENDER GmbH Phone: +49(0)9346 / Fax: +49(0)9346 / Internet:

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Agilent G4239C Valve Kit - Instructions

Hydraulic Rotary Hammer Drill

Chapter 5. Caring for your pipette. Step 1 Check the records

Agilent SD-1 Purification System ml/min

Register your instrument! HeatSealer S100. Operating manual

User manual. AGRETO Soil Compaction Tester AGRETO electronics GmbH

Rectangular Door L-VAT with pneumatic actuator double acting

Heated Perfusion Cube

Agilent 1260 Infinity Manual Injector

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Never charge the batteries with a charger other than that supplied by the manufacturer.

Self-Adjusting Clutch (SAC) Technology Special tools / User instructions

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

OPERATIONS MANUAL CR Thermoreactor

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Motor Valve MV-7/IMV-7

MityFlex Peristaltic Pump

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Shock Absorber Rebuild Manual

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

GE Healthcare. Valve INV-917. Instructions

SensoLyt 700 SensoLyt 700 SW

MPP 910 IDS MPP 930 IDS

TX21U Temperature/Humidity Sensor. Instruction Manual

Agilent 1200 Series Manual Injector

CRT-90. COLLAR REMOVING TOOL For 90 mm Collars INSTALLATION AND OPERATION INSTRUCTION MANUAL

WPS02 Waste powder conveying with BIG-BAG station

Agilent G4236A 2D-LC Valve Installation Guide

CONTACTS RELAY TESTER 66249

Mini UHV gate valve with manual actuator with pneumatic actuator

COSASCO HYDRAULIC ACCESS FITTING User Manual

OPERATING INSTRUCTION

Application cup for OptiFlex 2 GM03 manual powder gun

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

Agilent InfinityLab Quick Change Valve G4237A

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC)

Series 900 Slitter Shaft

MODEL 905V OPERATING INSTRUCTIONS

CORDLESS TACKER MODEL NO: CCT48 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0414

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Assembly Instructions

Passive Check Valve Installation Instructions for H-Class Systems / Revision A Copyright Waters Corporation 2014 All rights reserved

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Hard Seat Fluid Pressure Regulator

Refinery Supply Company, Inc.

Dilutor Module for TriPlus RSH

2 ADAPTERS. Bushing / Connecting. Glass Bushing Adapters. Straight Connecting Adapters. PTFE Bushing Adapters. Offset Connecting Adapters

Operating Manual COST CONTROL - POWER CONSUMPTION MONITOR

Supplementary instructions. Air cooling - FIBERTRAC 31. Active air cooling system for radiation-based sensors. Document ID: 50339

1 Operating instructions for rail-mounted stand holder, variable

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

User Manual COSASCO HYDRAULIC ACCESS FITTING

Pressure relief valve

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Data sheet. D-2011/05/ Date: 07/2013. Type TK4 CNG. CNG Fuelling Nozzle. for cars. WEH - We Engineer Hightech

SPARK PLUG CLEANING KIT OPERATING MANUAL

SEBA HYDROMETRIE, User Manual KLL

Data sheet. D-2011/05/ Date: 07/2013. Type TK1 CNG. CNG Fuelling Nozzle. for time filling of cars. WEH - We Engineer Hightech

Operating Instructions

Diaphragm Pumps for Air, Gases and Vapours LABOPORT Mini Diaphragm Vacuum Pumps and Compressors

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Plunger Heads Use and Maintenance Manual

GENERAL WARNING. General instructions. Technical assistance. Doseuro S.r.l. Liability

Industrial flue gas probes. Instruction manual

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Product Parts Information. Manual Chain Hoist. KM Series. Save These Instructions. Form Edition 2 December Ingersoll-Rand, plc

Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

TABLE OF CONTENTS DESCRIPTION. Safety Instructions & Safety Sign Locations Operating Instructions Assembly Instructions...

Elcometer Motorised Film Applicator

HD4170 SETUP & OPERATOR MANUAL. Performance Design Inc East Braniff St. Boise, Idaho 83716

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

0-800 psi Carbide Seat Fluid Pressure Regulator

GLENCO Syringes. Spectrum Double Action Syringes. Spectrum Double Action Removable Needle Micro Syringes Glenco Series 19913

Supplementary instructions. Air cooling - FIBERTRAC 31 with Conduit tube connection. Active air cooling system for radiation-based sensors

MMP & DMP. Manual Microsyringe Pumps INSTRUCTION MANUAL. Serial No. World Precision Instruments

INSTALLATION INSTRUCTIONS PART NUMBER C (Gun Metal Grey Finish)

Transcription:

Bruker BioSpin MATCH Multiple Adjustable Tube Clamp Holder User Manual - Version 005 think forward NMR Solutions

The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken as a result of use of this manual. BRUKER BIOSPIN accepts no liability for any mistakes contained in the manual, leading to coincidental damage, whether during installation or operation of the instrument. Unauthorized reproduction of manual contents, without written permission from the publishers, or translation into another language, either in full or in part, is forbidden. This manual was written by Martin Hofmann Edited and desktop published by: Stanley J. Niles January 8, 2008: Bruker Biospin GmbH Rheinstetten, Germany P/N: H9846 DWG-Nr.: 2007-12-04 005 For further technical assistance on the MATCH holder, please do not hesitate to contact your nearest BRUKER dealer or contact us directly at: BRUKER BioSpin GMBH am Silberstreifen D-76287 Rheinstetten Germany Phone: + 49 721 5161 0 FAX: + 49 721 5171 01 E-mail: nmr@bruker.de Internet: www.bruker.com

Contents Contents... 3 1 Introduction... 5 1.1 Disclaimer... 5 1.2 Safety Issues... 6 1.3 Warnings and Notes... 6 1.4 Contact for Additional Technical Assistance... 6 2 System Characteristics... 7 2.1 Characteristics of the MATCH System... 7 3 Preparation & Handling... 9 3.1 Preparing and Mounting the Clamp... 9 3.2 Sample Handling... 10 3.3 Inserting the Sample Tube... 10 3.4 Removing an NMR Tube... 11 3.5 General Handling Instructions... 11 4 Ordering Information & Accessories... 13 4.1 Ordering Information... 13 4.2 Accessories... 14 4.3 Product Availability... 14 User Manual Version 005 BRUKER BIOSPIN 3

Contents 4 BRUKER BIOSPIN User Manual Version 005

Introduction 1 1 The Bruker BioSpin Multiple Adjustable Tube Clamp Holder (MATCH TM ) system provides you with an easy and cost-efficient means to optimize the signal-to-noise ration of each of your samples. By matching the NMR tube diameter to the size of your sample, you will be able to place most of your sample in the active volume of your NMR coil. This leads to an enhanced signal detection compared to diluting the same sample quantity in a larger tube. The Bruker MATCH system allows you to choose from a variety of tube diameters, ranging from 1.0 to 5.0 mm, thus allowing you to tailor your experiment to the amount of sample available. The MATCH allows you to do this with a single tool and short tubes, i.e. no need to acquire multiple spinner sizes, nor to buy expensive NMR tubes of different diameters. In addition to its use for small sample quantities, the MATCH system can be used to counteract the losses in sensitivity of salty samples. In such samples the limits RF penetration can be counteracted by choosing a smaller diameter. Disclaimer 1.1 The MATCH system should only be used for its intended purpose as described in this manual. Use of the unit for any purpose other than that for which it is intended is taken only at the users own risk and invalidates any and all manufacturer warranties. Read this manual before using the MATCH. Pay particular attention to any safety related information. The MATCH TM device is protected: US Patent US 6,741,079 B2 UK Patent GB 2381316 German Patent DE 101 30 283 C1 User Manual Version 005 BRUKER BIOSPIN 5 (15)

Introduction Safety Issues 1.2 The MATCH system allows convenient and safe handling of samples within a laboratory environment if standard laboratory operating procedures and established laboratory practices are followed. Be sure to review all established policies and procedures for your laboratory before using the MATCH system. Warnings and Notes 1.3 There are two types of information notices used in this manual. These notices highlight important information or warn the user of a potentially dangerous situation. The following notices will have the same level of importance throughout this manual. Note: Indicates important information or helpful hints WARNING: Indicates the possibility of severe personal injury, loss of life or equipment damage if the instructions are not followed. Contact for Additional Technical Assistance 1.4 For further technical assistance on the BPSU36-2 unit, please do not hesitate to contact your nearest BRUKER dealer or contact us directly at: BRUKER BioSpin GMBH am Silberstreifen D-76287 Rheinstetten Germany Phone: + 49 721 5161 0 FAX: + 49 721 5171 01 E-mail: nmr@bruker.de Internet: www.bruker.com 6 (15) BRUKER BIOSPIN User Manual Version 005

System Characteristics 2 2 Characteristics of the MATCH System 2.1 This chapter lists some of the important characteristics of "The MATCH System": The MATCH device is a holder for 100 mm long NMR sample tubes with diameters ranging from micro tubes up to 5 mm NMR tubes (see "Ordering Information" on page 13). The MATCH device fits into a standard 10 mm BRUKER spinner. The MATCH insert for the 10 mm Bruker spinner is suited for all non-spinning applications. The handling of 100 mm NMR tubes is far easier than standard 7 (180 mm) long tubes. e.g. long pipettes are not required to fill the sample tube. The insert can be precisely adjusted to an insertion depth of 9-21 mm. After initial adjustment the tubes are automatically set to this depth. One spinner and holder can be used for a wide variety of NMR tube sizes. The holder is fitted with an easily exchangeable clamp that is adapted to the diameter of the sample tube. The clamps are color coded according to NMR tube diameter (see "Ordering Information" on page 13). NMR tubes can be easily exchanged while the MATCH device is still mounted in the NMR spinner. Depressing the top of the MATCH device will release the tube. The length of the NMR sample tube can be adjusted and smaller tube sizes can be used. This set up is especially useful for optimizing samples of limited volume. MATCH clamps have a chemically inert seal to minimize the evaporation of solvent. User Manual Version 005 BRUKER BIOSPIN 7 (15)

System Characteristics Figure 2.1. The MATCH System 8 (15) BRUKER BIOSPIN User Manual Version 005

Preparation & Handling 3 3 This chapter discusses the proper way to prepare and mount the MATCH insert assembly clamp, information on sample handling, and the proper method of inserting and remove the NMR tube. Preparing and Mounting the Clamp 3.1 Figure 3.1. The MATCH Insert Assembly Insert the holder into a 10 mm NMR spinner. Position the clamp so that it is flush with the lower end of the 10 mm spinner. The adjustment screw may be used to extend the length of the device if necessary. To exchange clamps, press the tip to release the currently mounted clamp. Hold the tip and unscrew the clamp. Keep the tip depressed and mount the new clamp. Screw the new clamp in until you feel resistance (finger tight). Release the tip and the MATCH device is ready to introduce into a 10 mm NMR spinner. User Manual Version 005 BRUKER BIOSPIN 9 (15)

Preparation & Handling Sample Handling 3.2 Use only high quality NMR tubes (see "Ordering Information" on page 13). Fill the sample into the sample tube. Syringes and needles for convenient filling are available (see "Ordering Information" on page 13). Clean the top rim of the sample tube to prevent contamination of the seal inside the holder. Inspect the top rim of the tube for damage. A damaged tube could lead to problems with insertion, positioning and sealing of the sample tube. Inserting the Sample Tube 3.3 Hold the NMR spinner with the tube holder already in place in one hand and press the tip of the holder to open the clamp at the bottom. The NMR tube is very fragile. Hold the tube near the top to prevent breakage. Insert the sample tube completely (approx. 20 mm) into the holder. Release the top of the holder and check that the tube is completely inserted. If the tube not fit tight, a soft pull at the top will help to seat the tube properly. Figure 3.2. Inserting the Sample Tube 10 (15) BRUKER BIOSPIN User Manual Version 005

Removing an NMR Tube Insert the sample and spinner assembly into the depth gauge. Adjust the tube to the proper vertical position with the MATCH adjustment screw. The correct vertical position will depend on the type of NMR probe to be used. Warning: Do not change the vertical position of the NMR tube! Instead change the vertical position of the holder in the spinner. The MATCH insert assembly is made out of the same material as the 10 mm spinner and it is recommended not be used with temperatures above 50 C Warning! Be careful when inserting the tube. Rotate it slightly as you insert it into the clamp. Avoid bending the tube and do not force the tube into the clamp. The tube should slide in without resistance. Do not use tubes with broken rims as this may damage the clamp. In general, tubes with smaller diameters are more fragile. Handle them with care. Use only high quality NMR tubes. To avoid contamination of the tube and spinner, wear gloves, or use a soft, lint free cloth to hold the sample tube. Removing an NMR Tube 3.4 To release the NMR tube, press the tip of the MATCH device and pull the tube straight out of the clamp. General Handling Instructions 3.5 You must insert the sample tube completely into the holder so that the open top of the sample tube is pressed against the seal inside the holder. You must insert the sample tube completely into the holder for best reproducibility of the vertical positioning of the sample tube. If this is not done, it is necessary to check the positioning manually with the sample depth gauge for each sample. Use only high quality sample tubes. Such tubes are manufactured to tight specifications and each tube will have a well defined outer diameter (OD) and length. This ensures that they will fit always perfectly in the clamp and maintain User Manual Version 005 BRUKER BIOSPIN 11 (15)

Preparation & Handling the correct vertical position. High quality tubes also have a smooth top rim that will make tube insertion easier as well as prevent scratches inside the clamps. 12 (15) BRUKER BIOSPIN User Manual Version 005

Ordering Information & Accessories 4 4 Ordering Information 4.1 Table 4.1. Ordering Information Tube ID Clamp Color Code Sample Volume for Filling Height Bruker Order Number 35 mm 40 mm MATCH Insert Spare Clamps NMR Tubes 100 mm (mm) (µl) 1 piece/pack 1 piece/pack 10 pieces/pack 1.0** black 12 14 AH1130 Var. 10 AH1140 Var. 10 AH1160 Var. 10 1.7** white 45 50 AH1130 Var. 17 AH1140 Var. 17 AH1160 Var. 17 2.0 yellow 70 80 AH1130 Var. 20 AH1140 Var. 20 AH1160 Var. 20 2.5 red 120 140 AH1130 Var. 25 AH1140 Var. 25 AH1160 Var. 25 3.0 green 160 190 AH1130 Var. 30 AH1140 Var. 30 AH1160 Var. 30 4.0 blue 310 360 AH1130 Var. 40 AH1140 Var. 40 AH1160 Var. 40 4.25 white 370 430 AH1130 Var. 42 AH1140 Var. 42 AH1160 Var. 42 5.0 black 490 560 AH1130 Var. 50 AH1140 Var. 50 AH1160 Var. 50 ** Not suited for dedicated Shuttle NMR probes! User Manual Version 005 BRUKER BIOSPIN 13 (15)

Ordering Information & Accessories Accessories 4.2 Table 4.2. List of Accessories Part Number Description Z5293 AH1150 10 mm Spinner POM 100x Disposable Syringe and 100x Needles (suited for 2.0 to 5.0 mm tubes) 88070 Disposable Glass Syringe with Reservoir (suited for 1.0 to 4.0 mm tubes) H1381 Barcode Socket for MATCH Product Availability 4.3 Currently the recommended NMR tubes are available from: Table 4.3. Product Availability Company Bruker Biospin Hilgenberg GmbH Norell Inc. Contact Information Contact your local sales office. www.hilgenberg-gmbh.de www.nmrtubes.com 14 (15) BRUKER BIOSPIN User Manual Version 005

Notes: User Manual Version 005 BRUKER BIOSPIN 15 (15)

Bruker BioSpin your solution partner Bruker BioSpin provides a world class, market-leading range of analysis solutions for your life and materials science needs Bruker BioSpin Group Bruker BioSpin H9846 info@bruker-biospin.com www.bruker-biospin.com