Lahmeyer Compactstation. Type NDV400

Similar documents
Lahmeyer Compactstation. Type WPS2500

Lahmeyer-Compactstation

Lahmeyer-Compacttransformer

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

UniGear. Technical Guide

LAHMEYER Compact-transformer-substation

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

COMPACT SUBSTATION GUIDE

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Cable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

NH-Fuse system Low voltage

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

NEXT STEP B) SAFETY :

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

TGK Prefabricated Substation Technical Data

ormaset-m PREFABRICATED METALLIC TRANSFORMER SUBSTATION

Modular medium-voltage switchgear. NorMax

CAST RESIN TRANSFORMERS

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

PIX-H Metal-clad switchgear up to 17.5kV

Low-voltage switchgear MNS Light W. Installation, handling and operation. ABB LV Systems

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Manual for installation and operation HB 602/14 en. ZX2 Gas-insulated medium voltage switchgear

ormaset-m Prefabricated metallic transformer substation

PIX. Operation - Replacement of Fuses Replacement of Voltage Transformers Technical manual. Medium Voltage Distribution

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Manual for installation and operation HB 602/05 en. ZX2 Gas-insulated medium voltage switchgear

Power systems Protection course

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

photovoltaic NEW Safe product solutions conforming to standards for Industrial Electrical Power Distribution Systems with extended product range

Unified requirements for systems with voltages above 1 kv up to 15 kv

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

with Vacuum Circuit Breaker HAF

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

NS Feeder pillar up to 3200A

Key features. DESIGNS: - Conservator type - Hermetically sealed

SENTRON Switching and Protection Devices Switch Disconnectors

MINIATURE CIRCUIT BREAKER

Domae. The right solution for distribution boards

ENYSTAR Load Centers up to 250 A

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Energy Australia Chamber Substation indoor switchgear. installation,operation and maintenance instructions version 1.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

LV Capacitor CLMD03 Power Module Instruction manual

CPG.0 Single busbar gas-insulated cubicles

Vertical fuse disconnects

CBGS-0. Medium voltage distribution

TKS-CS OPERATING INSTRUCTIONS. Compact Station for Connecting the Solar Inverter to Medium Voltage. AEG Power Solutions GmbH, Warstein-Belecke

FUSES. Safety through quality

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Benefits, typical uses

UniSec Operation and maintenance manual

TECHNICAL DATA SPECIFICATIONS

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

Power IT Air Insulated Cubicle Uniswitch

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Vertical fuse disconnects

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Low Voltage A GE Power Controls Company. General catalogue

OPERATING INSTRUCTIONS

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

B kv T&D GAS INSULATED SWITCHGEAR

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

3NP1 Fuse Switch Disconnectors up to 630 A

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

GHA. Medium-voltage switchgear. Gas-insulated switchgear 40.5 kv ( 40 ka) for single and double busbar panels. Assembly Instructions

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

NXPLUS C Single busbar. Maintenance-free for lifetime

3VU13, 3VU16 Circuit-Breakers

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

SWITCHBOARDS (LV and MV)

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

SM6. instructions for use. SM cubicle. MV distribution factory built assemblies at your service. Anglais

31-SDMS-01 REV. 03 SPECIFICATIONS FOR

Original Manual 2CCC444010M0201 Rev. 1.0, Date of Release: 02/2016. Remote Power Panel Assembly instructions

Low Voltage Main Distribution Board

ACCESSORIES FOR SZE2 CABINETS

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Transcription:

Operation- and maintenance manual Lahmeyer Doc.-No.: T152A20.1 SBG GmbH phone: +49 (0) 37600/83-197 Ohmstrasse 1 phone: +49 (0) 37600/83-226 08496 Neumark phone: +49 (0) 37600/83-253 Germany Fax: +49 (0) 37600/83-250 compactstation@sgb-neumark.de www.sgb-smit.com version: 03/2016 Subject to technical changes 1

Content 1 Safety instructions 2 Use and technical instructions Use Premises / advices for dimensioning Torque precepts Regulations, standards 3 Substation-housing Construction Material and surface treatment Connecting elements Doors, locks Protection degree Lifting Earthing Lighting 4 MV-switchgear 5 Transformer Transformer compartment Installation or replacement of a transformer 6 LV-distribution panel General Protection against contact Notes to main equipment 7 Earthing 8 Transport, installation and connection Installation Cable connections, MV- and LV-side Transport restraint 9 Maintenance and care Care Maintenance Adjustment of doors Annex: Confirmation DGUV regulation 3 Risk assessment version: 03/2016 Subject to technical changes 2

1 Safety instructions Please read these instructions before using the device and store them. Installation, initial start-up and operation of the substation have to be done by qualified personnel, trained in use of MV-switchgears, transformers, LV-panels, and in accordance with the appropriate regulations and standards. Following safety rules acc. to DIN VDE 0105 shall be observed: 1) Disconnect mains! 2) Prevent reconnection! 3) Test for absence of harmful voltages! 4) Ground and short circuit! 5) Cover or close off nearby live parts! 2 Use and technical instructions The compactsubstation type NDV400 is used as network and customer substation and is IAC-qualified with certain MV-switchgears IAC-AB 20kA, 1s. Requirements for proper and safe application: adequate transport and properly loading and unloading, as well as storage professional installation and initial start-up carefully operation and service by qualified personnel take notice of this manual compliance of safety- and operation instructions on site, regulations and standards of the utility or grid operator, as well as national standards Please note, according to EN 62271-202, that in case of installation inside a substation the transformer must not be steady operated with nominal power. The transformer has to be operated with reduced power depending on ambient conditions and the housing class of the substation. Equally, the LV-switchgears are subject to a reduction of the nominal current depending on ambient conditions. version: 03/2016 Subject to technical changes 3

Torque precepts for screw connections The given values apply all connections of housing and other parts, as far as no other precepts of the manufacturer are specified. Steel screw, zinced Stainless steel screw A2-70 setscrew metric coarse pitch DIN 13, part 13 strength class: 8.8 setscrew metric coarse pitch DIN 13, part 13 strength class: 70 Dimension Torque M A in Nm Torque M A in Nm M5 5,9 4,2 M6 10,0 7,3 M8 25,0 17,5 M10 49,0 35,0 M12 85,0 60,0 M14 135,0 94,0 M16 210,0 144,0 Torque precepts for cooper busbar- and cable lug connections The given values apply all connections of copper busbars and cable lugs, as far as no other precepts of the manufacturer are specified. Steel screw, zinced setscrew metric coarse pitch DIN 13, part 13 acc. to SGB FV 8001 Dimension Torque M A in Nm M8 25,0 M10 40,0 M12 60,0 M16 80,0 Please note the specific torques for busbars mounted on MV-instrument transformers! version: 03/2016 Subject to technical changes 4

The substation follows the technical rules mentioned below: DIN VDE 1000 DIN VDE 0101 DIN VDE 0105-100 EN 60071-1 (VDE 0111 part 1) EN 60071-2 (VDE 0111 part 2) EN 60445 (VDE 0197) DIN EN 60947-1 (VDE 0660-100) CENELEC HD 603 S1/A3 CENELEC HD 620 S1/A3 DIN EN 61442 (VDE 0278-442) EN 60529 (VDE 0470 part 1) EN 60076-10 (VDE 0532 part 76-10) DIN VDE 0660 part 514 DIN EN 62271 part 1 (VDE 0671-1) EN 62271 part 202 EN 61230 (VDE 0683 part 100) DIN EN ISO 12944 DIN 4102 DIN EN 14598 VDE 0100 DGUV order 3 General guiding principles responsible to security of technical products Heavy current gears with rated voltages over 1 kv Operation of heavy current plants Insulation co-ordination - Part 1: Definitions, principles and rules Insulation co-ordination - Part 2: Application guide Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals and conductor terminations Low-voltage switchgear and controlgear Part 1: General rules Heavy current cables; part 603: Distribution cables of rated voltage U0/U 0,6/1 kv Heavy current cables; part 620: Distribution cables with extruded insulation for rated voltages from 3,6/6 (7,2) kv to 20,8/36 (42) kv Test methods for accessories for power cables with rated voltages from 6 kv (Um = 7,2 kv) up to 36 kv (Um = 42 kv) Degrees of protection provided by enclosures (IP code) Power-transformers; part 10: determination of sound levels low voltage-switch device combinations; protection against electic shock; protection against direct accidental touch of dangerous active parts High-voltage switchgear and controlgear Part 1: Common specifications High-voltage switchgear and controlgear - Part 202: High voltage/low voltage prefabricated substation Live working - Portable equipment for earthing or earthing and short-circuiting Paints and varnishes - Corrosion protection of steel structures by protective paint systems Fire behaviour of building materials and building parts Reinforced thermosetting moulding compounds - Specification for Sheet Moulding Compound (SMC) and Bulk Moulding Compound (BMC) standards for low voltage installations Accident prevention regulation: electric installations and means of production The regulations of the water regime law (WHG = Wasserhaushaltsgesetz ) of the Federal Republic of Germany and the regulation concerning electromagnetic fields; 26. BImSchG (federal immission law) are fulfilled. version: 03/2016 Subject to technical changes 5

3 Substation-housing Temperature class = 20 K (with 630kVA) The Compactsubstation type NDV400 is, as all Lahmeyer s, a prefabricated and single-tested unit. It contains Medium-voltage-, transformer- and Low-voltage-compartment. More compartments are possible. Normally the Compactsubstation is ready-to-connect when delivered, meaning that MV- and LVgrid-cable connection works, in some circumstances the insertion of fuses and other on-site-works (e.g. protection device tests), have to be done for operation-readiness. 3.1 The substation housing of type NDV400 is made from bended steel sheet construction and consists of: - base pan with integrated oil collecting pan, welded oil tight, subsequently hot-dip-galvanised and powder-coated; skirting panels are the border to the ground - cross beams from bended steel sheet to carry MV- and LV-equipment, mounted on base pan - easy detachable roof - lockable push plug(s) (access to transformer compartment) - housing, incl. doors and cover panels for MV- and LV-compartment, fully mounted detachable from base pan. 3.2 Material and surface treatment Exterior (in ground): Exterior (above ground): Oil collecting pan: Steel sheet 3 mm, hot-dip galvanised (>750g/m²) and powder-coated (Zinc 70m, coating >70m) skirting panels: Steel sheet, 2 mm, coil galvanised (>225g/m²) 100 % porefree double powder-coating (Zinc 70m, coating >140m) Steel sheet, 2 mm, coil galvanised (>225g/m 2 ) and powdercoated >70m Interior (above ground): Steel sheet, 2 mm, coil galvanised (>225g/m 2 ) Surface treatment: Computer-driven powder-coating-system and 5-Zonepretreatment result in coatings >70 µm. The used powder-paints are free from heavy metal and non-toxic. Zinc and powder paint = highest corrosion-protection Standard colour: Pebble grey (RAL 7032 - structured) 3.3 All connection elements of the housing are corrosion-resistant. N o t i c e : T h e c o a t i n g c a n b e l a c q u e r e d b y t h e u s e r i n o t h e r c o l o u r s, u s i n g s p e c i a l l i q u i d l a c q u e r. T h e g i v e n c o r r o s i o n - p r o t e c t i o n i s n o t a f f e c t e d t h e n. 3.4 The transformer compartment is accessible by push-plug. Doors to other rooms are mounted with three hinges each (adjustment see chapter 9.3). The doors and push-plugs are electrical connected with the housing and part of the earthing concept. They have metal swivelling levers, designated for built-in of profile cylinders. They are protected by rain lids. The cylinders are not part of delivery (unless otherwise stipulated). Lockable opening angles are 90 and 135. version: 03/2016 Subject to technical changes 6

3.5 Degree of protection (IP-Code) closed compartments IP 54 around louvers IP 23D LV-panel IP XXA or higher 3.6 The Compactsubstation type NDV400 can be lifted and transported completely equipped. Lifting lugs are at the base pan. (see lifting and transport drawings) 3.7 All installed metallic parts are connected to the earthing. Main earthing point is the base pan. At LV-side is a PE-busbar in TN-S-system. 3.8 The MV- and LV-compartment can be equipped with lighting, switched by door contact (optional). 4 MV-switchgear The NDV1200-2600 is suitable for use of SF6-gas-insulated switchgears or air-insulated HVmeasuring compartment and HV-fuse-compartment (make SBG). switchgear-type max. configuration make nom. voltage insulation HV-fusecompartment for 2 cables SBG 12 / 24 kv Air 8DJH 3 C + 1T/L Siemens 12 / 24 kv SF6 FBX-C 3 C + 1T/L Schneider Electric MINEX -C with Driescher-ABS 4 C + T/L Driescher Wegberg 12 / 24 kv SF6 12 / 24 kv SF6 SafeRing/SafePlus 3 C + T/L ABB 12 / 24 kv SF6 HV-measuring compartment 3 I-transformers 3 U- transformers SBG 12 / 24 kv Air abbreviations: C - cable feeder T - transformer feeder, with HV-fuses or circuit breaker Depending on condition of the grid, the MV-switchgears can be live, when doors of the MVcompartment of the substation are opened. Air-insulated MV-compartments are closed by an additional door. Working on live, hazardous contactable parts of the installation are allowed only - after establishing a voltage free condition (5 safety rules, see chapter 1) - if made by persons, trained for live works. Gas-insulated MV-switchgears can be tested for abscense of hazardous voltages by integrated voltage detection systems. For air-insulated HV-compartments the use of hand-held voltage detectors is necessary. Please take notice of voltage-range-qualification! version: 03/2016 Subject to technical changes 7

5 Transformer Hermetic-sealed oil-filled transformers 800kVA Dry-type transformers 400kVA max. dimensions transformer L x W x H = 1650 x 900 x 1900 mm (incl. protection range) Transformers stand in the base pan on slip-resistant pads and mounting beams and are fixed without screwing. The transformers will be fastened additionally with belts. Transport restraints: The transformers are fixed with belts. These can be removed, but have to refixed if substation is lifted or transported again. Prefabricated and tested MV-cables made of N2XSY 70mm 2 CU RM / 16mm 2 CU RM, 12/24kV, connect transformer and MV-switchgear. The LV-connection is made by high-flexible, 3kV-isolated cables, type NSGAFÖU, subject to rated power. Installation or replacement of a transformer When installing or replacing a transformer, be careful that MV- and LV-side are disconnected, voltage-free and earthed! The transformer has to be lifted out of the substation. Procedure and advises: Unscrew the two red marked roof-fixing screw in the upper doorframes of MV- and LVcompartment, push the roof approx. 100mm to LV-/MV-longside and detach the roof (by crane is recommended). Demount the IP-protection-wire frame from above transformer compartment, if necessary. Depending on the design version, the IP-protection-wire frame can be part of the roof itself. Open push-plug of the substation. Lift out the transformer, if present. Insert slip-resistant pads (if not present), adjust mounting beams to width of the transformer chassis. Bring in transformer (without rolls), make connections and earthings, affix transport restraints. Notice equipment-specific regulations! Connect and adjust any protective devices, respectively establish function readiness. Test torques of connections and terminals. Mount the IP-protection-wire frame. Attach the roof, snap in place and fix the screws. Close push-plug of the substation. The upper housing can be removed completely after detaching the roof, if necessary. version: 03/2016 Subject to technical changes 8

6 Low-voltage-distribution panel (LVP) The low-voltage-distribution panels of our Lahmeyer s can be individualised to customer requirements within the technical possibilities and limits. In common, the LVPs are built safe for back-of-hand (IPXXA, acc. to VDE 0660-514). Therefore, service and operation of the LVP may be done by electrically qualified persons with personal protection equipment and electrical qualified tools only. Depending on condition of the grid, the LV-panel can be live, when doors of the LV-compartment of the substation are opened. Working on live, hazardous contactable parts of the installation are allowed only - after establishing a voltage free condition (5 safety rules, see chapter 1) - if made by persons, trained for live works. Indicating instruments, fuses and terminals are installed at a separate panel in the LV-room mostly. Other devices can be wall- or top-hat-rail mounted. The N/PEN- and PE-busbars, respectively the main earthing bar, for connection of all earth conductors inside the substation and the outer earth conductor, are placed in the bottom area of the LV-compartment. The cable holders for fixation of the power cables are placed at the cable compartment below. Notes to main devices (depending on technical specification): Circuit breaker (ACB, MCCB) Tripping units have to be adjusted to estimated nominal and short-circuit tripping times and values, before startup operations! LV-fuse-switch-disconnector / LV-strip-type fuse-switch-disconnector have to be equipped with appropriate LV-fuses before startup operations. Mind the selectivity! Risk of burns! Fuses reach very high temperatures during operations! Outgoings (standard width 50/100mm) have to be equipped with appropriate LV-fuses before startup operations. Mind the selectivity! The insertion and extraction of LV-fuses into/out of NH strip-fuseways may be done in a voltage free condition only! The use of strip covers is recommended. We recommend the use of LV-strip-type fuse-switch-disconnectors because of their higher user protection. These can be switched under load, which is live working! When Installation and replacement of outgoings takes place, please pay attention to tightening torques as specified by the manufacturer. Synchronization sockets to synchronize emergency standby power systems for short-time-operations with supply network. Auxiliary-power-inlets to bring in connection cables from any auxiliary power unit Socket(s) for service version: 03/2016 Subject to technical changes 9

Residual current device (RCD) / fuses / miniature circuit breaker (MCB) / motor circuit breaker to protect devices and circuits; partly sealable Uninterruptible power supply (UPS) supply devices, e.g. for protection purposes, with auxiliary power in case of loss of the mains voltage. UPS-installations can be live and supply other devices long time after loss of the mains voltage! Therefore, they have to be disabled before working in the substation takes place! Protection- / detection-devices have to be parametrized, adjusted and tested before startup operations! In some cases they have to be externally supplied (per UPS or auxiliary power unit), e.g. if under voltage circuits exist! Meter boxes for installation of tariff meters, different data modems; sealable Multifunction-devices for display/signalling/storage/logging of type-dependent data (U, I, P, Q etc.). Voltmeter for momentary value display of voltage. Analogue ampere meter for display of momentary/maximum current values. Skales can be changed, depending on type. Plug-in current transformer (CT) meters the electric current for displaying-/tariff metering-/ protection-purposesand can be selectable (type-depending). Quantity of plug-in-ct's (default opening 50x10mm) in standard LVP's with incoming LV-striptype fuse-switch-disconnector: L1, L2 and L3: up to 2 pieces, depending on specification of the substation When equipped with a LV-tariff metering only one more CT is mountable. Mounting is possible on backside of the main/incoming strip-type fuse-switch-disconnector (see right photo), where the access is possible from the transformer compartment, or on separate busbars in the busbar system. Quantity of plug-in-ct's in LVP's with LV-fuse-switchdisconnector or circuit breaker: L1, L2 and L3: up to 2 pieces, depending on specification of the substation Mounting is possible on busbars above or underneath main switch or on separate busbars in the busbar system. version: 03/2016 Subject to technical changes 10

7 Earthing The main earthing busbar can be found in the LV-room. The outer earth conductors have to be connected here (outer earth distance to substation approx. 0,5m - 1,0m). Thereby, all housing parts and the base pan are connected with the main earthing. version: 03/2016 Subject to technical changes 11

version: 03/2016 Subject to technical changes 12

8 Transport, deployment and installation The NDV400 is fabricated ready-to-connect and single-tested, if not negotiated otherwise. Transport, foundation, positioning and installation have to be done on the basis of technical documents as dimension sheet, lifting plan, foundation plan and transport plan. 8.1 Positioning on site: see documentation "set-up conditions" 8.2 Definiton of the excavation depth has to be done under consideration of terrain height and condition, as well as surface water. 8.3 The excavation may have a sustainable ground. Surface irregularities have to be levelled by a planar sand bed. In case of difficult ground conditions, a foundation made from lean concrete is recommended. Under some circumstances, it may be necessary to adjust the doors. A tutorial is given in chapter 9.3. 8.4 The lifting of the substation into the excavation may be done by use of proper lifting equipment. The NDV400 can be lifted fully equipped. Please mind our information in "set-up conditions". 8.5 Please attend for cable connection: Aluminium-conductor-LV-cables may be mounted by cable lug onto bolts only; mounting with steel-frame clamps is not permissible! Steel-frame clamps may not be used for more than one conductor! Pay attention to the tightening torques! 8.6 Cable connection MV-side: Dismount front panel of the base pan Detach cable compartment covers of MV-switchgear according to manufacturer s advices If necessary, dismount front of switchgear mounting frame Loosen front bottom plate (with prepared outcuts) Connect cables and fasten them by use of cable clamps, connect screen wire where required 8.7 Cable connection LV-side: Dismount front panel of the base pan (If provided) loosen front bottom plate Connect cables and fasten them by use of cable clamps, connect screen wire where required 8.8 Transport restraint: Transformers are fastened with transport belts additionally. These can be removed, but have to be reassembled in case of anew lifting or transport of the substation. version: 03/2016 Subject to technical changes 13

9 Maintenance and care 9.1 Cleaning and care The materials of the substation are high-resistant and weatherproof. Powder-coated surfaces have to be handled carefully and cleaned gently. Do not use cleaner with abrasive additives. Use water and detergent. 9.2 Maintenance Maintenance of the installation with her specific kind regarding safety rules, scope and dates of inspections and maintenance work to be performed is subject to local law and local (especially environmental) conditions. Further manufacturer recommendations for routine inspections and maintenance: Always follow the applicable safety rules! - Periodic visual control, to spot potential damages on or in the substation - Check if ventilation openings are free from dust and dirt, to assure air - Clean dirty surfaces with thermal emission - Check alignment and correct closing of the doors - Check sealings for fitting and damages - Periodic check of electrical connections and earthing connections If there are no regulations, e.g. by law, operator or utility company, then we recommend a period for inspection and revision not longer than once per year, at least for visual check and cleaning. For maintenance purpose of single components please see the relevant manuals! 9.3 Adjustment of doors Safe closing of the doors is given, when the doors alignment is parallel to bottom edge of the roof. If this is not the case, little adjustment of the doors can be made. The doors have three hinges each. The middle hinge is mounted in a round hole. The top and bottom hinges are screwed in horizontal elongated holes. Cutouts in the sideways door frame allow loosening of the screw-nuts for the top and bottom hinge with an open-end wrench, to adjust the door. version: 03/2016 Subject to technical changes 14

Confirmation according to 5 par.4 of the accident prevention regulation Elektrische Anlagen und Betriebsmittel (DGUV Vorschrift 3) (electrical installations and equipment) FROM : Sächsisch Bayerische Starkstrom-Gerätebau GmbH Ohmstraße 1 08496 Neumark Germany It is confirmed that the electrical installation / the electrical equipment of production Lahmeyer type NDV 400 corresponds to the requirements of the accident prevention regulation Elektrische Anlagen und Betriebsmittel (DGUV Vorschrift 3) (electrical installations and equipment). This confirmation does not dispense the operator of the installation or equipment from testing it before startup operations or in determined periods from begin of service, e.g. regarding easing of srew connections and the like by transport (according to 5 par.4 of DGUV Vorschrift 3). version: 03/2016 Subject to technical changes 15

Risk assessment Product: Lahmeyer No. Risk 1 Direct touching 2 Indirect touching 3 High voltage Danger spot Electrical equipment of the substation Electrical equipment of the substation Electrical equipment of the substation Description of danger When touching live parts, this person s life and health are acute endangered. When touching parts, that are live by occurring failures, this person s life and health are acute endangered. When approaching live parts under high voltage, this person s life and health are acute endangered. Risk before Description of measure Risk after - Risk: high - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: high - Duration of stay in danger zone: rarely - Probability to occur: high - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - protection by housing - protection by insulation of live parts - routinely maintenance and recurrence inspection - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - testing before startup - protection by housing - protection by insulation of live parts - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - protection against indirect touching - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - testing before startup - protection by housing - protection by insulation of live parts - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - proper disconnection of the substation from supplies - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor version: 04/2015 Subject to technical changes 16

Risk assessment Product: Lahmeyer No. Risk Danger spot Description of danger Risk before Description of measure Risk after 4 5 Thermal emission or particles Emission: frequencies 6 Third persons Electrical equipment of the substation Electrical equipment of the substation Electrical equipment of the substation When approaching thermal emissions or proceedings, as projecting molten particles or chemical proceedings while short-circuits, overload etc., this person s life and health are acute endangered. When approaching emissions with low frequenzy, radio frequency etc., this person s health is acute endangered. Danger to life and health and possible destruction of the substation by unauthorized startup and use. - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Risk: middle - Extent of damage: heavy injuries - Duration of stay in danger zone: often avoid: rarely possible - Probability to occur: high - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - testing before startup - protection by housing - overload protection - short circuit protection - electric arc protection - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - proper disconnection of the substation from supplies - Installation, startup, operation and maintenance only by qualified personnel - professional design and constructing, assembly and testing - testing before startup - protection by housing - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - Installation, startup, operation and maintenance only by qualified personnel - identification - protection by housing - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - Risk: minor - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: minor - Extent of damage: heavy injuries - Duration of stay in danger zone: rarely - Probability to occur: middle - Risk: minor - Duration of stay in danger zone: rarely - Probability to occur: minor version: 04/2015 Subject to technical changes 17

Risk assessment Product: Lahmeyer No. Risk Danger spot Description of danger Risk before Description of measure Risk after 7 Strength of parts of the substation 8 Loading points 9 Lightning Surrounds of the substation Surrounds of the substation Surrounds of the substation Danger to life and health and possible destruction of the substation in case of inappropriate transport and lifting proceedings. Danger to life and health and possible destruction of the substation in case of inappropriate transport and lifting proceedings. Danger to life and health and possible destruction of the substation in case of lightning strike. - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Risk: increased - Duration of stay in danger zone: often - Probability to occur: high - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - Installation, startup, operation and maintenance only by qualified personnel - identification - professional design and constructing, assembly and testing - routinely maintenance and recurrence inspection - transport instructions, installation and maintenance manual - Installation, startup, operation and maintenance only by qualified personnel - professional installation - testing before startup - protection by housing - routinely maintenance and recurrence inspection - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor - Risk: middle - Duration of stay in danger zone: rarely - Probability to occur: minor Measures adequate: YES version: 04/2015 Subject to technical changes 18