USER MANUAL MODEL NUMBER: FST FSTK FSTV. Flooded Suction Tank. English

Similar documents
USER MANUAL MODEL NUMBER: GI-5N GI-5NK GI-5NV AND RELATED UNITS. 5 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: SP-20N SP-20NK SP-20NV AND RELATED UNITS. 20 Gallon Air Operated Portable Spray Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: GI-25N GI-25NK GI-25NV AND RELATED UNITS. 25 Gallon Air Operated Portable Gel Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

USER MANUAL MODEL NUMBER: FG-10N-2 FG-10NK-2 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

TS5600 TS5600V TS5600K

USER MANUAL MODEL NUMBER: CTX2V-EZB. EZBlend Chemical Transfer Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-5N FI-5NK FI-5NV FI-5N-ST FI-5NK-ST FI-5NV-ST AND RELATED UNITS. 5 Gallon Air Operated Portable Foam Equipment

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

FI-10 FI-10K FI-10V FI-10 ST FI-10K ST FI-10V ST

USER MANUAL MODEL NUMBER: FG-10N-3 FG-10NK-3 FG-10NV Gallon Air Operated Portable Fog Equipment. English (Original Instructions)

10 Gallon Portable Air-Operated Foaming Unit

USER MANUAL MODEL NUMBER: GK2T

USER MANUAL MODEL NUMBER: GI-30N-AM GI-30NK-AM GI-30NV-AM AND RELATED UNITS. 30 Gallon Air Operated Portable Gel Unit with Agitator

USER MANUAL MODEL NUMBER: SP-WC AND RELATED UNITS

USER MANUAL MODEL NUMBER: FI-50N FI-50NK FI-50NV AND RELATED UNITS. 50 Gallon Air Operated Portable Foam Unit. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-30N-SM FI-30NK-SM FI-30NV-SM AND RELATED UNITS. 30 Gallon Smart Foam Unit. English (Original Instructions)

Wall Mounted Foam Unit MD20016 USER MANUAL

USER MANUAL MODEL NUMBER: FOG-IT6 FG-NA-N130 FG-NA-26SS AND RELATED ITEMS. Wall-Mounted Fog System. English (Original Instructions)

USER MANUAL MODEL NUMBER: FI-WC FI-WCK FI-WCV FI-WC-AP FI-WC-ST AND RELATED UNITS

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

USER MANUAL MODEL NUMBER: SS2 SS2-FMH SS2-MBS AND RELATED UNITS

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

USER MANUAL. 2.5 and 5 Gallon Chemical Transport Jug. English

900-WC OWNER S MANUAL THIS UNIT DOES NOT INCLUDE AWATER BACKFLOW PREVENTER, CHECK LOCAL PLUMBING CODES FOR PROPER INSTALLATION. Pg.

FI-15 OWNER S MANUAL

910 BHF OWNER S MANUAL. Pg. 1 of 9

Caution! Pg. 1 of 5 I-932

CATALOG OF REPLACEMENT PARTS

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP

Owner's Manual. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/2.5 H.P. Engine, 4-Roller Pump, Deluxe Handgun) Technical Specifications

Control Panel Assembly Model : " Marathon 2000 (20 Gallon) - Series H

Set-Up Instructions. for EC-VM400. Motorized Valves

CATALOG OF REPLACEMENT PARTS C24GA6 & C24GA10 GAS CONVECTION STEAMERS PRIOR MLS COVERED IN THIS MANUAL

VALVES std $ fp $ fp $

MODEL GLC PARTS MANUAL REV.1.02A

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

MODEL EVA PARTS MANUAL Rev.1.05

MODEL EVA PARTS MANUAL Rev.1.03

VALVES. FIMCO Code # MFG Part # std $ fp $ fp $

Doorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax

PRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing

Fluid Dispensing Systems

SST Series Sand Media Filtration Systems

Tornado [Nov. 20, 2012]/Year 2000-Current: Schematics, Accessories, Brochures, Replacement & Optional Items/Carpet Care/Marathon 800, 1200 & 2000

Owner's Manual. Model: ( ) (150 Gallon, 5.5 HP Skid Sprayer) Technical Specifications. General Information. Warranty/Parts/Service

SANITIZER PARTS SANITIZER PARTS

ETP-5E & ETP-10E ECO-TECH PLUS ELECTRIC CONVECTION STEAMER PARTS AND SERVICE MANUAL

Shaft Adapter (5/8 to 3/4 ) NOTE CI = Cast Iron, N = Ni-Resist, SL = Silver Last. Series Series 7560

CATALOG OF REPLACEMENT PARTS C24EA SERIES STEAMER 3-PAN BASIC. ML /240 V. 8.5kW ML V. 8.5kW 3-PAN PRO

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A

ILLUSTRATED PARTS LIST

MODELS AH/B/C/Scullery/Pizza/Bowl PARTS MANUAL Rev 1.03B

M O D E L S EST- FL PARTS MANUAL Rev 1.00A

Parts Catalog TECHNICAL DOCUMENTS TABLE OF CONTENTS. Electric. Other. Non-electric

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.05A

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B

DEMA 258BD-200C and 258BT-200C DRAIN MASTER Jr. INSTALLATION INSTRUCTION SHEET

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.07B C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841

Gaskets. Fluid Handling Components. Bee Valve offers a full line of original and replacement gaskets to meet all your needs.

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

Gregson-Clark SPREADER-MATE

Xtrac PARTS LIST. Euroclean MODEL /05 revised 7/09 FORM NO

OPTIMUS SE-1200 SE-1250 SE-1255

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B

TECHNICAL DATA 1-1/2 (dn40)

TL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97

Calcium Chloride Pump

Shaft No. of Part # Old No. Model No. Housing Rotation dia Rollers Seals. NOTE: CI = Cast-Iron, N = Ni-Resist, SL = Silver Last

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves

:,Rhino SD/XD G/D 24 Vdc ISO

Tornado. Marathon 2000 Forward Only Extractor. Parts List Manual For Commercial Use Only CATALOG NO (115V, 60 HZ)

This catalog contains the following geothermal accessory products and specification guides:

Systems to be regarded as the # 1 Sanitizing System available on the market. Sage TM

TECHNICAL DATA. Trimpac 244a. April 15, 2011

Atomizer 36-DC User Guide

Page 1 of 19. Part# /10/2006

PARTS LIST, COUNTER CONVECTION STEAMERS MODELS SN-3E, SN-4E, SN-5E PARTS LIST COUNTER CONVECTION STEAMERS BLODGETT MODELS: SN-3E SN-4E

Parts and Accessories

LUBRICATION & FLUID HANDLING ACCESSORIES. Heavy duty knurled steel barrel with large threads for easy loading.

Cleaning Systems Inc. 2 P Rev:03

Parts Manual FRONT-FOLD BOOMS MODELS 80, 90 & 100 HYDRAULIC FOR TA1200 & TA1600 SPRAYERS. Serial Number B & Higher. Part No.

Silver Selection Sprayers Specification Sheet

SECTION 8. PARTS INFORMATION

GENERAL INSTALLATION MANUAL

Self Cleaning Suction Screen

50 GALLON LAWN & GARDEN SPRAYER

PRICE LIST

CS414HVR PLUMBING CONTROL SYSTEM INSTRUCTION MANUAL

Electronic Service Manuals

MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO & UP MODEL NO.

PARTS LIST PONY 20 SCA

Owner's Manual. (60 Gallon 3 Point Sprayer w/pump, Coupler, & 7-Nozzle Boom Assembly) Assembly. Information About The Sprayer

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Foam Output 50 gal/min (190 ltr/min) 65 gal/min (246 ltr/min) Foaming Distance 30 feet (9 meters) 35 feet (10 meters) alcohols, ketones.

DISCONTINUED. Installation S19-310SS16. Stainless Steel Combination Drench Shower and Eyewash. Table of Contents

Transcription:

USER MANUAL MODEL NUMBER: FST FSTK FSTV Flooded Suction Tank English

WARNING Read this manual completely and understand the machine before operating or servicing it. Read all instructions before installing or operating unit. Always wear appropriate personal protective equipment (PPE) when operating or servicing unit. Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Material Safety Data Sheet (MSDS). If the unit is modified or serviced with parts not listed in this manual, the unit may not operate correctly. Do not exceed an incoming air pressure of 100 psi (7 bar). Do not exceed a fluid temperature of 100 F (37 C). Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install an air dryer before unit. Do not use an air lubricator before the unit. Always flush the unit with fresh water for at least 5 minutes when switching from an alkaline to an acid or an acid to an alkaine. Never operate unit without the lid (FST-LID) on. Never open ball valves (PBV12M12F) when there is chemical in the tank, unless the ball valves are connected to an appropriate location for chemical discharge. Chemical will flow out of the tank through the open ball valve(s). Do not use the unit if an overflow hose is not installed. If chemical flows from the overflow port, shut down the unit immediately and correct the problem before proceeding. Do not use the unit if it is damaged or leaking. Specifications: Tank Capacity: 2.6 gallons (10 liters) Ball Valve Threads: 1/2 inch NPT female Requirements: Compressed Air Pressure Requirements: Air regulator (R25) factory set at 50 psi (3.4 bar). Operating range is 40 to 80 psi (3 to 5 bar) with 2 CFM (56.6 l/min) Electrical Requirements: 100-240 VAC at 60 Hz, 2 amps (GFCI Protected Circuit) Chemical Requirements: Follow all instructions from chemical manufacturer and Material Safety Data Sheet (MSDS). Air Operated Double Diaphragm Pump Models Offered: P56: Polypropylene body with Santoprene diaphragm P56V: Polypropylene body with Viton diaphragm P56K: Polypropylene body with Kalrez diaphragm Acceptable Products: Alkaline cleaners, Acid cleaners and Sanitizers. Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or MSDS for your product or contact our customer service department. PROTECT THE ENVIRONMENT Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations. Always remember to recycle. *Specifications and parts are subject to change without notice. Page 2 of 7 05062014

Installation Instructions: 1. Remove all components from packaging. 2. Select desired area to mount the unit. Note: Unit must be mounted in an area with a sanitary sewer drain. 3. Make sure the mounting bracket (WMBRKT2X8) is oriented correctly, and secure it to the wall using two of the screws and plastic anchors provided. Note: To drill holes for the plastic anchors, use a 1/4 inch drill bit. The two holes should be 8 inches (20.32 cm) apart. 4. Mount the unit by connecting the bracket (TBRKT) located on the back of the tank to the bracket (WMBRKT2X8) on the wall. 5. Open the lid (FST-LID) by removing all 4 screws (AS1-VS) and set aside. 6. Connect one or more of the ball valves (PBV12M12F) on the underside of the unit to your existing metering pump(s). Note: The ball valves (PBV12M12F) have 1/2 inch NPT female threads. 7. Connect your chemical source to the input barb (HB5638/ HB5638K/HB5638V) located on the underside of the pump (P56/P56K/P56V). Note: Strainer must be used on intake line. 8. Connect a hose to the overflow port, located on the upper left side of the unit, and run the hose back to your chemical source or to another location that is situable for chemical discharge. Note: The overflow port has 1/4 inch NPT female threads. 9. Close the four ball valves (PBV12M12F) located on the underside of the unit. 10. Connect a compressed air supply line to the air inlet fitting (AP25). Note: Check for proper air pressure on air gauge (AG100). Air regulator (R25) factory set at 50 psi (3.4 bar). Operating range is 40 to 80 psi (3 to 5 bar) with 2 CFM (56.6 l/min). 11. Check to ensure ball valve (PVCV14FM) is in the open position. 12. Close and secure the lid (FST-LID) of the tank unit with all 4 screws (AS1-VS). Operation instructions: 1. Follow all instructions from the chemical manufacturer. 2. Verify that all of the ball valves (PBV12M12F) that will not be used are closed and/or plugged. 3. Verify that the pump (P56/P56K/P56V)) is connected to the chemical source. 4. Plug in the 24 VDC power adapter (PS120-24V) to a 100-240 VAC power source to active the unit. When the unit is active, the pump (P56/P56K/P56V) will start to cycle. The pump (P56/P56K/P56V) will stop cycling when product reaches the appropriate fill level, and it will remain inactive until fluid level decreases. 5. Open the ball valve(s) (PBV12M12F) that are connected to your metering pump(s). Any ball valves that are not connected to a metering pump should remain closed. Page 3 of 7 05062014

After Use Instructions: We recommend flushing the unit with fresh water for 5 minutes or until all chemical has been discharge from system before shutting down unit. To shut down unit, unplug the 24 VDC power adapter (PS120-2V). Maintenance Instructions: To keep your unit operating properly, periodically perform the following maintenance procedures: Note: Before performing any maintenance, drain the tank and ensure that the unit has been disconnected from compressed air and electrical power. Inspect the pump (P56/P56K/P56V) for wear and leaks. Inspect all hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured. Replace the filter located within the air regulator (R25) as needed. Clean by unthreading the air regulator bowl (ABR25) from the air regulator (R25). Check the suction line and strainer for debris and clean as needed. Drain your air compressor tank on a regular basis to help extend pump life. An air source with a high moisture content will accelerate pump wear. Note: If your air source has a high moisture content, you may wish to install a water separator (WS-20CFM) before the unit. Troubleshooting Instructions: Check the air regulator bowl and air filter for debris such as water, oil, or rust particles. Clean by unthreading the air regulator bowl from the air regulator (R25). If air passes through the pump (P56/P56K/P56V) without cycling, the pump needs to be replaced. If chemical flows from the overflow port, the solenoid valve (SCV110) or air operated valve (AOV38) may need to be replaced. Check for proper air pressure on air gauge (AG100). Air regulator (R25) factory set at 50 psi (3.4 bar). Operating range is 40 to 80 psi (3 to 5 bar) with 2 CFM (56.6 l/min). Check to ensure ball valve (PVCV14FM) is in the open position. If the unit operates at a reduced pressure: oo oo Check the air compressor supplying the unit. If the pressure is less than 40 psi, turn the unit off until the compressor can catch up. If the air supply is 50 psi (4.14 bar) or above, check the air gauge (AG100), which should read near 50 psi (4.14 bar). If the air gauge reads more or less than 50 psi (4.14 bar), adjust the pressure by turning the knob on the top of the air regulator (R25). Page 4 of 7 05062014

TANK ASSEMBLY TANK-FST JC35B Overflow Port FST-LID (Safety Shield) AS1-VS PBV12M12F PS120-24V TBRKT WMBRKT2X8 WMS14 Page 5 of 7 05062014

CONTROL BOX ASSEMBLY PB633 CGRP12 CTRLBSN PB633-SCREW PL633 QFSA1414 SCV24 P56, P56K or P56V FLSEN-PT P56-BRKT B63212 R25 QF14PAF HB5638, HB5638K or HB5638V SSC38 PVCV14FM HBEL1438 HHPB1214 AP25 AG100 SN1414 HBEL3838 AOV38-EPDM, AOV38-SIL or AOV38-V QFT14 QFSA1414 QF14P HBEL3838 Page 6 of 7 05062014

ITEM NUMBER AG100 AOV38-EPDM AOV38-ORK- EPDM AOV38-SIL AOV38-ORK-SIL AOV38-V AP25 AOV38-ORK-V ITEM DESCRIPTION 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE AIR OPERATED VALVE WITH 3/8 IN FPT-EPDM O RINGS O RING KIT FOR AOV38-EPDM AIR OPERATED VALVE WITH 3/8 IN FPT-SILICONE O RINGS O RING KIT FOR AOV38-SIL AIR OPERATED VALVE WITH 3/8 IN FP-VITON O RINGS O RING KIT FOR AOV38-V PLUG 1/4 NPTM AIR FITTING - BRASS AS1-VS 1/4-20 X 1/2 PHIL TRUSS MACH SCREW 19-8 W/516 ORANGE VIBRASEAL PATCH B63212 CGRP12 CTRLBSN FLSEN-PT FST-LID HB1238 Screw, 6-32 Thread, 1/2in Length CORD GRIP 1/2 INCH CONTROL BOARD FOR SENSOR ON FST UNITS CTRLBSN FLUID LEVEL DETECTION SENSOR FOR PLASTIC TANK-3 WIRE MODEL LID FOR TANK-FST 1/2in MPT X 3/8in HOSE BARB HBEL1438 HOSE BARB ELBOW 1/4 X 3/8 HBEL3838 HOSE BARB ELBOW 3/8 X 3/8 HHPB1214 JC35B JC35B-P JC35-CV JC-G35 HEX HEAD POLY REDUCER BUSHING 1/2in X 1/4in HEX HEAD POLY REDUCER BUSING 3/8in X 1/4in BLACK 3.5 INCH ONE WAY VENTED CAP POLYPROPYLENE WITH GASKET AND CHECK VALVE BLACK 3.5 INCH CAP - POLYPROPYLENE EPDM CHECK VALVE FOR NON LOCKING JUG CAP JUG CAP GASKET 3.5 INCH CAP EPDM JC35SSCS VENTED 18-8 SS SOCKET HEAD CAP SCREW, 10-32 THREAD, 3/4 INCH LENGTH.046 VENT DIAMETER P12 P18 P56 P56K P56V 20756103B HB14P HB5638 HB5638K HB5638V P56-BRKT PB633 HEX HEAD PLUG WITH 1/2 M.P.T. POLY PLUG 1/8 MPT HEX HEAD 5700 PUMP WITH SANTOPRENE SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT 5700 PUMP WITH KALREZ SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT 5700 PUMP WITH VITON SEALS - INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT Polypro G57 Air Port x HB Straight, w/ Viton o-ring 1/4in BRASS HB AIR FITTING /G57/P56 HOSE BARB FOR P56 PUMP HOSE BARB FOR P56K PUMP HOSE BARB FOR P56V PUMP PUMP BRACKET- STAINLESS STEEL CONTROL BOX BODY - POLYPROPYLENE - 6x3x3 PB633-GSKT PB633-SCREW PBV12M12F PL633 PS120-24V PVCV14FM QF14P QF14PAF GASKET FOR POLY CONTROL BOX 6x3x3 SCREW FOR PB633 CONTROL BOX - POLYPROPYLENE POLYPROPLENE BALL VALVE-1/2 MPT TO 1/2 FPT CONTROL BOX LID - POLYPROPYLENE - 6x3x3 PLUG-IN VOLTAGE TRANSFORMER, 120 VAC INPUT, 24VDC OUPUT VA PVC 226-4F4M-B, RD. FLUT MALE CON. 1/4in TUBE X 1/4in MPT POLYPROPYLENE 1/4in QF PUMP AIR FITTING / G57 12 pack QFSA1414 STEM ADAPTER 1/4in STEM X 1/4in NPT - POLYPROPYLENE QFT14 R25 AFR25 ABR25 SCV24 SN1414 UNION TEE 1/4in TUBE - POLYPROPYLENE AIR REGULATOR - 1/4fpt TWO PORT 1/8fpt TWO PORT - INCLUDES FILTER AND BOWL AIR FILTER for R25 METAL AIR BOWL for R25 SOLENOID COIL VALVE 24 VDC STAINLESS 1/4MPT X 1/4MPT NIPPLE SSC38 WORM GEAR CLAMP, S/S (.25-.63) TANK-FST TBRKT WCH3P WCTF WMBRKT2X8 WMS14 WMS14A TANK FOR FST FST TANK BRACKET CONN HOUSING 3POS.156 W/RAMP CONN TERM FEMALE 22-26AWG TIN WALL MOUNTING BRACKET 2X8 - FST 14 X 1 1/4 HEX W/H SMS SLOTT, S/S 5/16 X 1 1/2 STRAIGHT PLASTIC ANCHOR Page 7 of 7 05062014