B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Similar documents
N-02 MAINTENANCE MECHANIC TRAINING SKILL DEVELOPMENT GUIDE

ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE

Why is the Breaker Tripping?

CALTRAP INSTALLATION AND OPERATIONS MANUAL

MAGNETIC MOTOR STARTERS

Electric Motor Controls BOMA Pre-Quiz

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

COLDWATER LAKE FACILITIES DUPLEX PUMP STATION

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Single-Phase Underground Operating

DC Series Motors by Thomas E. Kissell Industrial Electronics, Second Edition, Prentice Hall PTR

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Overcurrent protection

LED TROUBLESHOOTING. Controller Version L610 Rev 7M or newer (manufactured after 1/21/15)

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

2015 WDC Disturbance and Protection Standards Overview

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Building Operator Certification Level I

TIME REQUIREMENT GUIDE (TRG)

Electrical Safety For Everyone. Leader s Guide

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

GENERAL <ELECTRICAL>

Electrical Safety. Introduction

ECET Distribution System Protection. Overcurrent Protection

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Overhead Switching Devices

Series 1000 and Figure NOTE: The top terminals are showing normally closed at rest and the middle terminals are normally

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 16 September 2017 QUESTION AND ANSWER BOOKLET

GENERAL <ELECTRICAL>

ELECTRICAL HAZARD EXAMPLES

BP-Husky Refinery Toledo, OH

Understanding Electricity and Electrical Safety Teacher s Guide

Circuit Concepts (Residential)

ELECTRICAL. 60 Minutes

Transformer Protection

Ex. 1-1 Nacelle Familiarization and Safety Discussion

Installation Instructions For Motor Control Center (MCC) Units

Instruction Manual. Q Series 2 Motor Control Modules - OEM

FACT SHEET Standard: Electrical Safety

AVOIDING ELECTROCUTION HAZARDS

WARRANTY WILL BE VOID If These Steps are Not Performed Before Installing The Control STEPS TO PERFORM BEFORE CONTROL INSTALLATION

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

ELECTRICAL AREA CONTROLLED ACCESS PROCEDURE SP-18 NATIONAL HIGH MAGNETIC FIELD LABORATORY NHMFL FLORIDA STATE UNIVERSITY SAFETY PROCEDURE SP-18

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Service Entrance Methods

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Installation Instructions

Grounding Of Standby & Emergency Power Systems

SECTION 3.00 WARNING WARNING ENGINE STARTUP AND SHUTDOWN PRESTART INSPECTION

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

BATTERY CHARGER AR-D

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

3 Phase Smart Controller

Boardworks Ltd Mains Electricity

1993 Lionel Trains, Inc., Chesterfield, MI LIONEL RS-I TRANSFORMER

7. SERVICES OVER 600 VOLTS

Learning Module 10: Loadcenters. 101 Basic Series

Electrical Safety. Facilitator Guide

BASIC TROUBLESHOOTING START / STOP PUSHBUTTONS, PILOT LIGHTS, RELAYS, TIMER LIMIT SWITCHES, FLOW SWITCHES, THERMAL SWITCHES, AND OVERLOAD RELAYS.

AC motor control circuits

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

The Evolution of Arc Fault Circuit Interruption

OutdoorXUPS-600AHV-8364

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

INSTALL CIRCUIT PROTECTIVE DEVICES

Installation Instructions Electric Heaters 5 20 kw

GPA 13.8 kv Semi-Annual Slip Ring PM, Sav 10-41

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

TROUBLESHOOTING FOR IDEAL - SCHWAB PATERNOSTER Models: TPL - 2 HD & TPL - S

Service Procedure # CDV-101

Selective Coordination Requirements

Electrical Equipment and Terminology

Troubleshoot Furnace (Troms)

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Safety Training Topic ELECTRICAL SAFETY

Installation Instructions Electric Heaters 5 20 kw

ST Charger. Industrial Battery Charger

Basic Electrical Safety

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

AutoLink Frequently Asked Questions

Fault Finding. Standard/Fundamental Faults

Electrical Safety. Recognizing & Controlling Hazards

PROCESS ELECTRONICS CORPORATION

Adapted from presentation developed by Scott Fausneaucht

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

4-Day Power System Analysis, Coordination, System Studies

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

What is included in a circuit diagram?

Symptom Corrective Action. Wrong polarity of cell, block, row of battery. Interruption at connector. Interruption due to empty cell.

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Transcription:

B-03 ELECTRICIAN TRAINING SKILL DEVELOPMENT GUIDE Duty B: Power Distribution (600V and below) B-03: Troubleshoot 480V System Issued 06/01/98

Task Preview Troubleshoot 480V System The 480V distribution system powers the plant from the substation. When some part of the system fails, anything from one machine or light to the whole plant goes down. The Electrician must be able to diagnose the problem and isolate the component failure efficiently to quickly restore power. The Electrician must also be able to diagnose the conditions that caused the problem and recommend corrections to prevent recurrence. How your skills will be checked The Skill Check will require you to troubleshoot a problem in a 480V power distribution system. All tools, materials, and resources will be available. The Evaluator will verify that your demonstration meets the skill objective by observing or measuring each task standard. You must demonstrate safe work practices during the Skill Check. Contact your Evaluator when you are ready for the Skill Check. Skill Development Guide 2 B-03: Troubleshoot 480V System

Skill Objective Given a problem in a 480V power distribution system, troubleshoot the system to identify the component at fault and the conditions that caused the problem. Task Standards 1. Power is restored to all circuits quickly. 2. All safety requirements are demonstrated. Skill Development Guide 3 B-03: Troubleshoot 480V System

What You Will Need This section contains the safety information, tools, and resources you will need before you can troubleshoot a 480V system. Follow all Caterpillar facility safety standards when performing this task. Lock out and tag the power disconnect supplying a section of distribution equipment before testing the section for ground and line faults. Appropriate Electrician s gloves are required when working on live circuits of 50V or more. A ladder or manlift and harness is necessary to work on overhead distribution equipment. Electrician s pouch, with wiggy and DVM prints of power distribution equipment persons who may have been present and/or involved when the system problem occurred Skill Development Guide 4 B-03: Troubleshoot 480V System

Task Steps Troubleshoot 480V System 1. Investigate the symptoms. Determine the specific loads, drops, and areas where a power outage, lost phase, or other 480V power distribution problem has been reported. Measure voltage between each phase and ground, and between each phase pair at the affected load, or at one of the loads in the affected area. Determine when the problem occurred, if possible, and what equipment the 480V distribution system was powering at the time. 2. Identify the cause of the symptoms. In most cases, the cause will be a tripped circuit breaker or a blown fuse. Lockout and tagout the disconnect. If there is no voltage to ground on any phase and no voltage between any phase pair, a circuit breaker is tripped. a. If only one load is affected, the circuit breaker/disconnect supplying that load is tripped. b. If all the loads supplied through a load control center are dead, the load control center main breaker is tripped. c. If a whole area is affected, the substation circuit breaker is tripped. If voltage between two phases is normal, but voltage between either of those phases and the third phase is zero or low, a fuse is blown. a. If only the load or loads supplied by one drop are affected, one of the bus plug fuses that supply the drop is blown. b. If all the drops supplied by one or more bus ducts are affected, one of the fuses in the distribution bus duct(s) that supplies the bus duct(s) is blown. If necessary, obtain prints of the affected parts of the distribution system. Use the prints to map out the affected drops, bus ducts, or area. Skill Development Guide 5 B-03: Troubleshoot 480V System

If prints are not available, visually trace the feeders. Many bus ducts are labeled; signs on them identify the distribution bus duct(s) and substation supplying them. 3. Test the cause of the symptoms. Find and inspect the circuit breaker or fuse identified in step 2. Caution: Do not reset any tripped breaker or replace any blown fuse until the problem that caused it to open has been corrected. Do not try to defeat interlocks on fused disconnects. If you suspect a fuse is blown, set the disconnect to OFF before opening the cabinet. In general, test a fuse by measuring the resistance through it rather than the voltage across it. 4. Determine why the breaker tripped or the fuse blew. Blown fuses and tripped circuit breakers are occasionally the result of a problem with the circuit breaker, fuse, or associated equipment. More often, breakers trip and fuses blow because of a ground fault, a line fault, or an overcurrent condition. 5. Identify the causes of a blown fuse or tripped breaker. Inspect the equipment. Look for: a. loose, corroded, or overheated-appearing terminals and conductors; b. overheated, cracked, or missing insulation; c. charred or burned insulators or cases on molded case circuit breakers; d. loose, corroded, or overheated-appearing fuse clips; e. loose, corroded, or overheated-appearing bus stabs on circuit breakers (large breakers will have to be racked out for this inspection). Note: Circuit breakers that have interrupted fault current too many times may overheat and trip on less than their rated current. Skill Development Guide 6 B-03: Troubleshoot 480V System

If all equipment appears to be in serviceable condition, check for a ground fault - a low-resistance path that allows high current between one phase and ground. a. Shut off, lock out and tag power (if necessary). b. Measure the resistance between each phase and ground on the load side of the blown fuse or tripped circuit breaker. A reading of less than 1 megohm between any phase and ground indicates a ground fault. c. Open (one at a time) every disconnect on the load side of the blown fuse or tripped circuit breaker while monitoring phase-to-ground resistance. When the low resistance disappears after opening a disconnect, the ground fault is in a component (conductor, bus, disconnect equipment, or load) on the load side of that disconnect. d. Close all other disconnects, reset the tripped circuit breaker or replace the blown fuse and restore power to the rest of the distribution system. e. Find the ground fault in the isolated part of the system by a similar procedure: disconnect sections or components until the low resistance to ground disappears. f. Correct the ground fault before restoring power to the disconnected circuits. If all phases read high to ground, check for a line fault - a low-resistance path that allows high current between two phases. a. Open load control contactors or switches to disconnect all loads on the load side of the blown fuse or tripped circuit breaker. b. Disconnect all transformer windings that are normally connected between phases on the load side of the blown fuse or tripped circuit breaker. c. Measure the resistance between each pair of phases. A reading of less than 1 megohm between any phase pair indicates a line fault. Skill Development Guide 7 B-03: Troubleshoot 480V System

d. Open (one at a time) very disconnect on the load side of the blown fuse or tripped circuit breaker while monitoring phase-to-phase resistance. When the low resistance disappears after opening a disconnect, the line fault is in a component (conductor, bus, or disconnect equipment) on the load side of that disconnect. e. Close all other disconnects, reset the tripped circuit breaker, or replace the blown fuse and restore power to the rest of the distribution system. f. Find the line fault in the isolated part of the system by a similar procedure: disconnect sections or components until the low resistance disappears. g. Correct the line fault before restoring power to the disconnected circuits. Note: Any line-to-ground or line-to-line reading lower than 1 megohm indicates an insulation problem. Recheck the resistance with a megohmmeter. The high voltage a megohmmeter applies can reveal arc paths that could carry fault current. If there are no ground or line faults, check for an overcurrent condition a load problem that results in load current higher than the fuse or circuit breaker rating. a. If the open circuit breaker or fuse supplies one load, the overcurrent was caused by problems such as an overloaded motor or a line-to-ground or line-to-line short in the windings of a motor or transformer. Note: Individual motors are protected by overload breakers that trip when motor current is too high for too long. The circuit breakers and fuses supplying motors are sized to carry full load current and starting current. Thus, if a circuit breaker or fuse supplying a single motor opens on startup, a ground fault or line fault in the motor or in the conductors to it, rather than an overloaded motor, is probably the cause. Skill Development Guide 8 B-03: Troubleshoot 480V System

Note: Power distribution systems are designed to handle all expected loads. However, sometimes the designer underestimates, or additional loads are added to an existing system beyond the capacity of the original circuit breakers or fuses. Note: Because loads are not part of the 480V distribution system, troubleshooting overcurrent conditions in individual loads is not part of this task. However, an overcurrent condition caused by too many loads on full at once is a distribution system problem. An Electrician must be able to recognize such a situation. Many substation circuit breakers, and some modern circuit breakers intended for high-current individual loads, have indicators on them that flag the causes of the trip. If the long time overload indicator is set when such a breaker trips, the Electrician would know to look for conditions where too many loads were on simultaneously. b. With all system disconnects open on the load side of the blown fuse or tripped circuit breaker, reset the breaker, or replace the fuse and restore power. c. Close each disconnect individually, while monitoring current at the circuit breaker or fuse that opened. Current should remain zero, except when a closed disconnect energized a transformer primary winding; the magnetization current in such windings should be very small. d. Turn loads on one at a time. Verify that the current each load draws is normal. If total current approaches the rating of the fuse or circuit breaker, notify the appropriate personnel that the distribution system needs to be upgraded or reconfigured. e. If total current is within the rating of the fuse or circuit breaker, prepare to monitor the current at the fuse or circuit breaker for an extended period to identify an intermittent ground fault, line fault, or overcurrent condition. Also monitor the fuse or circuit breaker for overheating. Skill Development Guide 9 B-03: Troubleshoot 480V System

Concept Check Troubleshoot 480V System Answer the following questions to check your understanding of how to troubleshoot a 480V system. Circle the correct answer in each question. Then compare your responses with the answers at the end of the Skill Check. Some of the questions may have more than one correct answer. If you have difficulty answering a question, review the Skill Development Guide or ask your Trainer for assistance. 1. The first step in troubleshooting a 480V system is to: a. measure the incoming voltage and current. b. check the phase imbalance. c. identify the loads, drops, or areas where power is out. d. inspect all fuses and circuit breakers in the affected area. 2. If voltage is zero or low to one phase of a three phase system: a. a fuse is probably blown. b. a circuit breaker has tripped. c. the connection to ground on that phase is open. d. that phase is overloaded. 3. When you find a blown fuse or tripped circuit breaker, the next step is to: a. replace the blown fuse or reset the tripped breaker. b. test the blown fuse or tripped breaker. c. disconnect power to the blown fuse or tripped breaker. d. determine why the fuse blew or the breaker tripped. Skill Development Guide 10 B-03: Troubleshoot 480V System

4. A ground fault is: a. A high resistance between all phases and ground. b. An open circuit to ground. c. A low resistance to ground on one phase. d. The current that flows after a fuse blows or a breaker trips. 5. To isolate a line fault: a. Open circuits until the low line-to-line resistance disappears. b. Close circuits until a fuse blows or a circuit breaker trips. c. Check for abnormally high current into each circuit. d. Use a megohmmeter to look for high resistance. 6. To identify the cause of a long time overcurrent condition: a. Disable the overload devices protecting individual loads. b. Measure current to each load powered through a fuse or breaker. c. Measure the total current on the supply side of a fuse or breaker. d. Use a current probe to measure the current at each load. Answers: (1. c 2. a 3. c 4. c 5. a 6. b, d) Next Step If you are ready to demonstrate the task now, ask your Evaluator or Trainer to schedule the Skill Check. However, if you need to practice some of the steps first, continue to the next section. Skill Development Guide 11 B-03: Troubleshoot 480V System

Practice The following practice will help prepare you for the Skill Check. Ask your Trainer to set up the practice for you. After you complete a practice, ask your Trainer to check your work. Practice 1: List the appropriate steps to respond to a problem specified by your Trainer in a 480V distribution system. Practice Objective 1: Your proposed steps must: be safe to perform not damage any equipment positively identify the responsible component with the fewest possible steps Skill Development Guide 12 B-03: Troubleshoot 480V System

Practice 2: Determine if a problem simulated by your trainer in a 480V distribution system is due to a blown fuse or a tripped circuit breaker. Practice Objective 2: You must be able to state whether a fuse has blown or a circuit breaker has tripped. You must also be able to explain your reasoning. Practice 3: Use system prints to identify a blown fuse or tripped circuit breaker responsible for a problem simulated by your Trainer in a 480V distribution system. Find the identified fuse or breaker and demonstrate that it is open. Practice Objective 3: You must identify and find the correct fuse or breaker. Practice 4: Test a section of a 480V distribution system for an overcurrent condition. Practice Objective 4: You must be able to state whether the current in the section is too high for the overcurrent devices (fuses or circuit breakers) protecting the section. Next Step Continue to practice until you are ready for the Skill Check. When you are ready to demonstrate the task, ask your Evaluator or Trainer to schedule the Skill Check. Skill Development Guide 13 B-03: Troubleshoot 480V System