STANDARD / DOUBLE STANDARD MAGNETIC LOCK

Similar documents
Electromagnetic Locks Indoor GEM Series

MAGLOC660 ELECTROMAGNETIC LOCK

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

Installation Instructions for Slide Mount Magnetic Locks

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

ELECTROMAGNETIC LOCKS

Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

V2M1200/1290 Series Maglock Installation Instructions

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Pre-Installation Instructions

Pre-Installation Instructions

MODEL 1200S MAGNETIC LOCK

Standard Auxiliary L-Brackets & LZ-Brackets

M400 Series Double Locks. Features

INSTALLATION 8310/8320

Accessories 286 SDC SECURITY DOOR CONTROLS

Security Door Controls

SAFETY

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

Instructions For PG-1200RC Magnetic Locking Devices

ELECTROMAGNETIC LOCKS

R F O U PRICE LIST 2016

MODEL 1200S MAGNETIC LOCK

A5000GEC-24VDC ZERO SPEED SWITCH

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

REMOTE CENTRAL LOCK. Model: CLRxxx-ULT

Electric Dropbolts. Secure and Intelligent Bolts. Fail-Safe Series Functions. DPS & BSS Outputs. Fail-Secure Series Functions

Electromagnetic Locks Weatherproof Series

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

2965 Magnetic Shear Lock Installation Instructions

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Speedometer Interface

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

Electromagnetic Locks

V-Twin Forward Control Installation Instructions

INSTALLATION & OWNER'S MANUAL

30100 Module Installation Guide L

Muto Electro Magnetic Lock (Elock MEM4400) Installation instructions / Wiring manual

M670/M680BD MAGNALOCK SERIES Installation Instructions

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Grove EKS4 Microtec MkII Light Control Module Input Connection

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

J1939 POWERCELL Setup and Configuration Guide Universal Switch Interface

15100 Module Installation Guide Mercedes EPA07 w/dpf

HANDLING MECHANICAL INSTALLATION

Trilogy Double-Sided DL5200, DL5300 & PDL5300 Installation Instructions

Grove EKS 5 Microtec MkII Light Control Module Input Connection

Aura CM-54i Surface Mount Illuminated Enclosure Installation Instructions

20250 Module Installation Guide

Motorized Stainless 2-Way Valves

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia

Aura CM-55i Flush Mount Illuminated Enclosure Installation Instructions

1014-CTC WARRANTY AND DISCLAIMER

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

Auto-Trol Limited 1660 SW 196th Avenue * Aloha, OR 97003

Installation Instructions

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Package Contents. Mounting Hardware

Female Plug. connecting to Fuel Quantity

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

CDL - 04R / CDL - 04 USER S / INSTALLERʼS MANUAL

Digital Trim. Part # 1037 WARRANTY AND DISCLAIMER

Two Channel Remote Shutdown Device

Installation / Operation Instructions Sunnex ORION Series Exam Lights

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

Eternity-TK-Controller (EDC700 Series)

Duplex Booster System Instruction Manual

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

SL-150 Magnetic Lock for Sliding Door Installation Manual

RACE PPE Manifolds and Up-Pipes

Grid Tied Limiter User Manual

Using the power override wire. LED Interior Light System (Optional) Adjusting the shelves: TIPS:

Electromechanical Locking Solutions. Side Load Locks, Drop Bolts, Electric Strikes, Electromagnetic Locks, Roller Door and Gate Locks, Cable Transfers

Guardian HH Shaft Coupling

Generator Start Control Module

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

Long-Range Barrier Sensors

Installation Instructions

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

Crossover WARRANTY AND DISCLAIMER

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

Installation Instructions

INSTALLATION, MAINTENANCE & SERVICE MANUAL

Fitting Instruction for EZI-GRIP Bike Rack

90 Series - Socket overview for 60 series relays

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

Transcription:

STANDARD / DOUBLE STANDARD MAGNETIC LOCK INSTALLATION MANUAL

INDOOR ELECTROMAGNETIC LOCK SERIES Spec/Model GEM-300 Single GEM-600 GEM-800 GEM-1200 Double GEM-D600 GEM-D800 GEM-D1200 Holding Force 300lbs (136kg) 600lbs (272kg) 800lbs (363kg) 1200lbs (545kg) 600lbs (272kg)x2 800lbs (363kg)x2 1200lbs (545kg)x2 Voltage Input Current Draw x2 x2 x2 x2 x2 x2 Basic Installation Concept & Accessories Cable Wire 12/24 VDC Mounting Plate Self-tapping Screw x5 Cover Screw Cable Wire 12/24 VDC Self-tapping Screw x10 Fixing Screw x2 Cover Plate Armature Screw Anti-tamper Nut x4 Mounting Plate Fixing Screw x4 Electromagnet x2 Allen Wrench Electromagnet Armature Plate Rubber Washer Guide Pin x2 Sexnut Bolt Metal Washer x2 Anti Residual Magnetism Part Armature Plate x2 Cover Plate Armature Screw x2 Cover Screw x2 Anti Residual Magnetism Part x2 Rubber Washer x2 Sexnut Bolt x2 Allen Wrench Metal Washer x4 Guide Pin x4 UBK Bracket For Glass & Glass EM Bracket For Inswing With Cover LZ Bracket For Inswing Glass Glass Inswing Inswing Inswing Standard Installation For U Bracket For Glass L Bracket For Glass

LZ bracket for Inswing doors 1 2 3 4 Find a mounting location on the door frame for the L bracket. Make sure that the door is still closeable. Use the fixing bolt to tighten the electromagnetic lock on L bracket Assemble the Z bracket, and make sure that the position of the Z bracket is adjustable. Insert the guide pins into the armature plate. 5 6 7 Finish Fasten the armature plate to the Z bracket (Must add rubber washer) Standard Installation Close the door and connect the power. After the maglock attracts the armature plate, adjust the Z bracket to fit the door. Fasten the Z bracket to the door 1 Template Fold the mounting template 90 5 Rubber Washer The rubber washer makes the surface of the armature plate adjustable in order to completely fit the surface of magnetic lock. 2 Place the template to the proper position of the door and frame. Mark the hole positions of the template on the door and frame. 6 Fasten the mounting plate with the mounting screws. The position of the mounting plate should be adjustable. 3 Drill the holes according to the marks. 7 Fix the mounting plate on the door with mounting screws 4 Armature Plate Please install the armature plate as illustrated here. (Dimensions of the holes depend on the door types illustrated below.) 8 Allen wrench Use the Allen wrench and fixing bolts to tighten the electromagnetic lock to mounting plate Hollow Metal Reinforced Solid 9 36mm Connect the power and test the unit. 12.7mm 8mm Drill a Ø8mm hole through door, on closing side.enlarge to Ø12.7mm by a sexnut blot on the opening side. Recommendation: 6.8mm for M8-1.25 thread 12.7mm 8mm Drill a Ø6.8mm hole Drill a Ø8mm hole through and tap on closing side door on closing side.enlarge a M8x12.5 thread. to Ø12.7mm by a sexnut blot on the opening side. The depth is 36mm. For Micro EM-locks (300 LBS), maximum thickness of door is 44 mm. For Mini EM-locks (600 LBS), maximum thickness of door is 50 mm. For Midi EM-locks (800 LBS), maximum thickness of door is 48 mm. For Maxi EM-locks (1200 LBS), maximum thickness of door is 46 mm.

SPDT relay 0.5A/125VAC 1A/24VDC Connecting Diagram Model:GEM-300M N.C.COM. N.O. LED indicator GREEN: Open RED : Locked NO LED: No power SPDT relay 0.5A/125VAC 1A/24VDC Input Input Sensor Input GEM-300, GEM-600, GEM-800, GEM-1200 GEM-D600, GEM-D800, GEM-D1200 N.C. COM. N.O. Mag Input Sensor Input GEM-800MDS-TD-LD, GEM-800MTD-LD GEM-1200MDS-TD-LD, GEM-1200MTD-LD Relock time delay (Optional) Ensures the automatic lock mode works after the door is closed properly and it can be adjusted from 1 to 80 seconds. TD series N.C. C OM N.O. RST RST Lock Sensor Input Timer Adjustment 1~80 seconds JP Setting Green LED (Default) Input LED indicator GREEN: Open RED: Locked NO LED: No power Orange: N.O. White: Com Brown: N.C. (PCB back) Green LED Red LED Status Sensor (optional) Status Sensor indicates the door is in an open or closed status. DS series Red LED Sensor in

Connecting Diagram Orange: N.O. White: Com Brown: N.C. Status Sensor (optional) Status Sensor indicates the door is in an open or closed status. GEM-600MDS, GEM-800MDS, GEM-1200MDS GEM-D600MDS, GEM-D800MDS, GEM-D1200MDS GEM-600M, GEM-800M, GEM-1200M GEM-D600M, GEM-D800M, GEM-D1200M LED indicator GREEN: Open RED : Locked NO LED: No power N.C. COM. N.O. Timer Adjustment Mag Input 1~80 seconds Sensor Input Relock time delay (Optional) Ensures the automatic lock mode works after the door is closed properly and it can be adjusted from 1 to 80 seconds. GEM-600M, GEM-800M, GEM-1200M GEM-D600M, GEM-D800M, GEM-D1200M Buzzer Alarm (on the reverse) Held Open Alarm is an auditory feedback for users. Alarm sounds when the door is not closed for over a specified time limit. VR timer (Timer Adjustment) is adjustable from 1 to 80 seconds. (Available for GEM-800MBZ & GEM-1200MBZ) GEM-D800MBZ & GEM-D1200MBZ) Trouble Shooting Problem Possible Cause Solution does not lock Low holding force Sensor output is not functioning No power Poor contact between electromagnet and armature plate Low voltage or incorrect voltage setting A secondary diode was installed across the electromagnetic lock Misalignment between the armature plate and electromagnetic lock Make sure the wires are connected properly Check that the power supply is connected and works properly Make sure the lock switch is wired correctly (N.C.) Make sure if the armature plate is deformed Make sure if the rubber washer was used between magnet lock and armature plate Make sure the contact surfaces of the electromagnet and armature plate are clean and free from dust Ensure the electromagnet lock is set for the correct voltage. Check for proper voltage at the electromagnetic locks input. If low, determine if the correct wire gauge is being used to prevent excessive voltage drop. Remove any diode installed across the magnet for "spike" suppression. (The magnet is fitted with a metal oxide varistor to prevent back EMF) Make sure the armature plate and electromagnetic lock are aligned correctly

H WARRANTY: The warranty period of Transmitter Solutions magnetic locks is twenty-four (24) months. This warranty shall begin on the date the keypad is manufactured. During the warranty period, the product will be repaired or replaced (at the sole discretion of Transmitter Solutions) if the product does not operate correctly due to a defective component. This warranty does not extend to (a) the case, which can be damaged by conditions outside the control of Transmitter Solutions, or (b) battery life. This warranty is further limited by the following disclaimer of warranty and liability: EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING THE GOODS, EXPRESS OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO THE GOODS AND ACCEPTS THEM AS-IS/WHERE-IS. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING INJURIES TO PERSONS OR PROPERTY, TO BUYER, ITS EMPLOYEES OR AGENTS, AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF BUYER S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.