Model D D D D Part Number Extended Run Battery Cabinet

Similar documents
Security Plus Online Uninterruptible Power Supply

POWERVAR Sinergy III Rackmount / Tower User Instruction Manual. Sinergy III 120 Volt UPS. Sinergy III Volt UPS

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CR NEMA 3R

Liebert. APS UPS 5-20 kva Flexible, efficient scalable UPS for room or row-based applications

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Uninterruptible Power Supplies

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

G3PE-Single-phase. Solid State Relays for Heaters

A32 (UPS) UNINTERRUPTIBLE POWER SYSTEM ECN/DATE CPN /06 INSTRUCTION DRAWING NUMBER: Page 1 of 11 INSTRUCTIONS FOR A32 - UPS

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Liebert PowerSure PSI UPS

Sola 3000 Guide Specifications

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Totally Sealed Hour Meter

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

EATON 9315 UPS 200 TO 300 KVA Specifications

AT30 SERIES BATTERY CHARGER

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

American Power Design, Inc.

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Intelligent Engine Start Battery Charger. The Smart Choice for Mission-Critical Engine Starting

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Installation and Operation Manual. LD LED Dimmer

INTRODUCTION MARKET SECTORS CUSTOMER SERVICE CCL OFFERS YOU. Switchmode Technology A highly efficient, lightweight

Uninterruptible Power Systems

PG300 Data Sheet PG300 DATA SHEET

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

ATevo SERIES BATTERY CHARGER

AT EVO SERIES BATTERY CHARGER

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Electronics Cooling. Thermoelectric Coolers. Protective Cooling: Thermoelectric

3 Phase Power Systems - Designed for Canada

2 Uninterruptible Power Systems

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Uninterruptible Power Supply

AT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control

Airpax Dimensions, Inc.

THZ NEW - In Progress

Application. Battery. Public Grid GS HYBRID INVERTER

Microprocessor Controlled Float Battery Charger

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

CALL FOR A QUOTE (877)

Innovative Circuit Technology Ltd.

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

56 mm sq. (2.20 inch sq.)

Operating temperature (2, 3, 5) C -20 C to +70 C ( see derating curves) Storage temperature C -40 C to +85 C

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

PRODUCTS: POWER SUPPLY

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

E-Series and EF-Series Systems

PPS. MKP axial terminals snubber medium-high pulse applications high current high frequency switching. Ed. 04 Rev

Versatile and Rugged Industrial LIthium/LiPO Charger Series

EVO AT SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

XM2-HP and XM2 CableUPS

596 Rectifier Retrofit

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

Non-Spring Return EconoDrive Floating Actuator

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Power Inverter 400 MW Owner s Manual

Max. Input Power (W) Input Current V Isolated DALI

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

AT SERIES EVO BATTERY CHARGER

Specification of Soneil Battery Charger

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

Switch EDG/EDS SPST EDG/EDS DPST EDG/EDS SPDT EDG/EDS 3PST EDG/EDS 4PST EDG/EDS DPDT

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

NTC Thermistor:TTC05 Series

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

SECTION DC POWER SUPPLY/BATTERY CHARGER

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

SAV Electronic Valve Actuator

Minimum 18 in-lb Torque

Microprocessor Controlled Float Battery Charger

Go Power! Manual. GP-Smart Charger

1000mA - 650mA Phase Dimmable LED Driver

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Specification of Battery Charger

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Modulostar US10 Modular fuse-holders

NTC Thermistor:SCK Series

Transcription:

SIDE FRONT Model D9632-11 D9648-11 D9632-22 D9648-22 Part Number Typeform Extended Run Battery Cabinet INPUT (AC) BATTERY MISC. ENVIRONMENT Voltage (VAC) 120 240 Voltage Range (VAC) 90-132 180-266 Frequency (Hz) 50/60 Current (AC) 15.0 (Max) 8.0 (Max) Voltage (VDC) 96, nominal 109.2. float Battery 12V, 34W, flame retardant Quantity 32 48 32 48 Charge Current (ADC) 1.5A/string 1.0A/string 1.5A/string 1.0A/string Shipping Weight 413lbs. (187kg) 497lbs.(225kg) 413lbs. (187kg) 497lbs.(225kg) Unit Weight 368lbs. (167kg) 452lbs.(205kg) 368lbs. (167kg) 452lbs.(205kg) Dimensions A B C 29.0in (736.6mm) 11.8in (300mm) 31.7in (805.2mm) Temperature ( C) 0 to 40, operating -20 to 60, transit Altitude (m) 2,000, operating 12,000, transit Humidity 5.0% to 90.0%, non condensing Heat Dissipation (BTU/hr) 675.6 AGENCY Safety Agencies RoHS UL1778, 4 th ed. CSA22.2 No.107.1 All units are RoHS compliant

ABCDEF2000-11 Model: D9632-11 Model: D9648-11 ABCDEF2000-11 TYPICAL RUN-TIMES (MINs) 25% (450 W) 50% (900 W) 75% (1350 W) 100% (1800 W) Internal Batteries Only 20 13 10 7 Internal + 1) D9632-11 170 110 80 65 Internal + 2) D9632-11 375 250 190 140 Internal + 3) D9632-11 625 400 300 225 Internal + 4) D9632-11 >12 Hrs 575 400 300 Internal + 5) D9632-11 >12 Hrs >12 Hrs 575 450 Internal + 1) D9648-11 250 180 130 100 Internal + 2) D9648-11 625 400 300 230 Internal + 3) D9648-11 >12 Hrs 700 500 375 Internal + 4) D9648-11 >12 Hrs >12 Hrs >12 Hrs 575 Internal + 5) D9648-11 >12 Hrs >12 Hrs >12 Hrs >12 Hrs Note: Run-Times are based on new fully charged batteries at 25 deg C ambient. ABCDEF2000-22 ABCDEF2000-22 TYPICAL RUN-TIMES (MINs) 25% (450 W) 50% (900 W) 75% (1350 W) 100% (1800 W) Internal Batteries Only 18 12 9 7 Internal + 1) D9632-22 160 110 80 65 Internal + 2) D9632-22 325 230 180 140 Internal + 3) D9632-22 575 375 275 225 Internal + 4) D9632-22 >12 Hrs 575 425 325 Internal + 5) D9632-22 >12 Hrs >12 Hrs 550 425 Internal + 1) D9648-22 240 170 130 100 Internal + 2) D9648-22 575 375 275 225 Internal + 3) D9648-22 >12 Hrs 650 475 375 Internal + 4) D9648-22 >12 Hrs >12 Hrs >12 Hrs 550 Internal + 5) D9648-22 >12 Hrs >12 Hrs >12 Hrs >12 Hrs Note: Run-Times are based on new fully charged batteries at 25 deg C ambient.

ABCDEF3000-11 Model: D9632-11 Model: D9648-11 ABCDEF3000-11 TYPICAL RUN-TIMES (MINs) 25% (675 W) 50% (1350 W) 75% (2025 W) 100% (2700 W) Internal Batteries Only 40 24 17 12 Internal + 1) D9632-11 170 100 70 55 Internal + 2) D9632-11 325 200 140 110 Internal + 3) D9632-11 550 325 225 170 Internal + 4) D9632-11 >12 Hrs 450 310 230 Internal + 5) D9632-11 >12 Hrs 600 400 300 Internal + 1) D9648-11 250 150 100 80 Internal + 2) D9648-11 550 325 220 160 Internal + 3) D9648-11 >12 Hrs 525 350 250 Internal + 4) D9648-11 >12 Hrs >12 Hrs 525 375 Internal + 5) D9648-11 >12 Hrs >12 Hrs 700 525 ABCDEF3000-22 ABCDEF3000-22 TYPICAL RUN-TIMES (MINs) 25% (675 W) 50% (1350 W) 75% (2025 W) 100% (2700 W) Internal Batteries Only 35 23 15 12 Internal + 1) D9632-22 160 100 70 55 Internal + 2) D9632-22 325 200 140 110 Internal + 3) D9632-22 500 300 210 165 Internal + 4) D9632-22 >12 Hrs 425 300 230 Internal + 5) D9632-22 >12 Hrs 575 400 300 Internal + 1) D9648-22 230 150 100 80 Internal + 2) D9648-22 500 300 210 160 Internal + 3) D9648-22 >12 Hrs 500 350 270 Internal + 4) D9648-22 >12 Hrs >12 Hrs 525 375 Internal + 5) D9648-22 >12 Hrs >12 Hrs 675 500

ABCDEF4000-22 ABCDEF4000-22 TYPICAL RUN-TIMES (MINs) 25% (900 W) 50% (1800 W) 75% (2700 W) 100% (3600 W) Internal Batteries Only 25 17 11 8 Internal + 1) D9632-22 120 75 50 35 Internal + 2) D9632-22 250 150 100 75 Internal + 3) D9632-22 375 220 150 110 Internal + 4) D9632-22 550 325 210 160 Internal + 5) D9632-22 >12 Hrs 425 275 210 Internal + 1) D9648-22 170 110 75 55 Internal + 2) D9648-22 375 220 150 120 Internal + 3) D9648-22 625 375 250 185 Internal + 4) D9648-22 >12 Hrs 525 350 275 Internal + 5) D9648-22 >12 Hrs >12 Hrs 475 350 ABCDEF5200-22 ABCDEF5200-22 TYPICAL RUN-TIMES (MINs) 25% (1170 W) 50% (2340 W) 75% (3510 W) 100% (4680 W) Internal Batteries Only 20 11 8 6 Internal + 1) D9632-22 90 50 35 25 Internal + 2) D9632-22 170 100 70 50 Internal + 3) D9632-22 275 160 110 80 Internal + 4) D9632-22 375 220 150 110 Internal + 5) D9632-22 500 300 200 150 Internal + 1) D9648-22 130 75 50 35 Internal + 2) D9648-22 275 160 110 80 Internal + 3) D9648-22 425 250 170 130 Internal + 4) D9648-22 625 350 240 180 Internal + 5) D9648-22 >12 Hrs 475 325 240

ABCDEF6000-22 ABCDEF6000-22 TYPICAL RUN-TIMES (MIN) 25% (1350 W) 50% (2700 W) 75% (4050 W) 100% (5400 W) Internal Batteries Only 18 10 7 5 Internal + 1) D9632-22 80 45 30 22 Internal + 2) D9632-22 160 90 60 45 Internal + 3) D9632-22 240 140 95 70 Internal + 4) D9632-22 325 190 120 90 Internal + 5) D9632-22 450 250 160 130 Internal + 1) D9648-22 120 65 45 30 Internal + 2) D9648-22 225 140 95 70 Internal + 3) D9648-22 400 220 150 110 Internal + 4) D9648-22 550 325 210 150 Internal + 5) D9648-22 > 12 Hrs 425 275 200 UPS to BATTERY CONNECTIONS (1) Connection to (+) DC Terminal (2) Connection to (-) DC Terminal (3) Connection to AC Input to charger (*) Cable assemblies in diagram are shown broken for clarity. Warranty/Support: POWERVAR warrants the electronics and transformers used in its uninterruptible power managers to be free from defects in materials and workmanship for a period of three years from the date of shipment. Batteries are warranted for a period of two years from the date of shipment for standby use; 90 days for cyclic use. For North American service or support on any POWERVAR product, please contact POWERVAR Technical Support at (800) 369-7179 (in Illinois call (847-596-7000). For service and support in EMEA, contact POWERVAR, Ltd. in the United Kingdom at +44 (0) 1793 553980. Or visit the POWERVAR website at www.powervar.com. Battery Life Disclaimer: Powervar s standard battery warranty applies only to UPS and UPM products which are continuously connected to AC mains power, except during utility power outages. Products which are regularly and intentionally disconnected from AC mains power will experience battery discharge/charge cycles potentially far more numerous than those for which the battery was designed. As a result, products used in such applications will experience substantially reduced battery life. For that reason, Powervar s standard battery warranty does not apply for applications in which the UPS or UPM product is regularly and intentionally disconnected from AC mains power. Powervar UPS and UPM products used in such applications shall receive a 90 day warranty on batteries. POWERVAR, Inc. - 1450 Lakeside Drive, Waukegan, IL 60085 POWERVAR, Ltd. - Unit 5 Birch, Kembrey Park, Swindon, Wiltshire, UK SN2 8UU