AXS 215S: Continuous actuator for unit valves, with stroke indicator

Similar documents
AXT201, 211: Thermal actuator for unit valves, with stroke indicator

Control solutions Biofloor

AKM 105, 115: Rotary actuator for ball valve

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

AVM 215S-R: Valve actuator with SAUTER Universal Technology (SUT)

AVM 105, 115: Valve actuator

AVP : Pneumatic valve actuators

A44 W0...W2: Motorised actuator

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

BQE: 3-way flanged valve, PN 16

AVP : Pneumatic valve actuators

BUE: 3-way flanged valve, PN 16/10 (el.)

EGQ 212: Duct transducer, CO 2 and temperature

ADM 322: Rotary actuator

BUN: 3-way valve with male thread, PN 16

BUD: 3-way flanged valve, PN 6 (pn.)

AVM321, 322: Actuator SAUTER vialoq AVM 1000

VUD: 2-way flanged valve, PN 6 (pn.)

VA-707x. Thermal Valve Actuators. Product Bulletin. Low and line voltage models available

EMO TM. Actuators High performance proportional actuator For modulating control

Pushing 1) force. Motor Spring [N] [kg]

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Actuator type ABNM with Theft Protection, 0-10 V Proportional

Actuators for small valves

EMOtec. Actuators Thermal actuator for heating, ventilation, and air conditioning systems

EMO T. Actuators High performance thermoelectric actuator For ON/OFF or PWM control

SAX Electronic Valve Actuator

Actuators for Fire and Smoke Protection Dampers

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Connection. k VS -Value m 3 /h

HERZ Electronic room thermostat analog and digital

Actuators for Fire and Smoke Protection Dampers

Electrothermal actuators

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

Actuators for Fire and Smoke Protection Dampers

Control Solutions Biofloor

SSA955. Synco living Radiator Control Actuator

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Connection. k VS -Value m 3 /h

Current consumption Auxiliary switch. Angle of rotation 90 (internal electrical stops) Running time

Actuators for modulating control AME 110 NL, AME 120 NL

Actuators for heating, ventilation, air conditioning 2. LF-2 -CD. Product Information Damper actuators with spring return.

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Suitable to Johnson Controls and almost all of terminal unit valve on the market

Electronic Circuit Breaker ESS20-0..

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

CALEFFI. Motorised ball zone valves with 3-contact control BY series 01131/18 GB. replaces 01131/11 GB

HERZ Motorised Actuator

Remote-adjustable Radiator Controller HR 40 F. Mounting and Operation

Valves and actuators. SAUTER control units for all of your requirements.

MF /MS Series

24 V AC/DC, -10%..+20%, 0-60Hz. 250 ma for max 2 min

DuraDrive MF /MS Series Non-spring Return Rotary Electronic Damper Actuators 24 Vac Three-position/Modulating

VM-GIB High Torque Actuator (Non-Spring Return) 3-point floating (193B1790) / Modulating (193B1791)

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Electromotoric Actuators

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Fire and Smoke Damper Actuator product overview

Globe Valves. Technical Databook Version 1.2. Belimo Asia Pacific

HANDBOOK VALVES. Ed VALVES VR-ED 02/ ENG 1

Actuators for Fire Protection Dampers

Actuator ABNM A V Proportional For Use with RA2000 Valves

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Accessories STRA Room Controller

Type 231 ACTUATOR FOR DAMPERS. G R U N E R t h e. f r i e n d l y a l t e r n a t i v e. Actuator with rotation drive. 20 Nm 30 Nm

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Overview of types. Technical data. Safety notes

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

GDB..3..1A GLB..3..1A

JUMO MIDAS Pressure transmitter

Use. Functions. OpenAir TM. Rotary version, modulating, with spring return, AC 24 V

AEL5 Series Electric Linear Actuators for DN15 to DN100 Control Valves

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1 nominal torque 0.2 W 2 VA Auxiliary switch

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power Supplies. Power Supplies. PS5R Standard Series. PS5R Standard Series Switching Power Supplies

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

22C, 22CX, 22CX5, 26LC Series

B6R: 3-way valve with female thread, PN 16 (pn.)

Standard Interlock Safety Switches

Electric actuators for small valves

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Electrothermal actuators

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Power consuption motor (motion) Power consuption standby (end position) Position feedback Auxiliary switch Contact load Switching point

HL (AZH) LIMIT SWITCHES

Transcription:

AXS 215S: Continuous actuator for unit valves, with stroke indicator How energy efficiency is improved Reliable, precise actuation in efficient control systems Features Fitted to the valve using no force thanks to the Low-Force-Locking (LFL) connector Fitted onto the valve with M30 1.5 thread, with automatic adjustment of closing dimension With 24 V~ thermal expansion element and accurate continuous input Large, visible position indicator NC normally closed and NO normally open versions Choice of direction of operation, 0(2) 10 V or 10 (2)0 V and split-range function, 0 4.5 V or 5.5 10 V Position monitoring with inductive, non-wearing sensor; does not require periodic recalibration Silent and maintenance-free Modular electrical plug connection (various cable lengths and types) Connected to valve with plastic bayonet connection Suitable for retrofitting existing installations without an adapter Fitting in any position, including upside down AXS215SF122 Technical data Power supply Power supply 24 V~, ±20%, 50...60 Hz Power consumption during operation 3 W Starting power Max. 5 W Start-up current 220 ma Stand-by current Max. 6 ma Operating current Max. 90 ma Parameters Stroke Min. running time 1) Control signal 1 4.5/3 mm (can be selected) Approx. 30 s/mm 0...10 V, R i 100 kω Ambient conditions Operating temperature at valve 100 C Storage and transport temperature 25...70 C Admissible ambient temperature 0...50 C Admissible ambient humidity < 85% rh, no condensation Construction Weight Housing Housing material Power cable 0.21 kg High-gloss surface (FV-0 as per EN 60707 and V-0 as per UL94), pure white (RAL 9010) or jet black (RAL 9005) Fire-retardant plastic Standard length 2 m, H03VV, PVC or halogen-free, 3 x 0.22 mm², white or black Standards and directives Type of protection IP54 (EN 60529) Protection class 24 V III (EN 60730-1, EN 60730-2, EN 60730-14) CE conformity according to EMC Directive 2014/30/EU EN 61000-6-1/EN 61000-6-2 EN 61000-6-3/EN 61000-6-4 1) The total time for 100% stroke is approx. 3.5 4.5 minutes (warm-up time) in the cold state or approx. 150 seconds in control mode without a dead time, i.e. in stand-by mode, add a dead time of approx. 110 seconds Right of amendment reserved 2017 Fr. Sauter AG 1/7

Overview of types / Closing force in combination with SAUTER valves Type Closing force NC/NO AXS215SF122 115 N NC AXS215SF122B 115 N NC AXS215SF222 110 N NO AXS215SF222B 110 N NO A A AXS215SF122, AXS215SF222: White version, including M30 x 1.5 bayonet nut, cable 2 m, pack of one AXS215SF122B, AXS215SF222B: Black version, including M30 x 1.5 bayonet nut, cable 2 m, pack of one Accessories Connectors with continuous actuation (for 24 V AC version only) Type Description 0550423121 Continuous activation NC adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 2 m white cable, PVC 3 x 0.22 mm² 0550423221 Continuous activation NO adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 2 m white cable, PVC 3 x 0.22 mm² 0550423151 Continuous activation NC adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 5 m white cable, PVC 3 x 0.22 mm² 0550423251 Continuous activation NO adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 5 m white cable, PVC 3 x 0.22 mm² 0550423171 Continuous activation NC adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 7 m white cable, PVC 3 x 0.22 mm² 0550423271 Continuous activation NO adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 7 m white cable, PVC 3 x 0.22 mm² 0550423123 Continuous activation NC adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 2 m white halogen-free cable, 3 x 0.22 mm² 0550423153 Continuous activation NC adjustable: 0(2) 10 / 10 0(2) V, split-range unit 0 4.5 V or 5.5 10 V, for 4.5 mm or 3 mm stroke, 5 m white halogen-free cable, 3 x 0.22 mm² Various accessories Type Description 0550240001 Removal-protection device for AXT/AXS211 (prevents the unauthorised removal of the plug and actuator) Adapters & adapter sets Type Description 0550390101 Raised M28 1.5 bayonet nut (grey), with N-insert (normal, black) and S-insert (reduced, white), for all valves with M28 1.5 threads and angle valves or valves with measurement sockets; dimension of actuator 5 mm higher. Closing dimension depending on type of use: NC 4.5 mm to 18.5 mm and NO 8.5 mm to 22.5 mm, e.g. Pettinaroli 0550390201 Raised M30 1.0 bayonet nut (white), with N-insert (normal, black) and S-insert (reduced, white), for all valves with M30 1.0 threads and angle valves or valves of different manufacturers; dimension of actuator 5 mm higher. Closing dimension depending on type of use: NC 4.5 mm to 18.5 mm and NO 8.5 mm to 22.5 mm, e.g. Oventrop (up to 1997), Beulco (up to 2004) 0550393002 Adapter for fitting to Danfoss valves, type RAVL, 26 mm 0550393003 Adapter for fitting to Danfoss valves, type RAV, 34 mm 0550393004 Adapter for fitting to Danfoss valves, type RA 2000, 22 mm 0550394001 Adaptor for fitting to Giacomini valves, type R450, R452, R456 and range 60 0550399001 Adaptor set comprising: raised bayonet nut, black M30 1.5 (all manufacturers, M30 1.5); raised bayonet nut, grey M28 1.5 (all manufacturers, M28 1.5); raised bayonet nut, white M30 1.0 (e.g. Oventrop, Beulco); 2 N-inserts (black) and 2 S-inserts (white); Danfoss adaptor RA 2000 (Ø 22 mm); Giacomini adaptors Description of operation The actuator has an electrically heated expansion element protected against overload, which transfers its stroke directly to the attached valve. It operates noiselessly and is maintenance-free. If the heating element is turned on when it is cold (ambient temperature approx. 21 C), the valve begins opening after a warming-up time of approx. 2.4 min, and after an additional period of approx. 2.7 min. it has carried out a stroke of 4.5 mm. When the actuator is controlling, it moves to the desired stroke position depending on control voltage y. An adjustment (heating up) of 1 mm is performed in approx. 30 s and the stroke is monitored by an inductive sensor. The closing operation is practically symmetri- 2/7 Right of amendment reserved 2017 Fr. Sauter AG

cal to the opening operation in terms of time; the expansion element cools down and the valve is closed by spring force. Runtime behaviour Control mode Control signal (y) 10 9,8 9 8 7 6 5 4 3 2 1 0,5 0 Stand-by 0 1 2 3 4 5 6 Intended use Warming-up time Return time Dead time Actuator stroke (mm) Run-time Run-time (min) 4,5 4 3 2 1 This product is only suitable for the purpose intended by the manufacturer, as described in the Description of operation section. All related product regulations must also be adhered to. Changing or converting the product is not admissible. Stand-by mode The actuator switches to the stand-by mode when the control voltage is less than 0.5 V for direction of operation 1 or greater than 9.5 V for direction of operation 2. Running time (preparation) When it is cold, the actuator requires a warming-up time of approx. 2.4 min. The same time is also required when the actuator has been in stand-by mode for over 6 min. Running time (control) When the actuator is in control mode, the stroke of 4.5 mm is achieved in approx. 2.7 min. A change of 1 mm stroke (warming up) can be achieved within approx. 30 s. Depending on the setting of DIP switch 1 (see Setting the DIP switches), the continuous actuator can be used as 0...10 V (direction of operation 1) or 10...0 V (direction of operation 2). The control signal is then assigned linearly to the valve stroke. The integrated positioner controls the actuator according to positioning signal y. The continuous actuator positions the valve and, as soon as the position is reached, it stops. When the plug module is connected, the actuator takes over the factory settings of the electrical zero point. The first position detection (calibration) is performed when the actuator reaches stand-by mode for the first time. Here the mechanical zero point and the position tolerances between the position panel and the coil on the printed circuit board are also taken into account. Thus the current position is set as the new zero point. Due to the accuracy of the sensor, an adjustment within the stroke range is not required. To compensate for a possible shift of the mechanical zero point due to ageing in the soft seal of the valve plug, an automatic recalibration is always performed when the actuator remains in stand-by mode for 17 min. NC with direction of operation 1 DIP switch 1 is set to the OFF position. As the positioning signal increases, the actuator spindle moves in and opens the VUL or VUT 2-way valve with female thread or the control passage of the BUL 3-way valve with female thread. With the BXL 3-way valve with female thread, the control passage is closed and the mixing passage opened. NC with direction of operation 2 DIP switch 1 is set to the ON position. As the positioning signal increases, the actuator spindle moves out and closes the VUL or VUT 2-way valve with female thread or the control passage of the BUL 3-way valve with female thread. With the BXL 3-way valve with female thread, the control passage is opened and the mixing passage closed. DIP switch settings (NC and NO models) Switch 1 OFF 0...10 V Direction of operation 1 ON 10...0 V Direction of operation 2 Switch 2 OFF Stroke 4.5 mm ON Stroke 3 mm 4 Valve stroke (mm) 0 B11855 Right of amendment reserved 2017 Fr. Sauter AG 3/7

Switch 3 OFF Split-range unit off ON Split-range unit on Switch 4 OFF 0 4.5 V= 0 100% Switches to 4.5 0 V= 0 100 % when switch 1 is ON ON 5.5 10 V= 0 100% Switches to 10 5.5 V= 0 100 % when switch 1 is ON Switch 3 OFF 2 10 V= 0 100% Switches to 10 2 V= 0 100 % when switch 1 is ON Switch 4 ON Definition of NC/NO NC version normally closed After the actuator is fitted, the VUL/BUL valves (or standard radiator valves) are closed in the idle state or without a control voltage. When the control voltage is applied to the actuator, the actuator spindle moves in and the valve spindle moves out, and the valve is opened. Valve state with actuator without voltage: Closed NO version normally open After the actuator is fitted, the VUL/BUL valves (or standard radiator valves) are open in the idle state or without a control voltage. When the control voltage is applied to the actuator, the actuator spindle moves out and pushes the valve spindle, and the valve is closed. Valve state with actuator without voltage: Open Definition of the closing dimension NC version normally closed The closing dimension of a valve is the distance between the front surface of the spindle, pressed in with a preloading of < 100 N and the contact surface of the lower thread. The bayonet nut rests on this surface. NO version normally open The closing dimension of a valve is the distance between the front surface of the spindle when it is not pressed in and the contact surface of the lower thread. The bayonet nut rests on this surface. Cross-section of the unit valve NC NO Fitting 1 2 The actuator is fitted to the valve based on the Low-Force-Locking technique (LFL). When the actuator is removed from the valve, the closing dimension and the preloading are released again. The condition as delivered ex works is restored and the actuator can be used again with full LFL functionality. First screw the bayonet nut onto the valve and tighten it to 2 Nm. Then put the actuator onto the valve without any force. The openings on the bayonet ring show the suitable fitting position with respect to the three ribs on the bayonet nut. Turn the bayonet ring in the clockwise direction through an angle of rotation of 90 until the first click - the valve plug is preloaded. After the second click the actuator is ready for operation. This position is also the security position against loosening due to vibrations. 4/7 Right of amendment reserved 2017 Fr. Sauter AG

While the bayonet ring is being turned, the actuator automatically adjusts to the closing dimension of the valve. As the zero point of the valve is defined mechanically and the tolerances of the valve are compensated, it is possible to operate multiple actuators in parallel. To ensure problem-free operation with the NO actuator model, the compression spring in the valve must produce a force of F v 30 N. The actuator must not be removed when it is warm, as otherwise when it is mounted on a valve again, the closing dimension will not be set correctly any more. Closing dimension compensation The closing dimension is compensated mechanically. While the bayonet ring is being turned, the compensation pin in the actuator is released, and the built-in spring uses a force of min. 105 N in the locked state (after the second click ) to press it onto the valve spindle. Thus the closing dimension is set between the compensation pin and a compensation casing and is fixed by gear teeth. The gear teeth are designed so that the compensation pin automatically slots into the next row of teeth below. This ensures that there is always preloading on the valve plug and the valve is sealed. Valves can become permeable due to ageing or a defective plug seal. In this case, the bayonet ring can be loosened easily and then turned in the clockwise direction until the second click. The actuator has adjusted to the new closing dimension and the valve is sealed again. With the NO model, the compensation pin positions itself on the valve spindle without any force. Closing dimension compensation with normally closed (NC) When the standard bayonet nut supplied is used, the actuator can compensate a closing dimension of 8.5 mm to 13.5 mm. Closing dimension compensation with normally open (NO) When the standard bayonet nut supplied is used, the actuator can compensate a closing dimension of 12.5 mm to 17.5 mm. Closing dimension compensation with raised bayonet nut (accessory) The raised bayonet nut is used if the diameter of the bayonet ring on the actuator of 42.5 mm prevents the fitting (e.g. in angle valves, valves with measuring connection pieces or underfloor heating distributors). The standard closing dimension named above is achieved when the raised bayonet nut is combined with the N-insert (normal, black). When the raised bayonet nut is combined with the S- insert (reduced, white), the closing dimension is reduced by 5 mm. When the raised bayonet nut is combined with the valve without an insert, the closing dimension is increased by 5 mm. Closing dimension range for various bayonet nuts Bayonet nut Raised Standard Raised Raised M30 1.5 (thread on valve neck) M28 1.5 (thread on valve neck) M30 1.0 (thread on valve neck) Yes, black Yes, black Yes, black Yes, black Yes, grey Yes, grey Yes, grey Yes, grey Yes, white Yes, white Yes, white N-/S insert S (reduced, white) Not required N (normal, black) No insert Closing dimension range NC (mm) Closing dimension range NO (mm) Position indicator 4.5 9.5 8.5 13.5 8.5 13.5 13.5 18.5 8.5 13.5 12.5 17.5 12.5 17.5 17.5 22.5 The cover is used as the biggest possible position indicator. It is clearly visible from all positions and can be felt in the dark. With the normally closed (NC) model, the cover rises and the grey lifting part becomes visible. With a full lift, the cover is up to 5 mm above the top edge of the plug. With the normally open (NO) model, the cover falls until it is level with the top edge of the plug. The grey lifting part is no longer visible. Modular plug module; modifying types The actuator gets its type function from the plug, i.e. the basic function of the basic device remains unchanged. This has a number of advantages, e.g. after it has been delivered and used, the actuator can be converted into a new device at a later point in time. All that is required is to put the new type plug on the bottom part of the housing and if necessary an accessory part on the lifting part. Right of amendment reserved 2017 Fr. Sauter AG 5/7

) Note The voltage compatibility of the plug module with the related actuator must be checked before fitting. The following modifications are possible: 2-point model with auxiliary contacts and vice versa 2-point model with continuous 0...10 V and vice versa, only with 24 V power supply Continuous 0 10 V model in auxiliary contacts (position panel must be removed first and replaced with switching cam) ) Note The model with auxiliary contacts cannot be converted to the continuous model due to the switching cam that cannot be removed. The plug module can be removed from the actuator without a tool by pushing it by hand (up to approx. 30 N). Engineering and fitting notes When selecting the mains fuses, the start-up current of the heating element must be considered. To adhere to the specified technical data, the voltage loss due to the electric lines must not exceed 10 %. Accessories Removal protection The removal protection consists of two half-shells that are fitted around the actuator. When these halfshells are closed, they can only be removed by destroying them. The removal protection prevents the actuator from being removed from the valve, the electric plug from being removed and the DIP switch from being adjusted. The position indicator remains easy to see and touch. Connection diagram MM LS y = 0-10V BU = blue BN = brown RD = red BU BN RD 1 2 3 R 6/7 Right of amendment reserved 2017 Fr. Sauter AG

Dimension drawing 61 Ø 44 5 h (max) h (min) Ø 42,5 Accessory 0550390*01 h (min.) h (max.) NC 59 66 NO 59 64 k 66.5 73.5 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-controls.com Right of amendment reserved 2017 Fr. Sauter AG 7/7