Gen2 Regen Upgrade Xizi Otis, April 2010 1
Summary Gen2 Regen 1000kg,1.75m/s configuration upgrade Controller and drive upgrade to ACD2 MRL E&I panel change to mini size Introduce OTIS PM door operator NGSOK as Standard door operator Layout changes accordingly Gen2 Regen extended to 2000kg, 1.75m/s Added Regen function to 1150~2000kg as standard Introduced Otis optimized Gen2 machine Introduced OTIS E3 qualified HN6000 progressive safety Other configuration (Controller& drive, E&I panel, door operator) as per Gen2 Regen 1000kg Gen2 (1150~2000kg up to 1.75m/s,Non-regen) completely phase out Note: Gen2 Regen up to 2000kg is officially sales release on April 1st 2010 and Gen2 sales phase out at the same time
Configuration Upgrade Gen2 Regen 1000kg configuration upgrade Gen2 Regen extended to 2000kg to replace GeN2
Machine Upgrade GeN2 GeN2-Regen ABA20220AS ABA20220BD Apply to 1150kg to 2000kg Gen2 Regen only - OTIS optimized Gen2 Machine from the same supplier as GeN2 - Noise and vibration performance is improved - Otis Optimized Gen2 machine for 1000kg will be introduced later once it s available
Controller Upgrade GeN2 &Previous Gen2 Regen up to 1000kg GeN2-Regen -OTIS global new controller for MRL product -More compact - OH-CONB604B MRL will be phase out OH-CON4424 (For GeN2) OH-CONB604MRL(for previous Gen 2 Regen up to 1000kg) ACD2-MRL Controller Apply to 630kg to 2000kg Gen2 Regen
Regen function is added GeN2 &Previous Gen2 Regen up to 1000kg GeN2-Regen -OTIS global integrated regen drive for MRL - More compact Non-Regen drive(oh-con4424) Otis Regen drive for previous Gen2 Regen up to 1000kg ACD2 MRL regen drive - OH-CONB604B MRL will be phase out Apply to 630kg to 2000kg Gen2 Regen
E&I PANEL Upgrade GeN2 & Previous Gen2 Regen up to 1000kg GeN2-Regen Min E&I PANEL Apply to 630kg to 2000kg Gen2 Regen
Door Operator upgrade GeN2 &Previous Gen2 Regen up to 1000kg GeN2-Regen Apply to 630kg to 2000kg Gen2 Regen STD: AT120 STD: NGSOK - NGSOK is OTIS global PM operator - DO2000 is still optional
Safety Gear Upgrade GeN2 GeN2-Regen STD:9672D/E STD:HN6000B/C Apply to 1150kg to 2000kg only - HN6000B/C are OTIS global E3 safety components - Bigger running clearance. Ride quality is improved and false tripping is eliminated - 9672D/E are still optional
Layout Changes
New Controller & Drive Architecture Previous Gen2 Regen (OH-CONB604MRL controller) GeN2-Regen (ACD2 MRL) GeN2(OH-CON4424 Controller) 630kg~2000kg New arrangement is easier for controller and drive inspection
E&I PANEL cutout size GeN2 GeN2-Regen Apply to 630kg to 2000kg Gen2 Regen Top floor Min E&I PANEL size reduced, the cutout 1600(H)x250(W).
New Bracket Spacing for top floor GeN2 Gen2-Regen Top floor brackets Apply to 630kg to 2000kg Gen2 Regen -Stronger rail bracket made machine more stable - Noise and vibration is improved
Back up
ACD2 MRL Introduction
PRODUCT DESCRIPTION Integrated Regen controller Improve aesthetics and performance OTIS WWE (World Wide Engineering) lead design OTIS global source and SSI management Drive E&I Panel Controller 210W x 540H x 90D 320W x1300h x 160D
Duty Table
Controller Operational Parameters Feature Values Feature Values Baseline Product GCS -EN Max Speed (m /s) 1.75 Operation Control Max 8 Car Group Max Duty (kg) 2000 Drive Door OVFR2B-402,403,404, OVFR1A-406 NGSOK/AT120/AT400 /DO2000 Maximum # of Stops Maximum # of Opening 24 32 LWD Analog LWD Service Tool OTIS SVT Machine Opt. GeN2 Rescue operation MRO* Position Reference Max Rise (m) Photo-sensor 75 Note: MRO function is standard. ARO function should be offered as an optional function after June 2010.
Performance Parameter Min. Floor Distance (mm) Max Floor Distance (m) Maximum Acceleration (PMT measurement: m/s 2 ) Maximum Jerk (PMT measurement: m/s 3 ) Maximum Starts Per Hour Speed Tolerance (%) Stopping Accuracy (mm) Typical/Maximum Max In Car Noise (db), Fan Off Noise at Top landing with door closed. (db) Max Vertical Vibrations (mg) @ normal speed Target 350 @ 1.0m/s 500 @ 1.5m/s ~1.75m/s 11 <1.2 1.0 150@1.0m/s 180@ 1.5m/s ~1.75m/s, 40% duty cycle ±5 ± 3/ ± 5 52 Average 52 A95,11 PK-PK,14
Power Supply System Requirement Supply Voltage Frequency 380/400/415/440Vac ±10% 50/60Hz ±2Hz Note: TN-S (five wires net = 3 phases +neutral +earth) For 220/460V power supply, there need an extended additional transformer in system.
Application Environment Max Elevation: 1000m: full performance 2000m: Reduced performance(1% of rated running current per 100m) Operating Humidity 95% non-condensing Operating Temperature range (machine room): 0~45
Product Advantages Operational controller based on GECB (Global Elevator Control Board) + Motion controller based on GDCB (Global Drive Control Board) CAN-bus communication interface between operational and motion controllers External system interface following global SIMBA Energy effectiveness from the regenerative drive Mini E&I Panel Easily expandable computing core with high-speed 32bit CPU