CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

Similar documents
CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

General technical data. Ambient conditions

3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms

3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

AF40... AF96 3-pole contactors Technical data

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Essential equipment for all your requirements

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

MS General Information Extended Product Type: MS

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

W Datasheet: DIN Rail Contactors, series AMPARO

TAE pole Contactors

SIRIUS 3RU2 Thermal Overload Relays

Application Mini Contactors for Motors and Resistive Loads

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Protection Equipment

B Mini Contactor V Hz

Bulletin 193-T1 Bimetallic Overload Relays

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

For Info: Phone: Fax:

Industrial Contactors CTX 3 3P 185A - 800A

AE 9... AE 40 Contactors NE... Contactor Relays

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

D509E. Manual Motor - Starters

3 - Protection components Motor circuit-breakers

3RT14 Contactors with 3 Main Contacts

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Technical specifications

Protection Equipment. 5/2 Introduction

SIGUARD Safety Systems Safety Integrated

Mini contactors B6, BC6 with 3 pole

SIRIUS 3RV2 motor starter protectors. Electrical Components for the Railway Industry

3SE3 1 SIGUARD Position Switches

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Electrical Components for the Railway Industry. SIRIUS 3RV2 motor starter protectors

Single foot switches PX and PA series

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Description. Positive safety relays

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Thermal Overload Relays - WEG RW Series, 2 Pole

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Components for EEx e Panels

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

K50H004UP cam changeover switch - 4-pole A - screw mounting

Micro Contactor MA Series

BC Mini Contactor VDC

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

4 - Miniature controls

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Manual. Industrial Controls. Protection Devices. SIRIUS 3RV Motor Starter Protectors. Edition 12/2017. siemens.com

Short form catalogue. Motor protection & control

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Safety Switches with Separate Actuator SKC

Quick selection table

Special Purpose Fuses

Vehicle inlet - EV-T2GBIE12-1ACDC-20A125A2,0M

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

SWITCH FUSES 3KL71 from 32A to 800A Description

Safety Limit Switch

Electronic overload relays EF205 and EF370

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Application Description

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Microswitches M series

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

SIRIUS 3TH4 contactor relays with 8 and 10 contacts. Electrical Components for the Railway Industry

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Selection Guide Motor Control Device Solutions

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

SENTRON Switching and Protection Devices Switch Disconnectors

Meta Solution. Contactors and Overload relays

3TM Vacuum Contactors

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Transcription:

Product data sheet CONTACTOR, AC-3 7.5 KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION General details: Product brand name Product designation Size of the contactor Protection class IP / frontal/front side SIRIUS power contactor S0 IP20 Degree of pollution 3 Installation altitude / at a height over sea level / maximum m 2000 Ambient temperature / during the operating phase C -25 60 Real loss power / per conductor / typical W 0.9 Item designation according to DIN EN 61346-2 according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 Q K Mechanical operating cycles as operating time of the contactor / typical 10000000 of the contactor with added auxiliary switch block / typical 10000000 of the contactor with added electronics-compatible auxiliary switch block / typical 5000000 Main circuit: Number of poles / for main current circuit 3 Page 1/ 5

Number of NC contacts / for main contacts 0 Number of NO contacts / for main contacts 3 Operating current / at AC-1 / at 400 V / at 40 C ambient temperature / rated value Operating current / at AC-1 / at 400 V / at 60 C ambient temperature / rated value A 40 A 35 Operating current at AC-3 / at 400 V / rated value A 17 with 1 current path at 110 V / rated value A 4.5 at 24 V / rated value A 20 at 110 V / rated value A 2.5 with 2 current paths in series at 110 V / rated value A 15 with 3 current paths in series Service power at AC-1 / at 400 V / rated value kw 23 at AC-2 / at 400 V / rated value kw 7.5 at AC-3 at 400 V / rated value kw 7.5 at 500 V / rated value kw 10 at 690 V / rated value kw 11 Control circuit: Design of activation of the operating mechanism Type of voltage / of the controlled supply voltage conventional DC Control supply voltage / 1 Page 2/ 5

for DC rated value V 24 Auxiliary circuit: Contact reliability / of the auxiliary contacts 1 faulty switching per 100 million (17 V, 1 ma) Number of NC contacts / for auxiliary contacts instantaneous switching 0 lagging switching 0 Number of NO contacts / for auxiliary contact instantaneous switching 0 leading switching 0 Operating current / of the auxiliary contacts at AC-12 / maximum A 10 at AC-15 at 230 V A 6 at 400 V A 3 2 at 60 V A 6 at 110 V A 3 at 220 V A 1 3 at 24 V A 10 at 60 V A 2 at 110 V A 1 at 220 V A 0.3 Short-circuit: Design of the fuse link for short-circuit protection of the auxiliary switch / required fuse gl/gg: 10 A for short-circuit protection of the main circuit at type of coordination 1 / required at type of coordination 2 / required fuse gl/gg: 63 A fuse gl/gg: 25 A Installation/mounting/dimensions: Type of mounting series installation screw and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022 Yes Width mm 45 Height mm 85 Depth mm 101 Distance, to be maintained, to earthed part / sidewards mm 6 Page 3/ 5

Connection type: Design of the electrical connection for main current circuit for auxiliary and control current circuit screw-type terminals screw-type terminals Certificates/approvals: General Product Approval Functional Safety / Safety of Machinery CQC KETI ROSTEST SUVA Test Certificates Manufacturer Shipping Approval ABS Shipping Approval Manufacturer Further information: Information- and Downloadcenter (Catalogs, Brochures, ) http://www.siemens.com/industrial-controls/catalogs Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall CAx-Online-Generator http://www.siemens.com/cax Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/ww/view/en//all Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams,...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb= Page 4/ 5

last change: Sep 20, 2010 Page 5/ 5