GS Series. with new controller SM30

Similar documents
L6W - L8W - L10W - L12W Series LOWARA REWINDABLE MOTORS

The ResiBoost allows a constant set pressure regardless of demand for maximum comfort. Energy savings are the result of the precise speed control.

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

LNT..H with HYDROVAR (HVL range)

LET S CHANGE THE WAY WE SPEAK EFFICIENCY

HYDROVAR INCREASED FLEXIBILITY AND CONTROL WITH NEW GENERATION

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

AquaBoost Packaged Systems

VARIABLE SPEED WATER BOOSTER SETS WITH MULTISTAGE VERTICAL ELECTRIC PUMPS FLOW RATES UP TO 400 m 3 /h. 50 Hz GHV30 GHV40 SERIES

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

33GS, 40GS, 55GS, 60GS, 75GS & 80GS GPM, 1 10 HP, 60 HZ, SUBMERSIBLE PUMPS

TECHNICAL BROCHURE B45-70HB R2 45HB, 70HB HIGH PRESSURE CENTRIFUGAL BOOSTER PUMP

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

A-C Fire Pump. Fitting and Accessories A-C 100A

Hydrovar and Packaged Hydrovar

Flygt 3153, 50Hz. Technical Specification

Flygt 2600 sludge pump series. Maximize uptime with versatile submersible pumps

SRC 311. Technical Specification

PUREFLO 21 4-CHAMBER DIAPHRAGM PUMPS

Flygt propeller pumps. For cost-effective transport of large volumes

(.LOWARA. a xylem brand

GB REPAIR PARTS REPAIR PARTS RGB R3

PARTS LIST CP-210-PL. Series e Close Coupled Centrifugal Pumps. Replacement Parts

Flygt low-speed mixers. outstanding efficiency

Pure Performance FLYGT 1300 SERIES

Multistage Pumps. Vogel Series P, PVa, MP 300

CP-506B-PL. Series HSCS. Horizontal Split Case Pumps. Replacement Parts

Endsuction Pumps. Vogel Series LS, LC, LCP

Pure performance STEADY 1300 SERIES

WELCOME THE 5 TH GENERATION HYDROVAR HYDROVAR FROM XYLEM HAS BECOME THE NAME OF CHOICE FOR CONTROLLING THE EFFICIENCY OF FIXED SPEED PUMPS.

GB REPAIR PARTS REPAIR PARTS RGB R2

TECHNICAL BROCHURE BCP3PH R9. Three Phase 4" Motors, ½-10 HP 60 HERTZ, 3450 RPM

Aquavar ABII TECHNICAL BROCHURE BAQUABII R2 VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

RVS-DN Digital Reduced Voltage Motor Starter

TECHNICAL BROCHURE BC3WIRE-G2 R4

Flygt low-speed mixers OUTSTANDING EFFICIENCY

Flygt 2600 sludge pump series MAXIMIZE UPTIME WITH VERSATILE SUBMERSIBLE PUMPS

Booster Sets. AQUA Domus AQUA Profissional AQUA Master AQUA Premium

Flygt Parts List

TECHNICAL BROCHURE BAC2000. Series 2000 Closed Coupled. Series 2000 Frame Mounted. Series A-C 2000 SINGLE STAGE END SUCTION

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

ADJUSTABLE FREQUENCY CRANE CONTROLS

Variable Speed Product Line

PRESSURE BOOSTER SETS WITH TRANSDUCER CONTROL COMPACT, ROBUST, HIGH HYDRAULIC PERFORMANCE, PIPELINES IN AISI 304 STAINLESS STEEL. each pump etc.).

NPE/NPE-F REPAIR PARTS REPAIR PARTS RNPE R1

TECHNICAL BROCHURE BHSJ. Basic Convertible Pump HSJ MULTI-STAGE CONVERTIBLE JET PUMPS - 60 HZ

Multistage Pumps MP, MPA, MPB, MPV SIZES DN 40 - DN 125

VASCO. Variable Speed Controller ENGLISH

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Flygt compact mixers. reliable versatility, high efficiency

6" Single Phase Motors 6-10" Three Phase Motors

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

Blockpumps. Vogel Series LSB WITH HYDRAULICS ACCORDING TO ISO 2858

Series 8150 Replacement Parts for 8150 Series Fire Pumps PARTS LIST CP-608B-PL

RVS-DX Digital Reduced Voltage Motor Starter

TECHNICAL BROCHURE BAQUACPC. Aquavar CPC VARIABLE SPEED CENTRIFUGAL PUMP CONTROLLER

50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES. Cod.

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

McDonnell & Miller Service Parts Catalog PARTS LIST MM-701D

825-P Modular Protection System for motors Specification Guide

REPAIR PARTS R36/3756 R /3756 S, M & L-Group REPAIR PARTS

Flygt Parts List

Flygt Parts List

AUE-AUD-AU2E AU2D-AUED

HVAC Products. Introducing the SED2 Variable Frequency Drives

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

SPEEDRIVE INSTRUCTIONS MANUAL

Series e-60. In-Line Mounted Centrifugal Pumps Maintenance Free Replacement Parts PARTS LIST CP-107-PL

Domestic. Pump Series CS Condensate Units SINGLE OR DUPLEX 1,000 THRU 150,000 SQ. FT. EDR-250 THRU 37,500 LB./HR.

PART LISTS D-421G-PL. Domestic Pump. Series B35 REPLACEMENT PARTS FOR. 2 ft. NPSH Centrifugal Pumps Styles PF and PVF and HB-35

BoosterpaQ Hydro MPC-ED Guide Specification


Volute Casing Pumps LSN. according to iso 2828 / ISO 5199

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

ECU1000 ELECTRONIC CONTROL UNIT

Marlow Series Prime Line

hydro unit booster systems

Constant Pressure Guaranteed Pressure boosting for water supply in commercial buildings

EBARA. System PUMP W. Uniquely EBARA Variable Speed (VFD) System. Custom built for ideal water supply system... EBARA. System DIMENSION APPLICATIONS

PowerCommand 2100 digital generator set control

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

HYDRO BOOSTER RANGE HYDRO MULTI-S HYDRO MULTI-B CME HYDRO MULTI-B CR HYDRO MPC

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

Series e-1510 REPLACEMENT PARTS FOR STANDARD DESIGN PUMPS PARTS LIST CP-208G-PL

Teknospeed Inverter Diagrams and Drawings

1. Product Information

ECONOMISER SERIES E2T USER MANUAL

One step forward. Multi-pump and Multi-function control panel

AT EVO SERIES BATTERY CHARGER

Pressure Boosting Systems Multiple-Pump Units

Engineering & Expertise Transient Analysis

50 Hz. GS20-GS21-GS30 Series. FIXED-SPEED PRESSURE BOOSTER SETS WITH VERTICAL MULTISTAGE ELECTRIC PUMPS e-sv SERIES. Cod.

EVO AT SERIES BATTERY CHARGER

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

NPE/NPE-F REPAIR PARTS REPAIR PARTS RNPE R5

50 HZ. Ready DURABLE, LIGHTWEIGHT AND EASILY SERVICEABLE SUBERSIBLE SUBMERSIBLE PUMPS.

ALTI-NEXIS V OPERATING LIMITS APPLICATIONS ADVANTAGES. Flow rates up to: 320 m 3 /h Delivery head up to: Maximum operating pressure:

Grundfos pressure boosting systems

Transcription:

GS Series Sensorpress Booster Systems with new controller SM30

GS Series The GS range of fixed speed booster setsincludes models with 2 to 3 electric service pumps, and an additional jockey pump able to adapt to specific requirements within different applications. The start and stop of the pumps is based on the pressure values set on a pressure transducer, in order to deliver the water required. One pressure transducer is connected on the delivery side of the set. A second one is connected but only as a reserve device. With the cyclic changeover function, duty assignment is rotated to ensure both pumps remain active and with even running hours, so wear is uniform and the use factor is reduced for longer pump life. This system also ensures continuity of operation, in case one of the pumps needs maintenance. The electric pumps used in the GSD range are FHE and SHE series and SV series vertical multistage pumps.pumps are controlled by an electric control panel with a new electronic card with display on the front door. The electronic card and panel can also be used for waste water applications with up to 3 pumps installed. Benefits. Water supply and waste water applications Multilanguage menu with 8 languages Start and stop of the pumps on level or pressure value (contact or analogical signal) Pumps rotation on running time or pump start Modbus serial interface Specifications. Booster sets with SV series vertical multistage pumps with the following performances: Booster sets with FH and SH series end suction pump with the following performance: Maximum operating pressure: Configuration of the electronic card and its functionality can happen in the following ways: Digital inputs and outputs Analogical inputs and outputs Autotest by timer Max flow: up to 300 m³/h Head: up to 160 m Max flow: up to 540 m³/h Head: up to 160 m 16 bar by panel with function key by RS 485 setting modbus registers Power General fault Low/high level Pump 1 run Pump 2 run Pump 3 run 02 03

Input/output specification. Dielectric strength control board is applied on three sides: power supply digital input/output analogical input/output, CPU, RS485 Digital input N 6 digital inputs come from float switches or pressure switches N 3 digital inputs come from motor protections or PTC Input for probes detection circuit (common, minimum, maximum) with adjustable sensibility or float switch or minimum pressure switch. Digital output N 3 digital outputs relays, for pumps control N 1 output relay for alarm signalling activation N 1 output 12 V for alarm siren Analogical input N 2 analogical inputs with the following characteristics: Input type 0-20 m A, 4-20 m A, 0-10 V selected by software Analogical output Output type 0-20 m A, 4-20 m A, 0-10 V selectable by software Applications. These kinds of booster sets are used for water supply applications, in the following facilitie. Commercial building Schools Offices Hotels Public and private healthcare systems Industrial premises Public buildings Theatres Camping Booster sets components and material. Booster sets are manufactured in a compact solution with all components assembled in the factory. Booster sets have the following components: Base in iron painted Ω shape Vertical multistage pumps or horizontal pumps SV and FH, SH series Control panel with electronic card SM30 Isolating valve nickel-brass or cast iron material Check valve in suction side or delivery side according to customer requirements Pressure transducers in AISI 304 one in run and one in stand-by Pressure gauge Delivery manifold in AISI 304 Suction manifold in AISI 304 All the sets are tested in the factory and they are manufactured according to: Machinery Directive: 2006/42/CE Low Voltage Directive: 2006/95/CE Electromagnetic Compatibility Directive: 2004/108/CE The following Input/Output (I/O) are also specified: N 3 micro switches on the electronic card to manage its by-pass and to directly control the pumps in case of a fault in the electronic card. Micro switches have three positions (on, auto, off) and they will skip the output relay signal for contactors direct control. N 1 RJ45 connector for output on electronic card. Lowara RILS6 (free contacts electronic card) is configurable by electronic card SM30. Modbus serial interface. The electronic card has a serial interface RS485. It will be managed by microprocessor with Modbus protocol. 04 05

Autotest Alarms. The following alarms can be set in the main menu: Thermal overload Dry running protection Pressure transducer in fault Autotest in fault Periodic Autotest. In systems subjected to long periods of inactivity, it is possible to use an electronic internal clock or an external device to enable aperiodic autotest (the time period recommended is bi-weekly). The test phase lasts one minute. If during this phase the diaphragm pressure switch is in run, an alarm will be on. The other pumps are started in order to re-establish the pressure. High pressure Low pressure Outside of operating range Latest alarms are recorded in the electronic card memory, and they are visible in the alarms historic menu. In case of alarm due to the diaphragm pressure switch (not during autotest, but during the normal function) the electronic card is set with a time delay to enable all the pumps for re-establish the pressure value. When the alarm stops, all the pumps will be turned off and the alarm will be recorded. It is possible to set the following parameters before the start up of the systems: Total number of pumps in the set (max 3 pumps, jockey pump included) Jockey pump (yes or no) Control by pressure switches or pressure transducer Autotest yes or no, and control by internal timer or external device (AUX1) Friction losses compensation and threshold increase Two different situations: Diaphragm pressure switch in action outside of operating range alarm in run; in this case there could be an error in the electric connection with the pressure transducer, or in the value set. Outside of operating range alarm in run (with pumps in run according to pressure transducer); in this case one or more pumps may not be working efficiently. Night and Day function. The booster set provides night and day pressure sets, giving it two different methods of use for different applications in the same system. The value set can be set directly by electronic card or by an external input (EXT3). Activation of pump rotation, according to On/Off of the pumps, or by running time with a clock counter Enable pump stop delay for each pump or all pumps Enable reduced times for fast variations (dynamic delay) 06 07

The Xylem Lowara GS booster systems are equipped with SV series vertical multistage pumps. These high efficiency pumps with EFF1 motors offer higher efficiency and energy savings. Thanks to the reliability and efficiency of the SV range of multistage centrifugal pumps, combined with the new controller SM30, we can provide the best solution for our booster systems. Reliability and efficiency SM30 controller. If the brain of Sensorpress booster systems is the SM30 controller, then SV vertical multistage pumps are the heart of the booster sets. High-tech pumps and high efficiency motors give Sensorpress booster systems the highest level of quality. The SV pumps used in the Sensorpress booster systems are easy to install and to replace. Thanks to their simple maintenance, the mechanical seal can be replaced quickly without removing the electric motor. High level of performance, high efficiency, stainless steel technology and a wide range of models enable many booster system combinations for any application. Multi-pump control ensures a balanced system, with drive rotation for each pump. With the high quality level of Xylem Lowara motors fitted on SV pumps, the Sensorpress booster system ensures low noise and the best comfort for all users 09

Smart system and guaranteed performances UPPER LOWER 1 pump Increase 2 pump 3 pump Variables thresholds for friction losses compensation Friction losses compensation. In water systems it is normal to have a decrease of pressure due to the pressure drop with increasing flow rate value. In order to compensate friction losses, it is possible to enable a control that gives a pressure proportional value to the load of the system. Direct measurement of the flow is not detected. We believe that it is proportional to the number of pumps running. Pressure value set (upper and lower threshold) is incremented by a value set in the parameters. The jockey pump is not considered. The new SM30 controller was born from the experience of Lowara in pump technology and knowledge of automatic pump control. Development of the SM30 controller involved all our know how to be sure that it satisfies all users requirements. Through the SM30 we will improve the performances of our booster systems and its user-friendliness. The menu navigation is very simple and step-by-step operation ensures users can set the main parameters and obtain best performance from the booster system. UPPER LOWER Pressure UPPER THRESHOLD LOWER THRESHOLD Pressure Delay OFF T/2 Margin Static Delay OFF Stop pump Pump stop static Inclination reference Delay Pump stop dynamic Start pump Time Time System with pressure transducer. The value of pressure detected, below the minimum threshold, enables the first pump available. The value of pressure detected, above the minimum threshold, disables the last pump running. Delay times at startup, and stop, allow sufficient hysteresis. The delay time of the starting up of the first pump (with all other pumps stopped) may be different from other pumps, so as to limit the pressure drop (very short delay time). Dynamic times. Water consumption causes a pressure change in the system. To maintain the value of pressure, the pumps start and stop within the limits set. Delay times are needed to allow the pumps to get maximum speed, and avoid oscillations (continuous starts and stops). The best adjustment of delay time must be made according to the type of pump and starter type (D.O.L, star delta, soft start ). To obtain the best performance from the system, with both slow and fast changes, you must change the delay time in a dynamic way. 11

What can Xylem do for you? Xylem /'zīl m/ 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We re 12,000 people unified in a common purpose: creating innovative solutions to meet our world s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to xyleminc.com. www.xyleminc.com LOWARA S.r.l. Unipersonale Via Dott. Lombardi, 14 36075 Montecchio Maggiore Vicenza - Italy Tel. (+39) 0444 707111 Fax(+39) 0444 492166 e-mail: lowara.mkt@xyleminc.com www.lowara.com completewatersystems.com cod. 191000471 - P03/12 Lowara is a trademark of Xylem Inc. or one of its subsidiaries. 2011 Xylem, Inc.