Cubic unit cooler. SKB semi-industrial range

Similar documents
Cubic unit cooler. SKB semi-industrial range

MUC-LUC. Unit Coolers. 1 kw 13,7 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

Küba SG industrial

Unit Coolers MUC-LUC. 1 kw 13,7 kw.

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

Condensers. 7 kw 198 kw.

Heat Exchangers. Evaporator Catalogue

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Making refrigeration greener KELVION KME COMMERCIAL AIR COOLER

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Low Profile Unit Coolers

MAKING REFRIGERATION GREENER

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

Dual discharge air coolers THOR-D. Standard coolers in a revolutionary design

Industrial air coolers for cooling & freezing applications Cu/Al

Alfa Laval Optigo CC. Commercial air coolers - Single discharge. Extended range featuring draw-through & blow-through models

fåçìëíêá~ä=~áê=åççäéêë=qelo pí~åç~êç=åççäéêë=ïáíü=`ì=íìäáåö

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER

Medium Profile Unit Coolers

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Alfa Laval Optigo CC. Commercial air coolers - Single discharge

COMMITTED TO ENGINEERING INNOVATION

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Alfa Laval Optigo CS. Commercial air coolers - Slim line

BREEZE. The new angled air cooler AIR HEAT EXCHANGER MANUFACTURER. stefani-online.it

Center Mount Unit Coolers

Airsock unit coolers THOR-A. Standard coolers in a revolutionary design

Goedhart FC38. Standard air coolers Cu/Al. R404A - Coolants. engineering for a better world. GEA Heat Exchangers. Goedhart FC38S.

Large Profile Unit Coolers

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Nomenclature. Table of Contents. BH A 850 C P A Vintage

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

HEATING & COOLING COIL PRODUCTS

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

MEDIUM PROFILE UNIT COOLERS Technical Guide

Fan coil units MAJOR 2 CV/CH

Industrial air cooler VCI Cooling/Freezing

AHN 064 to 304 EHN/CHN 064 to 304

CATÁLOGO TÉCNICO COMERCIAL

Industrial air coolers THOR. Standard coolers in a revolutionary design

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Air-Cooled Liquid Chiller with integrated hydraulic module

Alfa Laval Optigo CD. Commercial air coolers - Dual discharge

CHENGUAN MACHINHEY & FREEZING TECHNOLOGIES

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

MEDIUM TEMP LOW PROFILE EVAPORATORS LB ELB Series

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

LOW HEIGHT UNIT COOLER

AQVSL/AQVSH STAR 85 to 140

Hot gas bypass regulator type CPCE Liquid gas mixer type LG (accessory)

Low Profile Unit Cooler

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

COMMERCIAL WALK-IN COOLERS AND FREEZERS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

ZEFIRO. The new dual discharge air cooler AIR HEAT EXCHANGER MANUFACTURER. stefani-online.it

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

technical catalogue tetris KW Chiller and heat pumps air/water

CWP-CO / CWP-RC / CWP-HP 02 to 35

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

Industrial air coolers for cooling & freezing applications StSt/Al

CAL / CEL / CDL / CGL / CKL

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

High Profile Evaporator

TOTALINE REFRIGERATION CONDENSERS

50Hz 1500 rev/min 1 / 2 TA Luft* Prime Power. Standby Max

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Küba Green Line. Küba comfort DP. Ceiling Air Cooler.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Efficient solutions for commercial refrigeration

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

High Profile Evaporator

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

DTS 3000 Cooling Units Watt

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Price list Air coolers

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Transcription:

HFC W Glycol READY Cubic unit cooler SKB semi-industrial range Heatcraft reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual The SKB range is designed for commercial refrigeration applications or low temperature storage. Numerous electric or hot gas defrost possibilities. Wide choice of options for specific semi-industrial applications (streamer, ). The 2-speed fan (optional) enables adaptation of noise level and ventilation. Natural fluids: Glycol water (R744)* * Operating pressure 60 bar 4 30.5 kw

SUPERM AR KET SKB - Cubic semi-industrial unit cooler SUPER MARKET S MREPU TEKRA Market segments Designation SKB 19 R (1) PROCESS INDUSTRY (1) Model (2) Fin spacing: R / E 4.23 mm - L / C 6.35 mm SUPERM AR KET SUPER MARKET Hard Discount - Supermarkets - Hypermarkets Refrigerated storage and transit stocking - Dispatch centres - Food processing Description Casing FOOD SERVICE (2) S MREPU TEKRA PROCESS INDUSTRY The aesthetic, white pre-painted galvanized sheet steel casing enables SUPERM ARKET easy cleaning of the unit. The SKB-E and SKB-C models are equipped with an intermediate drain pan to help limit condensation. Ventilation The SKB unit cooler range is equipped with axial fans Ø 450 mm, 4 P 1,500 rpm, 230-400 V, 3-phase, 50 Hz, mono-block, IP 54, class F, requiring no routine maintenance and an independently connected thermal overload protection incorporated. The high-efficiency, profiled fan blades turn at a very low noise level. Fan guards are compliant with safety standards. The 2V5 option offers a low speed setting which is ideal for applications in which noise level is a key consideration. Refer to the correction chart for selection of a low-speed unit. Coil The highly efficient and compact SKB range finned coils are designed with corrugated surface aluminium fins (fin spacing 4.23 or 6.35 mm) and internally grooved copper tubes. The coils are supplied via a factory pre-fitted diaphragm distributor. Defrost The shielded (electric) heaters are inserted in the sleeved tubes in the finned coil. One of the heaters is fastened under the intermediate drain pan. This facility enables homogenous heat distribution for fast and efficient defrosting. The heaters are factory wired to a terminal block and connected for 400V/3. 230 V 3-phase or 230 V 1-phase connection possible. The condensate is recovered in an intermediate drain pan and then drained via a large drain fitting (Ø 1 G). Certifications 52 S MREPU TEKRA Advantages Installation Large space available for easy installation of the expansion valve. Possibility of providing factory pre-wired motors (CMU option) to help reduce installation time. Servicing / Maintenance Easily removable side panels and exterior hinged drain pan swivelling down offering comfortable access to all unit cooler components. The hinged drain pan enables simple removal rendering maintenance work easier (see photo).

SKB - Cubic semi-industrial unit cooler Application of options Homogenous distribution of air flow Application requiring installation of a textile duct RFA option Provides increased air throw, optimized air flow and efficient distribution of air in the cold room. VGT option Shell used to fasten the textile duct (not supplied). Adapted ventilation and noise level Kit RFA VGT VPM Factory 2V5 MM5 CMU BAE BXT WCO Options Ventilation Two-speed fan 400V/3/50Hz. Fan 230V/1/50Hz. Motor factory wired. Air stream deflector. Textile duct shell with guard for forced ventilation. Flexible defrost sleeve, shell + streamer Coil Paint coil protection. Blygold Polual XT coil protection. Glycol water, coolant (please contact us for details). R744 optimization (please contact us for details). Defrost HG1 Hot gas (coil: hot gas, drain pan: electric heating elements). HGT Hot gas (coil and drain pan). E1K E1U Light electric defrost: SKB-R and SKB-L: light electric defrost (3 coil heaters). SKB-E and SKB-C: light electric defrost (3 additional heaters in the coil). ELK ELU Complete electric defrost (SKB-R and SKB-L): 5 coil heaters + 1 drain pan heater). RVK RVU Shell defrost heaters. 2TH Defrost and safety thermostats (5709L + 5708L). THD Defrost thermostat (5709L). THS Safety thermostat (5708L). DMP EEC Fully equipped unit coolers Expansion valve fitted. Fully equipped unit cooler: - Expansion valve fitted. - Solenoid valve fitted. - Copper siphon equipped with a ball valve delivered not fitted. 2V5 option The fan motor may be wired for high or low speed: High speed during the charging phase requiring high capacity. Low speed during a long storage period or in case of presence of employees for reduced noise level. Defrost for low-temperature applications VPM option Avoid circulation of hot air during defrost cycles. Reduction of defrost cycle time for energy saving. 53

R404A ta1 SKB... R +E1K MFE... +10 +2-5 -10-25 C SKB... R 4,23 mm Y connection SKB... R 06 10 12 16 19 24 Capacity R404A (1) DT1 8K - SC 2 kw 7,62 13,17 15,77 19,87 23,51 30,48 Capacity (8) DT1 8K - SC 2 kw 7,61 12,63 14,86 18,85 23,10 28,76 Air flow m 3 /h 3650 7880 7310 11820 10960 14110 Air throw (2) m 19 21 21 23 23 25 Air throw with RFA option m 35 37 37 39 39 41 Acoustic Lp 4m (3) db(a) 50 53 53 55 55 56 Y connection (2V5 option) SKB... R 06 10 12 16 19 24 Capacity R404A (1) DT1 8K - SC 2 kw 6,40 11,19 13,25 16,89 19,75 25,30 Air flow m 3 /h 2964 6622 5928 9933 8892 11400 Air throw (2) m 15 17 17 18 18 20 Air throw with RFA option m 31 33 33 34 34 36 Acoustic Lp 4m (3) db(a) 47 50 50 52 52 53 SKB... R 06 10 12 16 19 24 Surface m 2 28,5 38,0 57,0 57,0 85,5 105,2 Circuit volume dm 3 4,9 6,5 9,8 9,8 14,7 18,1 Fan Ø 450 mm Nb 1 2 2 3 3 4 230- W max 1 x 489 2 x 489 2 x 489 3 x 489 3 x 489 4 x 489 1,500 rpm. A max (4) 1 x 1 2 x 1 2 x 1 3 x 1 3 x 1 4 x 1 W total 1050 1500 2100 2100 3000 3600 E1K (5) A total 1,56 2,28 3,19 3,19 4,56 5,47 W total 2100 3000 4200 4200 6000 7200 ELK (5) A total 3,19 4,56 6,38 6,38 9,12 10,94 Net weight kg 52 90 100 115 132 149 Connections R404A Inlet Ø (6) D 5/8 D 1"1/8 D 1"1/8 D 1"1/8 D 1"1/8 D 1"5/8 Outlet Ø ODF (7) 7/8 1"3/8 1"3/8 1"5/8 1"5/8 1"5/8 (1) See page 12. (2) Residual air speed: 0.25 m/s. (3) Average sound pressure level in db(a) measured at 4 m, at fan height, in direct line of sight on a reflective surface, given for information only.. (4) Setting of overload protection levels. For air temperatures ti other than +20, multiply the currents in relation to 293/(273 + ti ) in order to obtain an approximate current value after the chamber temperature is attained. (5) option. (6) Distributor: Male to be brazed. (7) ODF: Female to receive a tube of the same diameter. (8) Operating pressure 60 bar - Tube diameter to define the order. 652 1302 25 x 15 494 343 309 343 650 309 641 641 283 1000 1061 1000 1711 45 G 1" 600 mini 464 102 54 1952 1201 1201 2V5 MM5 CMU RFA VGT VPM BAE BXT WCO HG1 HGT E1K E1U ELK ELU RVK RVU 2TH THD THS DMP EEC O O O A O O O O A A O - O O O O O O O O O O O

R404A W ta1 SKB... L +E1K MFE... +10 +2-5 -10-25 C SKB... L 6,35 mm Y connection SKB... L 06 09 11 14 18 22 Capacity R404A (1) DT1 8K - SC 2 kw 6,56 10,42 13,43 15,54 20,14 25,92 Capacity (8) DT1 8K - SC 2 kw 6,96 10,65 13,66 16,54 21,05 26,44 Capacity W (9) DT1 8K kw 5,87-13,04-17,07 26,21 Air flow m 3 /h 3860 8210 7720 12310 11580 15000 Air throw (2) m 19 21 21 23 23 25 Air throw with RFA option m 35 37 37 39 39 41 Acoustic Lp 4m (3) db(a) 50 53 53 55 55 56 Y connection (2V5 option) SKB... L 06 09 11 14 18 22 Capacity R404A (1) DT1 8K - SC 2 kw 5,44 8,86 11,15 13,21 16,72 21,77 Capacity W (9) DT1 8K kw 5,17-11,48-15,02 23,33 Air flow m 3 /h 3196 6930 6391 10395 9587 12160 Air throw (2) m 15 17 17 18 18 20 Air throw with RFA option m 31 33 33 34 34 36 Acoustic Lp 4m (3) db(a) 47 50 50 52 52 53 SKB... L 06 09 11 14 18 22 Surface m 2 19,7 26,3 39,4 39,4 59,2 72,8 Circuit volume dm 3 4,9 6,5 9,8 9,8 14,7 18,1 Fan Ø 450 mm Nb 1 2 2 3 3 4 230- W max 1 x 489 2 x 489 2 x 489 3 x 489 3 x 489 4 x 489 1,500 rpm. A max (4) 1 x 1 2 x 1 2 x 1 3 x 1 3 x 1 4 x 1 W total 1050 1500 2100 2100 3000 3600 E1K (5) A total 1,56 2,28 3,19 3,19 4,56 5,47 W total 2100 3000 4200 4200 6000 7200 ELK (5) A total 3,19 4,56 6,38 6,38 9,12 10,94 Net weight kg 51 92 100 115 132 149 Connections R404A Inlet Ø (6) D 5/8" D 7/8" D 1"1/8 D 1"1/8 D 1"1/8 D 1"5/8 Outlet Ø ODF (7) 7/8 1"1/8 1"3/8 1"3/8 1"5/8 1"5/8 (1) See page 12. (2) Residual air speed: 0.25 m/s. (3) Average sound pressure level in db(a) measured at 4 m, at fan height, in direct line of sight on a reflective surface, given for information only.. (4) Setting of overload protection levels. For air temperatures ti other than +20, multiply the currents in relation to 293/(273 + ti ) in order to obtain an approximate current value after the chamber temperature is attained. (5) option. (6) Distributor: Male to be brazed. (7) ODF: Female to receive a tube of the same diameter. (8) Operating pressure 60 bar - Tube diameter to define the order. (9) Glycol water: Fluid: Percentage of glycol 30% - Fluid inlet temperature -8 C Fluid outlet temperature -4 C Air: Inlet dry temp. +2 - Relative humidity 85% Other conditions: please contact us. 1952 343 650 650 309 1201 1201 318 600 600 600 284 643 645 1000 2361 1345,5 1465,5 1000 2811 2V5 MM5 CMU RFA VGT VPM BAE BXT WCO HG1 HGT E1K E1U ELK ELU RVK RVU 2TH THD THS DMP EEC O O O A O O O O A A O - O O O O O O O O O O O 55

R404A ta1 + ECK SKB... E +10 +2-5 -10-25 C SKB... E 4,23 mm Y connection SKB... E 06 09 11 13 16 21 Capacity R404A (1) DT1 7K - SC 3 kw 6,15 10,11 12,56 15,29 18,95 23,47 DT1 6K - SC 4 kw 4,82 7,90 9,90 11,97 14,98 18,41 Capacity (8) DT1 7K - SC 3 kw 6,17 10,51 12,92 15,18 18,87 24,43 DT1 6K - SC 4 kw 4,98 8,51 10,52 12,19 15,28 19,87 Air flow m 3 /h 3650 7880 7310 11820 10960 14110 Air throw (2) m 19 21 21 23 23 25 Air throw with RFA option m 35 37 37 39 39 41 Acoustic Lp 4m (3) db(a) 50 53 53 55 55 56 Y connection (2V5 option) SKB... E 06 09 11 13 16 21 Capacity R404A (1) DT1 7K - SC 3 kw 5,17 8,69 10,55 13,15 15,92 19,71 DT1 6K - SC 4 kw 4,13 6,96 8,50 10,52 12,86 15,80 Air flow m 3 /h 2964 6622 5928 9933 8892 11400 Air throw (2) m 15 17 17 18 18 20 Air throw with RFA option m 31 33 33 34 34 36 Acoustic Lp 4m (3) db(a) 47 50 50 52 52 53 SKB... E 06 09 11 13 16 21 Surface m 2 28,5 38,0 57,0 57,0 85,5 105,2 Circuit volume dm 3 4,9 6,5 9,8 9,8 14,7 18,1 Fan Ø 450 mm Nb 1 2 2 3 3 4 230- W max 1 x 489 2 x 489 2 x 489 3 x 489 3 x 489 4 x 489 1,500 rpm. A max (4) 1 x 1 2 x 1 2 x 1 3 x 1 3 x 1 4 x 1 Coil Nb 5 5 5 5 5 5 Drain pan Nb 1 1 1 1 1 1 W total 2100 3000 4200 4200 6000 7200 A total 3,19 4,56 6,38 6,38 9,12 10,94 W total 1050 1500 2100 2100 3000 3600 E1K (5) A total 1,56 2,28 3,19 3,19 4,56 5,47 Sleeve defrost W total 1 x 500 2 x 500 2 x 500 3 x 500 3 x 500 4 x 500 230 V/1/50 Hz RVU / RVK A total 1 x 2,2 2 x 2,2 2 x 2,2 3 x 2,2 3 x 2,2 4 x 2,2 Net weight kg 53 91 101 116 133 154 Connections R404A Inlet Ø (6) D 7/8 D 1"1/8 D 1"1/8 D 1"1/8 D 1"5/8 D 1"5/8 Outlet Ø ODF (7) 1"1/8 1"3/8 1"5/8 1"5/8 1"5/8 2"1/8 (1) See page 12. (2) Residual air speed: 0.25 m/s. (3) Average sound pressure level in db(a) measured at 4 m, at fan height, in direct line of sight on a reflective surface, given for information only.. (4) Setting of overload protection levels. For air temperatures ti other than +20, multiply the currents in relation to 293/(273 + ti ) in order to obtain an approximate current value after the chamber temperature is attained. (5) option. (6) Distributor: Male to be brazed. (7) ODF: Female to receive a tube of the same diameter. (8) Operating pressure 60 bar - Tube diameter to define the order. 652 1302 25 x 15 494 343 309 343 650 309 641 641 283 1000 1061 1000 1711 45 G 1" 600 mini 464 102 56 1952 1201 1201 2V5 MM5 CMU RFA VGT VPM BAE BXT WCO HG1 HGT E1K E1U ELK ELU RVK RVU 2TH THD THS DMP EEC O O O A O O - - - A O O O O - - O O O O O O O

R404A ta1 + ECK SKB... C +10 +2-5 -10-25 C SKB... C 6,35 mm Y connection SKB... C 05 08 10 12 15 19 Capacity R404A (1) DT1 7K - SC 3 kw 5,24 8,05 10,65 12,38 16,09 20,17 DT1 6K - SC 4 kw 4,13 6,56 8,45 9,77 12,76 15,91 Capacity (8) DT1 7K - SC 3 kw 5,68 9,06 11,72 13,46 17,28 22,33 DT1 6K - SC 4 kw 4,60 7,33 9,55 10,86 14,04 18,19 Air flow m 3 /h 3860 8210 7720 12310 11580 15000 Air throw (2) m 19 21 21 23 23 25 Air throw with RFA option m 35 37 37 39 39 41 Acoustic Lp 4m (3) db(a) 50 53 53 55 55 56 Y connection (2V5 option) SKB... C 05 08 10 12 15 19 Capacity R404A (1) DT1 7K - SC 3 kw 4,40 6,84 8,95 10,52 13,52 17,14 DT1 6K - SC 4 kw 3,50 5,70 7,17 8,49 10,83 13,82 Air flow m 3 /h 3196 6930 6391 10395 9587 12160 Air throw (2) m 15 17 17 18 18 20 Air throw with RFA option m 31 33 33 34 34 36 Acoustic Lp 4m (3) db(a) 47 50 50 52 52 53 SKB... C 05 08 10 12 15 19 Surface m 2 19,7 26,3 39,4 39,4 59,2 72,8 Circuit volume dm 3 4,9 6,5 9,8 9,8 14,7 18,1 Fan Ø 450 mm Nb 1 2 2 3 3 4 230- W max 1 x 489 2 x 489 2 x 489 3 x 489 3 x 489 4 x 489 1,500 rpm. A max (4) 1 x 1 2 x 1 2 x 1 3 x 1 3 x 1 4 x 1 Coil Nb 5 5 5 5 5 5 Drain pan Nb 1 1 1 1 1 1 W total 2100 3000 4200 4200 6000 7200 A total 3,19 4,56 6,38 6,38 9,12 10,94 W total 1050 1500 2100 2100 3000 3600 E1K (5) A total 1,56 2,28 3,19 3,19 4,56 5,47 Sleeve defrost W total 1 x 500 2 x 500 2 x 500 3 x 500 3 x 500 4 x 500 230 V/1/50 Hz RVU / RVK A total 1 x 2,2 2 x 2,2 2 x 2,2 3 x 2,2 3 x 2,2 4 x 2,2 Net weight kg 52 81 101 116 133 154 Connections R404A Inlet Ø (6) D 7/8 D 1"1/8 D 1"1/8 D 1"1/8 D 1"5/8 D 1"5/8 Outlet Ø ODF (7) 1"1/8 1"3/8 1"5/8 1"5/8 1"5/8 2"1/8 (1) See page 12. (2) Residual air speed: 0.25 m/s. (3) Average sound pressure level in db(a) measured at 4 m, at fan height, in direct line of sight on a reflective surface, given for information only.. (4) Setting of overload protection levels. For air temperatures ti other than +20, multiply the currents in relation to 293/(273 + ti ) in order to obtain an approximate current value after the chamber temperature is attained. (5) option. (6) Distributor: Male to be brazed. (7) ODF: Female to receive a tube of the same diameter. (8) Operating pressure 60 bar - Tube diameter to define the order. 1952 343 650 650 309 1201 1201 318 600 600 600 284 643 645 1000 2361 1345,5 1465,5 1000 2811 2V5 MM5 CMU RFA VGT VPM BAE BXT WCO HG1 HGT E1K E1U ELK ELU RVK RVU 2TH THD THS DMP EEC O O O A O O - - - A O O O O - - O O O O O O O 57