Air compressors with integral variable speed control

Similar documents
Purchasing policy for higher efficiency motors

Compressed Air Efficiency: A Case Study Combining Variable Speed Control with Electronic Inlet Valve Modulation

L45SR - L75SR - L120SR

Hybrid Motor Technology to Achieve Efficiency Levels Beyond NEMA Premium

Inverter control of low speed Linear Induction Motors

CHAPTER 5 ANALYSIS OF COGGING TORQUE

Cooling Enhancement of Electric Motors

Wikov Flexible-pin Gearboxes for Industrial Applications

Energy Efficient Motors

Optimizing Drive Systems for Energy Savings

Best Practice Variable Speed Pump Systems

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Improving Rotary Screw Compressor Performance using Variable Speed Drives. John Cosner, JCI/Frick

Power Quality and Energy Management

Rotary vane air compressors for industry. Industry s advantage. with Hydrovane.

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

9 th Diesel Engine Emission Reduction Conference Newport, Rhode Island, August 2003

ECE1750, Spring Motor Drives and Other

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

Industry s advantage. with Hydrovane. aircarecompressors.co.uk. Rotary vane air compressors for industry

Nirvana hp Variable Speed Drive Rotary Screw Compressors. The Next Generation of Compressed Air

Press information. Using energy-efficient electric Motors. Meeting the International Energy Directives. October 2013

Innovative Power Supply System for Regenerative Trains

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

Working Principle of Power Saver as per Manufacture:

CHAPTER 3 EFFICIENCY IMPROVEMENT IN CAGE INDUCTION MOTORS BY USING DCR TECHNOLOGY

ACTIVE NOISE CONTROL EXPERIMENTS IN A FORK-LIFT TRUCK CABIN

AC Motors vs DC Motors. DC Motors. DC Motor Classification ... Prof. Dr. M. Zahurul Haq

Examples of Electric Drive Solutions and Applied Technologies

HYDRAULIC DIRECT DRIVES: Heavy Lift Power

NOBEL FIXED SPEED from 5.5 to 37 kw NOBEL DV VARIABLE SPEED from 7.5 to 37 kw

ingersoll rand air compressors nirvana R kw

Cigre SC B4 Activities Towards HVDC Grids. HVDC Grid Workshop Belgium

Project Summary Fuzzy Logic Control of Electric Motors and Motor Drives: Feasibility Study

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

Intelligent Balancing Solutions

Motor Systems Tool (MST)

Nirvana Variable Speed Drive Rotary Screw Compressors kw

1/7. The series hybrid permits the internal combustion engine to operate at optimal speed for any given power requirement.

Principles of iers (intelligent

Phoenix Multi Inverter/Chargers

Real-time Simulation of Electric Motors

Welcome to basics of drives training module, looking at process control and various control methods. To view the presenter notes as text, please

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

MOTOR SAMPLE PROBLEM #1 Low-Slip Drive Belts

DIRECT DRIVE BELT DRIVE

Form SPC (JUL 2012)

Using the IMV s standard ECO system to improve shock capability. Optimising Vibration Test Systems for Battery Testing using ECO Technology

SVE135 Sealed High-Voltage Contactor Having High Overcurrent Withstand Capability

QGD & QGDV Series. QGD & QGDV Series. Rotary Screw Air Compressors HP

New Capacity Modulation Algorithm for Linear Compressor

Copyright Notice. Small Motor, Gearmotor and Control Handbook Copyright Bodine Electric Company. All rights reserved.

Introduction to Variable Speed Drives. Pekik Argo Dahono Electrical Energy Conversion Research Laboratory. Institute of Technology Bandung

The cement and minerals industry

Energy savings with motors and drives

CHAPTER 1 INTRODUCTION

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

A Comparative Performance Analysis DCR and DAR Squirrel Cage 3-Phase Induction Motor

OIL-INJECTED MEDICAL AIR COMPRESSORS GA 5-11 MED / GA MED / GA 7-37 VSD+ MED

Choose quality. FIMA 1

Development of Two-stage Electric Turbocharging system for Automobiles

DEEP SEA ELECTRONICS PLC

VARIABLE SPEED DRIVES AND MOTORS

Atlas Copco Oil-injected Rotary Screw Compressors. G kw / hp

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

Nirvana Variable-Speed Drive, Contact-Cooled Rotary Screw Air Compressors

BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS

Chapter 3.2: Electric Motors

LESSON Transmission of Power Introduction

Section 5: Food waste collection vehicles

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

EDISON DV VARIABLE SPEED DIRECT DRIVEN SCREW COMPRESSORS NEWTON DIRECT DRIVEN SCREW COMPRESSORS. from 45 up to 315 kw from 7.

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

How to: Test & Evaluate Motors in Your Application

Building a Fuel Efficient Electrical Generator Using Continuously Varying Transmission

ECO (solar) RANGE OF WASTE COMPACTORS

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Hybrid Hydraulic Excavator HB335-3/HB365-3

EWAD-CZ EWAD-CZ. Inverter driven air-cooled chiller. ESEER up to 5.4. Inverter driven single screw compressor. Multiple efficiency and sound versions

bott vario Professional vehicle equipment for your Mercedes-Benz Estate cars Vito Sprinter

INDIA S FIRST 4 Star Rated Technology Inverter

Differential Expansion Measurements on Large Steam Turbines

PowerFlex 6000 Medium Voltage AC Drives

AGN Unbalanced Loads

A Grinding Solution. By John Donkers

Contact-Cooled Rotary Screw Air Compressors. Nirvana kw ( hp)

EE069: Electrical Engineering for Non-Electrical Engineers

Table of Contents. Foreword...xiii. Chapter One Introduction, Objectives of the Guide...1

Rotor Position Detection of CPPM Belt Starter Generator with Trapezoidal Back EMF using Six Hall Sensors

30 top tips to tackle HVAC challenges No.02 - Electronically commutated motors

690-V Inverters Equipped with SiC Hybrid Module FRENIC-VG Stack Series

Central Battery Systems

TTM-04: The relationship of system efficiency and speed control using VSDs vs. EC motors

Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000 mbar, vacuum to -500 mbar

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

You have probably noticed that there are several camps

Guide to the Application of Soft Starters

unrivalled benefits In the 20-40MW range take a closer look at the EPICYCLIC ADVANTAGE

Transcription:

GENERAL INFORMATION LEAFLET 45 Air compressors with integral variable speed control Air compressors with integral variable speed control are now available Electricity consumption (kw) 100 90 80 70 60 50 40 30 20 10 Energy savings Variable speed control Standard compressor Variable speed control offers large energy savings at part-load Energy savings of 9% found in recent study 0 0 100 200 300 400 500 Delivered air output (cfm) GENERAL INFORMATION LEAFLET 45 BEST PRACTICE PROGRAMME

INTRODUCTION INTRODUCTION Many air compressors spend a large proportion of their operating time at part-load. This is an inefficient use of energy when using conventional controls. However, a new generation of air compressors with variable speed controls has become available that provide an energy efficient solution to part-load operation. These compressors have a variable speed drive (VSD) built into the air compressor as an integral part of the machine. This Leaflet gives an introduction to variable speed control of air compressors, and details the results of a recent study to investigate the energy saving benefits of using an air compressor with integral variable speed control. VARIABLE SPEED CONTROL OF AIR COMPRESSORS - THE BENEFITS Variable speed control is unique because the air volume output is varied by varying the speed of the motor driving the air compressor. The motor is controlled by an electronic system referred to as an inverter, frequency controller or variable speed drive. This is unlike conventional control techniques that work by throttling the air flow into the compressor. Thus, variable speed control is inherently more efficient. Several other factors also contribute to the efficiency of variable speed controlled air compressors when operating at part-load: As the speed of the motor is variable there is no need for a gearbox or belt drive (see Fig 1) and its associated mechanical energy losses. There is tighter pressure control, allowing the mean generation pressure to be lower. In a single compressor installation, or where a variable speed machine is continuously running as a top-up machine, delivery pressure can be kept within a band of 0.2 bar. This saves 2% of power consumption compared to a typical conventional on/off machine, where the pressure band is 0.5 bar. Lower mean pressure reduces leakage and lowers air consumption by air-powered equipment typically resulting in a 2% reduction in air consumption at a mean pressure of 7.0 bar(g). Variable speed is ideal for controlling single compressors with variable loads, and compressors used to provide top-up capacity. They should not be used for supplying base load capacity as they are less efficient than comparable machines with standard controls when at full-load. This arises as some of the power is dissipated from the variable speed control electronics. Fig 1 Drive systems of conventional and variable speed screw compressors

OTHER BENEFITS OF VARIABLE SPEED CONTROL OTHER BENEFITS OF VARIABLE SPEED CONTROL Tighter pressure control not only saves energy but can also improve product quality and reduce waste. Variable speed control machines benefit from reduced starting and stopping stress due to the softstart facility within the inverter allowing almost unlimited motor starts per hour. This compares to conventional machines which are limited to typically four starts per hour to prevent damage to the motor. In some circumstances, this can allow the compressor to be completely switched off more frequently, saving energy through a reduction in idling (no-load) time. However, if the variable speed machine is working under optimum control as a top-up machine, this should not be necessary. VARIABLE SPEED CONTROLS Variable speed control of induction motors of the sizes found in screw compressors is performed by an inverter. Inverters work by rectifying the incoming AC mains to a steady DC voltage and then digitally chopping it at high frequency to produce a variable frequency, variable voltage output waveform. This variable frequency waveform allows the speed of the motor to be varied efficiently to match the air demand, and the microprocessor controls allow fast and accurate pressure control. Special switched reluctance drives are used with switched reluctance motors, but while the technology is different, both approaches use variable speed control and share the same core benefits. Fig 2 Example of application of variable speed compressor providing top-up demand above a base demand provided by a main compressor (no switching control strategy required) Fig 3 Example of application of variable speed compressor providing top-up capacity throughout the full range of demand (switching control strategy required)

SINGLE AND MULTIPLE COMPRESSORS SINGLE COMPRESSOR INSTALLATIONS The simplest use for a variable speed compressor is in a single or stand-alone compressor installation. Good energy savings can be made when the demand is below maximum output for long periods. MULTIPLE COMPRESSOR CONTROL In multiple compressors, the set-up of the control sequencing is critical for optimising energy efficiency. The most efficient set-up is to bring conventional machines on- and off-load to meet the bulk of the demand, with a variable speed machine running continuously as a top-up (Fig 4). It is essential that the control requirements for the variable speed compressor are fully discussed at the time of purchase and that the best set-up for an installation is established prior to specifying the compressor. Unless care is taken over the air compressor installation, the maximum energy savings may not be achieved. If this arrangement is not possible, or undesirable, then the installation can be set up such that the variable speed machine is set in the sequence so as to be the one most often working at part-load. However, the energy savings will not be as great as with a machine which is acting as a true top-up, as both its running hours are likely to be less and it could spend excessive periods running inefficiently at full-load. Fig 4 Capacity control with a VSD in a multi-compressor installation

A GUIDE FOR PARTICIPANTS INTEGRAL VARIABLE SPEED CONTROL HEADING TESTS AT NORWEGIAN TALC LTD TESTS AT NORWEGIAN TALC LTD Capacity tests to BS1571 were undertaken on an 18-month old Atlas Copco GA90-VSD screw compressor at Norwegian Talc Ltd, Hartlepool. The results correlated the delivered air output and compressor electrical consumption. The graph below shows the Atlas Copco compressor s performance compared to the average performance taken from many tests undertaken on similarly sized fixed-speed machines with standard on-line/off-line control. Basing the comparison on average performance compensates for the deterioration in the standard machines performance that inevitably takes place over time. The results show that the energy savings become greater as the delivered air falls. The GA90 variable speed drive Energy savings of 9.4kW (or 9% of full-load power) at 50% of rated delivery are possible, and greater savings are possible if running at even lighter load. However, at full-load the energy consumption will be 4% higher due to the power losses within the inverter. Therefore, the machines should not be used in installations running for long periods at full-load. Electricity consumption (kw) 100 90 80 70 60 50 40 30 20 10 Energy savings GA90-VSD Standard compressor 0 0 100 200 300 400 500 Delivered air output (cfm) Electricity consumption performance of the GA90-VSD compared with standard machines

ECONOMICS AND CONCLUSIONS ECONOMICS OF USING AN AIR COMPRESSOR WITH INTEGRAL VSD The energy savings from an air compressor with variable speed control can be sufficient to give a payback of one to two years through energy savings against the price premium of the variable speed machine, as experienced at Norwegian Talc Ltd. However, the exact savings depend on many factors. Key factors for establishing the economics of purchasing one of the machines include: operating hours; electricity prices; the price premium of the variable speed machine over alternative machines (15% for a GA90-VSD machine compared to an equivalent 90kW rotary screw machine); the proportion of time at part-load; the proportion of time at full-load. CONCLUSIONS Energy savings from the use of an air compressor with integral variable speed control can be economically attractive in the many applications where a compressor is running for long periods at part-load. The key points to consider are: For best energy savings on multiple compressor installations, the variable speed compressor should be run as a top-up machine. Long running hours with a high proportion at mid- to low-load are necessary for the best payback. Purchasing a compressor with integral variable speed control is more cost-effective than attempting to retrofit an existing compressor. RETROFITTING VARIABLE SPEED CONTROL It is also possible to purchase an inverter for retrofitting to standard machines. This can be attractive in some circumstances. However, purchase of an air compressor with integral variable speed control is much more attractive than fitting retrospectively as, when retrofitting, the costs of the now superfluous gearbox and any conventional controls are wasted, and manufacturers will not guarantee adequate lubrication of conventional machines at low speeds. At Norwegian Talc, the price premium for the variable speed machine gave an effective added inverter cost of 45/kW, which is considerably cheaper than when purchasing a separate inverter. The Department of the Environment, Transport and the Regions Energy Efficiency Best Practice Programme provides impartial, authoritative information on energy efficiency techniques and technologies in industry, transport and buildings. The information is disseminated through publications, videos and software, together with seminars, workshops and other events. Publications within the Best Practice Programme are shown opposite. Further information For buildings-related topics please contact: Enquiries Bureau BRECSU Building Research Establishment Garston, Watford, WD2 7JR Tel 01923 664258 Fax 01923 664787 E-mail brecsuenq@bre.co.uk For industrial and transport topics please contact: Energy Efficiency Enquiries Bureau ETSU Harwell, Didcot, Oxfordshire, OX11 0RA Tel 01235 436747 Fax 01235 433066 E-mail etsuenq@aeat.co.uk Energy Consumption Guides: compare energy use in specific processes, operations, plant and building types. Good Practice: promotes proven energy efficient techniques through Guides and Case Studies. New Practice: monitors first commercial applications of new energy efficiency measures. Future Practice: reports on joint R & D ventures into new energy efficiency measures. General Information: describes concepts and approaches yet to be fully established as good practice. Fuel Efficiency Booklets: give detailed information on specific technologies and techniques. Energy Efficiency in Buildings: helps new energy managers understand the use and costs of heating, lighting etc. CROWN COPYRIGHT FIRST PRINTED FEBRUARY 1999