Rail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals

Similar documents
QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

QF(13) - Series Miniature Circuit Breakers

QF(19) - Series Miniature Circuit Breakers

L Frame - Series Moulded Case Circuit Breakers

Accessories. CBI Mini Rail (SAMR096) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR101) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR100)

Wiring Accessories. low voltage. Wiring Accessories

DD Frame - Series Circuit Breakers

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

MS General Information Extended Product Type: MS

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

MESG 12 / 17.5 / 24 / 36 KV

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Power consumption In operation At rest For wire sizing. Connection Motor. Auxiliary switch

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Clipsal Lifesaver Portable Power Outlet with RCBO protection 485 Series

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

up to 63 A (1 module per pole)

EMPAC Metal enclosed capacitor bank for wind applications

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Voltage limiting device HVL

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Power consumption In operation At rest For wire sizing

NXPLUS C Single busbar. Maintenance-free for lifetime

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Power consumption In operation At rest For wire sizing

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Mini contactors B6, BC6 with 3 pole

Voltage limiting device HVL

MEDIUM VOLTAGE SWITCHGEAR

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

Thermal Overload Relays

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Data Sheet Manual Motor Starter Ex9S32 Series

Data Sheet Manual Motor Starter Ex9S32 Series

Residential and light commercial. invicta. panelboards

Step 1: Collection of required data

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

SF6 Load Break Switch 2017 FIL3 - S. Indoor Medium Voltage LBS With or without fuse 12kV- 24kV FIL3 D FIL3. 24KV SF6 Load Break Switch

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Power IT Compact Secondary Substations, CSS. Low Voltage Switchboard, LVS2

Combined instrument transformers

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

University of Houston Master Construction Specifications Insert Project Name

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Low Voltage Main Distribution Board

IQL Helios Area-/Streetlight. User Manual

QUALITY ASSURANCE & DOCUMENTATION

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Gas Insulated Metal-clad Switchgear, HMGS!

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

PIX-H Metal-clad switchgear up to 17.5kV

Data sheet... W-Series WPE 4

EM DC Multi-Function DC Energy Meter

RX 3 M.C.B A up to 63 A

Moulded Case Circuit Breakers

CP Automatic capacitor bank

B Mini Contactor V Hz

01 Spectra Plus - Introduction

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

RX 3 M.C.B A up to 63 A

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

CBI Hydraulic Magnetic Circuit Breakers

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

MINIATURE CIRCUIT BREAKER

Transformer bushings, type GOH. Technical guide

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Jabulani Ngobese KA & New Technology Development Manager Elster Kent Metering (Pty) Ltd South Africa

Fuse switch disconnectors

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

vertical fuse switch disconnectors

Heat Meter Integrator

Original Manual 2CCC444010M0201 Rev. 1.0, Date of Release: 02/2016. Remote Power Panel Assembly instructions

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Transcription:

Ecolec 300 The Ecolec 300 series is a rail mounted, compact, Class 1 electricity meter, available as a single or three phase meter showing the consumption of the installation. The compact rail mounted meters comply with SANS 1799 : 2004. These meters fit on a DIN rail and the CBI Mini Rail. The DIN version is grey in colour and has a 45 mm front escutcheon. The dual (DIN and CBI Mini Rail) mount version is black in colour and has a 57 mm front escutcheon. The display is an electro-mechanical counter with a seven digit indication of energy consumed to 1 / 10 kwh. A dual colour lamp shows the rate of consumption and confirms the presence of incoming power supply and some unsafe / error conditions. They are supplied with anti-tamper terminal protection plugs. These are compact in size and can be mounted next to incoming circuit breakers. They drastically reduce enclosure costs. The meter is reverse feedable and measures consumption correctly. It has a LIN bus terminal for communicating and requesting data remotely (up to 20 addressable meters on one bus). EC320CM Dual Mount EC330CM Dual Mount EC320CD DIN Mount EC330CD DIN Mount Features SANS 1799 class-1 electricity meters Class 1: accuracy < 1% Single and three phase alternatives Fits all CBI Mini and DIN rail distribution boards 7 Digit tamper-proof counter Anti-tamper terminal protection plugs Also available in 120 V / 60 Hz LED status and kwh consumption indicator Remote monitoring: LIN bus IP-45 rating 57 mm (dual mount) and 45 mm (DIN rail) escutcheon Applications Residential Commercial Rural electrification Approvals SANS 1799 Page 1 of 6

Technical Data Product Type EC320CM, EC320CD EC330CM, EC330CD Phase 1 + N 3 + N Nominal Voltage (Un) 120 / 240 V Operational Voltage Range 60-320 V Over Voltage Withstand 480 V ( 48 hr) DC Voltage Withstand 1 kv ( 1 min) Impulse Voltage Withstand 10 kv ESD Withstand 15 kv Operational Frequency Range 50 / 60 Hz Basic Current (lb) 5 A Maximum Rated Current (lmax) 80 A Operational Current Range 0.015-125 A Overcurrent Withstand 160 A ( 48 hr) Fault Current Withstand 10 ka ( 40 ms) Voltage Circuit Burden 0.2 W Product Type EC320CM, EC320CD EC330CM, EC330CD LED Output Flash Rate 1000 impulses per kwh Accuracy Class Class 1 Protection Class Class 2 double insulated Conformity To Standards SANS / IEC 62052-11, SANS / IEC 62052-21, SANS 1799 Product Type EBM Operating Temperature Range -40 C to +75 C Mounting Options Dual mounting (DIN & Mini), DIN rail Weight 158,5 g per double pole (unpacked) Humidity 35 to 85% relative Altitude Certification tests done at altitude 2000 metres. Will operate at higher altitudes. Flammability I3 - Ignition does not persist at 850 C after glow wire is withdrawn with an oxygen index of 28 Toxicity F1 - Smoke index of 20 which determines the fume class Pollution Degree PD2 - Normally only non-conductive pollution occurs. Temporary conductivity caused by condensation is to be expected. Page 2 of 6

Ordering Information Product Description Single Phase Direct Connect Three Phase Four Wire Shell Colour Escutcheon Height Mini Rail 230 V / 50 Hz EC320CM EC330CM Black 57 mm DIN Rail 230 V / 50 Hz EC320DM EC330CD Grey 45 mm Qty per Std Pack 6 3 Shrink Wrap Carton Meter Width 26 mm 52 mm Carton 178 mm wide Meter Height 107 mm 107 mm Carton 68 mm high Meter Depth 66 mm 66 mm Carton 110 mm high Mass / Std Pack 1060 g 1150 g Wiring diagram N or m al application (industr ial exam ple) T hree Phase U ni-phase: Method 1 (r ur al exam ple) Single Phase s U ni-phase: Method 2 (r esidential exam ple) Single Phase s SF-36A 80A 5kA Earth Leakage QA17A20 QF17A20 20A 3kA Earth Leakages SF15A 80A 5kA Earth Leakages Meter Meter Meter Line Line Line N eutral Red W hite Blue (?) 80A 5kA Breaker N eutral Red x 80 Amp Breaker N eutral Red x 150 Amp Breaker Incoming supply Incoming supply Incoming supply Page 3 of 6

1 2 1 2 1 2 low voltage T hree protection fuses on the busbars F1 3 phase, 4-wir e, incom ing supply B W R N F1 F1 W ARN IN G: T he C Ts are at phase potential and must not be earthed. All metal parts must be insulated N R W B LO AD C T meter 0000012 C T C T LIN E L O A D side LED Indication LED Indication Pulses RED Pulses GREEN Solid GREEN Pulses ORANGE Solid ORANGE Solid RED No LED Reason/ Description Normal consumption pulses (1000 pulses per kilo watt hour) Low load condition (consumption is less than 30 watts) No load (meter is powered up) Abnormal load (supply voltage is between 265-460 V or 60-90 V AC) Unsafe load condition (the current being drawn is greater than 125 A or the supply voltage is greater than 460 V AC) Error condition (the meter s internal built in test has failed) No LED indication (insufficient supply voltage) Page 4 of 6

EC 300 series kwh consumption when using external CTs There is a requirement to measure loads in excess of the metre s maximum current rating of 80 A. This can be done by using external CTs. The actual kwh consumption per phase can be calculated as follows: CT Ratio x Counter Value E.g.: For a 200/5 CT ratio the factor is 40. Therefore the consumption per phase = 40 x kwh consumed. For CT Selection, please refer to the NRS057 specification parts 1, 2 and 4. NOTE: Do not earth CTs fitted above! Accuracy graph 5.0% 3.0% 1.0% -1.0% -3.0% -5.0% 0.1 1 10 100 Additional influence of current variation at Un = 230 V, f = 50 Hz, t = 25 C Currrent (A) 0.05 0.1 0.25 0.5 1 2.5 5 10 20 40 60 80 100 Resistive (1) -1.18% -1.86% -0.04% -0.31% 0.00% -0.29% 0.00% 0.17% 0.04% 0.15% 0.20% 0.07% 0.04% Ind. (0.5) 7.42% 2.45% 0.61% -0.15% -0.69% -0.14% 0.10% -0.28% 0.43% 0.02% -0.17% -0.21% 0.10% Cap. (0.8) -5.01% -2.66% -0.58% -0.11% 0.51% -0.25% 0.10% 0.20% 0.06% 0.20% 0.33% 0.43% 0.43% % Ib 1% 2% 5% 10% 20% 50% 100% 200% 400% 800% 1200% 1600% 2000% Page 5 of 6

Dimensional Drawing: Black, 57 mm Front Escutcheon Dimensional Drawing: Grey, 45 mm Front Escutcheon Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 27 Wedgewood Rd, Hallam Victoria 3803 Australia Tel: +61 3 8752 9300 Fax: +61 3 9796 5407 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au Page 6 of 6 SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com internationalsales@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com A member of the Group