ADM DIN-RAIL KWH Meter 1. Applications ADM is a kind of electronic Din rail watt-hour meter.it completely accords with relevant technical requirements of class 1 and class 2. It can accurately and directly measure active energy consumption. It also can display total energy consumption by step type impulse register or LCD display. This watt-hour meter is according to EN62053-21. ADM25SC Conform to EN62053-21 Accuracy Frequency Single phase Rated impulse voltage Power consumption Temperature range Conform to EN62053-21 Accuracy Frequency Three phase Rated impulse voltage Power consumption Temperature range class 1,2 50/60Hz 120V/230V Uimp 6KV-1.2/50S 1.5w/6VA per phase -10 -+50 class 1,2 50/60Hz 230V/400V Uimp 10KV-1.2/50S 2w/10VA per phase -10 -+50 ADM65S ADM100S ADM100SC 2. Specification TYPE ADM25S ADM25SC(LCD) ADM65S ADM100S ADM100SC (LCD) ADM100T ADM100TC (LCD) Rating 2.5(10)A 3(15)A 5(25)A 2.5(10)A 3(15)A 10(40)A 15(60)A 2.5(10)A 10(50)A 15(60)A 10(60)A 15(90)A 1.5(6)A CT 3(6)A CT 10(60)A 15(90)A 1.5(6)A CT 3(6)A CT 10(60)A 15(90)A Voltage AC120V/230V AC120V/230V AC230V AC120V/230V 230V 230V 230/400V 230/400V 230/400V Mounting:DIN rail EN 50022 Class Designation /2.0 /2.0 /2.0 Single Phase 1 Single Phase 2 Single Phase 4 Single Phase 4 Three Phaes 7 Three Phase 7 ADM100TC D-01
DD862 DD28 DD862 DT862 DT8 Kilo Watt-hour Meter 1. Applications The series single phase meter is a kind of induction meter to measure the single phase current at the rated frequency of 50Hz. It is an indoor installed meter. Ambient temperature: - 10 C to 50 C, relative humidity: below 85% (25 C). DT8 and DT862 series three-phase meter is an induction meter to measure the three-phase current at the rated frequency (50Hz). It is an indoor installed meter; Ambient temperature: -10 C to 50 C, except the first grade is under the working condition of 0 to 40 C. Relative humidity: below 85% (25 C). DD282 2. Specification Item Type Accuracy R.V. Calibration (A) Manner DD862-4 2.5(10)5(20)10(40) 15(60)20(80) 30(100) direct connction connection with singlephase watt-meter DD862-2 DD282 2 220 1.5(6) 3(6) 2(4)2.5(5)3(6)5(10) current transformer DD28 10(20)20(40)30(60) direct connection DD28 three phase four-wire watt meter DT862-4 DT862-2 DT8 2 3x380/220 40(80)5(20)10(40) 5(20)10(40)15(60) 20(80)3(100) 1.5(6) 3(6) 10.25.40.80 direct connection connection with current transformer direct connection DD862 DD862 DT862 DT862 D-02
DDS480 DDS480 Single Phase Electronic Kilowatt Hour Meter 1. Application DDS480 series electronic single phase watt hour meter is a high technology product adople avanced IC technology as well as SMT technology, both circuit design and componects selectior are up to various working environment to guaranty that power meter can operate steadily for a lor time. the finished meter don t neet to be adjusted so that the calibration cycle is long. it extremely reduce the labor force of the electricity board for calibrating power meters. the feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215-200 standard. 2. Spcification Name Type Accuracy(class) Basic current Single Phase Electronic Kilowatt Hour Meter DDS480, 2.0 1.5(6)A,2.5(10)A,5(20)A,10(40)A, 45(60)A,20(80)A,,10(60)A, 80ms 20ms DTS480 Three Phase Electronic Kilowatt Hour Meter 1. Application DTS480 series electronic three phase watt hour meter is a high technology product adopted advanced IC technology as well as SMT technology, both circuit design and components selectior are up to various working environment to guaranty that power meter can operate stecdily for a lon time, the finished meter don t need to be adjusted so that the calibration cycle is long, it extremely reduce the labor force of the electricity board for calibrationg power meters, the feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215-200 standard. 2. Name and specification Name Type Accuracy (class) Rated voltage (V) Rated current (A) Connection Three phase four 3x1.5(6), 3x3(6) CT wire adive energy electronic type watthotu meter DTS480 1 3x380/220 3x5(20), 3x10(40) 3x1.5(60), 3x5(30) 3x10(60) Direct D-03
SFC Modular Type Panel Meter MODEL SFC-45 SFC-100 NAME AC AMMETER DC AMMETER AC VOLTMETER DC VOLTMETER FREQUENCY METER POWER FACTOR METER(COS ) POWER METER(KW OR KVAR) SPECIFICATION ACCURACY FROM 10A,15A, 20A,30A TO 3000A,500A FROM 0.1A,0.5A, 1A,5A,10A,25A TO 80A,100A FROM 50µA,100µA, 1mA,5mA 1A,5A,10A,25A,30A TO 100 FROM 10A,15A, 20A,30A 2500A,3000A TO 8KA,10KA FROM 30V,50V, 100V TO 300V,500V,600V FROM 1KV,2KV, 5KV TO 380KV,450KV FROM 10V,20V, 30V TO 500V,600V,1000V FROM 1KV,2KV, 5KV TO 8KV,9KV,10KV VOLTAGE: 110V,220V,380V,440V FREQUENCY: 45-55Hz,45-65hZ,55-65Hz,47-53Hz VOLTAGE: 10V,220V,380V,440V CURRENT: 1A OR 5A SCALE: 0.5cap-1-0.5ind, 0.3cap-1-0.1ind, 0.7cap-1-0.2ind WITH EXT.C/T 1A OR 5A AC DIRECT CONNECTION DC DIRECT CONNECTION WITH EXT,SHUNT 50MV,60MV OR 75MV AC DIRECT CONNECTION WITH EXT.VOLTAGE TRANSFORMER DC DIRECT CONNECTION WITH EXT. RESISTOR FOR IPHASE OR 3PHASE FOR IPIW,3P3W,3P4W CLASS CLASS 2.5 VOLTAGE: 110V,220V,380V,440V CURRENT: 1A OR5A WITH C/T OR VOLTAGE TRANSFORMER 1. Outline Drawing 2. Size Of Din Rail Type Series Meter Model Unit D SFC-45 mm 4 SFC-100 mm 10 Number of terminal 45 100 Measurement of din rail 35 35 D-04
AM72 Panel Meter AC Ammeter Specs:0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-105A(use Ext.CT 5A) Note:for60/75/100A direct meter,the class is 2.5. Advantage:The scale can be easily changed without opening the front frame so that the class will not be influenced. DC Ammeter Specs:25uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA 300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75-105A(used with Shunt) Feature:The scale can be easily changed without opening the front frame so that the class will not be influenced. AC Voltmeter Specs:30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380KV,should be used with potential transformer secondary voltage 100V. DC Voltmeter Specs:3V 5V 7.5V 10V 15V 20V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 600V Note:Over 600V should be used with Ext.Resistor.(Rated Cuuent 5mA). MOVING COIL INSTRUMENTS FOR NONELECTRIC VALUES Model:AM-96 AM-72 These meters can measure the other non-electric values for example,temperature,speed and so on. Frequency Meter Pointer Type Class: Volt:50V 100V 220V 380V Freq:44-55Hz 45-66Hz 55-65Hz 47-53Hz 57-63Hz 44-56Hz 54-66Hz 450-550Hz 550-650Hz D-05
AM96 Panel Meter POWER FACTOR For 3 phases circuits,balanced load 45-65Hz and for 1 phase AC 50Hz. Model:AM-96 AM-72 Class:2.5 Voltage:100V 380V 440V Frequency:50Hz 60Hz Scale graduation:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind. Orders to be Noted: Type of Current:1P,3P 3W circuits,balanced load. Rated Volt:The voltage is line voltage(between two wires). Operating Current:If used with CT,the secondary current 5A or 1A is standard. POWER METER Wattmeters with built-in converter for 1 phase,3p 3W,3P 4W. Model:AM-96 AM-72 Voltage:50V 100V 220V 240V 220/380V 240/415V Current:5a These meters are used with potential secondary voltage 100V voltage transformer or secondary current 5A CT.wattmeters with built-in converter for 3P 3W,3P 4W and single phase. MODEL:AM-96 AM-80 AM-72 AM-60 AM-50 Struction:Moving Coil,Moving Iron and Rectifier. Class:2.0 2.5 Name Specifications Remarks DC Ammeter 30-1000uA 1-1000mA 1K-10KA 1-50A With EXt.Shunt DC Voltmeter 40-1000mV 1-1000V 1K-10KA 1-50A With EXt.Resistor DC Ammeter 1-1000mA 5-1000A 1-50A 1K-0KA With EXt.CT DC Voltmeter 40-1000mA 1-1000V 1K-380KV With EXt.CT Frequency Meter Voltage:50-380V Frequency:45-55Hz 45-65Hz 55-65Hz Power Factor Meter Power Meter Voltage:50-380V Frequency:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind Suitable for 1Por 3P3W Circuit Voltage:50-380V Current:0.2-5A With Current or Voltage Transformer Only AM-80 is available D-06
AM72 Digital Panel Meter 1. Application Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise A/D changeover circuit and high light LED cassette setting specification. It is very convenient for user to fix the equipment. 2. Specification Description Direct input range Input current range Operation voltage Display range Class AC & DC digital voltage meter AC & DC digital Ampere meter Frequency digital meter AC tri-phase watt meter AC single-phase watt meter AC DC0-100V AC 10-20A DC 0-10A AC 10-2KHZ (20-300V) AC 0-100V AC 0-220V AC 5A AC 10-5A AC 380V 50/60Hz AC 110V 50/60Hz AC 110V 50/60Hz 0.5 0.5 0.5 AC single-phase factor meter AC 100-300V AC 5A 0.5-0-0.5 AM72-H, AM96-H AM72-Hz, AM96-Hz AM72-V, AM96-V AM72-I3, AM96-I3 AM72-V3, AM96-V3 AM72-A, AM96-A AM72-W, AM96-W AM48-I AM48-HZ AM48-H AM48-V AM-150V AM-150A AM-150Hz D-07