Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

Similar documents
Data Sheet 3.11 Issue F

Data Sheet 3.03 Issue D

Data Sheet 3.01 Issue C

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

Flexible Sprinkler Connections

I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

PROFLEX FLEXIBLE SPRINKLER HOSES (PAGE 1/5)

KOFULSO /Easyflex flexibles sprinklers drop distributed by

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

Instructions for Installation, Operation, Care and Maintenance

TECHNICAL DATA SPRINKLER ESCUTCHEONS

Flexible Sprinkler Connector Braided & Unbraided

I-VICFLEX.AB1/AB2/AB10

TECHNICAL DATA OBSOLETE

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Easy Riser swing check valve Models E-1 & F-1

Instructions for Installation, Operation, Care and Maintenance

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

Instructions for Installation, Operation Care and Maintenance

TECHNICAL DATA CONCENTRATE CONTROL VALVE APPLICATIONS, PRIMING CONNECTIONS, AND TRIMS 1. GENERAL DESCRIPTION 2. LISTINGS AND APPROVALS.

TECHNICAL DATA. Trimpac 244a. April 15, 2011

TECHNICAL DATA OBSOLETE

Contents Project: Model: Chk d: Date:

TECHNICAL DATA. Trimpac 249a. September 16, 2013

SUMMARY STAINLESS STEEL FITTINGS FITTINGS P PUSH-IN FITTINGS, STAINLESS STEEL D3.2 P STANDARD FITTINGS SERIES XA D3.8 P QUICK FITTINGS SERIES XC D3.

TECHNICAL DATA. Notes: For use with Trim Charts on Pages 2-4

Installation. Installation. 12. System Diagram... 10

TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

MARCH Polyethylene Piping Systems.

Hole-cutting. cutting a hole. After the hole has been cut all rough edges must be removed and the area within 5/8 (16mm) of the hole

One Million Raindrops by Senju Sprinkler. Product Brochure

INSTALLATION INSTRUCTIONS

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

Grooved Piping System for Fire Protection Services

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

Victaulic Fittings, Couplings, Valves & Sprinkler Heads for the Fire Sprinkler Market Keeping the art of distribution simple

XP-300 Series Sprinklers Installation & Service Instructions

NOTE ITEM PART NUMBER KIT CONTENTS QTY

Pro-Swirl Manifold Air Heater

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Section 2. Shurjoint Grooved Fittings Flow Data / Friction Resistance Ductile Iron Grooved Fittings. Wrought Grooved Fittings

Carbon or stainless Steel

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY


B U I L D I N G C O N N E C T I O N S T H AT L A S T

Installation S Freestanding Drench Shower

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

Male stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...

TECHNICAL DATA. Q= C v P S

Instructions for Installation, Operation, Care and Maintenance

Rapid push-in fittings for plastic tubes Series 1000

PRESS-FIT SYSTEM FOR SPRINKLER CONNECT WITH CONFIDENCE

FIRE PROTECTION PRODUCTS

Grinnell Grooved Fire Protection Products Grooved Fittings

Auxiliary Transmission Filter Kit

Model T Professional Series 1/2HP 2 YEAR WARRANTY SHALLOW WELL JET PUMP

Information Sheet Polyethylene Tank Assemblies

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

HPS SERIES. Steam Joints DEUBLIN COMPANY Norman Drive, West Waukegan, IL USA Phone: 847/ Fax: 847/ Rev.

B42 Series Regulator Residential Regulator

27" Natural Gas Conversion Manual

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

Listings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5

Installation Manual. For ISC, ISL, ISC03 And ISL03 Engines

INSTALLATION INSTRUCTIONS PARTS LIST INSTALLATION INSTRUCTIONS AIR CONTROL KIT (800A0168 OR 800A0169)

Installation. E19-310AC Combination Drench Shower and Eye/Face Wash. Table of Contents

Inverted High Pressure Fluid Filters

Inverted Dual High-Pressure Fluid Filter Assemblies

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

Professional Series 1/2HP 2 YEAR WARRANTY CONVERTIBLE JET PUMP REPAIR PARTS

BMK-30. Heavy-Duty By-Pass Filtration System Installation and Servicing Instructions

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

Operating Procedures for 2 SCH 160 through 10 SCH 120 GripTight Long Radius Elbow Test Plug

Plumbing. Controls, Drains, Piping, Flanges, Couplings, Caps and Plugs

DELUGE VALVE DATA SHEET

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

INSTALLATION INSTRUCTIONS

BMK-18 U.S. Patent #5,298,158

Fittings threads: metric (M5), BSP (G1/8, G1/4, G3/8, G1/2, G3/4, G1), BSPT (R1/8, R1/4, R3/8, R1/2, R3/4, R1)

TECHNICAL DATA 1-1/2 (dn40)

TECHNICAL DATA CAUTION

IRRIGATION FITTINGS PRODUCTS PRICE LIST SWING JOINT & HEAVY TURF INCLUDES: PVC SWING JOINTS AND IRRIGATION ACCESSORIES PRICE GROUP DISCOUNT MULTIPLIER

Installation manual. SCR system. Marine engines DI13, DI16. 02:07 Issue 1.0 en-gb. Scania CV AB 2016, Sweden

Installation S19-310LL. Combination Drench Shower and Eyewash

Electrically heated SCR hose lines Installation guide Document number

model E Spray nozzles vk810 - vk817

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

2016 PRODUCT CATALOGUE

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

ONE TOUCH FITTINGS Series WP2

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Taps, Valves & Components. Section 1

GROOVED COUPLINGS - STANDARD FLEXIBLE Model 101

Transcription:

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual January 2016

Page 2 of 10 TABLE OF CONTENTS Section Description Page 1 Benefits 3 2 Installation Instructions 3 3 Technical Data 7 4 Part Numbers 8 5 Components 9

Page 3 of 10 Figure 1: Model VKFD28B Braided Flexible Drop (Shown with a Viking Concealed Sprinkler) Figure 2: Model VKFDU28 Unbraided Flexible Drop (Shown with a Viking Concealed Sprinkler) 1. benefits Viking Flexible Sprinkler Drops provide many benefits for installation or retrofit compared to fixed including: More efficient use of manpower Improved performance and installation quality Precise location of sprinklers Flexible installation for Seismic applications Corrosion-resistant materials Fewer tools required for installation 100% Factory Tested Special centre bracket design that allows all sprinkler types, including concealed, to be installed as the last step, increasing flexibility Meets NFPA, EN, CNBOP, R1, and LPC guidelines Approved for use with suspended ceilings with intermediate- and heavy-duty systems designed per ASTM C635 and C636 Viking Flexible Sprinkler Drops are a complete unit assembly. Included parts: Braided or non-braided exterior, corrugated, stainless steel flexible hose Ø28 mm Inlet nipple 1 (DN25) or 1-1/4 (DN32) NPT or BSPT Straight outlet reducer 1/2 (15 mm) or 3/4 (20 mm) for attachment of sprinkler (90 angle outlet reducer available for order separately) Support bar Brackets Viking Flexible Sprinkler Drops are available in various lengths to minimize the number of installed bends and meet the minimum material requirements of the installation. 2. INSTALLATION INSTRUCTIONS Step 1: Ensure proper sprinkler position where the sprinkler is to be located and cut the proper clearance hole in the ceiling tile as described in the sprinkler technical data page. The sprinkler should be installed near the centre of the ceiling tile and between the main support rails of the suspended ceiling support system. The standard centerline of support beams is 600 mm, of which the support bar (Item 2 in Figure 1 furnished as standard) is 650 mm long. Form No. F_040115 16.04.21 Rev 16.1

Page 4 of 10 NOTE: A 1200 mm spacing is possible with a separately available support bar 1250 mm long (Part No. 14398). Step 2: See Figure 3 Attach the rail clips (1) to the ceiling grid using a screwdriver or by hand. REF# PART # DESCRIPTIONS QTY. 1 19253 RAIL CLIP 2 2** 14397 RECTANGULAR BAR, 650 mm 1 3 14400 WING BOLT, M6 X 15 mm 3 4 18287 WING BOLT, M6 X 25 mm 2 5 19695 OUTLET REDUCER SUPPORT BRACKET 1 NOTE: When installing, attach the brackets to the ceiling s main tee bar supports. Do not attach to cross support rail members. ** For long bar 1250 mm, order Part No. 14398 kit separately (10 bars per kit) Figure 3: VKFD Rail Clip Installation Step 3: See Figure 4 A. Apply a non-hardening thread sealant or sealant tape to the male threads of the nipple ONLY on the end that installs into the tee or elbow. DO NOT apply sealant to the hose connection thread. B. Install the inlet nipple into the branch line outlet tee or elbow. Make sure the tapered pipe thread is installed in the tee and the special shoulder thread is pointing towards the sprinkler location. Tighten the nipple into the tee with a pipe wrench for a leak-tight connection. C. Hand-tighten the hose on the fitting, then use a wrench to tighten and additional 1/4 turn (~8.5 N.m). The Viking flexible sprinkler hose includes a slip nut on both ends for attachment to the branch line fitting and the sprinkler outlet fitting that is secured in the ceiling support system as shown in Figure 4. NOTE: If possible, attach the hose after it has been formed into the proper installation shape to eliminate rotation of the hose when threading onto fittings. Figure 4: VKFD Nipple and Hose Installation

Page 5 of 10 Step 4: See Figure 5 Ensure that the maximum number of specified bends, with the minimum bend radius, are adhered to. A radius tool is available, which provides a minimum bend radius of 3 (75 mm) (part number 14402). NOTE: To minimize friction loss, a large bend radius is recommended; however it must be a smooth, constant radius. Note that the radius of the flex hose must NOT fall in the non-corrugated ends. Avoid long lengths of hose for the distance, as this would require more bends to install, possibly including low spots or kinks. Excessive numbers of bends might not properly drain and can cause severe pressure loss. Figure 5: VKFD Examples of Proper Installation NOTES: To route flexible hose around obstructions, select the proper length based on the type of obstruction to be avoided. Minimize the number of bends to ensure proper operation. Observe the minimum bend radii and the discharge location from the branch piping. See Figure 5 for illustration of recommended practice. Figures 6 and 7 illustrate different use of fittings. Figure 6 Form No. F_040115 16.04.21 Rev 16.1 Figure 7

Page 6 of 10 Step 5: Install the desired sprinkler head in the outlet reducer. Due to the special design of the Viking centre bracket, the sprinkler can be installed into the outlet nipple before it is attached to the sprinkler hose. Apply non-hardening thread sealant or sealant tape to the male threads of the sprinkler head and tighten the sprinkler in the outlet reducer using the appropriate sprinkler head wrench. Assemble one end of the flexible hose to the reducer shoulder thread and hand tighten, then tighten 1/4 turn to approximately 8.5 N.m of torque so as to not cut or crush the O-ring provided in the hose assembly. Step 6: Properly form the required bend radii around bend tool or cylindrical formed object or pipe, to provide constant and smooth radius, and align the hose for connection to the special inlet nipple installed in the sprinkler system branch line tee. First, attach the hose slip nut onto the shoulder nipple fitting hand tight, plus 1/4 turn to tighten to approximately 8.5 N.m of torque. DO NOT use sealant compound on the shoulder nipple threads. Next, properly form the flexible hose, forming the proper number of bends and minimum bend radius to align with the sprinkler outlet reducer. Attach the slip nut of the flexible hose to the sprinkler outlet reducer hand tight, same as above. DO NOT apply sealant to this thread, as the O-ring makes the seal. Step 7: After checking alignment of the sprinkler with the clearance hole and flush positioning with the finished ceiling surface, verify that all wing screws and the hose slip nuts are secure. The sprinkler outlet reducer and sprinkler can be placed in the centre bracket and the wing screw tightened by hand and/or power driver to a recommended torque of 2 N.m. Test the system for leaks per the hydrostatic test procedure of the applicable edition of NFPA 13, EN12845, or other local installation standard. TABLE 1: FRICTION LOSS DATA WITH 75mm BEND RADIUS (½ or ¾ OUTLET) Hose length (mm) Outlet Equivalent Length** of 1 Schedule 40 pipe (m) Maximum number of 90 bends*** 700 ½ or ¾ 3.4 3 1000 ½ or ¾ 5.8 3 1200 ½ or ¾ 7.8 3 1500* ½ or ¾ 8.8 3 1800* ½ or ¾ 9.6 3 *These lengths are LPCB approved but not authorised by LPC Technical Bulletin TB227. **Equivalent length is for a straight hose with one 90 bend. ***According to LPCB approval. A 90 outlet elbow (if used) is considered one 90 bend.

Page 7 of 10 3. Technical data Specifications: Available since 2008. Hose tube diameter: 28 mm outside diameter Lengths available 700mm, 1000 mm, 1200 mm, 1500 mm and 1800 mm Inlet 1 /DN25 or 1-1/4 /DN32 BSPT male pipe Available braided or unbraided Outlet reducer straight with 1/2 /15mm or 3/4 /20mm NPT (suitable for both NPT and BSPT) Outlet reducer 90 angle with 1/2 /15mm or 3/4 /20mm NPT (suitable for both NPT and BSPT) Corrugated tube is polished and boron treated and annealed after forming to insure relief of all material stresses and removal of all scale Maximum Working Pressure (unbraided) = 13.8 bar Maximum Working Pressure (braided) = 17.2 bar! WARNING Refer to the sprinkler technical data page, as the temperature rating and maximum pressure rating of the sprinkler may be different than the Flexible Sprinkler Drop. Test Pressure (unbraided) = 20.7 bar Test Pressure (braided) = 25.8 bar Accepted for wet and dry systems as noted in NFPA 13 LPCB Approved for wet systems in accordance with LPC Technical Bulletin TB227 Maximum ambient temperature: 149 C EPDM seal Minimum bend radius: 75 mm for LPCB Approval Material Standards: Flexible Tube: Outlet Reducer (Straight or Angled): Inlet Nipple: Seal: Slip Nut: Support Brackets (all): Support Bar: AISI 304 Stainless Steel SPPS Steel with yellow zinc plating SPPS Steel with yellow zinc plating EPDM SS41 Steel with zinc plating SS41 Steel with zinc plating SS41 Steel with zinc plating TABLE 2: BOX CONTENTS Each box of VKFD28 Flexible Hoses contains ten (10) complete assemblies consisting of the parts in this table. Description Quantity Flexible hose 10 Inlet nipple 10 Outlet reducer (straight) 10 Support bar 10 Support clip 20 Centre bracket 10 Wing bolt, M6 x 15mm 30 Wing bolt, M6 x 20mm 20

Page 8 of 10 4. part numbers Part Number (Unbraided) TABLE 3: PART NUMBERS Part Number (Braided) Length (mm) Inlet Outlet VKFD28U-111 VKFD28B-111 700 25mm BSP 15mm/1/2 VKFD28U-211 VKFD28B-211 1000 25mm BSP 15mm/1/2 VKFD28U-311 VKFD28B-311 1200 25mm BSP 15mm/1/2 VKFD28U-411 VKFD28B-411 1500 25mm BSP 15mm/1/2 VKFD28U-511 VKFD28B-511 1800 25mm BSP 15mm/1/2 VKFD28U-112 VKFD28B-112 700 25mm BSP 20mm/3/4 VKFD28U-212 VKFD28B-212 1000 25mm BSP 20mm/3/4 VKFD28U-312 VKFD28B-312 1200 25mm BSP 20mm/3/4 VKFD28U-412 VKFD28B-412 1500 25mm BSP 20mm/3/4 VKFD28U-512 VKFD28B-512 1800 25mm BSP 20mm/3/4 VKFD28U-121 VKFD28B-121 700 32mm BSP 15mm/1/2 VKFD28U-221 VKFD28B-221 1000 32mm BSP 15mm/1/2 VKFD28U-321 VKFD28B-321 1200 32mm BSP 15mm/1/2 VKFD28U-421 VKFD28B-421 1500 32mm BSP 15mm/1/2 VKFD28U-521 VKFD28B-521 1800 32mm BSP 15mm/1/2 VKFD28U-122 VKFD28B-122 700 32mm BSP 20mm/3/4 VKFD28U-222 VKFD28B-222 1000 32mm BSP 20mm/3/4 VKFD28U-322 VKFD28B-322 1200 32mm BSP 20mm/3/4 VKFD28U-422 VKFD28B-422 1500 32mm BSP 20mm/3/4 VKFD28U-522 VKFD28B-522 1800 32mm BSP 20mm/3/4 TABLE 4: PARTS AVAILABLE TO ORDER SEPARATELY Part Number Description 14402 75mm (3 ) bend radius gauge tool 15913 75mm (3 ) bend radius clip 14379 Inlet Nipple, DN25/1" BSPT 14381 Inlet Nipple, DN32/1-1/4" BSPT 18727 ½ straight outlet reducer 18728 ¾ straight outlet reducer 18725 ½ 90 outlet fitting 18726 ¾ 90 outlet fitting 49000703 Support clip 19695 Centre bracket 14397 650mm support bar 14398 1250mm support bar (for larger tile spacing) 41200013 Wing bolt, M6 x 15mm 41200012 Wing bolt, M6 x 25mm 49000089 Plasterboard/drywall clip with screw (2pcs)

Page 9 of 10 5. components TABLE 5: COMPONENTS Image Description Part Number Support clip Wing bolt, M6 x 15mm Wing bolt, M6 x 20mm 49000703 41200013 41200012 Centre bracket Wing bolt, M6 x 15mm 19695 41200013 Support bar 650mm (supplied as standard) Support bar 650mm (available to order separately) Inlet Nipple, DN25/1 BSPT Inlet Nipple, DN32/1-1/4 BSPT 14397 14398 14379 14381 ½ straight outlet reducer ¾ straight outlet reducer 18727 18728

Page 10 of 10 ½ 90 outlet reducer ¾ 90 outlet reducer 18725 18726 Wing bolt, M6 x 15mm Wing bolt, M6 x 20mm 41200013 41200012 75mm (3 ) bend radius gauge tool 14402