Off-line filter / cooler unit BKF

Similar documents
Off-Line Filter BNF. FluidControl

Off-line filter units BNF. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2019

Oil/air cooler BLK. Fluidcontrol

Off-line filter / cooler unit FGSL

Circulation pumps BFP-ATEX-T3/T4

Oil/air cooler BLK. Fluidcontrol

Oil/air cooler BLK ATEX-3GD

Temperature sensors. Fluidcontrol

FA 016 FAPC 016. Oil Service Units. Description. Page 53

Feed Pumps VP / VPB / VPBM

E 068 E 088 In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min

GMP-Type. Key Features: Integrated Motor-Pump Units

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

Return-Suction Filters E 068 E 088. In-line mounting Connection up to G¾ Nominal flow rate up to 100 l/min e

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

Oil Filter Module Pi 8300

Cooling Systems CC Series TT rail 20/30lpm

Cleanline portable. Oil Service Units FA 016 / FAPC 016

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

Oil / air cooler Series BLK-DC

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Oil Filter Module Pi 8300

Type KKP. Combination pumps

Off-line Oil Filter Module Pi 8400

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

High-pressure pumps Series HP45

OFFLINE SERIES GLOBAL STANDARD COOLER

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

Installation and commissioning of Settima screw pumps. Type GR** SMT** 3-screw screw pumps. a. Medium:

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Return line and Suction Boost Filter RKM

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

High Pressure Filter Pi 4230

GLOBAL STANDARD COOLER

Duplex Filter Pi 3700

Tank top return-line filter Pi 5000

Medium Pressure Filter Pi 3000

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

High Pressure Filter Pi 4000

GLOBAL STANDARD COOLER

Oil/Air Cooler Units

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Suction Filter Pi 200

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

Screwpump. Series D GB. General Description. Model Code D 4

Duplex Filter Pi 2100

- DIMENSIONS AND WEIGHT 400 PUMP DUMPER 1X SERIES 400 PUMP DUMPER 2X SERIES 401 PUMP DUMPER 3X, 4X, 5X, 6X, 7X, 8X SERIES 402 PACKING 403

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Valve Technology and Special Solutions for Transmissions on Mobile Machines

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Low Pressure Filter Pi 2000/Pi 2200

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Electric Immersion Pumps PXA and PXK, sealless

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

We produce fluid power solutions. Fluid Management. Off-line Filters Off-line Filter Units Oil Service Units Dewatering Systems Filter Elements

Hydraulic drive power unit Low-noise compact unit Whispering power unit

Vane pumps, direct controlled Type PV7...A

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Contents. Identification

Lowara. Centrifugal Electric Pumps Manufactured in AISI 316 Stainless Steel in Compliance with EN 733. SH Series. 60 Hz

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

GLOBAL STANDARD COOLER

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

High Pressure Filter Pi 420

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Screw Pump Twin Aggregates Series SPZ/M MagDrive

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

SPIN-ON FILTER - LOW PRESSURE LINE

Pilot Operated Pressure Relief Valve Series R5V (Denison)

High Pressure Filter Pi 4230

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

High Pressure Filter Pi 410

Low Pressure Filter Pi 2000

barmesapumps.com VERTICAL MULTI-STAGE PUMP PERFORMANCE CURVE NOMENCLATURE B M V

UM 045 UMPC 045 Oil service - simple, quick and compact with integrated particle monitor

DUMPER. Data Book 50 Hz

Block mounting filter, for lateral flange-mounting

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Tank top return-line filter Pi 5000

Automatic back-flushing filter AutoFilt RF4

Process Inline Filter PLF1

Low pressure filter Spin-on cartridges PX

Series RFL In-Line Filter

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

HYDAC (Three-Phase Current) Compact Power Units CO1

Transcription:

FluidControl Off-line filter / cooler unit BKF In hydraulic systems oil transfers power and motion, and in drives it s a vital lubricant. Both as a power transfer medium and as a lubricant, oil is heated by friction losses during operation and changes its viscosity depending on the temperature. At the same time it is subjected to mechanical strain due to the tribological processes in the systems and takes on wear particles this causes. If these particles aren t removed as quickly as possible, they will cause further abrasion and wear. Hydraulic and lubrication systems therefore increasingly use bypass filters with built-in cooler. The advantage of these circuits is that they create stable and therefore more predictable operating conditions for both the filtration and cooling. The BKF series has compact gerotor pump/filter/water cooler combinations with different capacities, including custom. These compact units are combined with the extremely efficient BWT series plate heat exchangers. The filter housings are suitable for DIN 24550 filter elements. Features Compact, space-saving design DIN filter elements Easy installation Easy element replacement Efficient plate heat exchanger DA380002 01/2017 page 1 / 8 Buhler Technologies LLC, 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546 / 49 89-0, Fax: 248.652.1598 e-mail: sales@buhlertech.com Internet: www.buhlertech.com

Introduction and description Why off-line aggregates? Depending on the system configuration there are operating conditions (variable capacity pumps, back-flow peaks, etc.), which significantly limit the effectiveness of full flow filtration or even render it completely ineffective. In addition, quite practical considerations such as installing a cooler with is required anyway or the option of system-independent operation may argue for an off-line aggregate. Why Bühler? When we developed the BKF series, we incorporated our years of experience in designing and selling water coolers and filters. Special attention was paid to a compact design. By using standard filter elements in this respect we are not bound to a specific filter supplier. Together with a well-known manufacturer, Bühler implemented these findings in a comprehensive product line customised for the requirements in fluid control. Use the data in this leaflet to determine a suitable cooler for your application. If our standard range of products does not includes the right system for your application, we will gladly develop a custom solution for you. BKF 18/30 A low-noise gerotor pump resistant to dirt is integrated into the very compact baseplate. The drive motor and filter housing are arranged vertically and parallel to save space. The suction and pressure line are positioned so they can be routed straight down into the reservoir. This minimises the installation work. Since the baseplate is also equipped with front connections, the aggregate can be cased next to the reservoir. The aggregate has a built-in pressure limiting valve. NG 250 DIN elements are used as filter elements. BKF 60/90 A compact, space-saving design was also realised in this series. Motor, pump and filter housing are combined into one unit and mounted to a frame for side mounting. The DIN filter element with NG 400 removes to the top for changing. Planning information Installation site requirements Ensure adequate ventilation. The aggregates are mounted in the installation site using four screws Electrical connection The electrical connection must be made by an appropriately trained electrician! Observe the voltage and mains frequency! Fusing must comply with applicable standards! Please note the direction of rotation of the motor when connecting. Hydraulic connection Full utilisation of the high capacity of the aggregates requires care when configuring the intake line. This is a very important factor with use in lubricating systems. These are typically filled with higher viscosity oils and must operate reliably in a large temperature range. Although the tremendous increase in viscosity in low temperatures are frequently overlooked. For applications where the parameters are within critical ranges, we recommend calculating the precise expected pressure loss in the suction pipe or using an adequate size (never smaller than the existing pump suction port!). The suction and pressure pipe must be installed free from tension and vibration. When using hoses, pay particular attention to the appropriate reinforcement on the suction side so the hose cannot collapse due to the negative pressure. Do not continuously exceed the recommended suction pressure of the pumps. Some situations may require priming the suction pipe prior to first start-up. Avoid possible leaks in the circuit to prevent environmental damages. If necessary, use e.g. an oil pan. 2 Buhler Technologies LLC We reserve the right to amend specification. DA380002 01/2017

Technical data Technical data Pump housing: Gerotor: Hydraulic screw joint: Anodised and impregnated cast aluminium Sintered steel Galvanised steel Operating fluids: Mineral oils per DIN 51524 Operating oil temperature: Seal: max. 176 F (higher temperatures on request) Perbunan (NBR) or Viton (FPM) on request Ambient temperature: -4 F to 104 F Electric motors Voltage / frequency BKF 18: BKF 30: BKF 60/90: 230/400 V - 50 Hz ± 5 % 276/480 V - 60 Hz ± 5 % 220/380 V - 230/400 V - 240/415 V 50 Hz 460 V 60 Hz 220/380-245/420 V 50 Hz 220/380-280/480 V 60 Hz Thermal stability: Class of insulation F, utilisation per Class B Design: Protection class: on request: The motors comply with standards IEC 60034, IEC 60072, IEC 60085 three-phase asynchronous squirrel-cage induction motor totally enclosed, fan cooled IP55 other voltages higher motor power for higher viscosities UL- or CSA-approved motors higher protection class Please also observe the operating manual for the motor! All motors are supplied with cable gland inside the terminal box. The total height of the aggregate may vary by motor make. Installation information: The connection threads are manufactured to ISO 228. The screw-in surfaces are finished and suitable for the use of soft seals. We recommend using screwed plugs per ISO 1179-2. Please note: Especially note the dimension of the suction pipe. The cross-sections should not be smaller than specified. In most cases, loud noise indicates the cross-section was reduced too much. Please refer to the notices in the operating instructions. Wiring diagrams Accessories Wiring diagram BKF 18/30 Wiring diagram BKF 60/90 Accessories Optional: manometer or pressure gauge Optional: manometer or pressure gauge Water IN / OUT Inlet Output Inlet Output DA380002 01/2017 We reserve the right to amend specification. Buhler Technologies LLC 3

BKF 18 / BKF 30 Heat exchanger mount View A Oil OUT Water IN Screw-in connection Contamination indicator (optional) Plate heat exchanger Aggregate mounting diagram Water OUT Note: When installing next to the oil reservoir please not the intake! When determining the bores on the reservoir be sure the contamination indicators remains visible! Model: BKF 18-6-0.55* BKF 30-4-0.75-IE3** Motor power: 0.75 hp 1 hp Number of poles: 6 4 Power input (460 V 60 Hz): ~ 1.4 A ~ 1.4 A Motor service factor: 1.15 1.25 Suction lift: 3.28 ft 3.28 ft Filter element pressure limit: 87 psi 87 psi Display pressure contamination indicator: 32 psi 32 psi Suction end connection: G3/4 / G1 G3/4 / G1 Suction end hose: DN 20 / DN 25 DN 20 / DN 25 Pressure end connection: G3/4 G3/4 Pressure end hose: DN 20 DN 20 Suction pressure: -5.8 psi -5.8 psi For all aggregates briefly: -8.7 psi Connection "Water IN": G1/2 G1/2 Connection "Water OUT": G1/2 G1/2 Flow rate: 5.8 gpm 9.2 gpm Max. feed pressure: 87 psi 87 psi Weight: approx. 44 lb approx. 50 lb *Upon request: Electr. motor per NEMA, UL, CSA, EAC approval **Electr. motor per NEMA, UL, CSA, EAC approval 4 Buhler Technologies LLC We reserve the right to amend specification. DA380002 01/2017

BKF 60 / BKF 90 Oil OUT G1 1/4 2.83 2.24 Water IN G1 E-Motor 2.2kW IE3 4-pole / assy. 100 220/380-245/420V 50Hz 220/380-280/480V 60Hz 12.99 Filter housing NG400 Plate heat exchanger BWT B25x30-S 11.02 2.68 18.86 23.82 Water OUT Oil IN 0.87 Mounting bores 4x Ø0.39 0.79 22.24 16.93 1.61 Plug for drain bore Filter housing Note: When installing next to the oil reservoir please not the intake! When determining the bores on the reservoir be sure the contamination indicators remains visible! Contamination indicator (optional) Model: BKF 60-4-2.2-IE3* BKF 90-4-2.2-IE3* Motor power: 3.0 hp 3.0 hp Number of poles: 4 4 Power input (460 V 60 Hz): ~ 3.5 A ~ 3.5 A Motor service factor: - - Suction lift: 3.28 ft 3.28 ft Filter element pressure limit: 51 psi 51 psi Display pressure contamination indicator: 32 psi 32 psi Suction end connection: G1 1/2 G1 1/2 Suction end hose: DN 40 DN 40 Pressure end connection: G1 1/4 G1 1/4 Pressure end hose: DN 32 DN 32 Suction pressure: -5.8 psi -5.8 psi For all aggregates briefly: -8.7 psi Connection "Water IN": G1 G1 Connection "Water OUT": G1 G1 Flow rate: 18.3 gpm 27.9 gpm max. oil viscosity: 300 cst 100 cst at max. operating pressure 116 psi 116 psi Weight: approx. 101 lb approx. 104 lb *Upon request: Electr. motor per NEMA, UL, CSA, EAC approval DA380002 01/2017 We reserve the right to amend specification. Buhler Technologies LLC 5

Cooling capacity curves BKF 18 BKF 30 BKF 60 BKF 90 6 Buhler Technologies LLC We reserve the right to amend specification. DA380002 01/2017

Selecting the filter fineness Determining the contamination class per ISO 4406 >4 µm >6 µm >14 µm System type 13 11 8 Highly reliable control systems susceptible to sludge accumulations; laboratory or aerospace 14 16 12 13 9 10 High performance servo systems and high pressure systems with a long life; e.g. aviation, machine tool, etc. 17 15 11 High-quality, reliable systems: general machinery construction 20 17 12 General machinery construction and vehicles; moderate pressure, moderate capacity 23 19 13 General machinery construction and vehicles; low-pressure systems in heavy machinery construction Recommend filter retention rate Recommended element 1-2 Sm-N2 3-5 Sm-x3 Sm-x6 10-12 Sm-x10 12-15 Sm-x16 15-25 Sm-x25 / Mic 10 DA380002 01/2017 We reserve the right to amend specification. Buhler Technologies LLC 7

Ordering instructions Off-line filters Item no. Type Description 3902010 BKF 18 without contamination indicator NBR 3902110 BKF 18 mechanical contamination indicator NBR 3902210 BKF 18 electric contamination indicator NBR 3903020 BKF 30 without contamination indicator NBR 3903120 BKF 30 mechanical contamination indicator NBR 3903220 BKF 30 electric contamination indicator NBR 3906030 BKF 60 without contamination indicator NBR 3906130 BKF 60 mechanical contamination indicator NBR 3906230 BKF 60 electric contamination indicator NBR 3909030 BKF 90 without contamination indicator NBR 3909130 BKF 90 mechanical contamination indicator NBR 3909230 BKF 90 electric contamination indicator NBR Filter elements For type Item no. Description Filter fineness Purity class ** BKF 18 / BKF 30 3825003 N 0250 DN 3 3 µm 13/10 3825006 N 0250 DN 6 6 µm 14/10 3825010 N 0250 DN 10 10 µm 15/11 BKF 60 / BKF 90 3840003 N 0400 DN 3 3 µm 13/10 3840006 N 0400 DN 6 6 µm 14/10 3840010 N 0400 DN 10 10 µm 15/11 ** Purity classes achievable per ISO 4406 for BKF 18/30 at V = 300 L and 24 h Circulation time (approx. numbers) 8 Buhler Technologies LLC We reserve the right to amend specification. DA380002 01/2017