Installation Guide. The Expert in Lubrication Solutions

Similar documents
Installation Guide perma CLASSIC

Installation Guide perma STAR VARIO

perma CLASSIC The world's best selling lubrication system

The World of Automatic Lubrication. perma Lubrication Systems for. Conveyors

perma-tec GmbH & Co. KG Lubrication Systems ZE RTIFIZI E RT E S Lubrication Systems

Operating Instructions MP 6. perma-tec GmbH & Co. KG perma MP 6 perma-tec GmbH & Co. KG perma MP 6

The World of Automatic Lubrication. perma Lubrication Systems for. Recycling Plants

Townsend Bearings. Perma Lubrication Systems

perma Lubrication Systems in Cement Plants The World of Automatic Lubrication

perma FLEX Quick Reference Pocket Guide

perma STAR VARIO Operating Instructions The World of Automatic Lubrication

The World of Automatic Lubrication. perma Lubrication Systems in. Power Plants

The World of Automatic Lubrication. perma Lubrication Systems for. Escalators

Operating Instructions STAR CONTROL IMPULSE

The Expert in Lubrication Solutions. perma Lubrication Systems for Electric Motors

STAR CONTROL. Operating Instructions. EC Conformity Declaration. perma-tec GmbH & Co. KG perma STAR CONTROL perma-tec GmbH & Co. KG perma STAR CONTROL

TIMKEN SINGLE-POINT LUBRICATION SYSTEMS

perma FUTURA Quick Reference Pocket Guide

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Mini pressure switch Stainless steel switch enclosure Model PXS

Klübermatic Accessories

Load cell PR for maximum corrosion resistance. Load cell PR 6212 benefits. Mounting kit PR 6012 benefits

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Surface thermocouple Model TC50

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Conveyor systems Automatic lubrication systems in use

Installation Instructions

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Compact temperature switch Model TCS

Mini temperature switch Stainless steel switch enclosure Model TXS

The Expert in Lubrication Solutions. perma Lubrication Systems for. Conveyors

smart lubrication Single Point Lubricator The Compact and Refillable Single-Point Lubricator worldwide patents

perma Automatic Lubrication Systems

CHAIN LUBRICATION WITH BRUSH OF

HTL perma Australia Pty Ltd

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5190 Trough hole (annular) heavy capacity load cell

Compact pressure switch Model PCS

Gas-actuated temperature switch Stainless steel switch enclosure Model TWG

Ex m Solenoid Operator Type 0519

CMS Electric Cylinder. Addendum to the Operating Instructions. Edition 11/ / EN

Automatic single-point lubricator The compact and refillable single-point lubricator

Compact differential pressure switch Models DC, DCC

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Single Point Lubricator The Compact and Refillable Single-Point Lubricator

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

The Compact and Refillable Single-Point Lubricator

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Electronic Limit Switch Type

smart lubrication Single Point Lubricator The Compact and Refillable Single-Point Lubricator Swiss made / worldwide patents

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Series 3730 Electropneumatic Positioner Type

Ö S T L I N G Markiersysteme GmbH. Broßhauser Str Solingen - Deutschland

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Siemens Drives & PLCs

Operating Instructions

Assembly instructions

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Type 6213 EV, 6281 EV

Spare parts list. Hydraulic breakers RX Valid from serial number

We have a system for effective lubrication. Klübermatic lubricant dispensers

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

AUTOMATIC LUBRICATION

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Operating Instructions. Angle Seat Control Valve. Type 7020

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

perma STAR VARIO Operators pocket guide

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Technical Data. Dimensions

IECEx Certificate of Conformity

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

Integrated Control modules

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Paddle Flow Monitor Model PSR/PSE

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

The Compact and Refillable Single Point Lubricator

I Ex-Safety switches I

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Spare parts list. Hydraulic breakers RX Valid from serial number

Operating Instructions

Cable resistance thermometer Model TR40

Type Electronic Limit Switch

Compact Sheet-steel Emergency Light Fitting Series 6118/1

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

MG 300. Spare parts list. Multi grapple Atlas Copco Construction Tools GmbH No

The Compact and Refillable Single Point Lubricator

Capacitive Sensors. Series 80 - PNP

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Integrated Control modules

CoriolisMaster FCB430, FCB450, FCH430, FCH450 Coriolis Mass Flowmeter

Rotary feed-through DDF-S/-KS

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Position Switches Series 8074/2

Control Buttons / Switches for Panel Mounting Series 8003

OPTIMASS 3000 Technical Datasheet

Thermocouple For additional thermowell Model TC10-B

WARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.

Transcription:

Installation Guide perma FLEX ID 442762_en.02 The Expert in Lubrication Solutions

Basic Guidelines 3 1. 2. Mounting types Direct mounting Remote mounting with tube Mounting of oil filled units 4-6 3. Preparation of lubrication point 7 4. Pressure testing Pressure test procedure 9 5. Activation und installation 11 6. Identification of lubrication system 11 2016 perma-tec GmbH & Co. KG The content of this document has been compiled by perma-tec with mediculous care. Never-the-less, we cannot rule out deviations and reserve the right to make technical changes to the product without any advance notice. We do not assume any judicial responsibility or liability for any damages which may ensue as a result. Necessary modifications will be included in subsequent editions. Compiled and printed: 03/2016 2

This Installation guide provides instructions for the installation of perma FLEX and helps in preventing basic Schlauchanschlüsse mounting errors. The guide should be used with the operating instructions. Drawings are only examples. There are many other possibilities for mounting, depending on local conditions. Disclaimers of corresponding operating instructions apply. Installation guides do not affect validation of the operating instructions. 1. Basic Guidelines perma FLEX is a single-point lubrication system. You must use a separate lubrication system for each lubrication point. The connection thread of perma FLEX is BSP R¼ male thread. Replace the application s grease fitting with a suitable reducer. perma-tec offers a wide assortment of reducers, extensions, tubes, brackets and other accessories. See our product catalogue for the entire overview on perma accessories. Ensure that the lube point is prefilled with fresh lubricant before installation. perma-tec offers all of its lubricants in 400 g cartridges for grease guns. Select the right lubricant for your application. perma-tec offers a wide variety of standard lubricants for different applications. See our product catalogue for further information. Use medium strength threadlocker for all metal to metal connections (extensions, reducers etc.). Fill grease lines and accessories with the same lubricant that is contained in the lubrication system. perma FLEX can be used for saltwater aplications (underwater usage is possible for a limited time). Protection class IP 68. For managing serveral lube points we recommend the use of a lubrication maintenance plan. You can use the free perma MLP software (https://mlp.perma-tec.com) for online administration. Please check our product catalogue for more information on how to select suitable lubricant. You may also download our free perma SELECT APP which is a great tool for the selection of the right lubrication system, lubricant and discharge period. 2016 - perma-tec GmbH & Co. KG www.perma-tec.com 3 Art. No. Anschlussteile

2. Mounting types 2.1 Direct mounting Direct mounting should be preferred for all lubrication points, to protect the lubrication system against high pressure. Reducer for thread connection Installation of perma FLEX is possible in all directions. 4

2.2 Remote mounting with tube Remote mounting is recommended if, the ambient temperature of the lubrication point is permanently higher than +60 C the lubrication point is exposed to high vibrations no direct access to lubrication point is possible due to safety issues (e. g. removal of protective screens, safety walls or cages) it is difficult or dangerous to access the lubrication point the lubrication system is exposed to mechanical forces (e. g. falling rocks) Mounting bracket 1-point G1/4 female (109685) Hose connector G1/4 male for hose iø 9.5 mm - push-lock (101554) Heavy Duty hose up to +100 C oø 16 mm x iø 9.5 mm (101555) Hose connector G1/4 male for hose iø 9.5 mm - push-lock (101554) Reducer for thread connection Sealing of metal thread connections necessary (e. g. medium strength thread locker). Keep connection lines as short as possible and use tubes with an inside diameter of at least 6 mm. Keep in mind that tube length and bore diameter of bearing housings affect pressure and discharge period of the lubrication system. For installation of perma FLEX use Mounting bracket 1-point G1/4 female (109685). Secure tubes with suitable fastenings (brackets, cable ties) to protect against damage and tearing. Depending on lubricant and ambient temperature, different tube lengths are possible, e. g. perma Multipurpose grease SF01: 1 m (+20 C) perma Multipurpose oil SO32: 3 m (+20 C). 2016 - perma-tec GmbH & Co. KG www.perma-tec.com 5

2.3 Mounting of oil filled units 2.3.1 Direct mounting All oil filled perma FLEX come with an integrated oil retaining valve. They can be installed directly on a lubrication brush without the need for an additional oil valve. Sealing of metal thread connections necessary (e. g. medium strength thread locker). Insert for bracket G1/4 male x G1/4 female (104820) Bracket (104864) Oil brush Ø20 mm G1/4 female (101396) 2.3.2 Remote mounting Remote installations of oil filled perma FLEX require an oil retaining valve at the lowest point of the application. This will prevent oil leakage from the lubrication system. Mounting bracket 1-point G1/4 female (109685) Tube connector G1/4 male for tube oø 8 mm straight (101496) Tube up to +80 C oø 8 mm x iø 6 mm (101393) Sealing of metal thread connections necessary (e. g. medium strength thread locker). Bracket (104864) Tube connector G1/4 male for tube oø 8 mm straight (101496) 6 Oil retaining valve G1/4 male x G1/4 female up to +60 C (104862) Oil brush 40 x 30 mm G1/4 female (101397)

3. Preparation of lubrication point 1. Prior to installation, lubrication point must be cleaned to protect against contamination. 2. Remove grease nipple or plug screw of connecting thread and check thread size. 3. Insert reducer and install tube and necessary accessory parts. 2016 - perma-tec GmbH & Co. KG www.perma-tec.com 7

4. Lubrication point, accessory parts and tubes must be pre-filled with lubricant. This enables the lubricant to immediately reach the lubrication point. Grease gun (101455) Hose with rotary joint, slide and hydraulic coupling for grease gun (110199) Tube prefill adapter 5. Prefill lubrication point and all grease lines for remote installation. 6. Use a tube prefill adapter to prefill lubrication point and grease lines. Tube prefill adapter for tube oø 8 mm (101526) Tube prefill adapter for tube oø 6 mm (101532) Hose prefill adapter for Heavy Duty hose (107633) Tube prefill adapter for VA-flex tubes (107634) 8

4. Pressure testing Check counter pressure at lubrication point before installing the lubrication system to guarantee correct function. Most bearings require 0.5-2 bar pressure (without extension tubes). perma FLEX can be used for these lubrication points. perma STAR VARIO Gauge Stop valve Accessory set for pressure test For pressure testing please use perma STAR VARIO with Accessory set for pressure test (101480). Be sure to use the same lubricant for both, prefilling and LC of perma STAR VARIO. Accessory set for pressure test (101480) (order lubrication system separately) 2016 - perma-tec GmbH & Co. KG www.perma-tec.com 9

4.1 Pressure test procedure 1. Remove grease nipple. 2. Screw reducer onto lube point and connect pressure testing set. 3. Connect perma STAR VARIO to the open outlet. 4. Turn machines on to ensure that lube point is in use and measuring of corresponding counter pressure is possible (Caution: Observe accident prevention regulations). 5. Open stop valve. 6. Push SET button on perma STAR VARIO for approx. 10 seconds until PU lights up on display to trigger an additional discharge/purge. 7. Watch the pressure on the gauge during the additional discharge. If pressure exceeds 6 bar the lubricator will shut off automatically. 8. If pressure doesn t rise any more during the additional discharge, max injection pressure has been reached. In order to find out the required system pressure you must wait another 5 minutes. The gauge will then show the system pressure 9. If system pressure exceeds 2 bar you need to purge the lube point by using a mechanical grease gun. Proceed with steps 6 and 7. 10. If counter pressure doesn t decrease you need to either select a different lubricant or a different lubricator. Please ask perma-tec to assist you in this matter perma ACADEMY 10

5. Activation und installation Start up as following (also refer to operating instructions): 1. Use a coin to turn the rotary switch to set the desired discharge period 2. Note activation / exchange date on label 3. Remove plug and screw lubricator into lube point 6. Identification of lubrication system The label of the lubrication system shows product-code, manufacturing date, traceability number, lubricant code and part number. IP level: 68 II 1 G Ex ia IIC T6 II 1 D Ex iad 20 T85 C I M1 Ex ia I DEKRA 12ATEX0006 X -20 C<Ta<+60 C Ex ia IIC T6 Ga Ex ia IIIC T85 C Da Ex ia I Ma IECEx DEK 11.0103X IS/I,II,III/1/ABCDEFG/T6(85 C); -25 C<Ta<+65 C;IP68 I/1/AEx/Exia/IIC/T6; -25 C<Ta<+65 C;IP68 WARNING - POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS FLEX manufactured by: perma-tec GmbH & Co. KG Hammelburger Str. 21 97717 EUERDORF www.perma-tec.com Tel.: +49 9704 609-0 Made in Germany 1/1 3/4 1/2 FLEX 125 Lubrication System 1/1 3/4 1/2 +60 C 140 F -20 C -4 F 04/16 10/16 1/4 1/4 Art. No. 123456 CL-1609-37337 perma Multipurpose grease SF01 125 cm³ / 4.23 fl.oz. (US) Installation date and exchange date (to be added by operator) Art. No. Serial number (Product designation year/week of manufacture internal no.) Lubricant designation 2016 - perma-tec GmbH & Co. KG www.perma-tec.com 11

2016/03 Version: 2.0 en