Series ITV009. Compact Vacuum Regulator ITV IITV00 02 n. RoHS. How to Order

Similar documents
Electro-Pneumatic Regulator Electronic Vacuum Regulator

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV1000/2000/3000

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

4 Note 1) Value for communications type. (PROFIBUS DP)

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Low Torque Metal Seal Type Rotary Joint. MQR Series

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Pressure Relief 3 Port Valve With Locking Holes

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

Coolant valve. SGC/SGH Series

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

Speed Controller with Indicator

Digital Flow Switch (Remote type sensor unit)

SI unit for AS-Interface EX250-SAS#

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

Solid State Auto Switch D-M9#A#

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

Regulator Valve. VEX1 Series

Digital Gap Checker. ISA3 series

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

Series AV2000/3000/4000/5000

Digital Gap Checker. ISA3 series

Doc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series

Series 10-ZSE40A(F)/10-ISE40A

Electro-pneumatic proportional valve

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series

Direct Operated 3-port solenoid valve

Low Differential Pressure Sensor ±1% F.S.

2-Color Display High-Precision Digital Pressure Switch

Pressure Sensor for General Fluids PSE570/573/574

49.5 mm Overall. 30 mm MXZ ø20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ø12, ø16, ø20, ø25. MXZ ø20, 10 mm stroke.

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Digital Flow Switch (Remote type monitor unit)

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

SI unit for Ethernet POWERLINK

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Doc. no.ck1*-om0066p. PRODUCT NAME Clamp Cylinder. MODEL / Series / Product Number


2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Digital Flow Switch PFM7##

Vacuum pump system type

SI unit for EtherCAT. EX260 Series

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC

Digital Flow Switch (Integrated display type)

Digital Pressure Switch

High Vacuum L Type Valve

AV2000-A/3000-A/4000-A/5000-A

Digital Flow Switch (Integrated display type)

Digital Pressure Switch

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Digital pressure switch for energy-saving control ejector

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

2-Color Display High-Precision Digital Pressure Switch

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

NAMUR Interface 5 Port Solenoid Valve

Doc. no.mx*-omp0038-d PRODUCT NAME AIR SLIDE TABLE. MODEL / Series / Product Number

Lock unit MWB*32&100-UT-* MWB*32&100TN-UT-* MWB*32&100TF-UT-*

New Concept Connector Type Manifold

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Two Hand Control Valve

Compact Proportional Solenoid Valve

3 Port 3 Position Valve

Air Catch Sensor ISA2

Model Pressure range ON/OFF output Linear output

Related vacuum products

Fieldbus System (Output device for driving 5 port solenoid valves)

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

2-Color Display Digital Pressure Switch

25% reduction in volume * PB1013A/Air-operated type without foot

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series

No. MGP*-OM0047P-B PRODUCT NAME. Remodeled. MODEL / Series / Product Number. Series MGP-Z

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Transcription:

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (8) 6-8 www.cmafh.com 7 For single unit and single unit for manifold ITV 9 Pressure range 9 kpa Built-in One-touch fittings type For single unit Symbol VACz OUTx ATMc Nil U Metric size (Light gray) Inch size (Orange) ø ø/" For manifold Symbol Metric size Nil (Light gray) Inch size U (Orange) Manifold IITV n Compact Vacuum Regulator Series ITV9 Power supply voltage VDC ±% to VDC Stations stations stations stations VACz ø6 ø/" OUTx ATMc ø ø6 ø/" Input signal Current type to ma DC Current type to ma DC Voltage type to VDC Voltage type to VDC How to Order ø/" Option If a DIN rail longer than the specified stations is required, specify the applicable stations in two digits. (Maximum stations) Example) IITV--7 Note) A DIN rail with the length specified by the number of stations is attached to the manifold. For dimensions of the DIN rail, refer to the external dimensions. Nil M N Bracket/Option for single unit only Nil Without bracket Flat Bracket B C Base type Cable connector (Option) N Without cable connector S Straight type m L Right angle type m L-bracket For single unit For manifolds How to Order Manifold Assembly (Example) Indicate the part numbers of electro-pneumatic regulators and options to be mounted below the manifold part number. Example) Due to the common supply/exhaust feature, note that different pressure range combinations are not available. IITV- set (Manifold part no.) ITV9-MS sets (Vacuum regulator part no. (, stations)) ITV9-ML set (Vacuum regulator part no. ( stations)) Indicate part numbers in order starting from the first station on the D side. Note) Combination with having different pressure ranges is not available due to common supply/exhaust features. The asterisk ( ) specifies mounting. Add an asterisk ( ) at the beginning of electro-pneumatic regulator part numbers to be mounted. ITV9-MS ITV9-ML D side [Option] DIN rail RoHS CE compliant Nil Q CE compliant For detailed information on models for CE, refer to the SMC's website.

Accessories (Option) Bracket Flat bracket assembly (including mounting screws) P98 L-bracket assembly (including mounting screws) P98 Tighting torque when assembling is. N m. Compact Vacuum Regulator Series ITV9 Specifications Model Minimum supply pressure Maximum supply pressure Set pressure range Maximum flow rate Voltage Power supply Current consumption Voltage type Input signal Current type Voltage type Input impedance Current type Analog Output signal output Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Operating temperature range Enclosure Connection type For single Metric size unit Inch size Connection size Metric size Manifold Inch size Weight Note ) Cable connector Straight type M8-DSXMG ITV9 Set pressure kpa kpa to kpa l/min (ANR) (Supply pressure: kpa) VDC ±%, to VDC Power supply voltage VDC type:. A or less Power supply voltage to VDC type:.8 A or less Right angle type ELWIKA-KV8 PVC M to VDC, to VDC to ma DC, to ma DC Approximately kω Approximately Ω to VDC (Load impedance: kω or more) Output accuracy: Within ±6% (Full span) Within ±% (Full span) Within.% (Full span) Within ±.% (Full span) Within.% (Full span) Within ±.% (Full span)/ C to C (No condensation) IP6 equivalent Built-in One-touch fittings z, x, c: ø z, x, c: ø/" z, c: ø6, x: ø z, c: ø/", x: ø/" g or less (without option) Note ) Indicates the weight of a single unit. For IITV-n Total weight (g) Stations (n) x + (Weight of end block A, B assembly) + Weight (g) of DIN rail Note ) When there is a downstream flow consumption, pressure may become unstable depending on piping conditions. When using under the conditions equivalent to IP6, connect the fitting or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) 8

Series ITV9 Working Principle When the input signal rises, the air supply soloenoid valve q turns ON. Due to this, part of the supply pressure passes through the air supply solenoid valve q and changes to output pressure. This output pressure feeds back to the control circuit r via the pressure sensor e. Here, pressure corrections continue until output pressure becomes proportional to the input signal, enabling output pressure that is proportional to the input signal. 9 Input signal Power supply Input signal q Air supply solenoid valve VAC ATM + r Control circuit Diagram of working principle e Pressure sensor Power supply and error LED indication r Control circuit Block diagram Supply pressure q Air supply solenoid valve w Exhaust solenoid valve Discharged to atmosphere Output signal w Exhaust solenoid valve OUT e Pressure sensor Output pressure

Series ITV9 Linearity, Hyteresis Output deviation factor (% F.S.).. 7 Pressure Characteristics Output deviation factor (% F.S.).. Return Out Input signal (%F.S.) Out Return 8 6 Supply pressure (kpa) Set pressure: kpa Compact Vacuum Regulator Series ITV9 Repeatability Output deviation factor (% F.S.).. Flow Characteristics Set pressure (kpa) 6 8 kpa kpa kpa 6 kpa 8 kpa kpa Count With % of signal input.... Flow rate (l/min (ANR))

Series ITV9 Dimensions For Single Unit Port Location No. ITV9 z x c VAC OUT 9 ATM Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) L-bracket (Option) M8 x Cable connection thread Note) Breathing hole (M x.) OUT port (ø, ø/") L-bracket (Option) 7 + ø Cable connector (-wire) Straight type (Option) (.9) 8.7 9.9 7 8 8 Cable connector (-wire) Right angle type (Option).6 8 ø M8 x ø9.7 x ø6 depth of counterbore 88 x ø. 9 9 OUTx x M x. thread depth. Bracket mounting hole 6.7.7 Flat bracket (Option) 7 9 6 Flat bracket (Option) Minimum bending radius 8 Minimum bending radius 8 x ø6 depth of counterbore. 89 VACz ATMc x ø. Body Body VAC port (ø, ø/") ATM port (ø, ø/").7 8

Dimensions Single unit for manifold 8 Note) Breathing hole (M x.) 86 OUT port (ø, ø/") Note) When using under the conditions equivalent to IP6, connect the fittings or tube to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page ) OUTx Bushing assembly Note) For dimensions of the cable connector, refer to single unit on page. Compact Vacuum Regulator Series ITV9 9.7 6 M8 x Cable connection thread 6. 8. 8.7

Series ITV9 Dimensions Manifold Port Location No. z x c ITV9 VAC OUT ATM Note) Stations are counted starting from the D side. 6 9 (8) Dimensions in inch are noted in parentheses. OUTx port (ø, ø/").7 Note) For dimensions of the cable connector, refer to single unit on page. Manifold stations n L L Weight of DIN rail (g) 6. 7 VACz port (ø6, ø/") ATMc port (ø6, ø/") 9 8 7 6. 9 6 7 7 8. 8 (mm) 8. x M x. thread depth Mounting hole 8 98 6 9 6 6. D side 9. L L stations 9. U side 6. Note) Breathing hole (M x.) 89. Note) When using under the conditions equivalent to IP6, connect the fittings or tubing to the breathing hole prior to use. (For details, refer to "Specific Product Precautions " on back page )

Input signal/ Communication model Current type to ma DC (Sink type) Current type to ma DC (Sink type) CC DN PR RC Voltage type to VDC Voltage type to VDC Preset input CC-Link DeviceNet PROFIBUS DP RS-C communication Electronic Vacuum Regulator Series ITV9/9 ITV 9 S Pressure range 9. to 8 kpa Power supply voltage VDC to VDC Note) Communication models are available only for V DC. Nil Monitor output Analog output to VDC Switch output/npn output Switch output/pnp output Analog output to ma DC (Sink type) None How to Order Bracket Nil B C Port size / Thread type Nil N T F Rc NPT NPTF G [Option] CE compliant Nil Q CE compliant Pressure display unit kpa Note) For the communication models, CC, DN, PR and RC, only Nil is available as it does not have a pressure display. Cable connector type S Straight type m L Right angle type m N Without cable connector Note) Order communication cable (other than RS-C) separately. See below. Without bracket Flat bracket L-bracket For communications cables, use the parts listed below (refer to the catalog [M8/M Connector] CAT.ES-7 for details) or order the product certified for the respective protocol (with M connector) separately. Application Communication cable part number Remarks CC-Link compatibility PCA-677 (Socket type) Dedicated Bus adapter supplied PCA-6777 (Plug type) with the product. DeviceNet PROFIBUS DP PCA-76 (Socket type) PCA-7688 (Socket type) compatibility compatibility PCA-766 (Plug type) PCA-769 (Plug type) T-branch connector not supplied. T-branch connector not supplied. RoHS

Series ITV9/9 Stepless control of vacuum pressure in proportion to an electrical signal Piping/Wiring Diagram Power supply and input signal (VDC, ma DC) VAC Vacuum pump, Ejector ITV9 OUT Tank Set pressure (Vacuum) Standard Specifications Model Voltage Power supply Current consumption Note ) Minimum supply vacuum pressure Maximum supply vacuum pressure Set pressure range Note ) Current type Input signal Input impedance Output signal (Monitor output) Linearity Hysteresis Repeatability Sensitivity Temperature characteristics Output pressure Accuracy display Units Ambient and fluid temperature Enclosure Note 7) Weight Note ) Voltage type Preset input Current type Voltage type Preset input Analog output Switch output Communication Specifications (CC, DN, PR, RC) Model Protocol Version Note ) Communication speed Configulation file Note ) I/O occupation area (input/output data) Communication data resolution Fail safe Terminating resistor ITV -CC CC-Link Ver. bit (96 resolution) ITV9 ITV9 VDC ±% to VDC Note 6) Power supply voltage VDC type:. A or less Power supply voltage to VDC type:.8 A or less Set pressure. kpa kpa. to 8 kpa to ma DC, to ma DC to VDC, to VDC points (Negative common) Note ) Ω or less Approximately 6. kω Power supply voltage VDC type: Approximately.7 kω Power supply voltage VDC type: Approximately. kω to VDC (Load impedance: kω or more) to ma DC (Sink type) (Load impedance: Ω or less) Output accuracy within ±6% (Full span) NPN open collector output: Max. V, 8 ma PNP open collector output: Max. 8 ma Within ±% (Full span) Within.% (Full span) Within ±.% (Full span) Within.% (Full span) Within ±.% (Full span)/ C ±%F.S. digit kpa Note ) Minimum display: to C (No condensation) IP6 g Note ) The minimum supply vacuum pressure should be. kpa less than the maximum vacuum pressure setting value. Note ) to ma DC is not possible with the -wire type. Power supply voltage ( VDC or to VDC) is required. Note ) Value for the state with no over current circuit included. If an allowance is provided for an over current circuit, the input impedance varies depending on the input power supply. This is Ω or less for an input current of ma DC. Note ) Either analog output or switch output must be selected. Furthermore, when switch output is selected, either NPN output or PNP output must also be selected. Use caution that the preset input type is not equipped with an output signal function. Note ) Please contact SMC regarding indication with other units of pressure. Note 6) For communication models, the maximum current consumption is.6 A or less. Note 7) For communication models, add roughly 8 g to the weight ( g for the PROFIBUS DP). ITV -DN DeviceNet Release. EDS 6 bit/6 bit bit (96 resolution) Note ) Note that version information is subject to change. Note ) Configulation files can be downloaded from the SMC's website: http://www.smcworld.com Note ) The output HOLD value when a CC-Link communications error occurs can be set based on the bit area data. 6 k/6 k. M/ M/ M bps word/ word, bit/ bit (per station, remote device station) HOLD Note ) /CLEAR (Switch setting) k/ k/ k bps HOLD/CLEAR (Switch setting) ITV -PR PROFIBUS DP DP-V 9.6 k/9. k/. k 9.7 k/87. k/ k. M/ M/6 M/ M bps GSD 6 bit/6 bit bit (96 resolution) CLEAR Built into the product (Switch setting) ITV -RC RS-C 9.6 kbps bit ( resolution) HOLD

Working Principle Power supply Input signal q Vacuum pressure solenoid valve r Diaphragm VAC. (Vacuum pump, etc.) ATM (Atmospheric pressure) Series ITV9 Linearity Output pressure (kpa) 6 8. 7 Pressure Characteristics Output deviation factor (% F.S.) Set point... Pressure display i Control circuit Input signal (% F.S.) Set pressure: kpa 8 6 VAC. side pressure (Supply pressure) (kpa) Output signal w Atmospheric pressure solenoid valve.. Working Principle When the input signal increases, the vacuum pressure solenoid valve q turns ON, and the atmospheric pressure solenoid valve w turns OFF. Because of this, VAC. and the pilot chamber e are connected, the pressure in the pilot chamber e becomes negative and acts on the top of the diaphragm r. As a result, the vacuum pressure valve t which is linked to the diaphragm r opens, VAC. and OUT. are connected, and the set pressure becomes negative. This negative pressure feeds back to the control circuit i via the pressure sensor u. Then, a correct operation works until a vacuum pressure proportional to the input signal is reached, and a vacuum pressure is obtained which is always proportional to the input signal. Input signal + t Control circuit Block Diagram VAC.. 7 6 8 Input signal (% F.S.) Count 6 7 8 9 Atmospheric pressure u Pressure sensor e Pilot chamber t Vacuum pressure valve OUT. (Set pressure) y Atmospheric pressure valve Hysteresis Output deviation factor (% F.S.) Set pressure (kpa) Electronic Vacuum Regulator Return Out Flow Characteristics Flow rate (l /min(anr)) q Vacuum pressure solenoid valve w Atmospheric pressure solenoid valve u Pressure sensor... r Diaphragm Repeatability Output deviation factor (% F.S.) Series ITV9 Pilot valve Set pressure Supply vacuum pressure: kpa Flow characteristics measurement conditions Exhaust flow rate of the vacuum pump used for measurement: l/min (ANR) Inlet vacuum pressure: kpa (When outlet flow rate is l/min (ANR)) Maximum flow rate: l/min (ANR) (With inlet vacuum pressure at 9 kpa) 6

Series ITV9 Dimensions ITV9 Flat bracket () 9 L-bracket 7 ATM. (Atmospheric pressure) (8.) 8. 6 M x Connector (Plug type) M x.8 Breathing hole OUT (Set pressure) 7 x R..6 x ø7 Mounting hole Note) Do not attempt to rotate the cable connector, as it does not turn. Right angle type (-wire) Cable connector m Flat bracket assembly KT-ITV-F (Option) x M x.8 thread depth 6 mm through L-bracket assembly KT-ITV-L (Option) 6. Straight type (-wire) Cable connector m Rc / VAC. port x Rc / ATM. port, OUT port () VAC. (Vacuum pressure). () 99

Dimensions (CC-Link, DeviceNet, PROFIBUS DP and RS-C) CC-Link/ITV9-CC () Dimensions not shown are as on page 7. PROFIBUS DP/ITV9-PR M x Communication cable connection thread (Socket type).. (6) Dimensions not shown are as on page 7. With power cable connector ITV9- CC DN PR RC M x Communication cable connection thread (Socket type) M x Power cable connection thread (Plug type) () M x.8 Air introduction port 6 () M x.8 Air introduction port BUS adapter common dimensions M x Communication cable connection thread (Plug type) 8. x Rc / ATM. port, OUT port Rc / VAC. port M x Communication cable connection thread (Plug type) 6 9. x Rc / ATM. port, OUT port Electronic Vacuum Regulator Rc / VAC. port Straight type (-wire) Cable connector m DeviceNet /ITV9-DN M x Communication cable connection thread (Plug type) Dimensions not shown are as on page 7. RS-C/ITV9-RC () M x Communication cable connection thread (Plug type) Dimensions not shown are as on page 7. Series ITV9 M x Power cable connection thread (Plug type) Note) Do not attempt to rotate the cable connector, as it does not turn. () M x.8 Air introduction port ATM. OUT VAC. ATM. OUT VAC. 6 8. x Rc / ATM. port, OUT port M x Power cable connection thread (Plug type) () M x.8 Air introduction port ATM. OUT VAC. ATM. OUT VAC. 6 Right angle type (-wire) Cable connector m 8. x Rc / ATM. port, OUT port Rc / VAC. port Rc / VAC. port 8

Series ITV9 Accessories (Option)/Part No. L-bracket assembly Power cable connector Dimensions Description Flat bracket assembly Flat bracket x ø7.6 Straight type m Right angle type m Bus adapter (CC-Link model only) 9 6 8 6 8 x ø. x ø. 7 L-bracket 7 (8.) 6 7 Part no. KT-ITV-F KT-ITV-L P98-- P98-- EX9-ACY-MJ 6 x R. 8 x ø. x ø..

Safety Instructions : Warning: Danger : Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully.. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog.. An application which could have negative effects on people, property, or animals requiring special safety analysis.. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Back page indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. Danger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO : Pneumatic fluid power General rules relating to systems. ISO : Hydraulic fluid power General rules relating to systems. IEC 6-: Safety of machinery Electrical equipment of machines. (Part : General requirements) ISO 8-: Manipulating industrial robots - Safety. etc.. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and Disclaimer. The warranty period of the product is year in service or. years after the product is delivered. ) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product.. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ) Vacuum pads are excluded from this year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. Be sure to read Handling Precautions for SMC Products (M-E-) before using.

Series ITV/// Specific Product Precautions Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Air Supply. Install an air filter near this product on the supply side. Select a filtration degree of μm or less.. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.. If large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to SMC's "Air Preparation Systems". Wiring Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Terminal No. Lead wire color Wiring Power Signal COM Monitor : () : () : () : () Wiring Diagrams Current signal type Vs A Note) Vs: Power Supply VDC ±% to VDC A : Input signals to ma DC to ma DC Monitor output wiring diagram Analog output, voltage type Monitor output voltage Series ITV/9 Precautions Body Note) A right angle type cable is also available. The entry direction for the right angle type connector is to downwards (SUP port side). Never turn the connector as it is not designed to turn. Using force to turn the connector will damage the connector coupling. Voltage signal type Vs Vin Vs : Power Supply VDC ±% to VDC Vin: Input signals to VDC to VDC Handling. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment.. If electric power is shut off while pressure is being applied, pressure will be retained on the output side. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc.. If power to this product is cut off due to a power failure, etc. when it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out.. If supply pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off.. This product is adjusted for each specification at the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can lead to malfunction. 6. The optional cable connector is a wire type. When the monitor output (analog output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction. 7. Please note that the right angle cable does not rotate and is limited to only one entry direction. 8. Take the following steps to avoid malfunction due to noise. ) Remove power supply noise during operation by installing a line filter, etc. in the AC power line. ) For avoiding the influence of noise or static electricity, install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. ) Be sure to implement protective measures against load surge for induction loads (solenoid valves, relays, etc.). 9. The product characteristics are confined to the static state. When air is consumed on the output side, and especially used in the system with large leakage, pressure cannot approach the set pressure and the service life is drastically shortened with a humming noise of the solenoid valve.. For details on the handling of this product, refer to the instruction manual which is included with the product.. In locations where the body is exposed to water, dust, etc., there is a possibility that moisture or dust could enter the body through the breathing hole. Mount a fitting and tube (M-AU- fitting and TIUm-mm tube recommended) onto the breathing hole and run the tube to a location not exposed to moisture or dust, etc. Breathing hole M x.. If this product will be used in a sealed environment, such as inside an inspection box, a ventilation fan should be installed to ensure adequate ventilation as this product can generate heat in some operating conditions. When the power is turned on, a noise may be generated as a means of checking the operating condition of the solenoid valve. This noise is normal and does not indicate a fault. Back page

Warning Series ITV/// Specific Product Precautions Piping. Screw piping together with the recommended proper torque while holding the side that has female threads. Looseness or faulty sealing will occur if tightening torque is insufficient, while thread damage will result if the torque is excessive. Furthermore, if the side with the female threads is not held while tightening, excessive force will be applied directly to piping brackets, etc. causing damage or other problems. Connection thread Torque. Do not allow twisting or bending moment to be applied other than the weight of the equipment itself. Provide separate support for external piping, as damage may otherwise occur.. Since excessive moment loads and the propagation of vibrations, etc. can easily result from inflexible piping made of materials such as steel, avoid these problems by using flexible tubing for intermediate connections.. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe.. Wrapping of pipe tape When screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealing material do not get inside the piping. Also, when pipe tape is used, leave. to thread ridges exposed at the end of the threads. Back page Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Expose approx. threads Series ITV///9 Precautions Recommended proper torque: N. m /8 / /8 / 7 to 9 to to 8 to Wrapping direction Pipe tape Warning Operating Environment. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, or where there will be contact with the same.. Do not operate in locations where vibration or impact occurs.. In locations where the body is exposed to water, steam, dust, etc., there is a possibility that moisture or dust could enter the body through the EXH (solenoid) ports, thereby causing problems.. To overcome this, simply install tubing to each port, using the fittings, and extend the tubing so that the other end is at a location where no water splash, etc. occurs. Make sure not to bend, or block the I.D. of the tubing as this will have a detrimental affect on the pressure control.. Do not operate in locations where vibration or impact occurs.. In locations which receive direct sunlight, provide a protective cover, etc.. In locations near heat sources, block off any radiated heat. 6. In locations where there is contact with spatter from water, oil or solder etc., implement suitable protective measures. Warning Air Supply. Employ suitable protective measures in locations where there is contact with water droplets, oil or welding spatter, etc.. Consult with SMC when used in power plants, or if instrumentation related.. Install an air filter near this product on the supply side. Select a filtration degree of μm or less.. Compressed air containing large amounts of drainage can cause malfunction of this product and other pneumatic equipment. As a countermeasure, install an aftercooler, air dryer or Drain Catch, etc.. If large amounts of carbon dust are generated by the compressor, it can accumulate inside this product and cause malfunction. For details on the above compressed air quality, refer to SMC's "Air Preparation Systems".

Series ITV/// Specific Product Precautions Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Series ITV///9 Precautions Handling. Do not use a lubricator on the supply side of this product, as this can cause malfunction. When lubrication of terminal equipment is necessary, connect a lubricator on the output side of this equipment.. If electric power is shut off while pressure is being applied, pressure will be retained on the output side. However, this output pressure is held only temporarily and is not guaranteed. If exhausting of this pressure is desired, shut off the power after reducing the set pressure, and discharge the air using a residual pressure exhaust valve, etc.. If power to this product is cut off due to a power failure, etc. when it is in a controlled state, output pressure will be retained temporarily. Handle carefully when operating with output pressure released to the atmosphere, as air will continue to flow out.. If supply pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and a humming noise may be generated. Since the life of the product may be shortened, shut off the power supply also when supply pressure is shut off.. In this product, the output side pressure cannot be completely relieved within the range of. MPa or less. If it is desired to reduce the pressure completely to MPa, install a way valve or other device on the output side to exhaust the pressure. 6. This product is adjusted for each specification at the time of shipment from the factory. Avoid careless disassembly or removal of parts, as this can lead to malfunction. 7. The optional cable connector is a -wire type. When the monitor output (analog output or switch output) is not being used, keep it from touching the other wires as this can cause malfunction. 8. Please note that the right angle cable does not rotate and is limited to only one entry direction. 9. Take the following steps to avoid malfunction due to noise. ) Remove power supply noise during operation by installing a line filter, etc. in the AC power line. ) For avoiding the influence of noise or static electricity, install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. ) Be sure to implement protective measures against load surge for induction loads (solenoid valves, relays, etc.). Handling. Due to the large volume of the output side, a loud exhaust noise will be produced when being used for the purpose of a relief function. Therefore, install a silencer (SMC Series AN or AN) on the exhaust port (EXH port). The port sizes are Rc /8, Rc / and Rc /.. Specifications on page is in case of static environment. Pressure may fluctuate when air is consumed at the output side.. For details on the handling of this product, refer to the instruction manual which is included with the product. Design and Selection. The direct-current power supply to combine should be UL authorized power supply. () Limited voltage current circuit in accordance with UL 8. A circuit in which power is supplied by the secondary coil of a transformer that meets the following conditions. Maximum voltage (with no load): Vrms (. V peak) or less Maximum current: () 8 A or less (including when short circuited) () limited by circuit protector (such as fuse) with the following ratings. No load voltage (V peak) Max. current rating to [V]. Above to [V] Peak voltage () A circuit using max. Vrms or less (. V peak), which is powered by UL or UL8 compatible Class- power supply.. Operate these products only within the specified voltage. Using voltages beyond the specified levels could cause faults or malfunctions.. Use V as the baseline for the power supplied to the unit for output, control and input. Output power + V V Control/input power + V Output power + V V Control/input power V Back page

Series ITV/// Specific Product Precautions Connect the cable to the connector on the body with the wiring arranged as shown below. Proceed carefully, as incorrect wiring can cause damage. Further, use DC power with sufficient capacity and a low ripple. Body Pin No. Note) Current Signal Type Voltage Signal Type Power supply Input signal GND (COMMON) Monitor output Communication connector Pin No. Communication connector COMMUNICATION Power IN/OUT communication connector CC-Link SLD DB DG DA NC DeviceNet DRAIN V+ V CAN_H CAN_L PROFIBUS DP NC RxD/TxD-N NC RxD/TxD-P NC CC-Link Vcc FG GND NC CC-Link Communication connector Power supply connector PROFIBUS DP DeviceNet, RS-C Power supply connector Power supply connector Power supply connector DeviceNet PROFIBUS DP Vcc Vcc No connection NC GND GND No connection NC RS-C NC TxD RxD GND NC RS-C Vcc NC GND FG Note) The cable is also available in a right angle type. (Communication cable: straight type only) A right angle type connector is attached facing left (towards the SUP port). On communication models, the connector faces backwards (towards the EXH port). Do not attempt to rotate, as the connector does not turn. Trademark Information DeviceNet is a trademark of ODVA. Back page Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Series ITV///9 Precautions : () : () : () : () Preset Input Type Power supply Input signal GND (COMMON) Input signal Wiring Wiring diagram Vs Current signal type Vs A Vs : Power supply VDC to VDC A : Input signal to ma DC to ma DC Preset input type S S Vs : Power supply VDC to VDC S S Preset pressure Analog output: Voltage type Monitor output voltage OFF OFF P ON OFF P Switch output: NPN type OFF ON P ON ON P Monitor output wiring diagram Voltage signal type Vs Vin Vs : Power supply VDC to VDC Vin: Input signal to VDC to VDC One of the preset pressures P through P is selected by the ON/OFF combination of S and S. Load Monitor output voltage For safety reasons, it is recommended that one of the preset pressures be set to MPa. Preset pressures are set based on the minimum unit for output display. MPa. kgf/cm. bar. psi. Note that this is psi for psi types. Switch output: PNP type Load When 8 ma DC or more is applied, detecting device for overcurrentstarts activating and then emits an error signal. (Error number ) kpa Analog output: Current type (Sink type)

Series ITV/// Specific Product Precautions Set Pressure Range The set pressure range, by unit of standard measured pressure, is shown in the table below. Set pressure range, by unit of standard measured pressure Unit Set pressure range ITV ITV ITV ITV9 MPa. to.. to.. to.9 kgf/cm bar.. to to.. to to.. to to 9 9 psi kpa.7 to to.7 to 7 to.7 to to 9. to 8 CE Marking When using the power supply cable for the CE compliant product (including Made to Order), mount the ferrite core on the cable according to the following Ferrite core necessity. Series ITV Model ITV- -Q Ferrite core necessity Unnecessary Series ITV// Model ITV - -Q ITV -CC -Q ITV -DN -Q ITV -PR -Q ITV -RC -Q Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Ferrite core necessity Necessary Unnecessary Necessary (Ferrite core is supplied as an accessory for the body. Necessary (Ferrite core is supplied as an accessory for the body. Recommended power supply cable M8-DSXMG (Straight type) ELWIKA-KV8 PVC M (Right angle type) Recommended power supply cable P98- (Straight type) (With ferrite core) P98- (Right angle type) (With ferrite core) P98-- (Straight type) P98-- (Right angle type) P98-- (Straight type) P98-- (Right angle type) P98-- (Straight type) P98-- (Right angle type) Note) Recommended power supply cable length is m. (ELWIKA-KV8 PVC M is m.) If any other length is desired, please consult with SMC. Series ITV///9 Precautions Back page 6

Series ITV/// Specific Product Precautions 6. Connect the vacuum pump to the port, which is labeled VAC.. Pressure adjustment changes from atmospheric pressure to vacuum pressure when the input signal is increased, and from vacuum pressure to atmospheric pressure when the input signal is decreased.. When adjusting the vacuum pressure, be careful not to block the atmospheric pressure inlet port labeled ATM.. Since this product is designed exclusively for use with negative pressure, be careful not to apply positive pressure in error.. In cases where the vacuum pump being used has a relatively small capacity, or the piping has a small inside diameter, etc., large variations in the set pressure (the range of pressure variation when changing from no flow to flow state) may appear. In this situation, the vacuum pump or the piping, etc. should be changed. In cases where it is not practical to change the vacuum pump, install a capacity tank (volume depending on the operating conditions) on the VAC side. 6. The vacuum pressure response time after a change in the input signal is influenced by the internal volume on the setting side (including piping). Since the capacity of the vacuum pump also influences the response time, give careful consideration to these points before operation. 7. If the electric power is shut off when in a control state, the pressure on the setting side will go into a holding condition. However, this setting side pressure will be held only temporarily and is not guaranteed. In addition, when atmospheric pressure is desired, shut off the power after reducing the set pressure, and then introduce atmospheric pressure by using a vacuum release valve, etc. 8. If the power for this product is cut off by a power failure, etc. when it is in a controlled state, the setting side pressure will be held temporarily. Further, if operated without sealing the setting side so that atmospheric air is sucked in, handle with care as air will continue to be sucked in. Back page 7 Be sure to read before handling. Refer to back page for Safety Instructions, Handling Precautions for SMC Products (M-E-) for Common Precautions. Series ITV9 /9 Precautions Handling 9. If the VAC side pressure to this product is interrupted while the power is still on, the internal solenoid valve will continue to operate and may cause a humming noise. Since this may shorten the life of the product, be sure to shut off the power when the VAC side pressure is shut off.. The setting side pressure cannot be completely released from this product in the range below. kpa. In cases where the pressure needs to be reduced completely to kpa, install a port valve, etc. on the setting side to discharge the residual pressure.. This product is adjusted for each specification at the factory before shipment. Avoid careless disassembly or removal of parts, as this can cause failure.. The optional cable connector is a -wire type. When the monitor output (analog output, switch output) is not being used, keep it from touching the other wires, as this can cause malfunction.. Use caution that the right angle cable does not rotate and is limited to only one entry direction.. Take the following steps to avoid malfunction due to noise. ) Eliminate power supply noise during operation by installing a line filter, etc. in the AC power line. ) For avoiding the influence of noise or static electricity, install this product and its wiring as far as possible from strong electric fields such as those of motors and power lines, etc. ) Make sure to take protective measures against load surge for an induction load (solenoid valves, relays, etc.).. Refer to the instruction manual included with the product for details on its handling.

Akihabara UDX F, --, Sotokanda, Chiyoda-ku, Tokyo -, JAPAN Phone: -7-89 Fax: -98-6 URL http://www.smcworld.com SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Edition D Addition of Series ITV. Number of pages from 6 to. HX Edition E Addition of Series ITV/9. Addition of Series ITV9. Addition of Fieldbus-compatible specifications CC-Link, DeviceNet and PROFIBUS DP. Addition of RS-C serial communication specification. Addition of CE [option] and UL. Number of pages from to. NS Edition F Change of dimensions of Series ITV///9. Change of enclosure for Series ITV9 to conform to IP6. OZ D-DN Revision history st printing HX printing OZ SZ Printed in Japan.