Industrial PFC UPS System

Similar documents
Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Technical Data Sheets

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Data Sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheets

POWER kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Data Sheets

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

MGE TM Galaxy TM 7000 GFC

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

EFFEKTA Power Supplies

Technical Data Sheets

Technical Data Sheets

PowerValue 11/31 T kva

MGE TM Galaxy TM 7000

Three Phase UPS Systems Range: 10 to 500kVA

Technical Data Sheets

Liebert. FP 50Z kva

Technical data sheets

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MKN-DSP SERIES - THREE PHASE

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Master Plus kva

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

1.1 GENERAL CHARACTERISTICS

UPS Multi Sentry 10-20kVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Data Sheets

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Green Power 2.0 MASTERYS GP

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

Industrial Chargers and

PowerWave 33, kw

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical Specification SENTINEL PRO

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

POWERTRONIX QUASAR 5-40 KVA

60 to 160 kva.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Est FlexiPower Mini UPS FPX Mini kVA

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

ConceptpowerTM Modular kVA

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

PowerScale kva Technical Specifications

Master DIALOG INDUSTRY RANGE

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

MASTERYS IP+ 10 to 80 kva

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Onfiniti. 1 Phase UPS

PowerScale TECHNICAL SPECIFICATIONS

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

TECHNICAL SPECIFICATIONS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Three Phase UPS Systems

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

TLE Series UPS 400/500 kw With eboost Technology

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

UPS Multi Power 1-28 x 42 kw up to 1MW

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

AME. Rectifier - Battery charger. Industrial applications: Key features:

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

TLE Series UPS 160/200/225/250 kw with eboost Technology

Features and Benefits

HAIRF UPS. X5 Series KVA

Transcription:

Based on Statron s leading A.T.I.S. (Advanced Technology Industrial System) platform, the S3000 range is a true-industrial UPS system using the latest Power Factor Corrected (PFC) IGBT rectifier technology. With this technology, harmonic distortion at the input to the UPS is minimized, while UPS efficiency is greatly increased, saving energy and cost. It is specifically designed and developed for the harshest environmental conditions meeting the most stringent requirements in high-end industrial applications. The S3000 design complies to the most stringent industrial classification (VFI-SS- 111 in accordance with IEC/EN 62040-3). Industrial PFC UPS System S3100 /S3300 5 200 kva Key benefits and features Reliability Design A.T.I.S. Technology Performance Efficiency Battery Management Communication Environment fully monitored online double conversion UPS rugged, reliable, compact industrial design latest µp controlled IGBT technology market leading overall UPS performance greatly increased efficiency even at partial load intelligent system with mains back-feed discharge top class communication platform reduced energy and material impact www.statron.com

S3000 Applications Applications The S3000 UPS range meets the most stringent requirements and specifications in high -end industrial applications: Oil and Gas (Petrochemicals, Offshore, FPSO, Onshore, Pipelines etc.). Energy and Electricity (Power Generation, Transmission, Distribution). Water (Desalination, Treatment, Pipeline). Instrumentation and Process Control (Chemical, Mining, Steel, Pulp and Paper). All high end industrial applications. Configurations Depending on the load supply concept, different configurations are supported: Single configuration. Parallel redundant configuration (up to 8 units, progressive start-up). Parallel redundant configuration with monitored coupling switch. Dual configuration also with external synchronization source. Common or individual batteries. -Q001 UPS 1 Incoming 1 -Q040 Incoming 2 -Q001 -Q040 UPS 2 Bypass -Q005 Reliability UPS solutions engineered by Statron have been protecting industrial installations for more than three decades: Auto Test Bypass -Q050 Auto Test Bypass -Q050 Well proven system platform. Higher MTBF and low MTTR. High quality rugged components. 30 year design life. Complying to all relevant ISO and IEC/EN standards. -Q501 -Q502 -Q071 -Q073 -Q072 Synch NO Dual Feed AC Loads Dual Feed AC Loads Picture: Typical Oil and Gas configuration Dual with individual batteries and monitored coupling switch.

S3000 Features and Benefits A.T.I.S. Technology Design High end industrial applications require high level protection and flexible customized design. The S3000 range offers: Market leading fault clearing and short circuit performance. Excellent dynamic behaviour. Unlimited load power factor (0.0 lag to 0.0 lead). Robust mechanical compact design and construction. Segregated Incomer/Bypass panel housing all switching devices and electrical connection points Electrically and physically integrated galvanic isolation. Designed to withstand harsh environmental conditions (up to IP54). Complying to the most stringent industrial classification (VFI-SS-111 in accordance with IEC/EN 62040-3). Redundant internal power supply. Intelligent cooling management by means of redundant and individually monitored speed controlled fans. External synchronization possibility / designed for (diesel-) generator operation. The exceptional characteristic of the S3000 UPS range is the result of state-of-the-art technology of the A.T.I.S. platform: PFC rectifier dramatically reduces input harmonics (<5% THDi), minimizing distortion to upstream equipment (no oversizing of upstream generator required). Up to 95% efficiency using state-of-the-art semiconductor technology (IGBT, Trench technology). Fully digital control (two 16 bit micro controllers). CAN-bus internal communication. Environment Statron is committed to environmental sustainability. Our dedication drives the development and success of our products. The outstanding features include: Energy recovery by battery discharge into the mains. Optimised efficiency even at partial load. Class leading battery management system to extend battery life. Minimal distortion to upstream equipment, no oversizing required. ISO 14001 certified. Operation and Control The front panel of the S3000 includes a comprehensive, customizable human-machine interface. It enables the complete control and monitoring of the UPS with multi-method visualization: Easy and intuitive operation and control. Programmable alarms and indications. 4-line, 80 digit LCD display. Programmable color-coded LED s. Event recorder for 1050 events. Optional TFT touch screen panel.

S3000 Features and Benefits Interface and Communication State-of-the-art communication software and facilities support the monitoring and control of the S3000 UPS: RS232/RS485 serial interface with MODBUS protocol. PROFIBUS interface. IEC 61850 gateway. Network interface (TCP/IP). Remote display. Programmable relay cards. Digital inputs (for EPO, generator operation, etc.). Programmable analogue inputs (battery temperature, etc.). Programmable analogue outputs (0/4 20 ma). Battery Management Battery monitoring and management is a key factor for a reliable and durable power back-up of your system. The Statron S3000 UPS has class leading built-in features: Integrated constant current battery discharge test facility (by means of sinusoidal mains backfeed). Built-in battery monitoring facility / programmed discharge curve. Constantly updated battery capacity and battery back-up time. Compatible with all battery types / wide DC range. Three individual programmable battery charge voltages. Two individual battery charge current limitation levels. Service, Maintenance and Trouble Shooting Statron products are renowned for their serviceability: Built-in DSO function. Integrated fault diagnostic features with printer port. Front access to key components (fans, capacitors, etc.). Hot swappable fan. No load bank required for battery testing (the integrated constant current battery discharge test facility enables a battery test by means of sinusoidal mains backfeed). The reliability of your installed power solution is supported by a Global Service Team renowned for its short response time and trouble shooting efficiency.

S3000 - Technical Specification S3100 single phase S3100-xx S3100-xx S3100-xx S3100-xx S3100-80 S3100-100 S3100-120 S3100-160 S3100-200 Power Rating (p.f. 0.8 ind.) 05/10 kva 15/20 kva 30/40 kva 50/60 kva 80 kva 100 kva 120 kva 160 kva 200 kva UPS Input Rectifier AC input voltage Rectifier input power factor Rectifier input frequency Bypass AC input voltage Bypass input frequency DC / Battery Circuit Rectifier type Nominal DC voltage DC voltage range Ripple voltage Charging characteristic to DIN 41773 Float/Boost/Initial charge voltage Float/Boost battery charge current limitation UPS Output Nominal AC output voltage (static 0 100% load) (dynamic 0-100% - 0 load) Regulation time (±1%) Inverter overload 1 min Inverter overload 10 min Inverter overload, continuous Inverter short circuit current (max 3s) Bypass overload 10 min Bypass overload 100 ms Frequency Frequency tolerance free running Frequency synchronization range Allowable load power factor Voltage wave form Distortion factor linear load Distortion factor non linear load (acc. IEC/EN 62040-3) Allowable crest factor General Data Efficiency (AC-AC) Noise level Cooling Operating temperature Storage temperature Maximum altitude without derating Allowable relative humidity Protection degree Color Safety EMC Performance Conformity Quality/Environment Dimensions (IP20, basic configuration) Height (mm) Width (mm) (with Bypass Transformer) 1200 (1200) 1200 (1200) 1200 (1400) 2200 (2400) 2400 (2600) 2400 (2600) 3200 (3400) 2800 (3000) 2800 (3000) Depth (mm) 3x400 V ±15% (3x380 V, 3x415 V, others on request) >0.99 (>0.97 at 25% load) 1x230 V ±10% (220 V, 240 V) / 3x400 V ±10% (3x380 V, 3x415 V, others on request) IGBT (PFC) Power Factor Corrected (Thyristor Rectifier optional) 110 V / 125 V / 220 V / 400 V 110/125 V: 89-140 V, 220 V: 185-280 V, 400 V: 317-445 V I/U individually programmable individually programmable (up to I5) 230 V (220 V, 240 V, other on request) ±1% <5% (without battery) <10 ms 125% 105% 300% 1000% 50 Hz / 60 Hz ±0.01% ±5% adjustable 0.0 lag 0.0 lead sinusoidal <5% 3 90% 94% depending on model and DC voltage 63 db(a) 70 db(a) forced ventilation (redundant, speed controlled and monitored) 10 to +40 C (55 C optional) 30 to +80 C 1000 m <95% (non condensing) IEC/EN 60529 IP20 (up to IP54) RAL 7035 (other color optional) IEC/EN 62040-1 IEC/EN 62040-2 (class C3, C2 optional) IEC/EN 62040-3 (VFI-SS-111) CE ISO 9001:2008 / ISO 14001:2004 2000 800 (1000) Further data available on request 2016 Statron AG, data subject to change without notice Statron AG Industrie Nord CH-5506 Mägenwil Switzerland Phone +41 62 887 4 887 Fax... 888 E-mail: statron@statron.ch www.statron.com

S3000 - Technical Specification S3300 three phase S3300-xx S3300-xx S3300-xx S3300-xx S3300-80 S3300-100 S3300-120 S3300-160 S3300-200 Power Rating (p.f. 0.8 ind.) 05/10 kva 15/20 kva 30/40 kva 50/60 kva 80 kva 100 kva 120 kva 160 kva 200 kva UPS Input Rectifier AC input voltage Rectifier input power factor Rectifier input frequency Bypass AC input voltage Bypass input frequency DC / Battery Circuit Rectifier type Nominal DC voltage DC voltage range Ripple voltage Charging characteristic to DIN 41773 Float/Boost/Initial charge voltage Float/Boost battery charge current limitation UPS Output Nominal AC output voltage (static 0 100% load) (dynamic 0-100% - 0 load) Regulation time (±1%) Inverter overload 1 min Inverter overload 10 min Inverter overload, continuous Inverter short circuit current (max 3s) Bypass overload 10 min Bypass overload 100 ms Frequency Frequency tolerance free running Frequency synchronization range Allowable load power factor Voltage wave form Distortion factor linear load Distortion factor non linear load (acc. IEC/EN 62040-3) Allowable crest factor General Data Efficiency (AC-AC) Noise level Cooling Operating temperature Storage temperature Maximum altitude without derating Allowable relative humidity Protection degree Color Safety EMC Performance Conformity Quality/Environment Dimensions (IP20, basic configuration) Height (mm) Width (mm) (with Bypass Transformer) 1200 (1200) 1200 (1200) 1200 (1400) 2200 (2400) 2400 (2600) 2400 (2600) 3200 (3400) 2800 (3000) 2800 (3000) Depth (mm) 3x400 V ±15% (3x380 V, 3x415 V, others on request) >0.99 (>0.97 at 25% load) 3x400 V ±10% (3x380 V, 3x415 V, others on request) IGBT (PFC) Power Factor Corrected (Thyristor Rectifier optional) 110 V / 125 V / 220 V / 400 V 110/125 V: 89-140 V, 220 V: 185-280 V, 400 V: 317-445 V I/U individually programmable individually programmable (up to I5) 3x400 V (3x208 V, 3x380 V, 3x415 V, others on request) ±1% <5% (without battery) <10 ms 125% 105% 300% 1000% 50 Hz / 60 Hz ±0.01% ±5% adjustable 0.0 lag 0.0 lead sinusoidal <5% 3 90% 94% depending on model and DC voltage 63 db(a) 70 db(a) forced ventilation (redundant, speed controlled and monitored) 10 to +40 C (55 C optional) 30 to +80 C 1000 m <95% (non condensing) IEC/EN 60529 IP20 (up to IP54) RAL 7035 (other color optional) IEC/EN 62040-1 IEC/EN 62040-2 (class C3, C2 optional) IEC/EN 62040-3 (VFI-SS-111) CE ISO 9001:2008 / ISO 14001:2004 2000 800 (1000) Further data available on request 2016 Statron AG, data subject to change without notice Statron AG Industrie Nord CH-5506 Mägenwil Switzerland Phone +41 62 887 4 887 Fax... 888 E-mail: statron@statron.ch www.statron.com