Pattern Air Control Kit (PACK)

Similar documents
Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Manifold-Mounted to Flange-Mounted Solenoid Valve Conversion

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a threaded filter.

11-1 Electrical System NOTE: Table of Contents Electrical System

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with C-style cordsets.

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with M-style cordsets.

0 900 psi Pressure-Reducing Diaphragm Regulator

8. Illustrated Parts Lists

8. Illustrated Parts Lists

Air Spray Proportioning Valve

Solenoid Valve Installation Kit

Mobile Powder Spray System Dolly with Hopper

SP30 10:1 Piston Pump

AN-8 Plus Air Spray Gun Solvent-Based to Waterborne Conversion Kit

Rhino SD2/XD2 Electric Container Level Sensors for 125-mm Frames

Miniature Soft Seat Fluid Pressure Regulator

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

Standard and Conical AN Series Air Spray Nozzles

Auto-Flo Air-Assist Automatic Dispensing Valve

8. Illustrated Parts Lists

Pro-Swirl Manifold Air Heater

Nordson Airless Nozzle Tester

Module. Section 9. NOTE: This section applies to applicators with CC200 modules B Issued 6/01. Manual 42-CF200-CM-01

Upgrading the Sure Coat Modular Gun Control System

Mobile Powder Spray System Dolly with Hopper for Cable-Fed Systems

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

EP-2 Si Three-Piston Pump

Installation Instructions for Series 3100V Low Level Indicator

Inverted High Pressure Fluid Filters

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Prodigy HDLV Generation II Pump Panel

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with MB200 modules.

DPS280 / DVS280 Series

TCU Flushing Manifold and RTD Installation

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Electric Vibratory Box Feeder Retrofit Kit

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

LTX RF LEVEL SENSOR. Instruction Manual

OPERATOR S CARD. Select Series H-440 Hot Melt Dispensing Guns. Safety. Description. Nordson Corporation P/N D

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Spray Pressure Control Manifold

Installing the Integral Platen Blow Off Valve

Spray Pressure Control Manifold

Sure Coat 90 Degree Spray Extension

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Encore HD Powder Spray System with Prodigy Pump Cabinet

1100 Series Piston Type Differential Pressure Gauges

Prodigy Mobile Box Unloader System

Prodigy HDLV Pump Manifold and Circuit Board

Prodigy HDLV Manual System Installation Instructions

Paint/Solvent/Dump Valve and Flow-Through Valve

VL400 Melters. Safety. Introduction. Nordson Corporation OPERATOR S CARD P/N A

EP-2 Three-Piston Pump


Inverted Dual High-Pressure Fluid Filter Assemblies

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

SPRAY RUN-UP CONTROL KIT ( 4-20 ma Version)

Tracer VMA with AutoReg

Optional Nozzles for Versa-Spray and Versa-Spray II Guns

Blow Off Valve Retrofit Kit

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Installation, Operation and Maintenance Manual

High Flow and 100 PLUS FB Powder Pumps

Tracer VM with User Interface

Installing an H-200 Integral Right-Angle Module

0-800 psi Carbide Seat Fluid Pressure Regulator

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

55-Gallon Powder Drum Truck

Rhino SD/XD Depressurization Modules for Electric Changeover Controls

Sure Coat Modular Gun Control System Part D: Gun Purge Module. Customer Product Manual Part B

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Econo-Coat Manual Powder Spray Gun

SS3 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

Sentronic D 608 Series and 609 Series

One-Gun Add-On Kit For Smart-Coat Controllers

Sure-Max Powder Transfer System

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

0-500 PSI Soft Seat Fluid Pressure Regulator

Description. Repair. Rhinor XD2 Type-H Low Level Drum Proximity Sensor. Replacing the Proximity Sensor

Vantage Individual Powder Spray Gun Controller

Soft Seat Fluid Pressure Regulator

OBSOLETE. RA-16 Rotary Atomizer Upgrade Kit. Instruction Sheet P/N A. 1. Introduction. 2. Disassembly

Back Pressure Regulator

PMV P36C AND P41C POSITIONERS ACTUATORS

Tel: SEMITORR GROUP INC.

Type A-10 General Purpose Pressure Transmitters

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

Parts. Part B, Section 5. This section covers the following unit configurations Model 3500 Voltage 1. 2 Piston (E,) Issued 11/00

Series 3900/M Pump Retrofit Kit

QVT MULTIVARIABLE TRANSMITTER

Transcription:

Instruction Sheet P/N 044445B0 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment can result in injury, including death, to themselves and others, and damage to the equipment. Introduction The pattern air control kit (PACK) assembly automatically increases or decreases the pattern air pressure for a spray application based on the speed of the production line by converting an electronic line-speed reference signal from a parent machine to a corresponding output air pressure. Two PACKs are available: one for a 0 0 VDC signal and one for a 4 0 ma signal. The kits may be used with either pressure-fed or metering applicators. The PACK assembly is composed of three filters and a micro-processorcontrolled electro-pneumatic regulator. The filters remove oil, water, and particulates from the pattern air before it supplied to the applicator. Figure shows the key parts of the PACK assembly. 69000008 Figure PACK assembly

Key Parts /4 NPT INLET 4 /4 NPT OUTLET 8 5 7 Figure Key parts of the PACK assembly. Air inlet ( / 4 NPT). Mounting bracket. Reference signal cable 6 4. Regulator 5. Air outlet ( / 4 NPT) 6. Water filter 7. Oil filter 8. Particulate filter

Installation. See Figure. Mount the PACK assembly using the mounting bracket. For the dimensions of the assembly, refer to Dimensions under Technical Data at the end of this instruction sheet. WARNING: Improper wiring will damage the internal circuitry. Allow only qualifed personnel to connect wiring.. Connect the reference signal cable to the regulator and to the parent machine. Refer to Wiring Diagrams under Technical Data at the end of this instruction sheet.. Connect the pattern air supply line to the air inlet and outlet on the assembly. See Figure for the location of the outlets. 4. Continue to the next procedure to program the regulator. 56 mm (.0 in.) 5 mm (0. in.) Figure 9 mm (0.5 in.) Mounting bracket dimensions 690000

4 Regulator Setup This section includes the following procedures: Unlocking/Locking the Keys Programming Minimum and Maximum Pressures Use these procedures to program the regulator for your application. Figure 4 shows the location of the regulator keys and display. 4 6900000 Figure 4 Location of the regulator keys and display. UNLOCK (down arrow) key. SET key. LOCK (up arrow key) 4. Display

5 Unlocking/Locking the Keys To prevent unauthorized changes, the regulator has a key lock feature that allows you to disable the programming keys. By default, the keys are locked when the power is turned on. The keys must be unlocked to change any settings. The display will show Loc if a key is pressed while the keys are locked. See Figure 4 for the location of the keys on the regulator. Locked To Unlock. Press and hold the UNLOCK (down arrow) key for seconds or longer. The display will blink LOC.. Press the SET key to unlock the keys, or press the LOCK (up arrow) key to cancel. Unlocked To Lock. Press and hold the LOCK (up arrow) key for seconds or longer. The display will blink UNL.. Press the SET key to lock the keys, or press the UNLOCK (down arrow) key to cancel.

6 Programming Minimum and Maximum Pressures For the PACK assembly to automatically increase or decrease the pattern air pressure based on the line speed, you must program the regulator to set the minimum and maximum air pressure values that will work for your application. Set the minimum pressure (zero point) at 0% of the input (line-speed reference) signal and set the maximum pressure (span) at 00% of the input signal. The minimum pressure can be set as low as 0% and as high as 50% of the full span. The maximum pressure can be set as low as 0% and as high as 00% of the full span. For example, the regulator could be set to output.4 bar (5 psi) at 0% input signal and.0 bar (4 psi) at 00% input signal. There must be at least 0.6 bar (8 psi) separation. Similarly, the regulator could be set to output 0 bar (0 psi) at 0% input signal and 0.6 bar (8 psi) at 00% input signal. Figure 5 shows how the pressure changes based on the input signal. Minimum pressure range Maximum pressure range Pressure output (%) 00% 50 0 4 0 ma 0 5 0 VDC Input signal Pressure output (%) 00% 50 0 0 4 0 ma 0 5 0 VDC Input signal 6900400 Figure 5 Pressure changes based on line-speed reference signal

7 Programming Minimum and Maximum Pressures (contd) CAUTION: Risk of equipment damage or personal injury. When you change the minimum and maximum pressure values, the new values take effect as soon as the SET key is pressed. See Figure 4 for the location of the keys on the regulator. To Unlock the Keys. Press and hold the UNLOCK (down arrow) key for seconds or longer. The display will blink Loc.. Press the SET key to unlock the keys.. Press the SET key to continue to the next step. To Set the Minimum Pressure (F_). Press the up and down arrow keys until the display shows the desired minimum pressure.. Press and release the SET key to continue to the next step. To Set the Maximum Pressure (F_). Press the up and down arrow keys until the display shows the desired maximum pressure.. Press and release the SET key to continue to the next step.

8 Maintenance Replace all filter elements as follows: Whenever there is a drop in pressure or air flow Every 6 months, as appropriate for your operation Troubleshooting Use the following table to troubleshoot the PACK assembly based on the error code shown on the regulator display. See Figure 4 for the location of the display on the regulator. Error Code Problem Corrective Action Er Line-speed reference signal exceeds the signal range Check your programmed settings for minimum and maximum pressure. Refer to Programming Minimum and Maximum Pressures. Er EPROM read/write error Reset the regulator (see Note). Er Memory read/write error Reset the regulator (see Note). Er Internal solenoid valve malfunction Replace the regulator. Er0 Other Contact your Nordson representative. NOTE: To reset the regulator, simultaneously press and hold the up and down arrow keys for seconds or longer.

9 Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use these five-column parts lists, and the accompanying illustrations, to describe and locate parts correctly. The following chart provides guidance for reading the parts lists. The number in the Item column corresponds to the circled item number in the parts list illustration. A dash in this column indicates that the item is an assembly. The number in the Part column is the Nordson part number you can use to order the part. A series of dashes indicates that the part is not saleable. In this case, you must order either the assembly in which the part is used or a service kit that includes the part. The Description column describes the part and sometimes includes dimensions or specifications. The Note column contains letters that refer to notes at the bottom of the parts list. These notes provide important information about the part. The Quantity column tells you how many of the part is used to manufacture the assembly shown in the parts list illustration. A dash or AR in this column indicates that the amount of the item required in the assembly is not quantifiable. Item Part Description Quantity Note 0000000 Assembly A 000000 Part of assembly A A - - - - - - Part of item 0000000 Part of item AR NS 000000 Part of item NOTE A: Important information about item AR: As Required NS: Not Shown

0 Pattern Air Control Kit Parts See Figure 6. Item Part Description Quantity Note 0658 Kit, pattern air control, 4 0 ma, 0.5 bar 0444 Regulator, air control, 4 0 ma, 0.5 bar (present in 0658 kit) 0569 Kit, pattern air control, 4 0 ma, 0 bar 05694 Regulator, air control, I/P, 4 0 ma, 0 bar (present in 0569 kit) 0650 Kit, pattern air control, 0 0 VDC, 0.5 bar 059047 Regulator, air control, 0 0 VDC, 0.5 bar (present in 0650 kit) 0569 Kit, pattern air control, 0 0 VDC, 0 bar 05695 Regulator, air control, 0 0 VDC, 0 bar (present in 0569 kit) 0440 Filter element, particulate 04405 Filter element, coalescing (oil) 4 04406 Filter element, water separator NS 04407 O-ring, filter bowl NS: Not Shown /4 NPT INLET /4 NPT OUTLET 4 Figure 6 PACK assembly parts

Cable Part Numbers See Figure 7. Item Part Description Quantity Note 059045 Cable, regulator, air control, 0 m AR 05904 Cable, regulator, air control, 0 m AR 05899 Cable, regulator, air control, 0 m AR 059046 Cable, regulator, air control, 0 m, bare end AR 055 Connector, 4-conductor, air control AR A NOTE A: For best results use a four-conductor, 4 AWG, shielded conductor cable (Belden cable no. 954 or equivalent) with this connector. AR: As Required PIN WIRE PIN WIRE RED RED WHITE BLACK 4 BLACK WHITE PIN WIRE RED BLACK WHITE PIN WIRE RED BLACK WHITE Figure 7 Cables for PACK kits

Technical Data Specifications Item Supply Pressure Output Pressure Maximum Flow Specification [set pressure + bar (4.5 psi)] to 0 bar (45 psi) 0.05 bar (0.7 4.7 psi), or 0.05.5 bar (0.7 5.5 psi) 5.5 scfm Supply Voltage 4 VDC ±0% Input Signal Linearity Hysteresis Repeatability 0 0 VDC or 4 0 ma DC ±% full span 0.5% full span ±0.5% full span Dimensions 97 mm (.70 in.) 66 mm (.59 in.) 70 mm (0.6 in.) 77 mm (6.96 in.) 690000

Figure 8 PACK assembly dimensions Wiring Diagrams 4 0 ma PACK Assembly Brown Vs Blue White A Black Supply voltage = 4 VDC Figure 9 Wiring diagram for 4 0 ma signal 0 0 VDC PACK Assembly Brown Vs Blue White Vin Black Supply voltage = 4 VDC Figure 0 Wiring diagram for 0 0 VDC signal

4 Reference Signal Cables PIN WIRE PIN WIRE RED RED WHITE BLACK 4 BLACK WHITE PIN WIRE RED BLACK WHITE Figure Reference signal cable wiring diagrams Reference Signal Cable Pin Positions Table Reference Signal Cable Pin Positions Pin Wire Color Description Brown Supply voltage White Input signal Blue Ground 4 Black Monitor output 690000 Figure Reference signal cable pin positions Issued /08 Original copyright date 00. Nordson and the Nordson logo are registered trademarks of Nordson Corporation.