Series P74 Differential Pressure Controls, without time delay

Similar documents
I ntroduction. N ote. Series P74 Differential Pressure Controls, without time delay. Feature and Benefits

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

P77 Series. Single Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications. Product Bulletin

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

VA-707x. Thermal Valve Actuators. Product Bulletin. Low and line voltage models available

P70, P72 and P170 Series Controls for High Pressure Applications

P70, P72, and P170 Series Controls for High Pressure Applications

Suitable to Johnson Controls and almost all of terminal unit valve on the market

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

TS Temperature Sensor and Transducers. Product Bulletin. Wide range of mounting types and signal outputs

Series P20 Pressure Controls for Refrigeration, Air-conditioning and Heat-pump Applications. Feature and Benefits. P20 Pressure Control

Series P255MM/ML Single/Dual Pressure Input Condenser Fan Speed Controllers For Three Phase Motors (incl. built-in RFI suppression filter)

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

P70, P72, and P170 Controls for Low Pressure Applications

F261 Series Fluid Flow Switches

VA-715x Electric Valve Actuator

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

V46 Series Pressure-Actuated Water-Regulating Valves

V6W0000. Six Ways Ball Valves for Terminal Units. Product Bulletin. No cross-flow between floating and cooling circuits.

VPA Series and VAP Actuator

VG9000 Flanged Valves

AV-8020 Series Floating Control Actuated Valve

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

A11 Series Low Temperature Cutout Control

VA9203-AGx / VA9203-Bxx / VA9203-GGx

TM-11x1 Series Room Temperature Module

M Ball Valve Linkage Kit

P445 Series Electronic Lube Oil Control

System 350 P352AB Electronic Pressure Control Series

VA-7450 Series. Electric Valve Actuators

VG6000. Globe Valves Series for Terminal Units. Product Bulletin

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

VA-7150 Electric Valve Actuator. Features and Benefits. G 500N force output in a compact unit G Magnetic clutch. G Unique Yoke Design

M9300 Series Switch Kits

VG7000 Female Threaded Cast Bronze Valve Series with Electric Actuators

V5000. Globe Valves Series for Terminal Units. Product Bulletin

Series Y63, Y64, Y65, Y66, and Y69 Transformers

TE-6300 Series Temperature Sensors

CSD Series Current Devices Split Core

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

P20, P21 Series Air Conditioning Limit Controls

RA-2000 Airflow Measuring System

A419ABG-3C Electronic Temperature Control

TE-6300 Series Temperature Sensors

Introduction. Series A99 Temperature Sensors. Features and Benefits

VA-715x Electric Valve Actuator

VSD Series II Variable Speed Micro Drives

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

Series A99 Temperature Sensors. Features and Benefits. The A99 temperature sensor line includes various models, such as:

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

AD-1251 Probe with Differential Pressure Transducer

VA-8020 Floating Valve Actuator

M x Series Valve Linkage Kits

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

RD-2000 Round Control Dampers

VG7000 Series Bronze Control Valves

Pressure Control Type KPU

F61 Series Standard Flow Switches

VG8000N Series PN16, DN15 - DN150

M9220-xxx-3 Electric Spring Return Actuators

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

Replacement Timing Relays for P28 and P29 Lube Oil Controls

JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

AD-1250 Airflow Measuring Station

M9000-3xx Series Weather Shield Enclosures

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

I ntroduction. VA-7450 Electronic Terminal Unit Valve Actuator. Features and Benefits

A25 Series Warm Air Control with Manual Reset

A70, A72 Series Temperature Controls for Refrigeration and Heating

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

M9300 Series Electric Non-Spring Return Actuators

Product Catalogue. Electromechanical controllers REL

PC-125x Counter-Balanced Backdraft Damper

G72x Series Direct Spark Ignition Controls

M Valve Actuator Weather Shield Kit

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

M9203-xxx-2(Z) Series Electric Spring Return Actuators

BD-1600 Balancing/Zone Control Damper

PP1 Series Piping Packages for VG1000 Series Ball Valves

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Flare Valves 1/2 inch 2-Way and 3-Way

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

M9109 Series Electric Non-spring Return Actuators

SD-1250 and SD-1600 Series Smoke Dampers

Cartridge pressure switch Type CB

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

VG6000 Series Forged Brass Valves

P78 Series Controls for Dual Pressure and Hazardous Location Applications

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

Transcription:

PB_P74_11 2010 Series P74 Differential Pressure Controls, without time delay These controls are designed to sense pressure differences between two points and may be used as operating or limit controls. Typical applications are to detect flow across a chiller or water cooled condenser, to detect flow in a heating system and sensing lube oil pressure differential on refrigeration compressors. P74 Differential Pressure Control Heavy duty pressure elements Withstand high overrun pressure These controls may be used in combination with series P28 lube oil protection control on two compressor, single motor units. Reduces the lube oil system cost.

2 PB_P74_11 2010 Dimensions in mm A. Reset button B. Mounting hole, 5 mm dia. C. Mounting slot D. 10-32 UNF2B

PB_P74_11 2010 3 Description The P74 series of differential pressure switches incorporate two opposing pressure elements and an adjustable range setpoint spring with a calibrated scale. The control switches at the indicated setpoint on an increase in differential pressure and switches back to the normal position when the different pressure decreases to the setpoint less the mechanical switching differential. These controls are designed for use only as operating controls. Where an operating control failure would result in personal injury or loss of property it is the responsibility of the installer to add devices or systems that protect against, or warn of, control failure. Adjustment The setpoint can be adjusted by the notched cam A located on the top of the control. The switching differential can be adjusted by turning a hexagonal nut on the differential adjusting screw located inside the control cover (adjustable differential models only). P P74, Cover removed (P) Setpoint adjusting cam Contact function Fig. 1a. Type P74EA and P74FA 1-2 closes on increase of differential pressure 1-3 opens simultaneously Fig. 1b. Type P74DA Contacts close on increase of differential pressure Repair and replacement Power elements may be replaced in the field. Other repairs are not possible. In case of an improperly functioning control, please check with your nearest supplier. When contacting the supplier for a replacement you should state the type/model number of the control. This number can be found on the data plate or cover label.

4 PB_P74_11 2010 Type number selection table Order number P74DA-9300 P74DA-9600 P74EA-9300 P74EA-9600 P74EA-9700 P74FA-9700 P74FA-9701 Range P (bar) 0.6/4.8 0.6/4.8 0.6/4.8 0.6/4.8 0.6/4.8 0/1 2.0/8.0 Switching differential (bar) 0.7/2 adj. 0.7/2 adj. 0.3 fix. 0.3 fix. 0.3 fix. 0.1 fix. 0.7 fix. Medium Ammonia Ammonia Noncorrosivcorrosivcorrosivcorrosive Water or Noncorrosivcorrosive or Refrigerant Refrigerant Refrigerant Refrigerant Refrigerant Refrigerant Pressure connector (style) 5 13 5 13 15 15 15 Electrical rating 15(10) A 15(10) A 15(8) A 15(8) A 15(8) A 15(3) A 15(3) A 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC 230 V AC Contact function fig. 1b fig. 1b fig. 1a fig. 1a fig. 1a fig. 1a fig. 1a Maximum bellows pressure absolute (bar) 23 23 23 23 23 10 23 Maximum allowable diff. in pressure between the bellows (bar) 14 14 14 14 14 7 14 Pressure element material Pressure connections steel tombac/ brass steel 1 2 Style 5 Male connection Style 13 Style 15 7/16"-20 UNF for 1. 90 cm capillary 1/4"-18 NPT (female) 1/4" /6 mm flare nut 2. 7/16"-20 UNF nut for 1/4" SAE flare tube Accessories Mounting Bracket 90 cm Capillary with (2) flare nuts Compression Coupling

PB_P74_11 2010 5 Accessories Ordering Codes Code number Description Application CNR003N001R For 6 mm copper or steel tubing Compression coupling fits into Style 15 pressure connection CNR003N002R For 8 mm copper or steel tubing 271-51L Mounting Bracket SEC002N600 90 cm capillary with two flare nuts Technical Specifications Types, ranges differentials Media Pressure connections Maximum overrun pressure Ambient temperature limits -30/+55 C Material Protection Electrical ratings Shipping weight Compliance Ammonia (for special models), non-corrosive refrigerant or water - Case Cold-rolled steel, zinc plated - Cover Cold-rolled steel, grey enamel finish - Pressure element Ind. pack Overpack IP30 1.2 Kg 12 Kg (10 pcs) Johnson Controls, Inc., declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. Copyright 2010 Johnson Controls, Inc. All rights reserved. Any unauthorized use or copying is strictly prohibited. Published in Europe www.johnsoncontrols.com