Type Maxi Mix III Rotary Shaker

Similar documents
Type Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 BARNSTEAD THERMOLYNE

S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 1352

Lab Rotators and Low Cost Orbital Shakers

S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 849

Type D0800. Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494. Mo de l # Vo ltag e D D /12/08

BARNSTEAD THERMOLYNE ROTO MIX TYPE

OPERATION MANUAL AND PARTS LIST

Operating Instructions

BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS. Model No LT1186X4 5/1/00

NANOpure Infinity UV Module Upgrade

Thermo Fisher Scientific Robert-Bosch-Strasse 1,D Langenselbold,Germany.

Safety Information...3 Alert Signals...3 Warnings...3 Introduction...4 Principles of Operation...4 Declaration of Conformity...

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

BroadBand PowerShield. 20 AHr Battery. User Manual

Installation Guide. Marine Filter SURT023M SURT024M

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

2SHE Series Direct-Drive Shutter Fans

MV Series Motors Operation & Parts Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

II DISTRIBUTION & SUBSTATION TYPE C

MaxLite StaxMax LED Flood Lights

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

CTFRP Series Power Supplies

Transmission Guardian

StormPro BA Series Sump Pump

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

Installation Power Management Unit Battery Cables and Battery Harness

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

SUPER PUMP OUT SYSTEM

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Tiller Lock Assembly

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Straight-Bore Clutch LSCC-32, 44, 54

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Users Guide for Ac-sync

Veterinary Anesthesia Gas Scavenging System (Active)

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables


Broadband PowerShield. CP27U Models. User Manual

Model P-40 & Model P-25 POWER PUSHER

Nature s Generator Power Panel

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Operating and Installation Instructions

SPC-PANEL Simplex, Single Phase Pump Control Panel

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

SUNTURA SOLAR TRACKER

Installation & Operators Manual

SOLAR DASH CHARGING SYSTEM USER GUIDE

User Manual. Posture+ Adjustable Base. For customer service call:

CRD610 Automatic Fitting Inserter

StormPro BCV400 Sewage Ejector Pump

Web Volume Control Model WV220

Installation Instructions

Instruction Manual. Vortex Mixers

4-Ton Electric Log Splitter

DISCONTINUED VERSION Parts listed in this catalog may no longer be available. ILLUSTRATED PARTS CATALOG

SEMI-AUTOMATIC MEAT SLICER

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

HR-20P Pneumatically Controlled Pressure Regulator

CRD600 Automatic Fitting Inserter

Kit INSTALLATION GUIDE. For maximum effectiveness and safety, please read these instructions completely before proceeding with installation.

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

SUNTURA HD SOLAR TRACKER

G8 Portable Fuel Transfer Pump Owner s Manual

HPx-JDx3-xx HARNESS INSTALLATION

c EDR /11. ShipShape OWNERS MANUAL. [ power foundations ]

Female Plug. connecting to Fuel Quantity

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

30100 Module Installation Guide L

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

HBC-20 - LED HIGH BAY

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

PVI 60KW, PVI 82KW, PVI 95KW

INSTALLATION/OWNERS MANUAL

SUBMERSIBLE MINI-PUMP

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

SOLUTION DISTRIBUTORS BOOK NO. IM AA UA

Pressurized oil drain for collection of used lubricants and anti-freeze.

ESE Series Cast Iron Sewage Pumps

SUNC3000 / Item #40885

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

20250 Module Installation Guide

Operating Instructions & Parts Manual. Truck Drain. Model 48UJ80 and 48UJ81

BP1204 INSTALLATION/OWNER'S MANUAL

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

AD-7 THERMAL INDICATING AMMETER

DIGIGAUGE P R E S S U R E D I S P L A Y S Y S T E M I N S T R U C T I O N M A N U A L

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Transcription:

Type 65800 Maxi Mix III Rotary Shaker OPERATION MANUAL AND PARTS LIST SERIES 1046 LT1046X1 3/19/08 Model # Voltage M65820-26 230 M65820-26-60 230 M65824 100 M65825 120 M65920 230

Table of Contents Safety Information...3 Alert Signals...3 Warnings...3 Introduction...4 Principles of Operation...4 Unpacking...5 General Specifications...6 Electrical Specifications...6 Installation...7 Operation...8 Operating Specifications...8 Accessories...9 Accessory Installation...9 Troubleshooting...10 Maintenance and Servicing...11 Servicing the internal components of the rotator...11 Replacement Parts...12 Ordering Procedures...13 One Year Limited Warranty...16 2

Safety Information Alert Signals Warning Warnings alert you to a possibility of personal injury. Caution Cautions alert you to a possibility of damage to the equipment. Note Notes alert you to pertinent facts and conditions. Your Thermo Scientific Thermolyne Rotary Shaker has been designed with function, reliability, and safety in mind. It is the userʼs responsibility to install it in conformance with local electrical codes. For safe operation, please pay attention to the alert signals throughout the manual. Warnings To avoid electrical shock, always: 1. Use a properly grounded electrical outlet of correct voltage and current handling capacity. 2. Disconnect from the power supply prior to maintenance and servicing. To avoid personal injury: 1. Do not use in the presence of flammable or combustible materials; fire or explosion may result. This device contains components which may ignite such materials. 2. Do not turn on rotator unless the speed control is turned to minimum; failure to do so may cause accessories and vessels to be thrown off mixer. 3. The motor speed control disk is very sharp - be careful to avoid it while servicing. 4. Refer servicing to qualified personnel. 3

Introduction The Thermolyne Type M65800 Rotary Shakers are general purpose laboratory rotators. They are intended for vortexing single or multiple test tubes, flasks, Petri dishes or other laboratory vessels from 100 2200 RPM. Accessory attachments are available for test tube or flask vortexing, Petri dish rotation, flask shaking, and flask and/or tube platform shaking. Principles of Operation The rotary shaker consists of a permanently lubricated DC motor and solid state electronic speed control. Pulses from an optical pick-up are converted by the control to a voltage proportional to speed. This voltage is compared to the set point voltage and the control automatically maintains rotator speed even with changes in loading or fluctuations in line voltage. Spring dampened feet are incorporated to prevent unit movement during use. 4

Unpacking Unpack the Type M65800 Rotary Shaker from the box. A PT500X6A Vortex Mixer accessory is included with the basic unit. 5

General Specifications Height: Width : Depth : Weight : 5 1/8 (13 cm) 6 1/2 (16.5 cm) 8 1/2 (21.6 cm) 15 lb. (6.8 kg) Electrical Specifications Model Volts Amps Hz Approx. Speed (RPM) M65820-26 230 0.2 50/60 100-2200 M65820-26-60 230 0.2 50/60 100-2200 M65824 100 0.5 50/60 100-2200 M65825 120 0.4 50/60 100-2200 The electrical specifications are also located on the specification plate on the bottom of the unit. 6

Installation Warning To avoid electrical shock, use with a properly grounded electrical outlet of correct voltage and current handling capacity. 1. Place the rotary shaker on a sturdy, flat surface. 2. Plug it in. Warning To avoid personal injury, do not use in the presence of flammable or combustible chemicals fire or explosion may result. This device contains components which may ignite such materials. 7

Operation Warning To avoid personal injury, do not turn the rotator on unless the speed control is turned to minimum; failure to do so may cause accessories and vessels to be thrown off the rotary shaker. Power Switch The power switch enables power to the motor and speed control to be turned on and off. Speed Control The speed is set by means of a single turn adjustment knob. Markings on the dial plate indicate approximate speed from 100 2200 RPM. Operating Specifications The Maxi Mix III is rated for continuous use. Orbit size: 4 mm. Maximum recommended load capacity is 5 lb (2.3 kg). (Dependent on type of load and accessory combination.) Ambient temperature range: 5 40 C Relative humidity range: 20-80% 8

Accessories Accessories for the Type 65800 Rotary Shakers must be ordered separately. Contact your dealer for the following Thermolyne part numbers: PT500X6A, Vortex accessory PT500X7A, Petri dish platform accessory PT500X8A, Flask shaking accessory PT500X9A, Flask/test tube rack platform accessory Accessory Installation 1. Loosen the two front thumbscrews securing the foam rubber platform supplied with the Maxi-Mix III. Remove the one back thumbscrew securing the foam rubber platform. Remove the foam rubber platform. 2. Place the desired accessory on top of the rotary shaker. Replace the one back thumbscrew. Tighten the two front thumbscrews to secure the attachment. 9

Troubleshooting Warning To avoid electrical shock, always disconnect from power supply before maintenance and servicing. Refer servicing to qualified personnel. This Troubleshooting guide is intended to aid in defining and correcting possible service problems. Problem Possible Causes Solution Rotary shaker will not No power to unit Check that unit is plugged into rotate receptacle of the correct voltage Blown fuses* Defective motor Defective speed control circuit board Transformer open circuit Replace fuses* Replace motor Replace PC board Replace transformer Rotary shaker speed will not Defective set point potentiometer. Replace potentiometer regulate, turns at some intermediate speed Rotary shaker runs at full Defective transistor on Replace transistor main circuit speed, will not slow down board * M65820-26-60 only 10

Maintenance and Servicing Warning To avoid electrical shock, always disconnect from power supply before maintenance and servicing. Refer servicing to qualified personnel. Warning The motor speed control disk is very sharp be careful to avoid it while servicing. Servicing the internal components of the rotator 1. Remove the accessory in use. 2. Remove the four screws securing the top to the motor assembly. 3. Pull up firmly to remove the top from the unit. 4. Remove the four screws securing the top case to the bottom rotator plate. 5. Replace defective components. 6. Reassemble in the reverse order using steps 4-1. 11

Replacement Parts Warning To avoid electrical shock, always disconnect from power supply before maintenance and servicing. Refer servicing to qualified personnel. Model Type: M65800 Product Name: Maxi Mix III Rotary Shaker Series Number: 1046 Part No. Qty. Description BRX25 2 Bearing CR500X1 1 Cord set assembly (100V, 120V) CR500X2 1 Cord set assembly (230V) KBX27 1 Knob MT1046X1A 1 Motor assembly PC658X1A 1 Speed control board RS658X1A 1 Control potentiometer SRX10 1 Strain relief SWX137 1 Switch, power (100V, 120V) SWX138 1 Switch, power (230V) FTX7 4 Foot SP500X1 4 Spring TN658X1A 1 Transformer for M65825 TN658X2A 1 Transformer for M65824 TN658X3A 1 Transformer for M65820-26, M65820-26-60 5120-0016 1 Fuse for M65820-26-60 FZX54 1 Fuse for M65824 & M65825 (Type T, 250 volt,.63 Amp) 12

Ordering Procedures Please refer to the Specification Plate for the complete model number, serial number, and series number when requesting service, replacement parts or in any correspondence concerning this unit. All parts listed herein may be ordered from the Thermo Scientific dealer from whom you purchased this unit or can be obtained promptly from the factory. When service or replacement parts are needed we ask that you check first with your dealer. If the dealer cannot handle your request, then contact our Customer Service Department at 563-556-2241 or 800-553-0039. Prior to returning any materials, please contact our Customer Service Department for a Return Materials Authorization number (RMA). Material returned without an RMA number will be refused. 13

14

15

One Year Limited Warranty This Thermo Scientific product is warranted to be free of defects in materials and workmanship for one (1) year from the first to occur of (i) the date the product is sold by the manufacturer or (ii) the date the product is purchased by the original retail customer (the Commencement Date ). Except as expressly stated above, the MANUFACTURER MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO THE PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES, INCLUDING BUT NOT LIMITED TO, WARRANTIES OF DESIGN, MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE. An authorized representative of the manufacturer must perform all warranty inspections. In the event of a defect covered by the warranty, we shall, as our sole obligation and exclusive remedy, provide free replacement parts to remedy the defective product. In addition, for products sold within the continental United States or Canada, the manufacturer shall provide free labor to repair the products with the replacement parts, but only for a period of ninety (90) days from the Commencement Date. The warranty provided hereunder shall be null and void and without further force or effect if there is any (i) repair made to the product by a party other than the manufacturer or its duly authorized service representative, (ii) misuse (including use inconsistent with written operating instructions for the product), mishandling, contamination, overheating, modification or alteration of the product by any customer or third party or (iii) use of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific products. Heating elements, because of their susceptibility to overheating and contamination, must be returned to the factory and if, upon inspection, it is concluded that failure is due to factors other than excessive high temperature or contamination, the manufacturer will provide warranty replacement. As a condition to the return of any product, or any constituent part thereof, to the factory, it shall be sent prepaid and a prior written authorization from the manufacturer assigning a Return Materials Number to the product or part shall be obtained. IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY PARTY FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, OR FOR ANY DAMAGES RESULTING FROM LOSS OF USE OR PROFITS, ANTICIPATED OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THE SALE, USE OR PERFORMANCE OF ANY PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE), ANY THEORY OF STRICT LIABILITY OR REGULATORY ACTION. For the name of the authorized Thermo Scientific product dealer nearest you or any additional information, contact us: 2555 Kerper Blvd., Dubuque, Iowa, 52004-0797 Phone: 563-556-2241 or 1-800-553-0039 Fax: 563-589-0516 E-mail: mkt@thermofisher.com Web: www.thermo.com