DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS)

Similar documents
PRESSURE CONTROLS TECNORD

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Directional Control Valves

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

Pressure Reducing Valves

P.C. Priority Flow Control Valve Series J02D3. General Description

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

Pressure Control Valves

Check valves Direct and pilot operated check valve functions for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

DRV2-080 Adjustable, Direct-Acting Relief Valve

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

High Speed Hydraulic Motors. Catalog HY /NA zm16 zm17

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Pressure Control Valves

High Speed Hydraulic Motors

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Logic elements. Differential pressure sensing elements for applications up to 350 bar (5000 psi) and 400 L/min (100 USgpm)

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Low Pressure Filters

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

Hydraulic and Pneumatic In-line and Cartridge Insert Control Valves for any fluid or gas.

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

Sandwich Valves Series CP

HPK04 Max Flow: 120 gpm (454 lpm)

Pressure Control Valves. General Description. Specifications. Ordering Information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

MEDIUM PRESSURE FILTERS MFX Series Inline Filters 725 psi up to 35 gpm Hydraulic Symbol

FPK02 In-Line Cartridge Filters

FPK04 Max Flow: 100 gpm (379 lpm)

Full Range Pressure Compensating Variable Flow Control

INSTALLATION DIMENSIONS

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS

PILOT OPERATED PRESSURE CONTROLS - FLANGED TYPE VR5 Series

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL)

CHECK VALVE - DIRECT OPERATED - Series VC4V SPECIFICATIONS PERFORMANCE CURVES VC4V03 VC4V10 VC4V06

36EFC. Series & EFC Valve Package

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Heavy Duty Hydrostatic Transmissions

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Fixed Displacement Gear Pumps

Contents. Quality Hydraulic Components from the Webtec Range. Introduction. Hydraulic Flow Control Valves

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

Proportional Valves. Proportional solenoid valves for pressure and flow control

Eaton Char-Lynn Spool Valve Hydraulic Motors

PT Series Tank Top Filters

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)

Service and Parts Manual. Minimum Filtration Required:

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

12CS/50CS Series. Coreless Spin-on Filters

Housings and Miscellaneous Parts

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

PILOT OPERATED SEQUENCE VALVE - Series VR4S

Hydraulic gear pumps and motors

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

12CS/50CS Series Coreless Medium Pressure Filters

4-Way Directional Control Valve With Hydraulic Kick Out

Contents. Directional Control Valve 2 Series CV 300

W SERIES HYDRAULIC MOTORS. WM600 Flange Options

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

Fluid Cooling Industrial COLW Series

PILOT OPERATED PRESSURE RELIEF VALVE - Series VR4V

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

PFM6 Digital Portable Hydraulic Tester

12AT/50AT Series Spin-On Filters

Genuine Metaris MA10VO/VSO Technical Catalog. Variable Displacement Piston Pump - A10V Series 31 & 52

Content. How to Order... Custom Worksheet... Cmmon Application Circuits... Typical Central Manifold, Cavities and Valves Central Manifold...

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Monarch D.C. Hydraulic Power Systems. Comprehensive information may be found on the page referenced below each selection category.

MEDIUM PRESSURE FILTERS

Displacements cm 3 /r [in 3 /r] Design code [21.0] 400 [24.4] 434 [26.5] 480 [29.3] 677 [41.3] HP30 Motor

Variable displacement axial piston pumps

D05 Directional Control Valves

D03, D05 & D08 SERIES

Heavy Duty Hydrostatic Transmissions

Vickers. Proportional Valves. EPV10 Series. Proportional Flow Controls. Released 6/95

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

Series 34. Sectional Directional Control Valve Specifications: P34A Engineering & Manufacturing Solutions

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Contents. Directional Control Valve 3 Series CV 452. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves.

Insert Valves Flow control

VIS (Valve-In-Star) Hydraulic Motor

HPV-10 AXIAL PISTON PUMPS

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

HPV-15 AXIAL PISTON PUMPS

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

Transcription:

DOUBLE, P.O. CHECK VALVES (PRE-ENGINEERED BLOCKS) SERIES DOUBLE PILOT OPERATED CHECK VALVE... HS3 Page HD1

Page HD2

SERIES DOUBLE PILOT OPERATED CHECK VALVE GPM PSI LPM BAR CAVITY MODEL PAGE 5 3500 19 241 5/8-18 MD-POC HD4 10 3500 38 241 3/4-16 PD-POC HD6 15 3500 57 241 7/8-14 DD-POC HD8 40 3500 151 241 5/46-12 SD-POC HD10 15 4000 57 276 7/8-14 DD-POT HD12 TYPICAL SCHEMATIC Typical application for this valve is load holding when pump is off. Page HD3

MD-POC DOUBLE PILOT OPERATED CHECK VALVE DESCRIPTION 7 size, 5/8-18 thread, Mini series, double pilot operated check valve. OPERATION The MD-POC allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to (V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite valve (V1) and/or port (V2) accordingly. The valve has a 6.7:1 pilot ratio, so at least.141 of the load pressure at port (C1) or (C2) is required at the pilot lines ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or (C2) respectively. The check is spring-biased at 50 PSI (3.4 bar) to assure holding in static or no-load conditions. FEATURES Hardened internal parts for long life. Anodized aluminum body for corrosion protection. HYDRAULIC SYMBOL TYPICAL SCHEMATIC VALVE SPECIFICATIONS Nominal Flow 5 GPM (19 LPM) Rated Operating Pressure 3500 PSI (241 bar) Typical Internal Leakage (150 SSU) 0-5 drops/min Viscosity Range 36 to 3000 SSU (3 to 647 cst) Filtration 30 micron nominal Pilot Ratio 6.7:1 Media Operating Temp. Range -40 to 250 F (-40 to 120 C) Weight.92 lbs (.42 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 15 ft-lbs (20.3 Nm) Cartridge Crack Pressure 50 PSI (3.4 bar) Page HD4

DELTA POWER HYDRAULIC CO. ROCKFORD, ILLINOIS U.S.A. HYDRAULIC INTEGRATED CIRCUITS DIMENSIONS.19 [4.8].63 [16.0].31 [8.0] 2.00 [50.8] 1.31 [33.3] 1.25 [31.8].63 [15.9] 1.07 [27.2] V2 V1 2.31 [58.7].54 [13.6] 1.16 [29.5] 3.38 [85.9].45 [11.4] C1 C2 1.08 [27.3].46 [11.6] SAE PORTS SHOWN MTG. HOLES ARE.28 DIA. NOTE: DIMENSIONS IN BRACKETS ARE MILLIMETERS O-RINGS ARE STANDARD ON PISTON ASSEMBLY CHECK VALVE USED IS A MA-CVA ORDERING INFORMATION MD-POC OPTIONS BODIES Buna Standard B N 1/4 NPTF Ports Viton Standard V S #4 SAE Ports Page HD5

PD-POC DOUBLE PILOT OPERATED CHECK VALVE DESCRIPTION 8 size, 3/4-16 thread, Power series, double pilot operated check valve. OPERATION The PD-POC allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to (V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite valve (V1) and/or port (V2) accordingly. The valve has a 4:1 pilot ratio, so at least.250 of the load pressure at port (C1) or (C2) is required at the pilot lines ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or (C2) respectively. The check is spring-biased at 50 PSI (3.4 bar) to assure holding in static or no-load conditions. FEATURES Hardened internal parts for long life. Anodized aluminum body for corrosion protection. HYDRAULIC SYMBOL TYPICAL SCHEMATIC VALVE SPECIFICATIONS Nominal Flow 10 GPM (38 LPM) Rated Operating Pressure 3500 PSI (241 bar) Typical Internal Leakage (150 SSU) 0-5 drops/min Viscosity Range 36 to 3000 SSU (3 to 647 cst) Filtration 30 micron nominal Pilot Ratio 4:1 Media Operating Temp. Range -40 to 250 F (-40 to 120 C) Weight 1.2 lbs (.54 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 25 ft-lbs (34 Nm) Cartridge Crack Pressure 50 PSI (3.4 bar) Page HD6

DIMENSIONS ORDERING INFORMATION PD-POC OPTIONS BODIES Buna Standard B N 1/4 NPTF Ports Viton Standard V S #6 SAE Ports Page HD7

DD-POC DOUBLE PILOT OPERATED CHECK VALVE DESCRIPTION 10 size, 7/8-14 thread, Delta series, double pilot operated check valve. OPERATION The DD-POC allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to (V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite valve (V1) and/or port (V2) accordingly. The valve has a 4:1 pilot ratio, so at least.250 of the load pressure at port (C1) or (C2) is required at the pilot lines ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or (C2) respectively. The check is spring-biased at 90 PSI (6.2 bar) to assure holding in static or no-load conditions. FEATURES Hardened internal parts for long life. Anodized aluminum body for corrosion protection. HYDRAULIC SYMBOL TYPICAL SCHEMATIC VALVE SPECIFICATIONS Nominal Flow 15 GPM (57 LPM) Rated Operating Pressure 3500 PSI (241 bar) Typical Internal Leakage (150 SSU) 0-5 drops/min Viscosity Range 36 to 3000 SSU (3 to 647 cst) Filtration 30 micron nominal Pilot Ratio 4:1 Media Operating Temp. Range -40 to 250 F (-40 to 120 C) Weight 1.5 lbs (.68 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 30 ft-lbs (40.6 Nm) Cartridge Crack Pressure 90 PSI (6.2 bar) Page HD8

DIMENSIONS ORDERING INFORMATION DD-POC OPTIONS BODIES Buna Standard B N 3/8 NPTF Ports Viton Standard V S #8 SAE Ports Page HD9

SD-POC DOUBLE PILOT OPERATED CHECK VALVE DESCRIPTION 16 size, 1 5/16-12 thread, Super series, double pilot operated check valve. OPERATION The SD-POC allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to (V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite valve (V1) and/or port (V2) accordingly. The valve has a 3.7:1 pilot ratio, so at least.267 of the load pressure at port (C1) or (C2) is required at the pilot lines ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or (C2) respectively. The check is spring-biased at 50 PSI (3.4 bar) to assure holding in static or no-load conditions. FEATURES Hardened internal parts for long life. Anodized aluminum body for corrosion protection. HYDRAULIC SYMBOL TYPICAL SCHEMATIC VALVE SPECIFICATIONS Nominal Flow 40 GPM (151 LPM) Rated Operating Pressure 3500 PSI (241 bar) Typical Internal Leakage (150 SSU) 0-5 drops/min Viscosity Range 36 to 3000 SSU (3 to 647 cst) Filtration 30 micron nominal Pilot Ratio 3.7:1 Media Operating Temp. Range -40 to 250 F (-40 to 120 C) Weight 6.0 lbs (2.7 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 90 ft-lbs (122 Nm) Cartridge Crack Pressure 50 PSI (3.4 bar) Page HD10

DIMENSIONS ORDERING INFORMATION SD-POC OPTIONS BODIES Buna Standard B S #12 SAE Ports Viton Standard V Page HD11

DD-POT DOUBLE PILOT OPERATED CHECK VALVE W/THERMAL RELIEF VALVE DESCRIPTION 10 size, 7/8-14 thread, Delta series, double pilot operated check valve with thermal relief valve. OPERATION The DD-POT allows flow to pass from (V1) to (C1) and (V2) to (C2). The valve blocks flow from (C1) to (V1) and from (C2) to (V2). Blocked flow is released when pilot pressure is applied to port opposite valve (V1) and/or port (V2) accordingly. Also (C2) port is protected by thermal relief. The valve has a 4:1 pilot ratio, so at least.250 of the load pressure at port (C1) or (C2) is required at the pilot lines ports (V2) or (V1) respectively to open the flow passage to allow flow from ports (C1) or (C2) respectively. The check is spring-biased at 90 PSI (6.2 bar) to assure holding in static or no-load conditions. FEATURES Hardened internal parts for long life. Anodized aluminum body for corrosion protection. HYDRAULIC SYMBOL TYPICAL SCHEMATIC VALVE SPECIFICATIONS Nominal Flow 15 GPM (57 LPM) Rated Operating Pressure 4000 PSI (276 bar) Typical Internal Leakage (150 SSU) 0-5 drops/min Viscosity Range 36 to 3000 SSU (3 to 647 cst) Filtration 30 micron nominal Pilot Ratio 4:1 Media Operating Temp. Range -40 to 250 F (-40 to 120 C) Weight 1.4 lbs (63 kg) Operating Fluid Media General Purpose Hydraulic Fluid Cartridge Torque Requirements 30 ft-lbs (40.6 Nm) Cartridge Crack Pressure 90 PSI (6.2 bar) Page HD12

DIMENSIONS ORDERING INFORMATION DD-POT OPTIONS BODIES Buna Standard B N 3/8 NPTF Ports Viton Standard V S #8 SAE Ports Page HD13