Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Similar documents
Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Product Data. Residential Zone Dampers FEATURES/BENEFITS

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

Installation and Start-Up Instructions

Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Description. functions including single duct pressure dependent or pressure independent systems.

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Product Data. 35J Single-Duct Retrofit Terminal Units for Variable Air Volume Systems. 40 to 3700 cfm

Installation Instructions

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

Installation and Start Up Instructions

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

YCCS Zone/Bypass Damper Assembly

Wiring Diagrams (Including Accessories) (50/60 Hz)

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

Installation, Service, and Troubleshooting Instructions

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig.3 Slip-InDamper. Fig.1 RoundDamper

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Wiring Diagrams DIAGRAM INDEX

Installation Instructions

Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

YCCS Zone/Bypass Damper Assembly

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

Product Data. Features/Benefits. 35E Single Duct Terminal Units for Variable Air Volume Systems. Nominal 45 to 7100 cfm

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Installation Instructions

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

Installation/ Operation Maintenance. VariTrac Dampers

ZoneTouch V2 Zone Control System Installation Manual

INFINITY ZONING QUICK START GUIDE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Installation Instructions

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

Product Data ZONE DAMPERS FEATURES/BENEFITS. Fig. 3 - Slip -In Damper. Fig. 1 - Round Damper

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

Laboratory Room Controller

4.1 Functional diagram FM100 fume hood monitor... 4 Functional description FM Interfaces Terminal diagram FM100...

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

Voyager Microcontrols

HML - Airflow Unit for Large Volumes. HML Airflow Unit for Large Volumes. with Centralized Airflow Heating

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

13 SEER Light Commercial 3 Phase

Ducted medium static pressure monosplit DC Inverter

CCS Zone/Bypass Damper Assembly

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

Product Data. Features/Benefits. 45J,M,K,N,Q,R Standard, Quiet, and Low Profile Fan Powered Variable Air Volume Terminals.

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

18SP589* Series 60 Right Side EGR Bolt-Together System with Hydraulic Actuator Valve

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

PRAC14 PRODUCT SPECIFICATIONS

Installation Instructions Electric Heaters 5 20 kw

MicroMetl INSTALLATION INSTRUCTIONS FOR 0689ZJ36EC

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

PART MATERIAL PART MATERIAL. Casing Hot galvanized steel / Option: stainless steel EN (AISI316L) Reheat coil EN 1.

University of Delaware

Installation Instructions

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Installation Instructions Electric Heaters 5 20 kw

Metasys Zoning Package Installation

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

2010 Duct-Free Splits Line Card

INSTALLATION INSTRUCTION

Instruction Manual MINI IRRIGATION CONTROLLER.

HMR DUAL DUCT CABIN UNIT CABIN UNITS HMR. For passenger and crew cabins

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

ZONE DAMPERS. Form No. PDS DAMP.0.3

Ductless Split Systems

3000VA 120/208/230VAC

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

Excel 10 W7751H3007 VAV ACTUATOR

Designed for ease of integration with automation systems

SetPoint 150 Controller Installation Manual

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

SetPoint 501 and 501s Controllers Installation and Operation Manual

Design Guide INTRODUCTION

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

INSTALLATION INSTRUCTIONS T-59 SPACE TEMPERATURE SENSOR WITH OVERRIDE & SETPOINT ADJUSTMENT

Start-Up, Operation and Service Instructions

Installation Instructions

Application Engineering

WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

PIM Pressure Independent Module

BAS Construction Checklist

Transcription:

Product Data ZONEKIT4ZCAR Comfort Zone Residential Zoning System Comfort Zone is a residential 4-zone system integrated for home comfort. The Comfort Zone kit includes the Comfort Zone Center, 4-zone controller, 3 remote room sensors, and a duct temperature sensor. COOL 72 68 HEAT 2:45 Features/Benefits Fully Communicating DDC controls with either direct or remote communication through personal computer. (Optional software and ISO-O2/Modem required.) Fully Modulating Dampers Time modulating dampers that deliver precise airflow where and when it s needed. Adjustable Temperature Setpoints 14 degree sliding scale setpoint adjustment. Programmable 5-1-1, (Mon. Fri., Sat., Sun.) with 4 time/ temperature settings per schedule. No Batteries Required Nonvolatile RAM chip requires no battery backup. Program is retained in memory so reprogramming is not required after power loss. Time clock retains time for approximately 8 hours before resetting is required. Diagnostic Error Display System failures are easy for service technician to diagnose and fix, saving both time and money. Vacation Mode Just by rotating the dial and adjusting the setpoint temperature puts all 4 zones in vacation mode. After returning from vacation simply restore dial to any zone and the system returns to regular program. Timeguard Equipment protection. Copyright 1995 Carrier Corporation ZONEKIT4-1PD

Smart Start Used for heat pump operation to optimize the energy savings when coming out of setback. Temperature Trend Staging Optimizes energy savings by delaying second stage operation based off the temperature trend in the space. If the space temperature is the same or getting worse after 6 minutes, second stage is turned on. If the space temperature is improving, second stage is delayed. Dimensions 1 3 4 (TYP) 1 4 (TYP) 15 3 4 2 1 8 1 1 4 (TYP) REMOTE ROOM SENSOR 9 13 16 COMFORT ZONE CENTER 7 1 2 5 3 4 COOL 72 68 HEAT 2:45 3 7 8 3 2 4 ZONE CONTROLLER DUCT TEMPERATURE SENSOR A93428 2

Electrical data MODEL POWER SUPPLY ELECTRICAL RATING FOR ACTUATORS WIRING ZONEKIT4ZCAR 24vac, 50-va, 60 hz isolated transformer field supplied. Add 5-va transformer for each additional damper over 4. 24 vac, 5-va, 60hz. Supplied from Comfort Zone Center Actuators factory mounted on dampers. Cycling time is 15 sec. Shielded cable is recommended to reduce noise interference. (See table below.) Wiring requirements FROM COMFORT ZONE CENTER TO NO. OF WIRES GAGE MAX. LENGTH (FT) FOUR ZONE CONTROLLER 3* 18/22 200/100 5* 18/22 200/100 REMOTE ROOM SENSORS 2* 18/22 200/100 DUCT TEMPERATURE SENSOR 2* 18/22 200/100 DX COIL SENSOR 2* 18/22 200/100 HOME ACCESS MODULE 3* 18/22 1000/100 DAMPERS 3* 18 1000 ISOSAT 3* 18/22 1000/100 TRANSFORMER 2* 18 75 * Shielded cable recommended to reduce noise interference. When using ISOSATS in interfacing multiple buses together, the length of wiring between ISOSATS cannot exceed 4000 ft with 18 gage. 24vac, 50 75va. 3

Accessories ORDERING NUMBER DESCRIPTION DAMPRND06INC Round Damper 6 in. DAMPRND08INC 8 in. DAMPRND10INC 10 in. DAMPRND12INC 12 in. DAMPRND14INC 14 in. DAMPRND16INC 16 in. DAMPREC08X10 Rectangular Damper 8 x 10 in. DAMPREC08X14 8 x 14 in. DAMPREC08X18 8 x 18 in. DAMPREC08X24 8 x 24 in. DAMPREC10X10 10 x 10 in. DAMPREC10X14 10 x 14 in. DAMPREC10X18 10 x 18 in. DAMPREC10X24 10 x 24 in. DAMPSLS08X10 Slip-in damper, Side mount, 8 x 10 DAMPSLB08X10 Bottom mount, 8 x 10 DAMPSLS08X12 Side mount, 8 x 12 DAMPSLB08X12 Bottom mount, 8 x 12 DAMPSLS08X14 Side mount, 8 x 14 DAMPSLB08X14 Bottom mount, 8 x 14 DAMPSLS08X16 Side mount, 8 x 16 DAMPSLB08X16 Bottom mount, 8 x 16 DAMPSLS08X18 Side mount, 8 x 18 DAMPSLB08X18 Bottom mount, 8 x 18 DAMPSLB08X20 Bottom mount, 8 x 20 DAMPSLB08X22 Bottom mount, 8 x 22 DAMPSLB08X24 Bottom mount, 8 x 24 DAMPSLS10X10 Side mount, 10 x 10 DAMPSLB10X10 Bottom mount, 10 x 10 DAMPSLS10X12 Side mount, 10 x 12 DAMPSLB10X12 Bottom mount, 10 x 12 DAMPSLS10X14 Side mount, 10 x 14 DAMPSLB10X14 Bottom mount, 10 x 14 DAMPSLS10X16 Side mount, 10 x 16 DAMPSLB10X16 Bottom mount, 10 x 16 DAMPSLS10X18 Side mount, 10 x 18 DAMPSLB10X18 Bottom mount, 10 x 18 DAMPSLB10X20 Bottom mount, 10 x 20 DAMPSLB10X22 Bottom mount, 10 x 22 DAMPSLB10X24 Bottom mount, 10 x 24 DAMPSLB14X20 Bottom mount, 14 x 20 DAMPBAR08X14 Barometric Bypass Damper 8 x 14 DAMPBAR08X24 Barometric Bypass Damper 8 x 24 DAMPACT90DEG Slip-in damper 90 (for rect. ductwork) replacement damper actuator DAMPACT45DEG Slip-in damper 45 (for round ductwork) replacement damper actuator ZONEHAMCAR4Z Home Access Module (HAM) ZONESMSENCAR Smart Sensor ZONESMSENPPC Smart Sensor Power Pack (one required per system)* ZONEIOCENTCA Comfort Zone I/O Center ZONE4ZCONTCA Four Zone Controller ZONESMSENCBD Smart Sensor Connector Board ZONEFUSEPACK Comfort Zone Fuse Pack ZONEIOBDCARR Comfort Zone Input/Output Board ZONEMLTDMPEN Multi-Damper Enabler ZONECZCCCARR Comfort Zone Command Center Software ZONE4ZCONCOV Four Zone Controller Cover See notes on page 5. 4

Accessories continued ORDERING NUMBER DESCRIPTION 920089 Outdoor Air Temp. Sensor (OAT)* (used on Rev. 1.3 or less) 920247 Refrigerated Air Sensor (RAS)* (used on Rev. 1.4 or greater) 920076 Duct Temperature Sensor (DTS) 920076 Dx Coil Sensor 920008 CHR06 920077 Remote Room Sensor* 920475 Comfort Zone Design Center Software * Required when using Smart Sensor in place of remote room sensor. Use Commercial Unitary C-1 order plan 5

Typical first floor zoning ZONE 2 ZONE 1 ZONE 3 A93432 Typical second floor zoning ZONE 4 A93433 Printed on recycled paper. Copyright 1995 Carrier Corporation Syracuse, New York 13221 6-95 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 1 1 4 4 4 Page 6 Catalog No. 809-567 Printed in U.S.A. PC 101 Form ZONEKIT4-1PD Tab 3a 5 6 2a 5a 8a Replaces: 920415-1PD