Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Similar documents
Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

MAXIMUM OUTPUT AC SUPPLY INPUT SPEED RANGE USER ADJUSTMENT EXTERNAL CONTROL CONTROL ACTION INSTALLATION

User Guide 4Q kW D.C.Motor Regenerative Speed Controller. Part Number: Issue Number: 3

SINGLE PHASE DC DRIVES

Ultra compact DC motor control. Non isolated.

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor Series 2230 MKII/2240

CONTROL FEATURES AVAILABLE OPTIONS

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

SAFTRONICS DF8 PLUS SERIES

506/507/508. Product Manual. HA Issue 13. Copyright 2013 Parker Hannifin Manufacturing Ltd. WARRANTY

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

MaxPak Plus Analog DC V S Drive

THREE PHASE DC DRIVES

Installation & Operation Manual

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Boston Gear Ratiotrol

MX431 Generator Automatic Voltage Regulator Operation Manual

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

506/507/508. Product Manual WARRANTY. HA Issue 10. Copyright 2007 Parker SSD Drives, a division of Parker Hannifin Ltd.

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

HIB Enclosed Inverter User Guide

A WARNING GIVES THE READER INFORMATION WHICH IF DISREGARDED COULD CAUSE INJURY OR DEATH

Boston Gear Ratiotrol DC Motor Speed Control

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

512C Series. Product Manual EUROTHERM DRIVES. HA Issue 7. ! Copyright Eurotherm Drives Limited 2001

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

Open Chassis Star-Delta Starter User Guide

Boston Gear Ratiotrol DC Motor Speed Control

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

110 Years Expertise DC Motors AC Motors Digital Drives MOTOR CONTROL TECHNOLOGY PRODUCT CATALOGUE THREE PHASE DRIVES: TT/X RANGE

THREE PHASE DC DRIVES

SUM340 SUMMATION BOARD

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

512C Series. Product Manual EUROTHERM DRIVES. HA Issue 7. ! Copyright Eurotherm Drives Limited 2001

SDS Enclosed Star-Delta Starter User Guide

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DC3N Non-Regenerative DC Drives

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

Powerframes - Power Electronics

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Boston Gear Ratiotrol

17429X.00 SERIES MODELS:

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Powerframes - Power Electronics

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

Filtered PWM Speed Control for Permanent Magnet DC Motors

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

Boston Gear Ratiotrol

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

Slip Ring Drive product manual V1.0 JL/X JL/XHD75-975


Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

3 - Protection components Motor circuit-breakers

5001TCP SPEED CONTROLLER

Boston Gear Ratiotrol DC Motor Speed Control

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric

Central Battery Systems Loadstar AC/DC Systems

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

User Guide. Mini Maestro. Variable Speed Drive for Permanent-magnet DC Servo-motors. Part Number: Issue: 5.

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Electric Motor Controls BOMA Pre-Quiz

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

1 Phase electronic contactor (SC 1)

P6550 PROGRAMMABLE MULTI-FUNCTION THYRISTOR CONTROL CARD

Installation and Operation Manual. *See page 6 for CE Information

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

5001TCP SPEED CONTROLLER

Boston Gear RB Series

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

DC Variable Speed Drive Panel

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

REVISED ATM72 Auto Transfer Module

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

DC Drive Selection Guide

Transcription:

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback from the armature voltage (Avf), or from a shaft mounted tachogenerator. It incorporates an accurate current control loop to protect the drive and motor, and can be used in speed or current control modes. The drive can operate in forward or reverse, motoring or regenerative braking. Please obtain expert help if you are not qualified to install this equipment. Make safety a priority. This component is hazardous. (All specifications in this document are nominal). ER-340XRi 0.55KW (0.5 HP) at 180 Volts DC, 3.4 Amps POWER RATING ER-680XRi 0.75KW (1.0 HP) at 180 Volts DC, 6.8 Amps ER-1220XRi 1.80KW (2.0 HP) at 180 Volts DC, 12.2 Amps Versions that work from 60V / 30V AC supply are also available. ER-340XRi/LV60, ER-680XRi/LV60, ER-1220XRi/LV60. For motors rated up to 48V DC MAXIMUM OUTPUT AC SUPPLY INPUT SPEED RANGE USER ADJUSTMENTS Armature: +/-200 Volts DC, or +/-50V for LV60 models. Models ER-340XRi / ER-680XRi /ER-1220XRi - 3.4/ 6.8/ 12.2 Amps. Field: Volts DC= 0.9 x AC supply volts. 1 Amp (0.45 x AC for field connected to F- and N). 1 Amp. 110V AC or 240V AC +/-10%, 50 60 Hz. 30V AC or 60V AC +/-10%, 50-60Hz for LV60 models. Speed range 0 100%. (motor dependant) Load Regulation typically 0.2% tach, 2% Arm Volts. Presets accessible under lift up cover. Clockwise rotation for linear increase in parameter. Relay driver threshold (Level) +/-(0.5% to 105%). (+/-10.5V) Symmetrical about zero. Maximum Speed (Max spd) 40V-200V span with Spd x 2 switch. (Avf/Tach fb volts) LV60 models have an Avf range 10-50V. Minimum Speed (Min spd) 0 to 30% of maximum speed. (With 10K external pot). Up Ramp (Ramp ) 20 to 1 seconds up ramp rate. (For 0 to +10V) Down Ramp (Ramp ) 20 to 1 seconds down ramp rate (For +10 to 0V) Stability (Stab) Gain 1 to 10 Maximum Current (I max) 0 to 100% current limit. IR compensation (IR comp) 0 to 25% EXTERNAL CONTROLS Speed setpoint from external 10K Ohms pot. External RUN contact for electronic STOP/START. Built in functions are+/- channel with pushbutton control inputs, and relay driver with variable threshold. There is a pot kit available with graduated dial and knob. Eurotherm part ref. POTKIT. CONTROL ACTION INSTALLATION Speed loop: Full P+I armature voltage feedback. Current loop: Full P+I isolated current feedback. Use correctly rated cable minimum 600V AC, 1.5 times armature current.

2 Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual FUSING REQUIREMENT Eurotherm semi-conductor fuse parts. 20A fuse 6 X 32 CH00620A Fuseholder 6 X 32 CP102071 DIN rail clip for fuseholder FE101969 Suitable for use on a circuit capable of delivering not more than 5000A RMS symmetrical amperes when protected by an Ar class fuse. WARNING The drive can only be protected by fitting an external AC supply semi-conductor fuse with an I 2 t rating below 150 A 2 s. CONTROL SIGNALS Control signals are isolated from the supply, and the unit may be connected to other isolated instruments. MECHANICAL The unit is designed to clip onto a DIN rail. Avoid vibration and ambient temperatures outside 10 and +40C. Protect the unit from pollutants. Ensure there is an adequate supply of clean cool air to ventilate the unit and the enclosure it is mounted in. (Dissipation in Watts = 5 x Armature Amps). MOTOR Foot mounted motors must be level and secure. Protect motors from ingress of foreign matter during installation. Ensure accurate alignment of motor shaft with couplings. Do not hammer pulleys or couplings onto the motor shaft. Before running motor, complete the following check list. (Warning isolate the supply first). 1) Correct insulation between all motor windings and earth. Disconnect all drive cables. 2) Check inside connection box for foreign objects, damaged terminals etc. 3) Check that brushes are in good condition, correctly seated and free to move in brush boxes. Check correct action of brush springs. 4) Motor vents must be freed of any obstruction or protective covers prior to running. AC SUPPLY To avoid damage, ensure the supply selection jumper on the drive matches the incoming supply. 110V or 240V AC. For models with LV60 suffix. 30V or 60V AC. PRESET POT settings Set the I max (Max Current) preset to approximately match the motor armature rating. Fully clockwise is 100% drive rating. (ER-340XRi 3.4A, ER-680XRi 6.8A, ER-1220XRi 12.2A). Fully anticlockwise is 0%. E. g. for a ER- 340XRi unit a midway setting is 50% i.e. 1.7A. More accurate setting requires a suitable current meter in series with the armature. Set the Stab preset midway. (Clockwise rotation of the stab preset increases gain, excessive rotation may lead to instability). Set all the other presets anticlockwise to start off with. (Note LV60 models avf range is 25%). The preferred strategy for initial commissioning is in armature voltage feedback mode described as follows. Set Avf/Tach switch ON (left) for armature voltage feedback (Avf) and Spd x 2 switch OFF (right) for 40V max feedback. For systems utilising tach feedback, remove the terminal 11 tacho connection and temporarily make wire end safe until later. Check that the Power lamp lights. (Note, the Power lamp POWER ON intensity is reduced when the negative armature bridge is demanded). Increase the external speed pot slowly to maximum. The motor should slowly ramp up to around 40V on the motor armature. Now set the 100% armature voltage and hence speed by using the Spd x 2 switch (ON (left) for speed X 2) and the Max spd preset (Clockwise to increase speed). Note, if you change the Spd x 2 switch position whilst running, the speed will undergo an immediate step change.

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 3 RAMP and MIN SPEED The up / down ramps can now be set between 20 and 1 seconds, and the Min spd adjusted up to 30%. (Note, down ramp becomes up ramp for reverse rotation). IR COMP Speed droop on heavy loads may occur when armature voltage feedback is used. This is compensated for by clockwise rotation of IR comp. Excessive rotation may lead to instability. Note, IR comp is not used with tach feedback, leave preset anticlockwise. TACH FEEDBACK The tacho feedback signal on terminal 11 must be negative with respect to terminal 10 for a positive speed input. Whilst still in Avf mode measure the tach volts on the wire intended for T11 when running at 100% speed. (Warning, possible high voltage). This is the tach full speed voltage. Make a note of it to assist in selecting the speed range. Stop the motor and turn off the supply. Set Avf/Tach switch OFF (right). Adjust the Max spd preset anti-clockwise. (With Spd x 2 switch OFF (right) maximum speed range = 40 to 100V. With Spd x 2 switch ON (left) the maximum speed range = 80 to 200V). Re-connect the tach wire to T11, re-start and adjust Max spd as required. Do not use an AC rectified tacho for bi-directional systems. TERMINAL LISTING WARNING. A+, A-, F-, F+, N, L, are at high potential. DO NOT TOUCH the terminals or any connected conductor 1 +10V output. 10mA max. (Use a 10K Ohm pot for external speed reference). 2 MIN Speed. 5K Ohms preset to COM. (Connect to minimum end of speed pot). 3 IP. Speed input to ramp. 0 to +/-10V from speed pot wiper. 47K pull down. 4 OP+/-. (+/-10.5V range). 10mA max. T6 is the input for this function. Invert with pushbutton input T8 open. Non-invert with pushbutton input T7 open. (This function may be used to provide pushbutton controlled +/- 10V ref for fwd/rev). 5 COM. Common. (0 Volts) 6 IP+/-. Input to pushbutton controlled +/- signal channel. OP on T4. 50K Ohms. Note. This channel can invert input signals in the range +/-10.5V. It can also buffer (i.e. non-invert) signals in the range 0V to +10.5V. (It cannot buffer negative signals. If you try to buffer negative signals the output swings positive). 7 PB+ Pushbutton input. 47K Ohm pull up to +12V. Connect to T5 COM. Latches T4 to buffer (non-invert) positive T6 signals when opened, provided T8 PB- is connected to T5 COM. 8 PB- Pushbutton input. 47K Ohm pull up to +12V. Connect to T5 COM. Latches T4 to invert T6 when opened. T7 PB+ may be open or connected to T5 COM. 9 RUN. Internal 12K pull up to +12V. Open to stop, close to T5 COM to run. WARNING. RUN is an electronic inhibit function. The field remains energised, and all power terminals live. RUN must not be relied on to prevent rotation during hazardous operations. See section on STOPPING & JOGGING below. 10 COM. Common. (0 Volts) 11 TACH input. The tach must be opposite polarity to speed input. 1.5 MOhms. 12 RLOP. Relay driver. +10V active high at 10mA. Flywheel diode to COM. 13 RLIP. Relay driver input. Accepts 0 to +/-10.5V signal inputs. The threshold to activate the relay driver is symmetrical around zero, and set by the Level preset between +/-0.05V and +/-10.5V. When the T13 input exceeds the positive or negative threshold, then the T12 RLOP is turned ON. Typical uses include zero speed detector, zero current detector, stall detector etc. The input will accept any output from other control terminals. 50K Ohm pull down to COM. 14 OVLD. Overload. +10V active high at 10mA if the current demand exceeds 100%. Latches high if the stall timer eventually times out. 15 TRIP. Latched +10V active high at 10mA for either stall OR fan alarm tripped.

4 Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual 16 ROP. Ramp output. 0 to +/-10V output for 0 to +/-10V input. 1K Ohm output. 17 DEM. Demand output. 0 to -/+10V output for 0 to +/-100% speed demand. 1K Ohm output impedance. Represents the inverted total speed demand. 18 SOP. Speed output. 0 to +/-10V for 0 to +/-100%. 1K Ohm output impedance. 19 IOP. Current output. 0 to +/-5V output for 0 to +/-100% armature current. Maximum output +/-7.5V for +/-150% current. 1K Ohm output impedance. 20 SPD. Direct speed input fast response. Input impedance 100K. This signal is summed with the ramped reference. 0 to +/-10V input for 0 to +/-100%. 21 TRQ. Torque input. 100K Ohms pull up to +12V. 0 to +7.5V for 0 to +/-150% current (torque) demand. This input acts as an upper clamp on the current demand output produced by the speed loop. The current demand polarity determines the sign of the current. This input controls torque by clamping the demand amplitude. To operate, the total input speed demand must require current higher than this clamp level will allow. Conversely, if the speed loop current demand falls below this clamp level, the speed loop will regain control. A+ Motor armature + Form Factor typically 1.5 A- Motor armature - F- Motor Field (No connection required for permanent magnet motors). F+ Motor Field +(For half wave field volts 0.45 X AC, connect field to F- and N). N AC supply. 110V AC or 240V AC +/-10%, 50 60 Hz. (30/60VAC for type LV60) L AC supply. 110V AC or 240V AC +/-10%, 50 60 Hz. (30/60VAC for type LV60) Terminal tightening torques A+ A- F- F+ N L 4.4in lb - 0.50Nm Terminals 1 to 21 2.2in lb - 0.25Nm ALARMS Models ER-680XRi and ER-1220XRi use an internal fan for cooling. The Alarm lamp will come ON and the drive will electronically shut down if the internal fan fails. The field will remain energised, hence if the machine is to be left unattended for long periods it may cause the field to overheat. (T15 TRIP alarm output available). All models possess a STALL TIMER. This starts to integrate when the current demand exceeds 100%. A continuous demand of 150% will take 30 seconds to saturate the timer integrator, and latch the drive into shut down. Overload profiles at lower levels will take longer to trip. A STALL TRIP is indicated when the Stall lamp is latched on and the drive is shut down by the alarm. The LAMP gets progressively brighter as the stall integrator fills up prior to tripping. (T15 TRIP alarm output available and T14 OVLD also latches high). STOPPING & JOGGING For frequent stopping or jogging it is recommended to use the RUN input. When using a mains contactor, connect a spare Normally Open contact from the contactor in series with the RUN input. Do not simply remove the supply to stop the motor, especially if the system is regenerating. This may cause fuse blowing, and possibly damage if the regenerative energy cannot be dissipated due to supply removal. If the drive is running, open the RUN (T9) input at least 250mS before removing the supply to allow time for the current to be quenched by the drive.

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 5 MECHANICAL DETAILS The product is enclosed in a stylish DIN rail mounted enclosure with plug in screw terminal connections. Lift up cover Sw1 AVF Sw2 Spd x 2 Stall lamp Increasing brightness for imminent trip. Comparator Level preset Alarm lamp Max Speed Min Speed Up Ramp Down Ramp Fan exhaust For models ER-680 / ER- 1220XRi A+ A- F- F+ N L Supply Select DIN rail release catch with bottom rear access slot. (Unplug terminals to gain access) Max Current Stability Power ON lamp Brighter for positive current. IR Comp Terminals 1 to 11 Terminals 12 to 21 Height Width Depth ER-340XRi 105 60 120 ER-680XRi 105 70 120 ER-1220XRi 105 70 120 For Forward / Reverse operation Move the wire from T1 into T4. Connect T1 to T6. The pushbutton inputs T7/8 can then be used for direction control. Basic single direction speed control with tach feedback 1 2 3 5 9 10 11 A+ A- F- F+ 10K Pot RUN Earth Tach Armature Field Earthing A clean signal earth connection should be made to terminal 10 (Common). The motor earth should be connected to the earth in the system enclosure. APPLICATIONS GUIDE If the unit is to be used in the domestic environment, then for installations in the EU a supply filter is recommended in order to comply with EN6800-3. Eurotherm part number FRLN16. For EU EMC compliance guidelines refer to the above website. WARNINGS Health and safety at work. Electrical devices constitute a safety hazard. It is the responsibility of the user to ensure compliance with any acts or bylaws in force. Only skilled persons should install this equipment. Eurotherm Ltd. does not accept any liability whatsoever for the installation, fitness for purpose or application of its products. It is the users responsibility to ensure the unit is correctly used and installed. http://www.eurotherm.com