SPORTS: Football pitch for class III Customer : Processed by : Siteco Light Consulting Project description: Maintenance factor 0,8 Football field 105 x 68m 4-mast-layout Mast height 16m 2 floodlights per mast Inclination 10 The determination of the lighting results is performed on a sales support basis, with great thoroughness, using the documents at our disposal and with the aid of calculating procedures customary in the market (e.g. Relux, Dialux). A guarantee / warranty / liability for this free calculation is not provided by SITECO. In this respect, we refer to the services of the light planning and engineering office. The following values are based on exact calculations on calibrated lamps, luminaires and their arrangement. In practice, gradual divergences can occur. Guarantee claims for luminaire data are excluded. Relux and the luminaire manufacturers accept no liability for consequential damage and damage which is occasioned to the user or to third parties. Page 1/8
Table of contents First Page 1 Table of contents 2 1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS03) 1.1.1 Data sheet 3 2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan 4 2.1.2 3D view, View 1 5 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field 6 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) 7 2.3.2 3D luminance, View 1 8 Page 2/8
1 Luminaire data 1.1 Siteco, SiCOMPACT A3 MAXI (5NA76901WS03) 1.1.1 Data sheet Manufacturer: Siteco 5NA76901WS03 floodlight-pylon top SiCOMPACT A3 MAXI SiCOMPACT A3 MAXI, floodlight, primary light control with reflector, of aluminium, hammer dimple, primary optical cover: cover panel, of toughened safety glass, light emission: direct distribution, primary light characteristic: asymmetric, installation type: surface-mounted, for 1 x HIT-DE l=274 2000W, superimposed pulse ignitor, internal, control gear: without control gear, with terminal, 3-pole, max. 2.5mm², mains connection: 400V, AC, 50Hz, luminaire housing, of diecast aluminium, sandblasted, natural, mounting bracket, of steel, galvanised, protection rating (complete): IP65, insulation class (complete): insulation class I (protective earthing), certification: CE, impact resistance: IK08, standard: EN 50419, packaging unit: 1 piece, Luminaire data Luminaire efficiency : 80.1% Luminaire efficacy : 87.73 lm/w Classification : A20 100.0% 0.0% CIE Flux Codes : 27 66 97 100 80 UGR 4H 8H (20%, 50%, 70%) C0 / C90 : 46.5 / 32.8 Control gear : LLCG System power : 2100 W Length : 709 mm Width : 581 mm Height : 225 mm Equipped with Quantity : 1 Designation : HIT-DE-h15 2000W/854 (OSRAM) Power : 2000W Colour : Luminous flux : 230000 lm Page 3/8
2 Football pitch 75 lux 2.1 Description, Football pitch 75 lux 2.1.1 Floor plan [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] 1 : 1000 Page 4/8
2.1 Description, Football pitch 75 lux 2.1.2 3D view, View 1 Page 5/8
2 Football pitch 75 lux 2.2 Summary, Football pitch 75 lux 2.2.1 Result overview, Football field [m] 40 N 30 20 10 0-10 -20-30 -40-60 -50-40 -30-20 -10 0 10 20 30 40 50 60 [m] Illuminance [lx] 50 75 100 150 200 General Calculation algorithm used Direct component Height of evaluation surface 0.00 m Maintenance factor 0.80 Total luminous flux of all lamps Total power Total power per area (9600.00 m²) 1840000 lm 16800 W 1.75 W/m² Illuminance Average illuminance Eav 103 lx Minimum illuminance Emin 64 lx Maximum illuminance Emax 189 lx Uniformity Uo Emin/Em 1:1.62 (0.62) Diversity Ud Emin/Emax 1:2.97 (0.34) Type No.\Make Siteco 1 8 Order No. : 5NA76901WS03 Luminaire name : SiCOMPACT A3 MAXI Equipment : 1 x HIT-DE-h15 2000W/854 (OSRAM) 2000W / 230000 lm Page 6/8
2 Football pitch 75 lux 2.3 Calculation results, Football pitch 75 lux 2.3.1 Table, Football field (E) [m] 60 71 97 134 148 160 152 148 117 96 86 83 86 95 116 147 152 162 148 133 97 71 84 100 120 164 188 176 135 120 112 108 106 108 112 120 134 176 [189] 164 119 100 84 55 87 97 113 140 143 148 131 117 117 115 114 115 117 117 130 147 143 140 113 96 86 50 45 40 35 30 25 20 15 10 5 0 83 94 107 110 107 114 121 116 114 112 111 112 114 116 120 114 107 109 106 93 83 76 87 94 89 84 93 106 109 107 105 105 105 106 108 106 93 85 89 93 87 76 70 78 81 76 71 80 93 99 98 98 98 98 98 98 92 80 72 76 81 78 70 65 71 72 68 66 72 83 90 93 93 93 93 93 90 83 72 66 68 72 71 65 (64) 69 69 66 (64) 70 80 87 91 92 91 92 91 87 80 70 (64) 66 68 69 (64) 65 71 72 68 66 72 83 90 93 93 93 93 93 90 83 72 66 68 72 71 65 70 78 81 76 72 80 92 98 98 98 98 98 98 99 93 80 71 76 81 78 70 76 87 94 89 85 93 106 108 106 105 105 105 107 109 106 93 84 89 94 87 76 83 93 107 110 107 114 120 116 114 112 111 112 114 116 121 114 107 110 107 94 83 86 96 113 140 143 147 130 117 117 115 114 115 117 117 131 148 143 140 113 97 87 84 100 119 164 [189] 176 134 120 112 108 106 108 112 120 135 176 188 164 120 100 84 71 97 133 148 162 152 147 116 95 86 83 86 96 117 148 152 160 148 134 97 72 0 10 20 30 40 50 60 70 80 90 100 [m] Illuminance [lx] Height of the reference plane : 0.00 m Average illuminance Eav : 103 lx Minimum illuminance Emin : 64 lx Maximum illuminance Emax : 189 lx Uniformity Uo Emin/Eav : 1 : 1.62 (0.62) Diversity Ud Emin/Emax : 1 : 2.97 (0.34) Page 7/8
2.3 Calculation results, Football pitch 75 lux 2.3.2 3D luminance, View 1 Luminance in the scene Minimum: Maximum: : 0 cd/m² : 16.9 cd/m² Page 8/8