NEW CONCEPT FOR MEDIUM VOLTAGE GAS INSULATED SWITCHGEAR (GIS) by LJ Fleischer, Siemens Electricity + Control May 1999

Similar documents
NXPLUS C Single busbar. Maintenance-free for lifetime

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

B kv T&D GAS INSULATED SWITCHGEAR

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

8DJ. Maintenance-free for lifetime

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

SIMOBREAKER The New Substation with Rotary Disconnector Fully Assembled, Compact and with High Availability

B kv Gas-insulated Substations

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

ZX2.2 Gas-insulated medium voltage switchgear

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Retrofit for gas-insulated high voltage switchgear (GIS) - 8D1 and 8D2

Gas-insulated switchgear up to 420 kv, 63 ka, 5000 A Type 8DQ1. siemens.com/energy. Answers for energy.

EMPAC Metal enclosed capacitor bank for wind applications

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

Gas Insulated Metal-clad Switchgear, HMGS!

HIS Highly Integrated Switchgear up to 145 kv

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

ZX-Family Gas-insulated medium voltage switchgear

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Gas Insulated Switchgear

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

ZX2 Gas-insulated medium voltage switchgear

the safe, reliable, and efficient choice for MV switchgear

3AP1 DTC for 145 and 245 kv

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

PASS M0. Innovative solutions for distribution substations up to 170 kv

123/145kV SF6 Gas-Insulated Switchgear incorporating VCB. 145kV-1250~2000A-31.5kA

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

FUSES. Safety through quality

Gas-Insulated Switchgear up to 145 kv, 40 ka, 3150 A Type 8DN8. Power Transmission and Distribution

Independent Testing Laboratory for High Voltage Equipment

HIS Highly Integrated Switchgear up to 550 kv, 63 ka, 5000 A Type 8DQ1

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

CPG.0 Single busbar gas-insulated cubicles

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Gas Insulated Switchgear ELK-0. for stations up to 170 kv, 4000 A, 63 ka

Power Transmission and Distribution. HIS Highly Integrated Switchgear up to 550 kv. Type 8DQ1

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Gas-insulated switchgear from 72.5 to 550 kv. Excellent systems that create lasting value. siemens.com/energy-management

GAS INSULATED VOLTAGE TRANSFORMERS.

Gas-Insulated Switchgear up to 245 kv, 50 ka, 3150 A Type 8DN9. Power Transmission and Distribution

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Distribution transformers Efficiency over life-cycle

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

Product guide. Enclosed NEMA starters. Answers for industry.

Product brochure. Gas-insulated switchgear ELK-04 C, 145 kv Modular and reliable

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

Innovac SVS/08 - SVS/ kv modular switchgear

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Gas-Insulated Switchgear up to 145 kv, 40 ka, 3150 A Type 8DN8. Answers for energy.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

voltage switchgear ZX ABB ZX Family 1

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Metal Clad Air Insulated Switchgear

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Air-insulated switchgear UniGear type ZS1

CABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

UniSec Maintenance solutions

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Benefits, typical uses

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Compact Gas Insulated Switchgear (GIS) up to 145kV 126kV,145kV Compact Gas Insulated Switchgear (GIS)

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

Key features. DESIGNS: - Conservator type - Hermetically sealed

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

ZX-Family Gas-insulated medium voltage switchgear

Power Transmission and Distribution. NXPLUS C double busbar. The economical solution when replacing old systems

SWITCHBOARDS (LV and MV)

MEDIUM VOLTAGE SWITCHGEAR

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Product Guide. enclosed NEMA STARTERS

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

Raising the bar. UHV switchgear and components

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Transcription:

NEW CONCEPT FOR MEDIUM VOLTAGE GAS INSULATED SWITCHGEAR (GIS) by LJ Fleischer, Siemens Electricity + Control May 1999 This article describes a new series of medium voltage gas insulated switches suitable for use in MV energy supply systems. It was introduced to the market in 1995 and is designed, just as the vacuum circuit breaker which it uses, to be maintenance-free for its lifetime. Its use will increase the reliability, simplify and reduce the costs of operation in public and industrial networks. This new series, type 8DC, is available with single busbars for rated voltages up to 24 kv, short circuit interruption currents up to 25 kv and rated currents up to 1 250 A. All the most common circuit arrangements are provided. Its operation demands no particular expertise or abnormal procedures. Historical steps towards total freedom from maintenance in circuit breaker switchgear. Gas-filled switchgear with maintenance-free HV sections Nearly 20 years ago, in 1982, the first gas insulated medium voltage switchboard with vacuum circuit breakers was introduced [1]. Compared with air insulated equipment, it had significant advantages: hermetic encapsulation of all live parts in SF6 gas filled enclosures total exclusion of any influence on the HV parts from pollution, moisture and condensation or small living creatures no oxidation of contacts or connections no hardening of lubricants secondary windings or current transformers totally separated from HV parts drive mechanisms accessible at all times The high voltage parts of this concept are fully maintenance-free but the joints between individual chambers and the mechanical and electrical entries into the chambers are sealed with O-rings and the possibility of a certain leakage rate has to be accepted. The gas pressure is therefore monitored and it is recommended that the gas pressure and quality be checked every 10 years. This is the same interval as for regreasing the drive mechanisms of the circuit breaker. Further maintenance is not required. Operational experience with this concept is extremely good, confirmed by its commercial success. More than 18000 bay-units are in operation throughout the world. Based on the definition of major failures (CIGRE 'Reliability of HV circuit breakers') these units have so far achieved an MTBF of more than 10000 years. This equipment is now available with ratings of up to 40.5 kv, 40 ka and 3 l50a and is looked upon as state of the art technology for the upper range of distribution applications. Ring main units with seam-welded containers which eliminate the gas maintenance In 1983 the author's company introduced a ring main unit with switches sealed -without any gaskets - into a seam-welded chrome-nickel-steel container. This unit was designed for the many thousands of secondary network substations and is totally maintenance-free: neither the gasfilling nor the drives can or need to be serviced. This concept has also proved to be correct and the use of this unit is widespread.

Vacuum circuit breakers without need for servicing - not even the mechanism. Seven years ago, in 1992, the fully maintenance-free vacuum circuit breaker was introduced [3]. Due to the right combination of material and special lubricant even the drive mechanism became maintenance-free for its lifetime. This new circuit breaker 3AH completed the list of components necessary for maintenance-free switchgear. The development of GIS Given these basic components, we were able to introduce, in 1993, a maintenance- free switchboard with line-up circuit breaker and switch disconnector cubicles for currents up to 630 A, with the identification code XDH. This concept has been extended in the switchboard type 8DC, with circuit breakers up to 1 250 A and improved features. These new switchboards embody the best characteristics of the previous steps and combine the highest reliability for all operating conditions with freedom from maintenance for life. What does maintenance-free mean? Preventative maintenance is that activity which is carried out in accordance with a plan, or after particular occurrences. It comprises: lubrication fill level checks filter changes Operation dependent items (number of operations, total switched current): contact check and replacement renewing of arc quenching medium Environment dependent items: cleaning corrosion protection renewal The necessity for these measures cannot be determined remotely. Thus, planned maintenance has previously required that installations be regularly visited and serviced by trained personnel Even the preparatory switching procedures are often extensive and inconvenient to customers. All too often experience has shown that human interference has sown the seeds of future failure. With planned maintenance, one comes into conflict with the, 'if it works don't fix it' principle. A system designed for no maintenance thus avoids: implementation and monitoring of the planned maintenance schedule employment of maintenance personnel stocking of consumable or replacement parts switching procedures and network disturbance faults caused by maintenance errors This guarantees the highest reliability with minimum cost. Freedom from maintenance cannot, however, guarantee that every possibility of fault is excluded, so designs must also ensure that unavoidable faults can be quickly and simply overcome. 8DC switchgear is, therefore, so constructed that many important components are accessible whilst the circuit is in operation, for example: circuit breaker drive mechanism selector switch drive mechanism secondary connections While the busbar is live: current transformers voltage transformers cable terminations

Design requirements Figure 1. Maintenance-free GIS, type 8DC; section view of circuit rated temperatures. To create a truly maintenance-free design, particular requirements must be met and special features must be provided. We examine what can be done, using 8DC as an example (Figure 1): Whilst the pressure stress on the parts of the housing may change, it can never reverse. This significantly minimises stress and increases reliability. Gas is filled after evacuation. In trust in the reliability of the concept, the careful manufacture and quality control, the filling nozzles are pinch-welded after filling is complete. Nevertheless, an operator can convince himself of the condition before each switching operation: each cubicle has a gas density indicator with a clear, temperature independent display. This indicator has been well-proven in the gas insulated ring main unit 8DJ [2]. Expansion and contraction of a reference volume is transferred magnetically through the container wall without any need for penetration. To absorb original enclosed moisture from the components, desiccant bags are fitted in each container? Once in operation however, no significant quantity of moisture can enter the container and desiccant renewal is unnecessary. Features of the conductor entries Each cubicle and thus each container has at least six high voltage conductor entries (bushings), three for the busbar and three for the cable connections. These are of the external cone type in accordance with CEN HD 50631. Every high voltage bushing is subject to thorough routine, partial discharge, X-ray and gas-tightness tests before welding in. Each bushing has an integral control electrode in the flange surround. Its connection is brought out. Thus each bushing can be used as part of a voltage indicating system. Plug-in cable connectors of the external cone system can be plugged directly onto the cable bushings, also for two or three cables per phase, in tandem. These cable connectors also allow direct connection of surge arresters or cable test equipment. Features of the components The principles of the vacuum circuit breaker are described in [3]. The circuit breaker is developed out of the known series 3AH. This circuit breaker is maintenance-free for life and can be safely welded, totally gastight into the sealed unit. Due to the arrangement of the drive mechanism to the vacuum tubes, there is only a linear movement inside the gas container. Complicated linkages are unnecessary. The circuit breaker is constructed as a module whose mechanical and electrical behaviour can be tested before welding in. A three-position selector with the positions ON, OFF and EARTH serves for disconnection and preparation for earthing. Each selector has two drive shafts, one for disconnection, and one for earthing. Both operate a shaft which is concentric with the selector fulcrum. Within the container, no other rods or linkages

are necessary. Neither lever can be inserted whilst the circuit breaker is closed. Between the drives of the Figure 2. Busbar joints - sectional view. breaker and the selector there is an interrogate interlock. To earth the cable connections, the selector is switched to earth and the circuit breaker must be closed, either manually or automatically. Current transformer secondary windings are always fined outside the containers, in areas of single pole accessibility, for example at the points of transfer to the cable connections or busbars. The transformer secondaries are thus isolated from voltage stresses and undesirable thermal influences of the primary current. Voltage transformers are excluded from the interior of the enclosures because they are always subject to electrical stress. In 8DC, two solutions are used: In a feeder circuit, fully insulated, metal enclosed inductive voltage transformers are plugged in from the outside. Within the container, connection is made, through a disconnect switch which is operated from the outside via a gas-tight metal bellows. This allows testing of the switchboard with ac and the cables with dc without having to remove the VT. On the busbars, the fully insulated, metal enclosed vts are plugged onto the cross pieces of the busbar connections. A separate measuring cubicle is unnecessary. The windings and the core of these vts are electrically and magnetically so constructed that the switchboard can be voltage tested without damaging them. This applies to on-site tests at 80% of the rated power frequency withstand voltage. Both solutions are extremely reliable, fulfil operator requirements and, even in the event of fault, hardly affect the switchboard. The busbars of round copper are outside the containers, as seen in Figure 2. They are arranged as cubicle-module assemblies, single pole, for attachment to the busbar bushings on each container. Thus any required cubicle combination can be constructed, altered or extended without gas-working or entry into the containers. Tolerances and expansion or contraction are compensated in the joint cross pieces. The cross pieces and the bars are insulated with high quality, generously dimensioned silicon rubber All external surfaces are conductively coated and earthed. Additionally, they are totally enclosed. The insulation of the bars is thus completely protected against the external influences of climate, pollution and condensation. Altitude-related derating is avoided. The proven, long-life quality of the silicon rubber used guarantees appropriate insulation capability for the life of the equipment. Features of quality Reliability, especially for life and without any maintenance, stands or falls with the quality in all respects. In a long-term business, quality demands as set by the user and by the ideals of a responsible manufacturer, are decisive for trust and continuous success. Total quality management is set out and certified through a QM handbook to ISO9001. This handbook records a wealth of procedural data. In the procurement of materials and safety-relevant parts or assemblies, special quality control agreements are made which comply with those procedures. The quality of the concept and the design can be seen from the foregoing description. The quality of testing rests on the long experience of in-house, optimally equipped testing laboratories, accredited to EN 45001. Here the characteristics of the switchgear have been tested and documented to the requirements of the standards and beyond. Quality of manufacture is in the interest of the manufacturer just as much as the user, In a fully welded construction, any fault which is first discovered in final test or during operation, has serious consequences. This concept, therefore, demands manufacture to the highest quality at every stage. Consequently there is

a comprehensive production control check for each stand-alone assembly, individually documented in the References [1] Lübben W. Prohl R. 'SF6 insulated-switchgear with vacuum circuit breakers'. Siemens Energy and Automation Magazine, Special Supplement, 1998 [2] Algermissen W, Lübben W, Kübler B. 'SF6-insulated ring main units. A technology for the substations of tomorrow'. (German Text). [3] Berger F,. Boulter R, Vester M. 'Maintenance-free vacuum circuit breaker'. IEE Conference: 'Reliability of transmission and distribution equipment'. University of Warwick, UK, March 1995. [4] Fleischer L, Hartmann E. 'Extension of use of the maintenance-free VCB into the medium voltage GIS concept'. IEE Conference: 'Reliability of transmission and distribution equipment', University of Warwick, UK. March 1995. quality record book. It is more important though, that the production team fully understand the importance of the care of their workmanship and its effect on the satisfaction of the user, the success of the company and their own well-being. Regular training, appropriate facilities and incentives guarantee this motivation. Quality of final test is the last step. It must and does rigorously detect every defect. Correction before dispatch or - when necessary - scrapping and replacement are essential, even when it costs time and money. Life expectancy Thirty years was set as the design life, because a commitment to a longer time would be speculative. The gas filling of the enclosure and, therefore the integrity of its insulation - with today's materials, manufacture and test procedures - is theoretically good for about 1 600 years. Regarding the life of the silicon rubber insulation, some 25 years experience is available (even as outdoor equipment for high voltage). Under the given conditions of use: protected from mechanical damage by metal enclosure protected from direct effect of sun, rain or snow protected from surface discharge by dielectric, earthed screen field intensity in the insulation material only a fraction of the breakdown strength With reliable certainty, a life of more than 30 years can be expected. Cast resin components, for example insulators and bushings - have been manufactured since 1958 practically without alteration and have impressively proven their durability in this time. In view of the expected length of life, the three position selectors and their drives are designed for a significantly higher number of operations (2000 cycles) and lubricated for this number and for a lifetime of more than 30 years, circuit breakers for 10 000 operations and more than 30 years [3]. With the advent of this lifelong maintenance-free switchgear, type 8DC, a breakthrough towards highest reliability with lowest operating cost has been achieved. Better planning of asset replacement and confidence in the reliability of supply should result from this concept. At the end of its useful life, the safe disposal of any equipment should be possible. With 8DC, there is no problem. The insulating gas is unpolluted - because switching takes place in vacuum it can be extracted and prepared for re-use. The metallic parts are not contaminated and are therefore valuable scrap. All other parts, whose material may cause doubts, are identified and easily disposable.