Compatible Inverters for FS2 and FS3 Series Modules With Galvanic Isolation

Similar documents
Compatible Inverters for FS2 and FS3 Series Modules Without Galvanic Isolation

COMPATIBLE INVERTERS. Table of Contents

PHOTOVOLTAICS IN THE SMART GRID

Support the grid, defy the weather

Stock clearance price-list Inverters February 2019

Stock clearance price-list Inverters April 2019

Inverters and panels price-list SOLAR DISTRIBUTION August 2018

Planning and project development ... Turn-key solar power stations. References ... Business management / Consultancy ...

SCE UL 1741 SA with Reactive Power Priority Inverter List (Simplified Data) Data has not changed since August 10, 2018

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

Price list - Inverter

There are currently no new, groundbreaking

Goodbye to the transformer

Watch out, SMA. science & technology. When a company like Chinese-based Huawei

Meeting point for experts. Exhibit in front of the exhibition halls: A Solar-Tracker welcomes the visitors of the Intersolar 2005.

Distribution division. Solar Photovoltaic Catalogue. Premier Plaan. Smart solutions for the solar energy sector around the world

As the precious metal prices hit new highs, cell makers suffer from increasing metallization costs

OFFPRINT: Huawei. June

Inverters. Inverters. System Design

magellan solar export control solutions Magellan Power Solar Gate

MAXIMIZING THE POWER OF RENEWABLES

[RENEX] [İstanbul, Ekim 2011]

ABB central inverters ULTRA-750/1100/ kW to 1560kW

COMPANY PRESENTATION

Yield Reduction Due to Shading:

Summary. Germany. Product. Australia U.S RESU 3.3 RESU 6.5 RESU 10 RESU 7H RESU 10H 1/8

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Problema Inverter Power One 3.6 Outdoor >>>CLICK HERE<<<

Jorge Álvarez, PM Solar, Abril 15 th - Santiago. ABB Solar Central lnverters (PMGD)

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

Standard-compliant components for commercial photovoltaic applications

Hardware Testing of Photovoltaic Inverter Loss of Mains Protection Performance

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Total number of PV modules: 42 Energy usability factor: 99.9 % Number of PV inverters: 1

GEatom 306KHF-wall 5.7 3N~ <3% >93.5 Battery

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

magellan solar export control solutions Magellan Power Solar Gate

Current Automation Catalogue Page 245

PRODUCT LIST ORDER:

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

ORDER:

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

Orion New Zealand Limited. Small Distributed Generation Systems. Information Pack for Small System (10kW or less) Connections

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

Yield vs simulation of Canadian Solar modules October 2012 QUALITY I VALUE I INNOVATION

Optimized parameter settings of reactive power Q(V) control by Photovoltaic inverter Outcomes and Results of the TIPI-GRID TA Project

COMPANY INTRODUCTION COMPANY MISSION COMPANY VISION

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

Energy Produced by PV Array (AC):

Residential Energy Storage System SH5K PV ESS

CONERGY CIS 1200 Manufactured By Bosch

IEEE Workshop Microgrids

The modular energy storage system for a reliable power supply

220Volt 10Watt LED FLOODLIGHT R Volt 20Watt LED FLOODLIGHT R Volt 30Watt LED FLOODLIGHT R

AIR CYLINDER Series A75, A76

Current Automation Catalogue Page 1

December 15, 2009 thru December 14, 2014 Meridian 27 kw Project : Austin Bergstrom International Airport Austin, TX

REFU Company presentation

photovoltaikforum.com

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

SP PRO KACO Managed AC Coupling

SUN INGECON. Box 220 / 275 / 300 / 320 / 345 / 360 Vac. M220 / M275 / M300 / M320 / M345 / M360 Outdoor.

Hedeager Aarhus N Denmark. Vestas V110-2 MW 50 Hz VCS Mk 10

BYD. ENGINEERED FOR LIMITLESS POSSIBILITIES AUTHORISED DISTRIBUTOR FOR BYD

Residential Energy Storage System PowCube 4.8

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

FusionSolar Smart PV Solution. Exceed your profit targets through Digitalization Networking Higher Yields. FusionSolar

BYD Battery-Box LV Installation Guidance

SOLAR ENERGY SYSTEMS. PV Energy Systems & Solar Thermal Systems

IES GRID FEED-IN LIMITER

SMA FLEXIBLE STORAGE SYSTEMS. SMA Solar Technology AG

Product information Electronic devices. Typ: CONV DIN. Converter for Pt-sensor as KTY-alternative. Pt / KTY Converter

Why array oversizing makes financial sense

: Function of Components. Fronius Sattledt

OPTIMIZATION OF DC PLANT TOPOLOGY USING AE 1000NX INVERTERS

SolarMax 20C/25C/30C/35C. Proven reliability.

Renewable Energy/ Energy Efficiency

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

BYD BATTERY-BOX THE BATTERY FOR ALL APPLICATIONS

Renewable Energy. Energy Storage PV ebop

Recap of this Builder Group s Requests

MELT PRESSURE TRANSMITTERS K7 SERIES PERFORMANCE LEVEL c

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

Installation. Products for private- and business clients

PowerRouter Solar Battery Self-use

Power Electronics for DC Grids

Please note the inverter supplied with your solar system is AS4777 accredited.

INVERTER. MECHANICAL DATA Steel with powder paint Dimension (mm) 527 x 228 x 190 Net Weight (kgs) 18 STANDAR. Cont output power at 20ºC. Cos φ 0.

Solutions. for large buildings and power plants

GOVERNMENT OF PUERTO RICO PUERTO RICO ENERGY AFFAIRS ADMINISTRATION. Tier 2 GET Reference Guide

BYD Battery-Box LV Compatible Inverter List Battery-Box L 3.5/7.0/10.5/14.0

The sun as power station

DC and AC coupling: which one is the best solution?

Solar inverters from Delta The heart of your PV system

SA Power Networks Commissioning Witnessing Checklist

Innovative solutions for integration of distributed renewable generation

Advanced Inverter Trends and Distributed Energy Resource Standards IEEE PES SF Chapter Presentation

Transcription:

Compatible Inverters for FS2 and FS3 Series Modules With Galvanic Isolation This document provides a list of inverters that are compatible and approved for the usage with the First Solar FS Series 2 and FS Series 3 Modules. This list does not provide performance evaluations or comparisons between inverters and does not recommend a specific inverter manufacturer. Absence from the list does not indicate that there is an incompatibility with an inverter, only that First Solar has not completed the verification of the inverter. First Solar warrants its FS Series 2 & 3 modules according to the First Solar Module Warranty Terms & Conditions (PD-5-102, Module Warranty Terms & Conditions ) provided modules are installed, operated and serviced as described in the First Solar User Guide (PD-5-200, User Guide ) and in the System Design and Application document (PD-2-303, SDA ). First Solar requires all system designs to be submitted for review and approval via the SDA process; therefore, for warranty purposes, every system with First Solar modules must be covered by an SDA. Project Developers and\or Customers should request this document from First Solar and obtain approval prior to equipment procurement and installation. Approval of the following listed inverters is based upon and in accordance with the inverter datasheet effective at the time of evaluation. Thus, changes in inverter specification after First Solar approval may nullify the confirmation of compatibility. First Solar reserves the right to change the approval requirements for the inverter as well as a possible revocation of the inverter approval list. www.firstsolar.com PD-5-332_Inverter list - safe use_level 5 Page 1 of 23

List of Compatible Inverters without Galvanic Isolation 1,2,3 Manufacturer Series Name Type VOC Max Comments Series 2 Series 3 ABB PVS800 57-0100kW-A 900 with 57-0250kW-A 900 with 57-0500kW-A 900 with Advanced Energy PV Powered AE Solaron 333 1,000 This system is a BiPolar system putting 8 modules in series on both the Positive and Negative side. PVP 35kW 600 6 9 PVP 50kW 600 6 9 Solaron AE 500 750 7 11 AMK Antriebs- und Steuerungstechnik GmbH & Co. KG AMKASYN S 100-WT 1,000 S 88-WT 1,000 Answer Drives S.r.l. Solargate PV7L 800 8 12 PV7M 800 with 8 12 PV8L 900 PV8M 900 with Aros Sirio 125k 800 8 12 125K-HV 880 13 16k 800 8 12 20k 800 8 12 30k 800 8 12 K100 800 8 12 K100 HV 880 13 1 First Solar FS Series 2&3 PV Modules have no exposed conductive surfaces and do not require equipment grounding as long as a clip length of 100mm for a standard 4 clip mounting is not exceeded. 2 Calculation for maximum number of modules in series is based on -10 C cell temperature and 700W/m² irradiation. 3 Transformer Yes means that an internal or an is mandatory for the inverter www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 2 of 23

K12 800 8 12 K250 800 8 12 K40 800 8 12 K40 HV 880 13 K80 800 8 12 K80 HV 880 13 Beijing Corona Science & Technology Co., Ltd. KNGI900 500HEA 900 with Bonfiglioli Vectron RPS 450 120 900 170 900 30 900 60 900 RPS TL 0280 900 with 0310 900 with 0340 900 with 0380 900 with 0420 (1000V option) 1,000 with 0470 900 with 0510 900 with 0570 900 wit 0620 (1000V option) 1,000 with 0680 900 with 0760 900 with 0830 (1000V option) 1,000 with externel transformer 0850 900 wit 0940 900 wit 1040 (1000V option) 1,000 with 1110 900 with 1220 (1000V option) 1,000 with 1460 (1000V option) 1,000 with 0450 1,000 with external transformer/approval only for FS Series 3 15 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 3 of 23

0685 1,000 with external transformer/approval only for FS Series 3 0900 1,000 with external transformer/approval only for FS Series 3 1130 1,000 with external transformer/approval only for FS Series 3 1360 1,000 with external transformer/approval only for FS Series 3 1580 1,000 with external transformer/approval only for FS Series 3 15 15 15 15 15 Conergy AG Conergy Central 30 800 8 12 40 800 8 12 50 800 8 12 IPG C 200 C 1,000 with external MV-transformer 300 C 1,000 with external MV-transformer IPG K 110K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory 280K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory 300K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory 40K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory 60K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory 80K 1,000 Conergy Smart Connect for max. system voltage of 1000V is mandatory Sun Profi SP1300 450 4 6 SP2500 450 4 6 SP3100 450 4 6 SP3400 600 6 9 CONVERTEAM SAS ConverSOL 1000AI 900 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 4 of 23

1275LI 1,200 10 14 1500LI 1,200 10 14 1700LI 1,200 10 14 425 LI 1,200 10 14 500 AI 900 670AI 900 850LI 1,200 10 14 PSC 430MV - L - QC 1,000 500MV - L - QC 1,000 Danfoss Solar Inverters A/S ULX 1800 550 5 8 3000 550 5 8 3600 550 5 8 5400 550 5 8 Delta Energy Systems CI 100 900 SI 2000 540 5 8 2500 540 5 8 3300 540 5 8 5000 540 5 8 Solivia 2.5 540 5 8 3.0 540 5 8 3.3 540 5 8 5.0 540 5 8 CM 100 900 CM 77 900 CM 88 900 CS 44 900 CS 55 900 CS 66 900 Diehl Ako Stiftung & Co. KG Platinum 100CS 900 2100S 480 4 7 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 5 of 23

2800S 780 7 11 3100S 780 7 11 3800S 780 7 11 4300S 780 7 11 4600S 780 7 11 4601S 580 with external transformer/approval only for FS Series 3 8 Elettronica Santerno Sunway M Plus M Plus 1300 E 600 6 9 M Plus 2600 E 600 6 9 M Plus 3600 600 6 9 M Plus 3600 E 600 6 9 M Plus 4300 600 6 9 M Plus 4300 E 600 6 9 M Plus 5300 600 6 9 M Plus 6000 600 6 9 M Plus 6400 600 6 9 M Plus 7500 600 6 9 M Plus 7800 600 6 9 Sunway TG 1000V TE TG 750 1000V TE 1,000 with Sunway TG 600V TG 110 600V 740 7 11 TG 135 600V 740 7 11 TG 14 600V 740 7 11 TG 19 600V 740 7 11 TG 26 600V 740 7 11 TG 30 600V 740 7 11 TG 37 600V 740 7 11 TG 42 600 740 7 11 TG 61 600 740 7 11 TG 90 600V 740 7 11 Sunway TG 600V TE TG 180 600V TE 740 with 7 11 TG 230 600V TE 740 with 7 11 TG 280 600V TE 740 with 7 11 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 6 of 23

TG 290 600V TE 740 with 7 11 TG 365 600V TE 740 with 7 11 TG 455 600V TE 740 with 7 11 TG 550 600V TE 740 with 7 11 Sunway TG 800V TG 120 800V 880 8 13 TG 145 800V 880 8 13 TG 35 800V 880 8 13 TG 49 800V 880 8 13 TG 57 800V 880 8 13 TG 82 800V 880 8 13 Sunway TG 800V TE TG 175 800V TE 880 with 8 13 TG 240 800V TE 880 with 8 13 TG 300 800V TE 880 with 8 13 TG 310 800V TE 880 with 8 13 TG 385 800V TE 880 with 8 13 TG 485 800V TE 880 with 8 13 TG 610 800V TE 880 with 8 13 TG 730 800V TE 880 with 8 13 Eltek Valere THEIA 100kW 900 2.0 HE-t 600 6 9 2.9 HE-t 600 6 9 20kW 900 3.8 HE-t 600 6 9 30kW 900 4.4 HE-t 600 6 9 50kW 900 THEIA TL 150kW 900 with external MV transformer 200kW 900 with external MV transformer 250kW 900 with external MV transformer 350kW 900 with external MV transformer 500kW 900 with external MV transformer 500KW with EIV Kit 950 with external MV transformer 9 14 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 7 of 23

Elvi_Universal QCC 100k 800 8 12 30k 800 8 12 55k 800 8 12 Emerson SSL 0100 1,000 with 0250 1,000 with extrenal transformer 0500 1,000 with 1000 1,000 with FRIEM S.p.A. RECon 30H-150 900 with 30H-150-T 900 30H-300 900 with 30H-300-T 900 30H-450 900 with 30H-450-T 900 30H-600 900 with 30H-600-T 900 30L-100 700 with 7 10 30L-100-T 700 7 10 30L-200 700 with 7 10 30L-200-T 700 7 10 30L-300 700 with 7 10 30L-300-T 700 7 10 30L-400 700 with 7 10 30L-400-T 700 7 10 60H-1200 900 with 60H-1200-T 900 60H-300 900 with 60H-300-T 900 60H-600 900 with 60H-600-T 900 60H-900 900 with 60H-900-T 900 60L-200 700 with 7 10 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 8 of 23

60L-200-T 700 7 10 60L-400 700 with 7 10 60L-400-T 700 7 10 60L-600 700 with 7 10 60L-600-T 700 7 10 60L-800 700 with 7 10 60L-800-T 700 7 10 Fronius International GmbH CL 36.0 600 6 9 48.0 600 6 9 60.0 600 6 9 IG 15 500 5 7 20 500 5 7 2000 500 5 7 2500-LV 500 5 7 30 500 5 7 300 530 5 7 3000 500 5 7 390 530 5 7 40 500 5 7 400 530 5 7 4000 500 5 7 4500LV 500 5 7 500 530 5 7 5100 500 5 7 60 HV 530 5 7 IG Plus 100 600 6 9 100 V 600 6 9 11.4-1 Uni 600 6 9 120 600 6 9 120 V 600 6 9 150 600 6 9 150 V 600 6 9 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 9 of 23

30 V 600 6 9 35 600 6 9 35 V 600 6 9 50 600 6 9 50 V 600 6 9 70 600 6 9 70 V 600 6 9 Gamesa Corporación Tecnológica S.A. Central Inverter 100kW 900 500kW PLUS 1,000 with GEFRAN S.p.A. Radius Industrial APV 100k-TL 1,000 with APV 250k-TL 1,000 with APV 270k-TL 1,000 with APV 330k-TL 1,000 with Green Power Power PV 10 900 100 900 20 900 250 1,000 30 900 5 600 6 9 50 900 500 1,000 Helios Systems HS 100 900 HSC 1000C 900 with HSI 500 900 with IBC Solar AG ServeMaster 1650 HV 600 6 9 1650 MV 450 4 6 3300 HV 600 6 9 3300 MV 450 4 6 4600 HV 600 6 9 4600 MV 450 4 6 IDS Trade AG SOLO 500 1,000 with Ingeteam GmbH IngeconSun 500HE 900 with www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 10 of 23

500HE (1000V option) 1,000 with IngeconSun Lite 2,5 550 5 8 3,3 550 5 8 5 550 5 8 IngeconSun Power 100 900 50 900 60 900 70 900 80 900 90 900 IngeconSun Smart 10 900 12,5 900 15 900 20 900 25 900 30 900 JEMA IF 100 900 20 900 25 900 30 900 50 900 60 900 80 900 KACO Gerätetechnik GmbH Blueplanet 02xi Series 1502xi 550 5 7 2502xi 550 5 8 3502xi 600 6 9 5002xi 600 6 9 Blueplanet XP100-U H2 600 6 9 H4 600 6 9 Powador 14.0 TR3 600 6 9 1501xi 500 5 7 16.0 TR3 600 6 9 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 11 of 23

18.0 TR3 600 6 9 2002 600 6 9 3002 600 6 9 3501xi 500 5 7 4202 600 6 9 4501xi 500 5 7 5002 600 6 9 6002 600 6 9 TS20-HV 800 8 12 TS21-HV 800 8 12 Powador XP 100-HV 1,000 200-HV 1,000 200-HV TL 1,000 with 250-HV 1,000 250-HV TL 1,000 with 350-HV TL 1,000 with Kostal Solar Electric GmbH Piko 100 1,000 Leonics Apollo GTP-500 GTP-501 600 6 9 GTP-502 600 6 9 GTP-503 600 6 9 GTP-504 600 6 9 GTP-505 600 6 9 GTP-506 600 6 9 GTP-507 600 6 9 GTP-508 780 11 GTP-509 780 11 GTP-510 780 11 GTP-511 780 11 GTP-512 780 11 LTi REEnergy GmbH PV Master-Station PVMB 45-0270 900 Approved when used with an PVMB 45-0540 900 Approved when used with an www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 12 of 23

PVMB 45-0810 900 Approved when used with an PVMB 45-1080 900 Approved when used with an PVMC 45-0270 900 Aproved when used with an PVMC 45-0540 900 Approved when used with an PVMC 45-0810 900 Approved when used with an PVMC 45-1080 900 Approved when used with an PVMI 45-0270 900 Approved when used with an PVMI 45-0540 900 Approved when used with an PVMI 45-0810 900 Approved when used with an PVMI 45-1080 900 Approved when used with an PVmaster II PVM 450-075 TT 900 PVM 450-090 TT 900 PVM 450-100 TT 900 PVM 450-110 TT 900 PVM 450-132 EN/EM 900 with PVM 450-175 EN/EM 900 with PVM 450-230 EN/EM 900 with PVM 450-270 EN/EM 900 with PVM2 45-132EM 900 Approved when used with PVM2 45-175EM 900 Approved when used with an PVM2 45-230EM 900 Approved when used with an PVM2 45-270EM 900 with PVM2 50-200EM 900 Transformer: Yes modified MV transformer with taps to adjust the mpp window up to an minimal voltage of 450V is www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 13 of 23

mandatory. (new mpp window: 450-850VDC) PVM2 50-305EM 900 Transformer: Yes modified MV transformer with taps to adjust the mpp window up to an minimal voltage of 450V is mandatory. (new mpp window: 450-850VDC) Mastervolt SunMaster QS 1200 450 4 6 QS 2000 450 4 6 QS 3200 450 4 6 QS 3200 Max-I 450 4 6 QS 3500 Max-I 325 3 4 QS 6400 450 4 6 QS 6400 Max-I 450 4 6 XL 10 550 5 8 15 600 6 9 XS 2000 450 4 6 3200 600 6 9 4300 550 5 8 6500 600 6 9 Motech Industries Inc. PVMate 2800E 600 6 9 2900U 600 6 9 3800E 600 6 9 3840U 600 6 9 4000E 600 6 9 4900U 600 6 9 5000E 600 6 9 5300U 600 6 9 Nedap Power Router PR30S 600 6 9 PR37S 600 6 9 PR50S 600 6 9 Nextronex Energy Systems RAY-MAX 150 1,000 with 150 (600V) 600 To ensure a proper operation 6 9 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 14 of 23

of this inverter in an 600V DC system, it is mandatory to change the taps on the coupling transformer to 208V. This action will allow to export power up to a minimum voltage of 318V DC. Oelmaier Technology GmbH HS 100 900 PAIRAN GmbH pesos PVI 2300 T 500 5 7 Power Electronics freesun HES 0250OH 900 with external MV-transformer 0300OH 900 with external MV-transformer 0400OH 900 with external MV-transformer 0500OH 900 with external MV-transformer 0600OH 900 with external MV-transformer 0700OH 900 with external MV-transformer 0800OH 900 with external MV-transformer 0900OH 900 with external MV-transformer 1000OH 900 with external MV-transformer freesun LVT 0020 900 0025 900 0030 900 0035 900 0040 900 0050 900 0060 900 0080 900 0100 900 Power One Italy SpA Aurora Lite PVI-250.0-TL-CN 1,000 with PVI-500.0TL-CN 1,000 with Aurora Plus PVI-110.0 1,000 PVI-110.0-TL 1,000 with PVI-165.0 1,000 PVI-165.0-TL 1,000 with PVI-220.0 1,000 PVI-220.0-TL 1,000 with www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 15 of 23

PVI-275.0 1,000 PVI-275.0-TL 1,000 with PVI-330.0 1,000 PVI-330.0-TL 1,000 with PVI-55.0 1,000 PVI-Central-100 900 PVI-Central-100-TL 900 with PVI-Central-150 900 PVI-Central-150-TL 900 with PVI-Central-200 900 PVI-Central-200-TL 900 with PVI-Central-250 900 PVI-Central-250-TL 900 with PVI-Central-300 900 PVI-Central-300-TL 900 with PVI-Central-50 900 Aurora Trio PVI-10.0-I-OUTD 520 5 7 PVI-12.0-I-OUTD 520 5 7 Aurora Ultra 1050.0-TL-OUTD-690 1,100 with 1400.0-TL-OUTD-690 1,100 with 700.0-TL-OUTD-690 1,100 with Aurora Uno PVI-3.8-I-OUTD 520 5 7 PVI-4.6-I-OUTD 520 5 7 RefuSol GmbH Refu Sol 100k 850 8 12 160K 850 8 12 500K 950 9 14 630K 950 9 14 RIELLO UPS Helios Power HP 100 800 8 12 HP 25 800 8 12 HP 33 800 8 12 HP 40 800 8 12 HP 64 800 8 12 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 16 of 23

HP 80 800 8 12 Satcon PowerGate Plus 100 kw 900 135 kw 600 6 9 1MW 900 250 kw 900 30 kw 600 6 9 375 kw 600 6 9 50 kw 600 6 9 500 kw 900 75 kw 600 6 9 Solstice 500kW-CE 900 500kW-UL/CSA 600 6 9 Schneider Electric Conext Core XC 540 1,000 Core XC 630 1,000 Core XC 680 1,000 Schüco International KG IPE 100CT 900 30CT 900 60CT 900 SGI plus 1500 T 500 5 7 3500 T 500 5 7 4500 T 500 5 7 SIAC SOLEIL DSP 10 780 7 11 100 780 7 11 125 780 7 11 15 780 7 11 20 780 7 11 200 780 7 11 25 780 7 11 250 780 7 11 30 780 7 11 40 780 7 11 400 780 7 11 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 17 of 23

50 780 7 11 500 780 7 11 60 780 7 11 80 780 7 11 Siemens AG SINVERT 1000 MS TL 1,000 with 1000MS 900 1300 MS 900 1400MS 900 1500 MS TL 1,000 with 1700 MS 900 2000 MS TL 1,000 with 350M 900 420M 900 500 M TL 1,000 with 700MS 900 850MS 900 SINVERT PVS 1000 1,000 wit 1200 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually reconnections could be needed during the lifetime of the system. 1500 1,000 with 1800 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually reconnections could be needed during the lifetime of the system. 2000 1,000 with 500 1,000 with 600 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 18 of 23

reconnections could be needed during the lifetime of the system. 2400 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually reconnections could be needed during the lifetime of the system. SMA Solar Technology AG Sunny Boy 1200 400 4 6 1700 400 4 6 2000 HF 700 7 10 2500 600 6 9 2500 HF 700 7 10 3000 600 6 9 3000 HF 700 7 10 3300 500 5 7 3800 500 5 7 5000US 600 6 9 6000US 600 6 9 7000US 600 6 9 700US 250 2 3 Sunny Central 100 900 1000MV 1,000 1250 MV 1,000 200 880 8 13 250 880 8 13 250HE 880 8 13 350 880 8 13 400HE 1,000 400MV 1,000 500CP 1,000 with 500HE 1,000 500HE-20 1,000 with www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 19 of 23

500MV 1,000 630CP 1,000 with 630HE 1,000 630HE-20 1,000 with 630MV 1,000 720 CP 1,000 with 800MV 1,000 800CP 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually reconnections could be needed during the lifetime of the system. 760 CP 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 530V). Several manually reconnections could be needed during the lifetime of the system. 800HE-20 1,000 Transformer: Yes modified MV transformer with multiple taps to adjust mpp window (min mpp 500V). Several manually reconnections could be needed during the lifetime of the system. 900CP 1,000 Transformer: Yes modified MV/HV transformer with multiple taps to adjust mpp window (min mpp 545V). Several manually reconnections could be needed during the lifetime of the system. 15 Approved only for FS Series 3 Sunny Mini Central 4600A 600 6 9 5000A 600 6 9 6000A 600 6 9 7000HV 800 8 12 Socomec SUNSYS P03 900 with www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 20 of 23

R01 900 R02 900 Solectria Renewables, LLC PVI 10KW 475 4 7 13KW 475 4 7 15KW 475 4 7 SOLUTRONIC GmbH SOLEIL DSP 10 780 7 11 100 780 7 11 125 780 7 11 15 780 7 11 20 780 7 11 200 780 7 11 25 780 7 11 250 780 7 11 30 780 7 11 40 780 7 11 400 780 7 11 50 780 7 11 500 780 7 11 60 780 7 11 80 780 7 11 Sputnik Engineering GmbH SolarMax C 100C 900 20C 900 25C 900 300C 900 30C 900 330C-SV 900 with 35C 900 50C 900 80C 900 SolarMax TS 100TS 900 300TS 900 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 21 of 23

330TS-SV 900 with 50TS 900 80TS 900 Sungrow Power Supply Co., Ltd. SG 100K3 900 250K3 900 500K3 900 500KTL 900 with 50K3 900 630KTL 1,000 with SunTechnics STW 2000 800 8 12 2800 800 8 12 3800 800 8 12 5000 800 8 12 Vacon NXP CH 64 1,000 with Sinusstrom Beaver for max. system voltage of 1000V is mandatory NXV 0600-4 900 Voltwerk electronics GmbH VC WL 110 1,000 Voltwerk Smart Connect for max. system voltage of 1000V is mandatory WL 280 1,000 Voltwerk Smart Connect for max. system voltage of 1000V is mandatory WL 300 1,000 Voltwerk Smart Connect for max. system voltage of 1000V is mandatory Xantrex Technologies Inc. GT 100-480 600 6 9 100E 650 6 9 2.8 600 6 9 250-480 600 6 9 3.8 600 6 9 5.0 600 6 9 500E 940 9 14 500-MVX 600 with 6 9 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 22 of 23

540E 1,000 with 630E 1,000 with The 1000V version as well as an adjustment of the power tracking window range to an min. DC Voltage of 515V is mandatory. XC 540 1,000 with 630 1,000 with Zigor CORPORACIÓN S.A. Sunzet 100 T 800 8 12 30 T 800 8 12 50 T 800 8 12 www.firstsolar.com PD-5-332_Inverter list - safe use_level 5_Page 23 of 23