100A/60A Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay Alarms Power :: HPGMTXX & GMTXX Installation Guide

Similar documents
100A Universal Voltage Dual-Feed GMT Fuse Panels Power :: HPGMT10xx and HPGMT15 Installation Guide

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Dual-Feed 200A 4/5 TPA/GMT Fuse Alarm Panel. Model Installation Guide

Dual 100A 4/4-KLM & 4/4-GMT Fuse Panel. Model N Installation Guide

Dual-Feed 600A 8-Circuit Breaker/TPC/TFD Load Center With 5 GMTs

Demarcation Fuse/Circuit Breaker Alarm Panel 125DM08. Installation Guide

Demarcation Fuse Alarm Panel

Dual-Feed 600A Load Center Frame Power :: 600CB10 and 600CB12 User Manual

Low-Current 20/20 GMT Series Fuse Panels Models & Installation Guide

Dual-Feed 600A Load Center Frame

Installation Manual. AC Edge. Split Phase 60 A (6/6) AC Power Distribution Unit. AC Edge. Model AC60DF 6/6 Part#

:: :: TFD4 :: TFD6

TPM/GMT Panel Installation Guide

GMT Fuse Panel Installation Guide

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

Installing Power Components

nrgsmart Power Distribution Remote Monitoring

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

HMW Filtered Fuse Panel for GMT Fuses

Noran Tel. FUSE PANEL Technical Practice N21C110-NCY 5/5 GMT (20Amp GMT) NEBS Level 3 Certified

FUSE PANEL Technical Practice FDP /10 GMT NEBS Level 3 Certified

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

PowerWorx DSX Series GMT Fuse Panel User Manual

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

Noran Tel. Fuse Panel Technical Practice N NCY 4/4TPA & 6/6 GMT NEBS Level 3 Certified

Application Note. Best Solutions for Managing High-Current Power Distribution

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

OPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Connecting to DC Power

Fuse / Circuit Breaker Panels

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

Installing the ONS M6 Shelf

RU SERIES UPGRADE TempAssure Compatible

Shelf 19 version) (Expansion Shelf 19 version) (Main Shelf 23 version) (Expansion Shelf 23 version)

Circuit protection for telecom applications

INSTALLATION INSTRUCTIONS

POWER TRIM 5 E DUAL POWER TRIM CONTROL

Secondary DC Distribution E R P R P I 2. Technical Reference Guide

REMOTE POWERING Central Energy System ( HUB )

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.

NTK599BAE5 and NTK599BGE5 Breaker Interface Panel (BIP) Installation Manual

PEC 5068 BDFB 1-10 Loads, 500A Max/Load -48V, 2000A Max Load/Bay

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BETA Switching Switches and Light Indicators

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS

INSTALLATION INSTRUCTIONS

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

INSTALLATION INSTRUCTIONS

Installing the Switch Chassis

INSTALLATION INSTRUCTIONS

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

WARNING TABLE 3-1: DAILY SAFETY CHECK

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

GROUNDING & BONDING PRODUCTS

TPC & TPCDS. Telpower Compact Fused Disconnect Switch. Bussmann. Telpower. DC Power Protection Systems

Cisco ASR 1002 Router Overview and Installation

ANZI Transfer Switch and Generator Wiring Installation Addendum

Products. Section Contents

SAVE THESE INSTRUCTIONS

Dynamic Series Connectors

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

INSTALLATION INSTRUCTIONS

PM Series Power Module Power Supply/Battery Charger

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ATT DC POWER AND GROUNDING MINOR MATERIAL LIST A/

Circuit Breakers/Protection, Fuses/Fuse Products

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

F-Series General Specifications

Installing the Switch

Installation and Operations Manual

CONTROL FEATURES AVAILABLE OPTIONS

4.7. Contents Description Heavy Duty Hesitation Switches. Product Description. Standards and Certifications. Heavy Duty Hesitation Switches

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

CM52 Network Protector with Arc Flash Reduction Module

Raidtec Rack Mount Guide Version 2.1

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

SYSTEM OPERATION IMPORTANT CAUTIONS

PLASTI-GRIP* Terminals and Splices

Spreader and Vehicle Battery Kits

Raidtec 20-Inch Rack Mount Guide Version 1.0

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

DPoE Power System. User Manual

INSTALLATION INSTRUCTIONS

Transcription:

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Installation Guide pplies to : GMT10 :: GMT10F :: GMT20 :: GMT20S :: HPGMT10 :: HPGMT10F :: HPGMT15 :: HPGMT20 :: HPGMT20S Telect, Inc., ll Rights Reserved, 132152-9 0

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Table of ontents 1.1 Overview...1 1.2 Specifi cations...3 1.3 Important Installation Guidelines...5 1.4 Inspection...6 1.5 Installation...6 1.6 ccessories & larm ard... 13 1.5.1 Input & GND Lugs... 13 1.5.2 Single-hole Lug Part Numbers for GMT20 Output Terminals... 14 1.5.3 GMT Fuses... 14 1.5.4 larm ard... 15 1.7 Diagrams... 15 1.8 Dimensions... 17 List of Figures Figure 1 - GMT Fuse Panel...1 Figure 2 - GMT-Series omparison hart...2 Figure 3 - Bracket Orientation...7 Figure 4 - Rack Mounting...7 Figure 5 - Ground Lug onnection...8 Figure 6 - Input onnections on a 100 Panel...9 Figure 7 - Input onnections on a 60 Panel...9 Figure 8 - Status LEDs on Face of... 10 Figure 9 - larm Terminals on Rear of Panel... 10 Figure 10 - Output onnections... 10 Figure 11 - Designation ard... 11 Figure 12 - larm Schematics (Rear of Designation ard)... 12 Figure 13 - larm ard... 15 Figure 14 - GMT10 & GMT10F... 15 Figure 15 - HPGMT10 & HPGMT10F... 16 Figure 16 - GMT20S (Typical dimensions also for GMT20)... 17 Figure 17 - HPGMT10 (Typical dimensions also for GMT10, HPGMT15, & HPGMT20S).. 18 Figure 18 - HPGMT20... 19 Figure 19 - HPGMT10F...20 Figure 20 - GMT10F...21 Telect, Inc., ll Rights Reserved, 132152-10 0 ii

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.1 Overview Telect s 60 and 100 GMT Panels are compact 1RU EI power panels enabling + 24 and -48 Vdc power protection for a variety of wireline and wireless telecommunications and data equipment. These GMT-Series panels are ideal for powering tracer lamps in dense DSX bays, as well as network equipment with Figure 1 - GMT Fuse Panel low-to-medium power requirements. Most GMT-Series panels fit either 19-in. or 23-in. racks. (See the comparison chart on page 2.) ll panels are white except HPGMT10-BLK, which is black. The panel provides total front access to fuses and LED status. Below the bezel holding the status LEDs is a pull-out designation card holder. ll terminals for inputs, outputs, ground, and alarms are on the same side either all on the rear or all on the front. ll terminals are covered by a single full-width transparent terminal cover: Inputs are either dual-hole lugs for studs (100 panels) or bare conductors for barrel connectors (60 panels). Ground terminals accept either single- or dual-hole lugs. Output screw-post terminals accept either ring or forked lugs, as well as bare wire. Power/fuse and bay alarms terminals, along with external bay alarm trigger terminals, are wirewrap pins. GMT-Series panels differ in load rating (60 or 100), capacity (10, 15, or 20 GMTs per side), single or dual feed, and total front access (GMT10F and HPGMT10F) panels vs. panels with rear-side terminals. ll panels are 1RU with the exception of HPGMT10F, which is 2RU. The GMT fuse holders are mounted upside-down so that the GMT indicator flag flips downward when activated, making identification and detection easier, especially on tall racks. In addition, the GMT fuse holders are mounted separately not as a fuse block thereby making fuse- position management unnecessary when dealing with 10, 15, and 20 GMT fuses. Holes for color-coded fuse designation pins are located below each fuse position. The panel also features separate power and fuse failure status LEDs and power alarm relay connections for each feed. Major and minor bay alarm LEDs and wirewrap terminals are controlled via an on-board relay triggered by an external switch closure. ll on-board relay contacts are dry Form-. ll LEDs and alarm relays and contacts are located on an easily removable alarm card. Telect, Inc., ll Rights Reserved, 132152-10 0 1

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Telect ships phoney fuses for each GMT fuse position. Visit our website (telect.com) to order GMT fuses, fuse designation pins, and other accessories. The following table shows a comparison of the GMT-series fuses. ll Telect s GMT-Series panels are UL listed (US and anada, File E139903) and NEBS Level 3 certified, and RoHS compliant. Features GMT10 GMT10F GMT20 GMT20S HPGMT10 HPGMT10F HPGMT15 HPGMT20 HPGMT20S 60 Max. Input x x x x 100 Max. Iput x x x x x 20 Max. Fuse Position 15 Max. Fuse Position x x x x x x x x x Universal VD x x x x x x x x x Dual Bus x x x x x x x Single Bus x x Fuse Positions per Feed 10 10 20 20 10 10 15 20 20 Rack Units 1 1 1 1 1 2 1 1 1 Width 19 23 19 19 19 19 19 23 19 Front ccess x x Stud Input x x x x Screw lamp Input x x x x Baylarm x x x x x x x x x Legend: HP=High Power, F=Front ccess, S=Single Bus Figure 2 - GMT-Series omparison hart Telect, Inc., ll Rights Reserved, 132152-10 0 2

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.2 Specifications Inputs: Voltage & Range ±20 Vdc to ±60 Vdc @ 20 ±22 Vdc to ±58 Vdc @ 55 Max. Input Load Rating 60/100 depends on model Max. Power Dissipation at Full Load < 50W per side (max.) for panels rated for 60 < 75W per side (max.) for panels rated at 100 % of Full Load Power Dissipation less then 1% for all models Max. Input Interruption Device 75 for 60 panels 125 for 100 panels Input Terminals 100 Panels Dual 1/4-20 studs on 5/8 in. centers. Torque KEPS nut (using 7/16 in. or 12 mm socket) to ~50 in.-lb (~5.6 N m), max. 60 Panels Barrel-style screw-down terminals for #14 WG to #6 WG bare conductor. Torque to 16 in.-lb (1.8 N m), max. Outputs: Max. GMT Output Fuse (ea.) Max. GMT Output Load (ea.) Max. Total GMT Output Per Side Output Terminals (Wire-Binding Screw Posts) GMT Output Wire Size Range Interrupt Rating Short-ircuit Withstand urrent 20 for all but GMT20 15 for Model GMT20 14 continuous for all but Model GMT20 10.5 for Model GMT20 100 for 100 panels 60 for 60 panels #6-32 for all panels except Model GMT20 #3-48 for Model GMT20 #22 to #14 WG, depending on output fuse (.6 to 20) for all but GMT20 #30 to #16 WG, depending on output fuse (.18 to 15) for Model GMT20 450 450 larms: larm Relay ontacts Max. larm Power Rating larm Wire Size larm Terminals Dry Form- contacts (1 @ 30 Vdc, 0.3 @ 100 Vdc, 0.5 @ 125 Vac) @24V: 72 m (1.73W) @48V: 147 m (7.06W) #22 to #18 WG Wirewrap Telect, Inc., ll Rights Reserved, 132152-10 0 3

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Grounding: hassis GND Terminal Studs (With KEPS Nuts) for Dual-Hole ompres- sion Lug GND Wire Size #10-32 studs on 5/8-in. centers. Torque KEPS nut (using 3/8 in. or 10 mm socket) to ~20 in.-lb (~2.3 N m), max. #6 (preferred) or #8 WG for a 100 panel #10 WG for a 60 panel Dimensions (Nominal): a Width x Height x Depth for all except TF & HPGMT20 b Width x Height x Depth for GMT10F & HPGMT20 c Width x Height x Depth for HPGMT10F d 17 x 1.75 x 9 in. (432x44x229mm) 21 x 1.75 x 9 in. (533x44x229mm) 17 x 3.50 x 9 in. (432x89x229mm) a. Without mounting brackets. b. ll 1RU panels that fit either a 19-in. or 23-in. rack. c. Models GMT10F & HPGMT20 only fit 23-in racks. d. Model HPGMT10F is a 2RU panel that fit either a 19-in. or 23-in rack. Fit & Finish Material olor 16-gauge steel White powder coat for all but HPGMT10-BLK (black) Weights (pproximate) ll Single & Dual Panels with 10 GMTs Per Side, Except GMT10F & HPGMT10F Installed 8 lb (3.5 kg) Shipping 11 lb (5 kg) HPGMT15 Installed 9lb (4kg) Shipping 12 lb (5.5 kg) GMT20 Installed 11lb (5kg) Shipping 14 lb (6.25 kg) Models GMT10F & HPGMT20 Installed 11lb (5kg) Shipping 14 lb (6.25 kg) Model HPGMT10F Installed 11lb (5kg) Shipping 14 lb (6.25 kg) Telect, Inc., ll Rights Reserved, 132152-10 0 4

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms Environment: Operating Temperature Humidity -10 (14 F) to 55 (131 F) 0 to 90% and noncondensing 1.3 Important Installation Guidelines Elevated Operating mbient - If you install the rack in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, take care to install the equipment in an environment compatible with the maximum ambient temperature (TM) specified by the manufacturer. Reduced ir Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading. ircuit Overloading - Give consideration to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Use appropriate consideration for equipment nameplate ratings when addressing this concern. Reliable Earthing - Maintain reliable earthing of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips). Disconnect Device - Incorporate a readily accessible disconnect device in the building installation wiring. Telect, Inc., ll Rights Reserved, 132152-10 0 5

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.4 Inspection Please read and understand all instructions before starting installation. If you have questions, contact Telect Technical Support at support@telect.com or call 1.509.926.6000. When you receive the equipment, carefully unpack it and compare it to the packaging list. Please report any defective or missing parts to Telect Quality at quality@telect.com or call 1.509.926.6000. Telect is not liable for trasit damaged. If the product is damaged, please report it to the carrier and contact Telect Quality. 1.5 Installation! LERT LERT! Install this product within a restricted access location where access is through the use of a tool, lock and key, or other means of security, and is controlled by the authority responsible for the location. This product must be installed and maintained only by qualified technicians. Verify all connections meet requirements specified in local electric codes or operating company guidelines before supplying power. Unit shall be protected by a listed circuit breaker or branch-rated fuse rated maximum 75 (for 60-rated feeds) and maximum 125 (for 100-rated feeds). ll panels except Models GMT10F and HPGMT20 can be mounted in 19-in. EI racks. Telect also offers bracket kits for WEO and ETSI racks. (See our website at telect.com.) GMT10F and HPGMT20 only fit 23-in. racks. ll panels can be flush-mounted or extended by 2 in. or 4 in. beyond the rack flange. Telect, Inc., ll Rights Reserved, 132152-10 0 6

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1. If necessary, remove three screws and reposition/ re-align brackets on sides of distribution the panel, as shown in the illustration on the right. 2. Locate an unused rack position, normally at the top of the rack. Mount the panel to the rack using four, #12-24 thread-cutting screws and lock washers provided, as shown in Figure 4. 3. Tighten screws to 35 in.-lb (4.29 N m). 4. Remove the transparent terminal cover, shown in Figure 5. et Oriented for 19-in. Rack Flush Extended by 2 in. Extended by 4 in.! WRNING WRNING! Failure to properly ground this equipment can create hazardous conditions for installation personnel and for the equipment. Bracket Oriented for 23-in. Rack Figure 3 - Bracket Orientation Figure 4 - Rack Mounting Telect, Inc., ll Rights Reserved, 132152-10 0 7

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms! LERT LERT! Only use components and crimping tools approved by agencies or certifying bodies recognized in your country or region, such as Underwriter s Laboratories (UL), TUV, etc. 5. Use a listed (approved) crimping tool to attach a listed (approved), dual-hole, right-angle compression lug for #10 studs on 5/8-in. centers onto #6 WG ground wire. (Min. #8 WG for a 100 feed; #10 WG for a 60 feed.) 6. If desired (highly recommended), lightly coat anti-oxidant on lug, grounding terminal, and surrounding contacting surface. 7. onnect the lug using the #10-32 KEPS nuts and flatwashers provided, as shown in Figure 5. 8. Tighten KEPS nuts to ~20 in.-lb (~2.3 N m), max. 9. Make sure input power is off (open breaker, phoney fuse, or open fuse holder at primary power distribution unit [PDU]) before connecting this panel s input cables to that PDU. Figure 5 - Ground Lug onnection! WRNING WRNING! Before connecting input power cables, make sure the input power to the panel is turned off. 10. For input wiring wiring used as inputs to this distribution the panel do one of the following: (Refer to the following illustrations.) For input wiring on a 100 panel (see page 9 for 60 input wiring instructions) a. rimp dual-hole compression lugs onto #8 to #1/0 WG conductors (#1/0 WG with a 60 insulation rating, minimum for a 100 feed). Insulate lug barrels with UL94 V-0 rated heat-shrink tubing. b. lean terminals and lugs with an nonabrasive, nonmetallic cloth. c. If desired (highly recommended), lightly coat anti-oxidant on lugs, terminals, and contacting surfaces. d. onnect lugs to input BTT and terminals on the panel. e. Torque KEPS nuts to ~50 in.-lb (~5.6 N m), max. 11. Make sure GMT fuse positions are either empty or contain dummy fuses (phoney, inoperative, all-plastic slugs). Telect, Inc., ll Rights Reserved, 132152-10 0 8

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms For input wiring on a 60 panel Figure 6 - Input onnections on a 100 Panel a. Strip off about 3 4 in. (10 mm) of insulation at end of input conductors (min. #6 WG for a 60 feed). b. If desired (highly recommended), lightly coat anti-oxidant on the bare conductor. c. Insert the bare conductor into the barrel connector as indicated in the illustration, and then tighten the screw to 16 in.-lb (1.8 N m), max. DO T REMOVE PS* * Screws located below caps are used for installing internal wiring at the factory.! LERT Figure 7 - Input onnections on a 60 Panel LERT! Only service personnel may replace fuses. The installer must verify that a readily accessible protection device is incorporated in the building wiring feeding the fuse panel: 125 (max.) protection device for a 100 panel; 75 (max.) for a 60 panel. Telect, Inc., ll Rights Reserved, 132152-10 0 9

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 12. Enable protection device (fuse or breaker) at primary PDU to turn on Feed to Side of panel and then check voltage and polarity at input connectors of panel. lso, check that PWR LED on front of panel turns on (green). PWR B LED and both FUSE LEDs must be off. 13. With PWR lit but with PWR B LED off test power-fail relay and contacts at PWR alarm terminals on rear of panel: Expect continuity (0Ω) between Terminals and. Expect an open circuit (00Ω) between Terminals and. 14. lso, test fuse alarm relay contacts at FUSE alarm terminals, then Expect continuity (0Ω) between Terminals and. Expect an open circuit (00Ω) between Terminals and. 15. Repeat Steps 12 through 14 to power up Side B. PWR and PWR B LEDs must both be green. 16. With PWR and PWR B lit, test power-fail relay and contacts at PWR and PWR B alarm terminals: Expect continuity (0Ω) between Terminals and. Expect an open circuit (00Ω) between Terminals and. 17. Make sure none of the fuse positions contain real, operable fuses. 18. For GMT output wiring, proceed as follows: For all Models except GMT20 R PWR FUSE PWR B FUSE B MJOR LM MIR LM Figure 8 - Status LEDs on Face of Removable larm ard MJ MIN PWR PWR B FUSE Figure 9 - larm Terminals on Rear of Panel a. Working with one wire at a time, either: rimp a single-hole ring or fork lug for a #6-32 screw-post terminal, as required by NE, or Strip 3/8 in. (10 mm) of insulation from a #26 to #12 copper wire for a bare-wire connection. b. lean the panel terminals and lug (if applicable) with a nonabrasive, nonmetallic cleaning pad. c. If required, lightly coat anti-oxidant on lug/wire and output BTT and terminals, and then connect to terminals. Figure 10 - Output onnections Telect, Inc., ll Rights Reserved, 132152-10 0 10

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms (NE specifies only one load at each output terminal.) Tighten #6-32 screws using either a flat-tipped screwdriver or Phillips screwdriver (for cross-re- cessed screw heads) to no greater than 6 in.-lb (~0.7 N m). onnect other end of output wire to load. For Model GMT20 a. Working with one wire at a time, either rimp a single-hole ring or fork lug for a #3-48 screw-post terminal, as required by NE, or Strip 3/8 in. (10 mm) of insulation from a #30 to #16 copper wire for a bare-wire connection. b. lean panel terminals and lug (if applicable) with a nonabrasive, nonmetallic cleaning pad. c. If required, lightly coat anti-oxidant on lug/wire and output BTT and terminals, and then connect to terminals. (NE specifies only one load at each output terminal.) Tighten #5-40 screws using either a flattipped screwdriver or Phillips screwdriver (for cross-re- cessed screw heads) to no greater than 5 in.-lb (~0.6 N m). onnect other end of output wire to load. 19. Record circuit assignments in accordance with operating company procedures and guidelines. The manufacturer s designation card, shown below, is a 10 in. (254 mm) by 21 2 in. (57 mm) card that folds in half to fit a card holder located below the status LEDs. 20. Make sure load devices are off (disabled) and then install GMT fuses. Remember, GMT fuses need to be installed so that failure indication flags are at the bottom,as shown in the following illustration. SIDE FUSETYPE RK/BY# SIDE B FUSETYPE RK/BY# POS MP DESRIPTION POS MP DESRIPTION POS MP DESRIPTION POS MP DESRIPTION! LERT Figure 11 - Designation ard LERT! GMT fuses have a small inherent electrical resistance resulting in a small inherent power loss. For this reason, the GMT fuse manufacturer recommends that the load for GMT fuses up to and including 7.5 not exceed 80% of the fuse rating and that the load for GMT fuse sizes between 10 and 20 not exceed 70% of the fuse rating. For example, the load for a 15 GMT fuse should not exceed 10.5 (15 x 0.70 = 10.5). Telect, Inc., ll Rights Reserved, 132152-10 0 11

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms The total load for all fuse outputs on each side must not exceed the panel s load rating: either 60 or100. 21. Test power and polarity at input of each equipment load. 22. If possible, replace one of the operable GMT fuses with a blown fuse to verify that the applicable FUSE larm LED turns red. lso, check the FUSE alarm terminals on the rear of the panel: Expect an open circuit (00Ω) between Terminals and. Expect continuity (0Ω) between Terminals and. Re-install operable GMT fuse before proceeding. If desired, connect remote, external audio/visual panel alarm indicator wires (solid wires, #22 to #18 WG) to wirewrap PWR and FUSE alarm pins on rear of panel, as shown below on the right. 23. If desired, connect remote audio/visual bay alarms indicator wires to the MJ (major) and MIN (minor) alarm pins. lso install switch closure wires to the (activate) and R (reference) pins, as shown above on the left, to control the bay alarm relay. 24. Re-install terminal cover. 25. Lastly, enable equipment loads one at a time to verify the proper operation of loads. TO LRM SYSTEM MJ MIN R EXTERNL LOOP LOSURE TO LRM SYSTEM - TIVTE R - REFEREE TO LRM SYSTEM PWR PWR B FUSE TO LRM SYSTEM BY LRM TERMINLS ENHED PNEL LRM TERMINLS Figure 12 - larm Schematics (Rear of Designation ard) Telect, Inc., ll Rights Reserved, 132152-10 0 12

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.6 ccessories & larm ard The following lists optional and replacement items for the panel. For compression lugs, please refer to Wire Sizing & Label onvention hart (Telect Part No. 117995) included with your panel.! WRNING WRNING! Use only UL-listed fuses or UL-recognized component secondary protection devices. 1.5.1 Input & GND Lugs The following table describes the available input lugs for stranded copper conductors with straight dual-hole lugs for 1/4-in. studs on 5/8-in. centers. Table 1 - Input Lugs Source #1/0 WG #2 WG #4 WG #6 WG #8 WG T & B 54206 (Die ode 29 Panduit Burndy Y25L2NT14 (Die ode12) LDN2-14-Q (Die ode 33) LD4-14- (Die ode 29) Y4L2T14 (Die ode 8) 54205 (Die ode 24) LD6-10-L (Die ode 24) Y6L2T14 (Die ode 7) 542040416 (Die ode 21) LD8-10-L (Die ode 21) Y8L2T14 (Die ode 49) The following table describes the available ground lugs for stranded copper conductors with 90 dual-hole lugs for #10 studs on 5/8-in. centers. Table 2 - Ground Lugs Source #6 WG #8 WG T&B 256-30695-1356 (Die ode 24) 54204UB (Die ode 21) Panduit LD6-10F-L (Die ode 24) LD8-10F-L (Die ode 21) Burndy Y6L2T1090 (Die ode 7) Y8L2T1090 (Die ode 49) Telect, Inc., ll Rights Reserved, 132152-10 0 13

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.5.2 Single-hole Lug Part Numbers for GMT20 Output Terminals (For #3 Panhead Screws) The GMT20 output terminals accommodate bare wire up to #16 WG. If lugs are required, only three with insulated barrels apply for accommodating #22 - #14 WG: MP 324608 with a flanged (dog-eared), straight, forked tongue for #22 - #16 WG Burndy TP14-2F with a straight, forked tongue for #16 - #14 WG Burndy TP14-2Z with a flanged, straight, forked tongue, also for #16 - #14 WG 1.5.3 GMT Fuses For additional dummy fuses, order part number 132748. For GMT safety (splash/splatter) covers, order part number 116915 for GMT fuses up to 15. Telect recommends using only UL-recognized supplementary protectors. GMT Fuse Part Numbers GMT Fuse olored Designation Pin Part No..18 Yellow (YEL) 130781 102435-21 1 4 Violet (VIO) 100151 102435-2 1 2 Red (RED) 004001 102435-5 3 4 Brown (BRN) 004008 102435-7 1 Gray (GRY) 100991 102435-8 11/3 White (WHT) 004006 102435-9 11 2 White/Yellow (WHT/YEL) 004011 102435-10 2 Orange (ORN) 004002 102435-11 2.5 White/Orange (WHT/ORN) 130783 102435-12 3 Blue (BLU) 004012 102435-13 3.5 White/Blue (WHT/BLU) 130782 102435-14 4 White/Brown (WHT/BRN) 004013 102435-15 5 Green (GRN) 004014 102435-16 71 2 Black/White (BLK/WHT) 004010 102435-17 10 Red/White (RED/WHT) 004015 102435-18 12 Yellow/Green (YEL/GRN) 102287 102435-19 15 Red/Blue (RED/BLU) 102288 102435-20 20 White/Green Without Safety over 127240R (WHT/GRN) 20 White/Green With Safety over (WHT/GRN) 131340 102435-22 Telect, Inc., ll Rights Reserved, 132152-10 0 14

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.5.4 larm ard The alarm card (Telect Part No. 304304) is fastened to the front of the panel by four Phillips screws (screws with cross-recessed heads). To remove the alarm card, remove the screws, gently slide out status LED bezel and alarm card, and then disconnect the header cables near the far end of the alarm card. WHT larm ard BLK Faceplate & screws are not part of alarm card assembly. Figure 13 - larm ard 1.7 Diagrams The diagrams that follow are representative of Telect s GMT-Series of power panels. BTT 1 2 3 4 5 6 7 8 9 10 GMT OUTPUT BTT 1 2 3 4 5 6 7 8 9 10 PWR FUSE PWR B FUSE B MIR LM MJOR LM LRM PB R MJ MIN PWR PWR B FUSE GND Side B same as Side Figure 14 - GMT10 & GMT10F Telect, Inc., ll Rights Reserved, 132152-10 0 15

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms PWR FUSE PWR B FUSE B MIR LM MJOR LM LRM PB Side B same as Side R MJ MIN PWR PWR B FUSE BTT 1 2 3 4 5 6 7 8 9 GMT OUTPUT BTT 10 GND 1 2 3 4 5 6 7 8 9 10 GMT OUTPUT Figure 15 - HPGMT10 HPGMT10F Telect, Inc., ll Rights Reserved, 132152-10 0 16

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms 1.8 Dimensions The dimensioned drawings that follow are representative of Telect s GMT-Series of power panels. TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. #3-48 Screw Posts 0.19 [4.8] DO T REMOVE PLSTI PS BTT 60 MX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 BTT MJ MIN PWR PWR B FUSE R 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 BTT BTT B 60 MX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 10-32 Studs With KEPS Nuts & Flat Washers 5 8 [15.9] Barrel onnector GMT20 RER VIEW (R OTTE D) TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. #6-32 Screw Posts 0.29 [7.5] DO T REMOVE PLSTI PS 20 19 18 17 16 15 14 13 12 11 MJ MIN PWR PWR B FUSE 10 9 8 7 6 5 4 3 2 1 BTT R BTT 60 MX 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 10-32 Studs With KEPS Nuts & Flat Washers 5 8 [15.9] Barrel onnector RER VIEW (R OTTED) Transparent Plastic Terminal over 11.68 [296.7] 9.00 [228.6] 4.00 [101.6] 2.00 [50.8] 0.45 [11.4] Phoney GMT Fuses TOP VIEW EI Brackets (WEO & ETSI Bracket Kits are vailable.) SINGLE BUS 60 + - 48 24 V- - - 20 GMT FUSE MX 1 2 3 4 5 6 7 8 9 10 PWR FUSE PWR FUSE MIR MJOR B B LM LM 20 GMT FUSE MX 11 12 13 14 15 16 17 18 19 20 1.25 [31.7] 1.72 [43.7] GMT20S 17.00 [431.8] 18.31 [465.1] 19.00 [482.6] 22.31 [566.7] 23.00 [584.2] FRONT VIEW Figure 16 - GMT20S (Typical dimensions also for GMT20) Telect, Inc., ll Rights Reserved, 132152-10 0 17

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. 6-32 Screw Posts 0.29 [7.5] 5 8 [15.9] BTT B 100 MX BTT 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 MJ MIN PWR PWR B FUSE R 10 9 8 7 6 5 4 3 2 1 10 9 8 7 6 5 4 3 2 1 BTT BTT 100 MX 0.28 [7.2] 10-32 Studs With KEPS Nuts & Flat Washers 5 8 [15.9] 1 4-20 Studs With KEPS Nuts & Flat Washers RER VIEW (R OTTED) Transparent Plastic Terminal over 11.70 [297.3] 9.00 [228.6] 4.00 [101.6] 2.00 [50.8] 0.45 [11.4] Phoney GMT Fuses TOP VIEW EI Brackets (WEO & ETSI Bracket Kits are vailable.) BUS 100 + 24-48 V - - - 20 GMT FUSE MX 1 2 3 4 5 6 7 8 9 10 PWR FUSE PWR B FUSE MJOR MIR B LM LM 20 GMT FUSE MX 1 2 3 4 5 6 7 8 9 10 BUS 100 B + 24-48 V - - - 1.25 [31.7] 1.72 [43.7] 17.00 [431.8] 18.31 [465.1] 19.00 [482.6] 22.31 [566.7] 23.00 [584.2] HPGMT10 FRONT VIEW Figure 17 - HPGMT10 (Typical Dimensions also for GMT10, HPGMT15, & HPGMT20S) Telect, Inc., ll Rights Reserved, 132152-10 0 18

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. 6-32 Screw Posts 0.29 [7.5] 5 8 [15.9] BTT B 100 MX 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BTT 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 MJ MIN PWR PWR B FUSE R 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BTT BTT 100 MX 0.28 [7.2] 10-32 Studs With KEPS Nuts & Flat Washers 5 8 [15.9] 1 4-20 Studs With KEPS Nuts & Flat Washers RER VIEW (R OTTE D) Transparent Plastic Terminal over 11.69 [296.8] 9.00 [228.6] 4.00 [101.6] 2.00 [50.8] 0.45 [11.4] Phoney GMT Fuses TOP VIEW EI Brackets (WEO & ETSI Bracket Kits are vailable.) BUS 100 + - 48 24 V- - - PWR FUSE PWR FUSE MIR MJOR B B LM LM 20 GMT FUSE MX 20 GMT FUSE MX 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 16 17 18 15 19 20 BUS 100 B + - 48 24 V- - - 1.25 [31.7] 1.72 [43.7] 21.00 [533.4] 22.31 [566.7] 23.00 [584.2] HPGMT20 FRONT VIEW Figure 18 - HPGMT20 Telect, Inc., ll Rights Reserved, 132152-10 0 19

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. 9.00 [228.6] 11.25 [285.9] 4.00 [101.6] 2.00 [50.8] Phoney GMT Fuses Transparent Plastic Terminal over EI Brackets (WEO & ETSI Bracket Kits are vailable.) TOP VIEW BTT BUS 100 + - 48 24 V- - - PWR FUSE PWR FUSE MIR MJOR B B LM LM 20 GMT FUSE MX 20 GMT FUSE MX 7 8 9 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 10 PWR PWR 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 MJ MIN FUSE B BTT BTT BUS 100 B + - 48 24 V- - - BTT 3.00 [76.2] 3.47 [88.1] 1 2 3 4 5 6 7 8 9 10 R 1 2 3 4 5 6 7 8 9 10 0.28 [7.2] 0.29 [7.5] 5 8 [15.9] m #6-32 Screw Posts 5 8 [15.9] 1 4-20 Studs With KEPS Nuts & Flat Washers 10-32 Studs With KEPS Nuts & Flat Washers HPGMT10F 17.00 [431.8] 18.31 [465.1] 19.00 [482.6] 22.31 [566.7] 23.00 [584.2] FRONT VIEW Figure 19 - HPGMT10F Telect, Inc., ll Rights Reserved, 132152-10 0 20

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms TES: 1. ll dimensions are in in. [mm]. 2. Panel includes phoney fuses. ctual fuses are sold separately. 9.00 [228.6] 11.23 [285.2] 4.00 [101.6] 2.00 [50.8] Phoney GMT Fuses Transparent Plastic Terminal over EI Brackets (WEO & ETSI Bracket Kits are vailable.) TOP VIEW 6-32 Screw Posts 0.29 [7.5] DO T REMOVE PLSTI PS BUS 60 BTT 1 2 3 4 5 6 7 8 9 10 20 GMT FUSE MX 20 GMT FUSE MX BUS 60 MJ MIN PWR PWR BTT 1 2 3 4 5 6 7 8 9 10 B FUSE 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 PWR FUSE PWR FUSE MIR MJOR R B 1.25 [31.7] 1.72 [43.7] B B LM LM + - 24,-48 V- - - 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 +- 24,-48 V- - - 10-32 Studs With KEPS Nuts & Flat Washers 21.00 [533.4] 22.31 [566.7] 23.00 [584.2] 5 8 [15.9] Barrel onnector GMT10F FRONT VIEW Figure 20 - GMT10F Telect, Inc., ll Rights Reserved, 132152-10 0 21

100/60 Universal Voltage GMT Fuse Panels With Enhanced Power/Fuse & Bay larms This page intentionally left blank. Telect, Inc., ll Rights Reserved, 132152-10 0 22