INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Similar documents
INSTALLATION INSTRUCTION W Track Suspension system

RECESSED TRACK (120V) SPECIFICATIONS

WARNING NORDIC ALUMINIUM LIGHTING TRACK SYSTEMS

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

MOUNTING SYSTEMS SPECIFICATIONS

INTEGRID TRACK (120V) SPECIFICATIONS

SURFACE TRACK (120/250V) SPECIFICATIONS

GEMINI HOUSING SPECIFICATIONS

IMPORTANT SAFETY INSTRUCTIONS

SURFACE CONTROLTrack SPECIFICATIONS

NT-300 Series Single Circuit Track System & Accessories

Alphabet By Ledra Brands

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

COMPACT BUSWAY 40 & 60 AMP HOUSING

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

The lever must be placed at the lower position, when the track head is intended to be use in a one-circuit track system.

ZIP LIGHT LED LUMINAIRE

Two Circuit Trac System TRAC SECTION, JOINERS & FEEDS

Installation Instruction

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

poollux Power plx-pw60 & plx-pw100

MASTERsine Inverter PXA Series Installation Guide

Catalog # Project. Comments. Prepared by. L653 L =12'Nominal Actual length: 140-1/8" [3559mm] W=1 3/8" [3559mm] H =11/16" [17.5mm]

Assembly instruction. Pendant Light Toccata GENERAL REMARKS ON SAFETY: Technical data: BOM

TRAC-LITES One Circuit Trac System TRAC SECTIONS & SYSTEM COMPONENTS R Series

Elegance Electrician s Installation Guide

2 CIRCUIT TRACK. Notes: INSTALLATION PROFILE SURFACE TRACK COLOR. Page 1/9. Date :12/06/17 Rev.02 WHITE POWDER COAT SILVER ANODIZED

4 ft 8 ft 12 ft. straight factory bent. End Cap for Recessed Track Mount for Bruck s GEO track. Offered in white, matte silver or black.

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

INSTALLATION INSTRUCTIONS

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Track Accessories. Single Circuit Track. L Connector T Connector X Connector. Mini Connector Floating Canopy End Feed Kit.

TO AVOID DOING IRREPARABLE DAMAGE TO DRIVE CIRCUITRY NEVER APPLY AC POWER DIRECTLY TO LED LIGHTBOXES!

IMPORTANT SAFEGUARDS

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Product Selection Guide

LSI 20 Series 30A, 120V Surface Busway Components 1

ASSEMBLY INSTRUCTIONS

MIRRORLITE RECESSED EMERGENCY LIGHTING

PDX and PX Retrofit Series

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Project. Comments. Prepared by. 20-1/8" [511mm] 44-1/8" [1121mm] 92-1/8" [2340mm] 140-1/8" [3559mm]

PDI PowerWave 2 Bus System

MIDTOWN INSTRUCTIONS. White, Silver, Black. Single Light. MIDTOWN LED Recessed Light Installation Guide LED RECESSED LIGHT. (The nuts & bolts)

MOTORIZED INSTALLATION INSTRUCTIONS

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Juno Trac-Master Trac Lighting Systems. Comprehensive line and low voltage track systems

168 Georgetown Road Canonsburg, PA USA Phone: Toll Free: Fax:

INSTALLATION INSTRUCTIONS RECESSED EXTRUSIONS WITH LED TAPE

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Owner's/Installation Manual

Busway Construction. Bus Bars

General Installation Instructions LED

Reflectors are compatible with respective Marquise I series housings manufactured by Nora Lighting.

Reflectors are compatible with respective Marquise II series housings manufactured by Nora Lighting.

NRM2-511 / NRM2-512 / NRM2-518

INSTALLATION INSTRUCTION MANUAL

Installation Manual. For. Alumavator / Platinum Boathouse Lifts

LED IMPORTANT SAFETY INSTRUCTIONS

Snake Bus Power Distribution

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

When using electrical equipment, basic safety precautions should always be followed including the following:

Elle Surface Mounting Instructions

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

HALO H99ICT. 4" RECESSED DOWNLIGHTING Incandescent

Installing Your 220v J-POD Kit

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

SAVE THESE INSTRUCTIONS

A B C D E F. Tools Required (supplied by others)

HBDBM High Bay Series

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts

AEROBAY INSTALLATION INSTRUCTIONS

Installation Instructions Central Battery Units

NRM-411 / NRM-412 / NRM-413 / NRM-418 4" Marquise I Reflectors

MONORAIL KITS INSTALLATION INSTRUCTIONS PENDANTS

Installation Manual. For. Trident Boat Lifts

INSTALLATION INSTRUCTION MANUAL

HALO H5RICAT. 5" RECESSED DOWNLIGHTING Incandescent

Installing a Downstream Distribution Panelboard

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

LIGHTPLANE 1 RECESSED - LP1R

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Lumination TM LED Luminaire LUR Series

Power In - Pathways Technology Wall

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

SAVE THESE INSTRUCTIONS

NOVO LIGHTED MIRROR. Installation Instructions

LED Light Bar. Series LLB. Installation Instructions

Product Installation Instruction LED Tube Lamp Retrofit Kits

High Bay Luminaire Series

NRM-511 / NRM-512 / NRM-518

Transcription:

W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying the system. Do not install within six inches of any curtain or combustible materials. Do not install less than 5 feet above a floor. Do not install in damp or wet locations. Do not install concealed, or extended through building walls. Do not attempt to energize anything other than a track light fixture. This track system shall only be supplied with two single 120V, 60Hz, 20amp branch circuits. Do not load to more than 20 amps per circuit. Although track light systems may seem to operate acceptably, a dangerous overload of the neutral may occur and result in a risk of fire. Check with a qualified electrician before wiring. All of the installations shall be in accordance with NEC and all local codes. Save these installation instructions and refer to them when additions or changes to the track configuration are made. MOUNTING OPTIONS Generally, for any mounting method, do not exceed 4 feet between mounting points, and do not exceed 6 inches (for 4 feet of track or less in length) or 12 inches (for track that is greater than 4 feet) from each end of the single track section. Always use two or more mounting supports for each track length. A: STRAP MOUNTING Remove the End Cap and save. Slide the perforated hanger straps (not included, can be purchased in a hardware store) into the groove in the side of the track. An equal number of straps should be mounted on each side of the track. Wrap the straps around the building structure or nail the straps to the structure. They should be positioned evenly to balance the track. Placing one hanger strap every foot,per side is recommended. Push End Cap into the track at the end of the track and secure by screw. The hanger strap can be bought at a hardware store, recommend size is 11/16 inch (17mm) in width. Use clips or plates (by others) to be accommodated mounting on the 1/2 inch of the ceiling board. B: DIRECT MOUNTING Mounting slots in top of track can be knocked out and are spaced every 10 inches for convenience. Mount as shown using a mounting screw every 2 feet is recommended. Additional supports may be added for heavier load applications.

W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL C: SUSPENSION MOUNTING Slide or snap the hanger clips (WMT-RT) onto the track, and space the clips evenly along the track length. Secure the bolt and make sure the hanger clips tightly hook in the track groove. Assemble the stem or cable suspender (refer to WT/WHT track suspension system) to the hanger clips. Level track and secure to building structure. Recommended: two clips for 4 track, three clips for 8 track, and four clips for 12 track. Always use more than one clip for each track length. Additional clips may be added for more support. FEED OPTIONS Live End Connector can be fed directly from above using a 1/2 inch or 3/4 inch electrical connector. Make sure power is off before wiring. Note the polarity indicator of the track and accessories. Remove cover and save. Remove knockout in top plate. Secure conduit by conduit connector (1/2 or 3/4 size recommended) to top plate and lock the nut. Pass wires (12AWG) through conduit and connector. Cut and strip each end of the wire, then a single conductor is clamped directly under the head of the screw when it is tightened. The single conductor is bent around the screw in a 3/4 loop, insert the wires to the corresponding terminals (see fig. below) and secure tightly with a screw. Secure the track to the ceiling (see mounting options on previous page). Replace the cover. Insert the spline and secure to the track with two screws.

W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL OVER IMPEDIMENT ACCESSORY OPTIONS Make sure power is off before connecting. Note the polarity indicator of the track and accessories. Insert the spline to the track groove and secure with two screws.

W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL ACCESSORY OPTIONS Remove the end cap and save. Use a metal cutting power saw (preferably in a miter box) to cut the track, insulation material, and copper bus bars vertically with one straight cut. If the mounting openings are not in the proper position to secure after field cutting, use a power drill to drill an appropriate number of mounting holes. The holes should be 3/16 in diameter, and drill in the top centerline of the track along the track length. CAUTION: Remove any burrs that may have resulted from the cut or drill. There should be no burrs between the copper wires and the aluminum track housing. Replace the End Cap at the end of track and secure with a screw.

W Track Recessed 277V Flangeless WHT4-RTL, WHT8-RTL, WHT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying the system. Do not install within six inches of any curtain or combustible materials. Do not install less than 5 feet above a floor. Do not install in damp or wet locations. Do not install concealed, or extended through building walls. Do not attempt to energize anything other than a track light fixture. This track system shall only be supplied with two single 120V, 60Hz, 20amp branch circuits. Do not load to more than 20 amps per circuit. Although track light systems may seem to operate acceptably, a dangerous overload of the neutral may occur and result in a risk of fire. Check with a qualified electrician before wiring. All of the installations shall be in accordance with NEC and all local codes. Save these installation instructions and refer to them when additions or changes to the track configuration are made. MOUNTING OPTIONS Generally, for any mounting method, do not exceed 4 feet between mounting points, and do not exceed 6 inches (for 4 feet of track or less in length) or 12 inches (for track that is greater than 4 feet) from each end of the single track section. Always use two or more mounting supports for each track length. A: STRAP MOUNTING Remove the End Cap and save. Slide the perforated hanger straps (not included, can be purchased in a hardware store ) into the groove in the side of the track. An equal number of straps should be mounted on each side of the track. Wrap the straps around the building structure or nail the straps to the structure. They should be positioned evenly to balance the track. Placing one hanger strap every foot, per side is recommended. Push End Cap into the track at the end of the track and secure by screw. The hanger strap can be bought at a hardware store, recommend size is 11/16 inch (17mm) in width. Use clips or plates (by others) to be accommodated mounting on the 1/2 inch of the ceiling board. B: DIRECT MOUNTING Mounting slots in top of track can be knocked out and are spaced every 10 inches for convenience. Mount as shown using a mounting screw every 2 feet is recommended. Additional supports may be added for heavier load applications.

W Track Recessed 277V Flangeless WHT4-RTL, WHT8-RTL, WHT12-RTL C: SUSPENSION MOUNTING Slide or snap the hanger clips (WMT-RT) onto the track, and space the clips evenly along the track length. Secure the bolt and make sure the hanger clips tightly hook in the track groove. Assemble the stem or cable suspender (refer to WT/WHT track suspension system) to the hanger clips. Level track and secure to building structure. Recommended: two clips for 4 track, three clips for 8 track, and four clips for 12 track. Always use more than one clip for each track length. Additional clips may be added for more support. FEED OPTIONS Live End Connector can be fed directly from above using a 1/2 inch or 3/4 inch electrical connector. Make sure power is off before wiring. Note the polarity indicator of the track and accessories. Remove cover and save. Remove knockout in top plate. Secure conduit by conduit connector (1/2 or 3/4 size recommended) to top plate and lock the nut. Pass wires (12AWG) through conduit and connector. Cut and strip each end of the wire, then a single conductor is clamped directly under the head of the screw when it is tightened. The single conductor is bent around the screw in a 3/4 loop, insert the wires to the corresponding terminals (see fig. below) and secure tightly with a screw. Secure the track to the ceiling (see mounting options on previous page). Replace the cover. Insert the spline and secure to the track with two screws.

W Track Recessed 277V Flangeless WHT4-RTL, WHT8-RTL, WHT12-RTL OVER IMPEDIMENT ACCESSORY OPTIONS Make sure power is off before connecting. Note the polarity indicator of the track and accessories. Insert the spline to the track groove and secure with two screws.

W Track Recessed 277V Flangeless WHT4-RTL, WHT8-RTL, WHT12-RTL