Safety Switches with Separate Actuator SKC

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Safety switches for hinged doors

Safety switches with separate actuator

Safety switches with separate actuator

FL series position switches

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN BG-GS-ET-15

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Position switches FC series

Position switches FR series

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Position switches FR series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Safety switches for hinges

3SE3 1 SIGUARD Position Switches

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

AZM 161SK 12/12RKED/TU 024

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

3SE3 2 SIGUARD Position Switches

Position switches FD series

Safety door-handle system STS

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Safety switches with solenoid and separate actuator

SIGUARD Safety Systems Safety Integrated

LK Position Switches TECHNICAL DATASHEET.

Safety switches for hinged doors

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Safety switches / Position switches / Command devices

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Safety rope switches with reset for emergency stop

Safety rope switch with reset for emergency stop

SG-B1 SERIES / SG-A1 SERIES

HS6B Series Subminiature Interlock Switch

LR-LX-LK-LW Safety Switches with separate actuator

Safety rope switch without reset for simple stop

AF40... AF96 3-pole contactors Technical data

HS5D Miniature Interlock Switches

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

EStrong-series Emergency Stop

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Switches with manual reset

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Safety switches with solenoid and separate actuator

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Single foot switches PX and PA series

Limit Switch - Prewired Type Metal Body

Single foot switches - PX and PA series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

TAE pole Contactors

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Door Interlock Switches

HS5D Miniature Interlock Switches

Limit Switches - Limit Type Plastic Body IP65

HS1C Interlock Switches with Solenoid

SFS-UFS Single Foot Switches

Prewired position switches FF series

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Limit Switches - Limit Type Plastic Body IP65

Position Switches Series 8074/2

Door Interlock Switches

BETA Switching Switches and Light Indicators

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Microswitches M series

HS1E Series Full Size Solenoid Locking Switches

Safety Switches Series 8537

Miniaturized limit switches

HS1L Interlock Switches with Solenoid

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

Floor and fine adjustment switches

F3S-TGR-KHL1/-KHL3/-KHL3R

Safety Limit Switches

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Gross Automation (877)

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

HS5E Miniature Interlock Switches with Solenoid

Single foot switches PX and PA series

Standard Interlock Safety Switches

Transcription:

Plastic encased safety interlocking switch Type PSEN me2/psen me3 Intended use The plastic encased safety switches PSEN me2 and PSEN me3 with separate actuator are suitable for the mounting on safety guards. They are designated to trigger switching operations in control circuits. Function If the safety guard is opened the contact(s) with forced disconnection contacts get opened). will break the safety control circuit (safety Safety instructions Improper installation or manipulation of the safety switch renders the personal protection function useless and can cause serious injury or accidental death. In order to maintain the maximum level of safety, always order and use actuators together with the correct safety switches. Dimensions [mm] cylindrical screw M5 DIN 912 Ø5,5 fixed position for safety application Date of issue: 31.01.2005 / Page 1 of 5

PSEN me2as Actuating forces : 10 N 100 N Actuator PSEN me2ar Actuating forces : only 10 N protective cover The protective cover must be latched onto the actuator after mounting. The protective cover prevents the actuator from being easily dismantled and also provides protection against overtravel of the actuator in case of not proper installed mechanical end stops for the guard. Rmin. in adjusting direction 50 mm Rmin. in adjusting direction 50 mm Minimum radii reference to a point of rotation on enclosure top edge S 0 Minimum radii reference to a point of rotation on enclosure top edge S 0 Mounting dimension for all actuators: 40 mm with M5- screws acc. DIN 912! Installation Installation by trained and qualified personnel only! To mount the switch gear 2 screws M5 shall be used. Actuator PSEN me2as and PSEN me2ar: The user shall make sure that the actuator is form-fit mounted. The actuator mounting should not be solvable with simple tools. The mounting requires 2 screws M5 acc. DIN 912. The switch and the actuator shall be aligned during installation in such a way that the maximum permitted misalignment with closed safety guard, which is stated in the drawing, will not be exceeded. The actuator PSEN me2ar has to be adjusted in such a way that the actuator can be inserted into the switch head without significant lateral forces. The mounting position is any desired but shall support inspection and replacement if necessary by qualified personnel. Choose such a mounting position that no foreign parts seep into the opening of the actuating device. The rated degree of protection (IP-Code) of the switch applies only with closed cover lid and when an at least evenly matched cable gland with adequate cable is used. The switches shall not be used as mechanical end stops. Date of issue: 31.01.2005 / Page 2 of 5

The safety switch shall not be used as mechanical end stop! Position of mechanical stop adjustable (not supplied with safety switch) 4 different directions of actuation by turning the cap in position A or B: 1. remove the actuator 2. open cover lid 3. snap of cap 4. remove cap 5. turn cap 6. latch cap 7. for fixing the cap close cover lid Actuating forces (Extraction force): Standard = 10 N PSEN me2.1, PSEN me3.01, PSEN me3.11, PSEN me3.21 = 100 N Cover for unused entry Mounting M20/M16 cable gland/cable: Connection type: 2 or 4 screw connectors M3,5 or 6 screw connectors M3 Conductor cross section: single core 0,5-1,5 mm²/litz wire with connector sleeve 0,5-1,5 mm² After mounting the gland remove the piece inside Electrical connection The electrical connection shall only be carried out by trained and qualified personnel! The electrical contacts of the switches PSEN me2 and PSEN me2.1 feature 2 screw terminals M3,5. Tightening torque M = 0,8 Nm. The electrical contacts of the switches PSEN me3, PSEN me3.01, PSEN me3.1 and PSEN me3.11 feature 4 screw terminals M3,5. Tightening torque M = 0,8 Nm. The electrical contacts of the switches PSEN me3.2 and PSEN me3.21 feature 6 screw terminals M3. Tightening torque M = 0,6 Nm. The connection requires a stranded wire with ferrule or a solid wire with a cross section of 0,5 1,5 mm². For safety circuits acc. EN 60204 use the normally closed contact(s) (N.C.) only. Date of issue: 31.01.2005 / Page 3 of 5

PSEN me2 PSEN me3 PSEN me3.1 PSEN me3.2 Electrical data PSEN me2.1 PSEN me3.01 PSEN me3.11 PSEN me3.21 Switching function 1 NC (Y) 1 NO/1 NC (Zb) 2 NC (Zb) 1 NO/2 NC (Zb) Switch symbol Rated insulation voltage U i 250 V AC 250 V AC 250 V AC 400 V AC Conventional thermal current I the 5 A 10 A 10 A 5 A Utilization category acc. IEC/EN 60947-5-1 240 V/1,5 A 240 V/3 A 240 V/3 A 240 V/1,5 A Type of short-circuit protection 6 A gl/gg 10 A gl/gg 6 A gl/gg 6 A gl/gg Melting fuse acc. IEC/EN 60947-5-1, annex K Forced disconnection (N.C.) IEC/EN 60947-5-1 Degree of protection II, protective insulation Mechanical data Enclosure Thermoplastic, glass fiber reinforced (UL94-V0) Cover Thermoplastic, glass fiber reinforced (UL94-V0) Ambient air temperature -30 C to +80 C, -22 F to +176 F Cable entry PSEN me2, PSEN me2.1 3 x M16x1,5 PSEN me3, PSEN me3.01 3 x M20x1,5 PSEN me3.1, PSEN me3.11 3 x M20x1,5 PSEN me3.2, PSEN me3.21 2 x M20x1,5 Protection class IP65 acc. EN 60529; DIN VDE 0470 T1 Weight PSEN me2 0,1 kg PSEN me3 0,13 kg Actuating device 2AS 2AR Actuator Separate actuator (St stainless) Actuating radius 150 mm 50 mm Actuating speed 0,2 m / s Extraction force Standard 10 N PSEN me2.1, PSEN me3.01, PSEN me3.11, PSEN me3.21 100 N Mechanical life 1 x 10 6 switching cycles Mechanical life, extended actuation force 1 x 10 5 switching cycles Switching frequency 30/minute Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 GS-ET-15 EU-Conformity Approvals BG (applied for) UL/CSA A300 (applied for) for PSEN me3, PSEN me3.01, PSEN me3.1, PSEN me3.11 UL/CSA B300 (applied for) for PSEN me2, PSEN me2.1, PSEN me3.2, PSEN me3.21 Date of issue: 31.01.2005 / Page 4 of 5

Start-up Mechanical function test: Actuate the safety guard und check the proper switching function. Electrical function test in the safety control circuit: - Opening the safety guard shall break off the energy of the drive. - The drive shall only be energized when the safety guard is in its closed position. Maintenance / Inspection The switching device is maintenance-free. For trouble-free operation and a long service life the device should be inspected regularly. Ensure that: - all components are secure and tight - switching functions operate properly - all sealing gaskets are in proper condition - the components show no signs of tear and wear. If defects are detected the complete switching device and the actuator have to be replaced. Liability disclaimer By breach of the given instructions (concerning the intended use, the safety instructions, the installation and connection through qualified personnel and the testing of the safety function) any liability expires. Date of issue: 31.01.2005 / Page 5 of 5