Modular line 042 1/4. Regulator. Regulator

Similar documents
Air treatment filter EZF G 3/8 - G 1/2 - G 1

Air Preparation Products

Series Airplus Size 1

Air Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off

with interchangeable cartridges: 1/8, 1/4 and 3/8 threaded or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm

Series 1700 Size

Air service units series X G1/4 to G3/4

Series 1700 Size 1 1.8

Air service units filters, regulators and lubricators

Air Service Units Filter pressure regulator + Lubricator - Size 1. Series Technical characteristics. Construction and working characteristics

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

Modular FRLs. Pneumatic Mini Series G 1 /8 - G 1 /4. Modular Junior Series G 1 /8 to G 3 /8 Modular Maxi Series G 1 /4 to G 3 /4 Modular Series G1

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

FILTERS, REGULATORS & LUBRICATORS

AIR PREPARATION PRODUCTS. Table of Contents

IC3A, IC3D, IC4A and IC4D ISO Spirax-Monnier International Ultraclean Compressed Air Filters

P3Y Series Air preparation system. 3/4 & 1 Body ported

Air Preparation Products 652 Series Filter Regulator (FR) for Process Industry Applications

MX2 ports: G3/8, G1/2, G3/4 - MX3 ports: G3/4, G1 Modular Bowl with technopolymer cover and bayonet-type mounting

AIR TREATMENT ACCESSORIES

50 SERIES FILTER F50B Series F50B-04 pictured Application ANSI SYMBOL Primary air filters are designed to separate liquid, water, rust, pipe scale, an

MOUNTING BRACKETS. Dimensional Drawing - Mounting Options

Filters, regulators, and lubricators

A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

AUTOMATION TECHNOLOGY. Air Preparation Units

Port Size. Connection G1/8 G 1/4 G 3/8 G 1/2 G 3/4 G 1. Standard nominal flow rate * 3000 I/min I/min I/min I/min I/min.

Air preparation units

COMPONENTS FOR OIL-FIRED HEATING

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

BL84 - Excelon Plus Modular System Filter/regulator - Lubricator Combination Units

F84C - Excelon Plus Modular System Oil removal filter

Parker Global Air Preparation System

F84G - Excelon Plus Modular System General purpose filter

F64G. Typical flow with 40 µm element at 90 psig (6.3 bar) inlet pressure and a 5 psig (0.35 bar) pressure drop. F64G- N - D 1/4 2 3/8 3 1/2 4 3/4 6

FILTER, REGULATOR AND FILTER/REGULATOR stainless steel 316L compact 1/4, high flow 1/4-1/2

3000 Series filters 3/4" and 1" Ports

PURESTREAM -FRL PURESTREAM - FRL. Installation / Operating / Maintenance Instructions Filter Series F1. Specifications.

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Drain Type Semi-Automatic

Dimensional Drawing - Mounting Options

CORRECT SELECTION OF COMPRESSED AIR PROCESSING EQUIPMENT

SUCTION FILTRES. 3D drawings available at

FILTER, REGULATOR AND FILTER REGULATOR stainless steel 316L compact 1/4, high flow 1/4, 1/2, 3/4 and 1

ES20 Compact Sampling System Stainless Steel Sampling System

Model Model 815

L1000/L3000/L4000/L8000-W Series

Page General Purpose Filter Replacement Filter Elements Bowl Assemblies Accessories & Optional Extras

LMP series

PA-S small filter. Technical Data G 1/8

Air preparation units

AIR PREPARATION PRODUCTS F.R.L. 3 PCS Combination F.R.L. 2 PCS Combination Filter - Regulator

[Small diaphragm vacuum pumps]

Technical Information

Parker Global Air Preparation System. A complete air preparation system

Air preparation units

In line high pressure filters. HF 725 series

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Moduflex FRLs. Moduflex40 P3H Series 1/8 and 1/4 ported. Moduflex60 P3K Series 3/8 and 1/2 ported. Moduflex80 P3M Series 1/2, 3/4 and 1 ported

VALVES. Wilkerson. Filters, Regulators & Lubricators. dixonvalve.com Customer Service:

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

F.R.L. unit modular type

300 Series INSTRUCTION MANUAL. Compressed Air Filters Models 302 (grade) through 317 (grade)

PLC-3000 zfa01. Portable Fluid Analysis. Global Filtration Technology

Compressed Air Cleaning Filter Series

Gauges, Sight Glasses and Vacuum Breakers

To ensure proper installation, digital pictures with contact information to before startup.

F64C, F64H - Olympian Plus Plug-In System Puraire high efficiency coalescing filter

Type 730 Diaphragm Valves

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

Air preparation units

Compressed Air Cleaning Filter Series

The P3Y Modular FRL System

Filters for Compressed Air

FRL/AirCare Air Controls & Accessories

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

2009 PRICE LIST. Prices FOB Ft. Myers, FL. Effective May 15, Subject to change without notice Suggested MODEL PORT SIZE HP RANGE

Model Model Model

COILS, CONNECTORS, SOLENOID VALVES

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Return / Suction fi lters Tank mounted. MRSX series. Maximum pressure up to 10 bar - Flow rate up to 300 l/min. Return / Suction fi lters

In line high pressure filters. HF 735 series

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

Stainless Steel FRLs

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

FR14MD FR18MD. Modular filter-regulators, suitable for compressed air. FEATURES Filter-regulator for inlet pressure up to 30 bar (435 psi).

Inside. Introducing GROZ Air - air control units. Air Regulators 05. Air Lubricators - Metal Bowl 09. Filter Regulator Combination 10.

1 6 / 2 6 S E R I E S C O M P A C T & S T A N D A R D M O D U L A R A I R P R E P A R A T I O N S Y S T E M S

Table of Contents. Proportional & Precision Regulator Instrumentation

AIRMIX PUMP and LOW-PRESSURE PUMP air motor with reversing block

I-4057-F CleanAir Air Control Equipment. Accessories for superior spray finishing. Filters Regulators Gauges Valves WATERBORNE COMPATIBLE

WARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.

Balston Stainless Steel Compressed Air Filters for Food Processing and Packaging

F14MD F18MD. Modular filters, suitable for compressed air FEATURES. Filter for inlet pressure up to 30 bar (435 psi).

Components for central heating

Introduction to Inline Lubrication. Master Pneumatic

Pneumatic Quick Reference Guide

Manual for 12 Sand Filter/ Pump Combo Unit.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Transcription:

1 Modular line 1/ Regulator 5..5 3..3 1..1 3,5 1 7 INLET PRESSURE = 1 (1 ),3,,5 1,5 3 1 8 17,5 1 15 1 Regulator * Sensitive high performance model with rolling diaphragm; high stability with low load losses and big flow rate. * Can be wall mounted using the relative holes or a bracket. * Lockable safety knob. * Built-in overpressure relieving function. * Pressure ranges:, 8 (standard), 1,5,,,8 (standard), 1,5 * Maximum inlet pressure: 1, (1, ). * Temperature range: 5 5 C (1 1 F). * Gauge connection: G1/8. * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=,3 - p=1 ): 85 Nl/min. * Weight:,15 Kg. REGULATION FEATURES CONSTANT FLOW RATE= dm 3 /s( Nl/m).,3 5.5 3..3. 1.1,5,....8 8 1. 1 INLET PRESSURE 8 7.8.7 RELIEVING PERFORMANCES,3 5 3..3..1..5,5,.1. 1.3 18..5 3 15

Modular line 1/ Filter Filter 1..8 PRESSURE DROP....1.8..., 5 FILTERING ELEMENT = MICRONS,,3,5 8,3 5 1,5 75 1, 1,8 15 1, 5 15 * High level of condensate separation. * Low pressure drop. * Can be wall mounted using the relative holes. * Filtering degree: 5 micron and micron (standard). * Manual and semiautomatic condensate drainage in the integrated (SS) or float type automatic version (SA). * Bowl available in two configurations: transparent toughened polyamide or with outer bowl guard. * Collected quantity of condensate: cc. * Maximum operating pressure: 1, (1, ). * Temperature range: 5 5 C (1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=1 - p=1 ): 15 Nl/min. * Weight:,95 Kg. 1

Modular line 1/ Microfilter PRESSURE DROP 1..8....1.8... FILTRATION EFFICIENCY OF 99,99 % WITH PARTICLES OF,1 MICRONS.5 3 1. 1.5 9,5,,3 Coalescent Cartdridge. 1.5 15 3. 18 Coalescent oil-proof microfilter Essential in circuits where oil is not permitted. * Coalescent cartridge made in microfiber, allows an high filtration efficiency of 99,99% on,1 micron particles. * Can be wall mounted using the relative holes. * Manual and semiautomatic condensate drainage in the integrated (SS) or float type automatic version (SA). * Bowl available in two configurations: transparent toughened poliamide or with outer bowl guard. * It is advisable to install a filter with 5 micron element, to consent long-lasting of coalescent cartridge. * Maximum operating pressure: 1, (1, ). * Temperature range: 5 5 C (1 1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=,3 - p=1 ): 195 Nl/min. * Weight:,95 Kg. FUNCTIONING The air with impurity enter into the special cartridge with high efficiency, that stop solid particles, capture and join outside particles of oil and condensate (coalescent effect). In this way, they easily fall down at the bottom of the bowl, where condensate is discharged. Filtered air obtained is without solid and liquid parts. 17

Modular line 1/ Lubricator Lubricator PRESSURE DROP 1..1.8.8......,3 375,5,,3 1,5 75 18,8 5 15 115 31,3 1875 1, 37,5 5 Proportional oil mist type. * Constantly steady delivery. * Suction ensured even with low flow rates. * Sensitive lubricant flow adjustment. * 3 drip display. * Oil fill plug. * Can be wall mounted using the relative holes. * Bowl available in two configurations: transparent toughened polyamide or with outer bowl guard. * Bowl capacity: cc. * Recommended oil viscosity ISO VG3. * Maximum operating pressure: 1, (1, ). * Temperature range: 5 5 C (1 1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=1 - p=1 ): Nl/min. * Weight:,95 Kg. MINIMUM OPERATING FLOW Inlet Pressure Minimum Air Flow Psi dm 3 /s (ANR) Nl/1' (ANR) SCFM 3,5,5,3.77 58,,,3.9 91,3,3,5 3 1.5 18

Modular line 1/ Lubricator VL Automatic filling lubricator 1..1.8.8. PRESSURE DROP.....,3 375,5,,3 1,5 75 18,8 5 15 115 31,3 1875 1, 37,5 5 Essential when the oil must be quickly and safety loaded without interrupting the normal operation of the system. * Filling is achieved by keeping the button at the base of the lubricator casing depressed. This provokes a vacuum inside the bowl enabling the oil to be intaken. * The flow will only interrupt when the button is released. * The oil level must be visually inspected. * Minimum attivation pressure: 3 (,3 ). * Other functional features as standard model. * Reference flow rate (P=1 - p=1 ): Nl/min. * Weight:,1 Kg. MINIMUM OPERATING FLOW Inlet Pressure Minimum Air Flow Psi dm 3 /s (ANR) Nl/1' (ANR) SCFM 3,5,5,3.77 58,,,3.9 91,3,3,5 3 1.5 19

1 Modular line 1/ Filter regulator 5 3 1..5..3..1 5..5 3,5 1 INLET PRESSURE = 1 (1 ),3,,5 7 1,5 3 1 8 REGULATION FEATURES CONSTANT FLOW RATE= dm 3 /s( Nl/m),3 17,5 1 15 1 Filter regulator * Sensitive high performance model with rolling diaphragm; high stability with low load losses and big flow rate. * Can be wall mounted using the relative holes or on brackets. * Lockable safety knob. * Built-in overpressure relieving function. * High level of condensate separation. * Pressure ranges:, 8 (standard), 1,5,,,8 (standard), 1,5 * Filtering degree: 5 micron and micron (standard). * Manual and semiautomatic condensate drainage in the integrated (SS) or float type automatic version (SA). * Bowl available in two configurations: transparent toughened polyamide or with outer bowl guard. * Collected quantity of condensate cc. * Maximum operating pressure 1, (1, ). * Temperature range 5 5 C (1 1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=,3 - p=1 ): 85 Nl/min. * Weight:,1 Kg. 3..3.,5, 1.1....8 8 1. 1 INLET PRESSURE 8 7.8.7 RELIEVING PERFORMANCES,3 5 3..3..1..5,5,.1. 1.3 18..5 3

Modular line 1/ 3 Way on-off valve 1 8 1,,8,,,.5 7 9 5,3,,5 13.5 81 18 18.5 135 1, 7 1 3 Way on-off valve with lock Used to shut off the air supply while relieving the downstream circuit. * The block device is particularly useful during maintenance operations. It prevents the system from being accidentally or wrongly pressurized. * It can be wall mounted using the relative holes. * Discharge connection: G 1/8. * Maximum inlet pressure: 1, (1, ). * Temperature range: 5 5 C (1 1 F). * The device is equipped with 1 lock. * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=1 - p=1 ): 157 Nl/min. * Weight:,155 Kg. 1

Modular line 1/ Shut-off valve Shut-off valve 1 8 1,,8,,,.5 7,3, 9 5 13.5 81 18 18.5 135 1, 7 1 Device used to shut off the air supply while relieving the downstream circuit by a remote electric control. * Available with MICROSOL type or in compliance with CNOMO standards (to be ordered separately). * Available with remote pneumatic control. * It can be wall mounted using the relative holes. * Discharge connection: G1/8". * Minimum pressure admitted: 3 (,3 ). * Maximum working pressure: 1 (1 ). * Temperature range: 5 5 C (1 1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=1 - p=1 ): 157 Nl/min. * Weight:,189 Kg. Microsol Control Cnomo Control Pneumatic Control

Modular line 1/ Slow start valve Slow start valve 1 8 1,,8,,,.5 7,3, 9 5 13.5 81 18 18.5 135 1, 7 1 Gradually pressurizes the system until reaching the set operating pressure value. * Before delivering the maximum available pressure, the air is allowed to slowly flow around the downstream circuit until about % of the pressure is reached upstream. * Use the built-in flow governor to establish the pressurizing time. * It can be wall mounted using the relative holes. * Minimum pressure admitted: 3 (,3 ). * Maximum working pressure: 1 (1 ). * Temperature range: 5 5 C (1 1 F). * Max. torque inserts G1/ IN-OUT: 5 N m. * Reference flow rate (P=1 - p=1 ): 157 Nl/min. * Weight:,13 Kg. 3

Modular line 1/ Assembling system The new line is characterized by a high versatility thanks to the double assembling system. Infact, the usual UNIT ASSEMBLING KIT (see picture 1) is utilized for assembling standard combined units such as FR+L, V3+FR+L, F+R+L, F+L e F+MF. Besides being really practical and functional, this unit assembling kit reduces to the minimum the assembled unit overall dimensions. Whereas, the BATTERY ASSEMBLING KIT (see picture ) is utilized for assembling particularly complex groups. This battery assembling kit, which is preassembled on single standard products, allows the realization of innumerable combinations so as to actually meet the most demanding application requirements. Fig.1 Fig. Battery assembling kit T bracket kit Lubricator Slow start valve Shut-off valve Filter regulator 3 way on-off valve with lock

Modular line 1/ Order Code Guide to references FR 8 S Line Special Type V = Vacuum loading Product R = Regulator F = Filter L = Lubricator FR = Filter regulator Drain S = Manual and semi-automatic (standard) A = Automatic V3 = 3 Way on-off valve SV = Shut-off valve AVP = Slow start valve Connection = 1/ Filtering element 5 = 5 micron = micron 1 =,1 micron Range of pressure = 8 = 8 1 = 1 Regulator R R R 8 R R 1 R Regulator 1/" Regulator 1/" 8 Regulator 1/" 1 Lubricator L L V Lubricator 1/" Lubricator 1/" - Vacuum loading Filter F S F A F 5 S F 5 A Filter 1/" mic Semi Filter 1/" mic Auto Filter 1/" 5mic Semi Filter 1/" 5mic Auto Filter regulator FR R S FR 8 R S FR 1 R S FR 5 R S FR 5 8 R S FR 5 1 R S FR R A FR 8 R A FR 1 R A FR 5 R A FR 5 8 R A FR 5 1 R A Filter/Reg. 1/" mic Semi Filter/Reg. 1/" mic 8 Semi Filter/Reg. 1/" mic 1 Semi Filter/Reg. 1/" 5mic Semi Filter/Reg. 1/" 5mic 8 Semi Filter/Reg. 1/" 5mic 1 Semi Filter/Reg. 1/" mic Auto Filter/Reg. 1/" mic 8 Auto Filter/Reg. 1/" mic 1 Auto Filter/Reg. 1/" 5mic Auto Filter/Reg. 1/" 5mic 8 Auto Filter/Reg. 1/" 5mic 1 Auto = Standard version 5

Modular line 1/ Order Code 3 Way on-off valve Shut-off valve IV Isolation Valve 1/" IV S/P Isolation Valve 1/" Solenoid/Pneu. Control C5.. Sol. Kit for IV S/P-VDC C5..3 Sol. Kit for IV S/P-VAC C5.. Sol. Kit for IV S/P-11VAC C5..5 Sol. Kit for IV S/P-VAC C..1 Pneumatic Control kit for IV S/P IV C Isolation Valve 1/" CNOMO Control C..11 3/ Way Sol. Valve for IV C A5.. Coil DC V Sp.=mm A5..7 Coil AC V Sp.=mm A5..8 Coil AC 11V Sp.=mm A5..9 Coil AC V Sp.=mm A5..1 Connector mm FR+L Unit FR+L S FR+L 1/" mic Semiauto FR+L 8 S FR+L 1/" mic 8 Semiauto FR+L 1 S FR+L 1/" mic 1 Semiauto FR+L 5 S FR+L 1/" 5mic Semiauto FR+L 5 8 S FR+L 1/" 5mic 8 Semiauto FR+L 5 1 S FR+L 1/" 5mic 1 Semiauto FR+L A FR+L 1/" mic Auto FR+L 8 A FR+L 1/" mic 8 Auto FR+L 1 A FR+L 1/" mic 1 Auto FR+L 5 A FR+L 1/" 5mic Auto FR+L 5 8 A FR+L 1/" 5mic 8 Auto FR+L 5 1 A FR+L 1/" 5mic 1 Auto FR+L 8 S V FR+L 1/" mic 8 SA Vac Load FR+L 1 S V FR+L 1/" mic 1 SAVac Load FR+L 5 8 S V FR+L 1/" 5mic 8 SA Vac Load FR+L 5 1 S V FR+L 1/" 5mic 1 SA Vac Load FR+L 8 A V FR+L 1/" mic 8 A Vac Load FR+L 1 A V FR+L 1/" mic 1 A Vac Load FR+L 5 8 A V FR+L 1/" 5mic 8 A Vac Load FR+L 5 1 A V FR+L 1/" 5mic 1 A Vac Load Slow start valve SS Slow Start 1/" = Standard version

Modular line 1/ Order Code Spare parts Diaphragm complete PROD. VERSION C.1.13 R - FR RELIEVING C.1.1 R - FR NON RELIEVING Bowl for lubricator PROD. VERSION C.3.8 L TT C.3.8 L PE C.3.11 VL TT C.3.117 VL PE Regulation spring Bowl for filter PROD. SET REGULATION A38.. MR - R - FR A38.. MR - R - FR 8 A38..1 MR - R - FR 1 PROD. VERSION C.. F - FR - MF TT SS C..18 F - FR - MF PE SS Filtering element PROD. VERSION C..11 F MICRON C..1 FR MICRON C..1 F 5 MICRON C..5 FR 5 MICRON C..53 MF,1 MICRON Oil window C.3.5 PROD. L Bowl with automatic drain PROD. VERSION C..133 F - FR - MF TT SA C..13 F - FR - MF PE SA Oil plug with OR 31 C75.3.11 PROD. L Automatic drain C..13 PRODUCT F - FR - MF Mounting kit for automatic drain C..131 PRODUCT F - FR - MF Gauge Psi A B CH. A38.. 1 175 G1/8 1 A38..55 85 G1/8 1 7

Modular line 1/ Order Code Kit assembling units Plug PRODUCT CONNECTION C.5.1 F+R+L - V3+FR+L B38..18 G1/8 C..1 FR+L A.1.1 G1/ (air takeoff) C.7.1 F+L - F+MF Battery assembling kit C..1 19 Air takeoff for units CONNECTION PRODUCT C.5.1 1/8 F+R+L - FR+L V3+FR+L - F+L - F+MF C.5.18 1/ F+R+L - FR+L V3+FR+L - F+L - F+MF C.5.13 WAYS (1/ -1/8 ) F+R+L - FR+L V3+FR+L - F+L - F+MF Battery air take-off C.5.3 CONNECTIONS n 1 G1/ - n G1/8 Distribution block for two regulators C.5.111 Bracket C38..9 T bracket kit C.5.1 8