CONTINUOUS 3520 ekw 4400 kva 50 Hz 1000 rpm

Similar documents
STANDBY 2860 ekw 3575 kva 50 Hz 1000 rpm

PRIME 3880 ekw 4850 kva 50 Hz 1000 rpm

DIESEL GENERATOR SET FEATURES

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

DIESEL FEATURES GENERATOR SET

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Voltage 220 to or 1800 RPM

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

400 to 11,000 Volts. Standby, Prime, Continuous

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

3412C Generator Set Electric Power. Specifications. Benefits and Features

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

3516B Generator Set Electric Power

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

C32 ACERT Generator Set Electric Power

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Specifications. 3406C Generator Set Electric Power

PRIME 225 ekw 281 kva

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 4000 ekw 5000 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

3516B Offshore Generator Set

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 480 ekw 600 KVA

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 400 ekw 500 kva

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

Specifications. C13 Generator Set Electric Power

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

Prime 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

Mission STANDBY Critical Standby 2000 ekw 2500 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

C280-6 Offshore Generator Set

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 320 ekw (400 kva)

Transcription:

DIESEL GENERATOR SET CONTINUOUS 3520 ekw 4400 kva Image shown may not reflect actual package Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES FUEL/EMISSIONS STRATEGY Low BSFC FULL RANGE OF ATTACHMENTS Wide range of bolt-on system expansion attachments, factory designed and tested Flexible packaging options for easy and cost effective installation SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Cat S O S SM program effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by products. 3612 DIESEL ENGINE Reliable, rugged, durable design Four-stroke diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT GENERATOR Matched to the performance and output characteristics of Cat engines CAT GENERATOR SET MONITORING SYSTEM (GSM) Simple user friendly interface and navigation Provides protection, monitoring, and control of the diesel generator set. Redundant shutdown protection

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Aftercooler, fresh water, corrosion resistant coated (air side) Air inlet shutoff Air Cleaner Breather, crankcase, top-mounted Turbocharger, watercooled, engine oil lubricated [ ] Soot Filter [ ] Air cleaner Louver Assembly [ ] Vertical Support Bracket [ ] Heavy Duty Air Cleaner [ ] Air Inlet Adapter [ ] Boost Control Valve Cooling Exhaust Engine coolant water drains Front Mounted Turbos Three-bundle oil cooler. Water Temperature Regulator Jacket Water Thermostats 457 mm (18 in) Cat bolt pattern Dry, gas tight, exhaust manifold Includes adapter, flexible exhaust fitting [ ] Heat Exchanger for single circuit [ ] Heating Aids [ ] Cooling System Aids [ ] Auxiliary Water Pump [ ] Expansion Tank [ ] Flexible Exhaust Fittings [ ] Weld Flange and Related Hardware Fuel Simplex or Duplex [ ] Fuel Priming Pump [ ] Duplex Primary Fuel Strainer [ ] Fuel System Connections Generator Custom Generator Per Generator Data Sheet Completed by Dealer [ ] 3 Phase, six leads, WYE [ ] Class F insulation [ ] Bus bar connections [ ] Winding temperature detectors [ ] Anti-condensation space heaters Governor UG Actuator [ ] Electronic/ Actuators [ ] Digital Programmers [ ] Battery Backup/Power Supply [ ] 230 UA [ ] 723 Plus [ ] EGB Actuator Lube Mounting Starting / Charging General Centrifugal oil filters with single shutoff Service side engine mounted on cylinder block inspection covers Wet oil sump. Includes engine-driven main lubrication pump, installed oil lines, engine-driven oil pump and oil pan. Oil filler and dipstick Valve, oil pressure regulating Valves, crankcase explosion relief Damper, torsional vibration Engine and Generator Mounting Vane type air starter Two motors, engine mounted at rear, on left side Includes air silencer Line Group for Single Point Custom Connection Paint, Caterpillar yellow Pumps, gear driven: fuel, oil, jacket water, aftercooler/oil cooler water [ ] Oil Pan Drain valve [ ] Lube ANSI adapter (Emergency Connection) [ ] Isolator [ ] Spring type vibration isolator [ ] Vertically Restrained [ ] Non-vertically Restrained [ ] Pressure Reducing Valve [ ] Compressed Air Flex Hose [ ] Turbine Type Air Starters [ ] Redundant Air Starters [ ] Custom Paint Colors 2

SPECIFICATIONS CAT GENERATOR Excitation. Permanent Magnet Pitch. Optimum Number of poles..6 Number of bearings...two Bearing Insulation Normal Class F or H IP rating..drip proof IP23 Over speed capability - % of rated 125% Wave form deviation...3 % Voltage regulator. 3 phase sensing with load adjustable module CAT DIESEL ENGINE 3612, V-12, 4 stroke, water-cooled diesel Bore 280 mm(11.0 in) Stroke 300 mm (11.8 in) Displacement per cylinder 18.5L (1127 in 3 ) Total Displacement... 222L(13,524 in 3 ) Compression ratio.. 13:1 Aspiration...TA Fuel system..direct Unit Injection Generator Set Monitoring System (GMS) Features: 10 inch (254 mm) color monitor to display all engine parameters and alarm annunciation Annunciation of all engine shutdowns, alarms, and status points Start/prelube control switch, fuel control switch and emergency stop buttons Speed control switch with automatic changing to ball head control when a governor failure occurs, if ball head control is available. Contacts are available for customer use. Selection of local/remote control of engine Selection of idle/rated control of engine. Equipped for remote communication Four 4-20mA outputs (programmable) Relay contract signals to the remote monitoring system (summary shutdown, summary alarm, local operation/remote, engine running, PLC failure, fuel control and idle/rated). 3

TECHNICAL DATA Open Generator Set - 1000 rpm/50 Hz NOTES CONTINUOUS DM5406-06 RATING Engine Power Generator Power Engine efficiency (ISO 3046/1) Engine efficiency (nominal) (2) (2) 3700 bkw 3520 ekw 42.4 % 41.2 % ENGINE DATA Fuel Consumption (ISO3046/1) Fuel Consumption (nominal) Fuel Consumption (90% confidence) Air Flow (@ 25 C, 101.3 kpaa) Air Mass Flow Compressor Outlet Pressure Compressor Outlet Temperature Inlet manifold Pressure Inlet Manifold Temperature Timing Exhaust Stack Temperature Exhaust Gas Flow (@stack temp, 101.3kPa) Exhaust Gas Mass Flow (10) 196.0 g/bkw-hr 199.8 g/bkw-hr 202.2 g/bkw-hr 329.6 m3/min 22063 kg/hr 199.5 kpa(abs) 169.2 C 196.9 kpa(abs) 63.7 C 22.5 BTDC 447.9.0 C 1614.6 m3/min 22819 kg/hr ENERGY BALANCE DATA (nominal) Fuel Input Energy (LHV) Heat Rej. To jacket water Heat Rej. To atmosphere Heat Rej. To oil cooler Heat Rej. To EXH. (LHV to 25 C) Heat Rej. To EXH. (LHV to 177 C) Heat Rej. To aftercooler (4) (5) (6) (4) (4) (7), (8) 8991 KW 755 KW 180 KW 409 KW 3086 KW 1732 KW 835 KW EMISSIONS NO x (as NO) CO THC (molecular weight of 13.018) Particulates (9) (3) (3) (9) 20.7 g/bkw-hr 0.9 g/bkw-hr 1.0 g/bkw-hr 0.4 g/bkw-hr CONDITIONS AND DEFINITIONS ENGINE RATING OBTAINED AND PRESENTED IN ACCORDANCE WITH ISO 3046/1 AND SAE J1995 JAN90 STANDARD REFERENCE CONDITIONS OF 25 C, 100 KPA, 30% RELATIVE HUMIDITY AND 150M ALTITUDE AT THE STATED AFTERCOOLER WATER TEMPERATURE. CONSULT ALTITUDE CURVES FOR APPLICATIONS ABOVE MAXIMUM RATED ALTITUDE AND/OR TEMPERATURE. PERFORMANCE AND FUEL CONSUMPTION ARE BASED ON 35 API, 16 C FUEL HAVING A LOWER HEATING VALUE OF 42.780 KJ/KG USED AT 29 C WITH A DENSITY OF 838.9 G/LITER. NOTES 1) FUEL CONSUMPTION TOLERANCE. ISO 3046/1 IS 0, + 5% OF FULL LOAD DATA. NOMINAL IS ± 3 % OF FULL LOAD DATA. 2) ENGINE POWER TOLERANCE IS ± 3 % OF FULL LOAD DATA. 3) EMISSION DATA SHOWN ARE NOT TO EXCEED VALUES. 4) HEAT REJECTION TO JACKET AND EXHAUST TOLERANCE IS ± 10% OF FULL LOAD DATA. (heat rate based on treated water) 5) HEAT REJECTION TO ATMOSPHERE TOLERANCE IS ±50% OF FULL LOAD DATA. (heat rate based on treated water) 6) HEAT REJECTION TO LUBE OIL TOLERANCE IS ± 20% OF FULL LOAD DATA. (heat rate based on treated water) 7) HEAT REJECTION TO AFTERCOOLER TOLERANCE IS ± 5% OF FULL LOAD DATA. (heat rate based on treated water) 8) TOTAL AFTERCOOLER HEAT = AFTERCOOLER HEAT x ACHRF (heat rate based on treated water) 9) EMISSION DATA SHOWN ARE DRY AND NOMINAL VALUES. 10) TIMING BASED ON AFM INJECTORS. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: AS1359, CSA, IEC60034-1, ISO3046, ISO8528, NEMA MG 1-22, NEMA MG 1-33, UL508A, 72/23/EEC, 98/37/EC, 2004/108/EC Continuous The continuous power rating is applicable for supplying power indefinitely with no reduction in load. A Continuous power installation shuts down only for routine maintenance and scheduled overhauls. Average Power Output: 70-100%/ Continuous power rating Load: Non-Varying. Typical Hours/Year: Unlimited Typical Peak Demand: 100% of Continuous rated ekw for 100% of the operating hours. Ratings are based on SAE J1349 standard conditions. These ratings also apply at ISO3046 standard conditions Fuel Rates are based on fuel oil of 35º API [16º C (60º F)] gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional ratings may be available for specific customer requirements, contact your Caterpillar representative for details. For information regarding Low Sulfur fuel and Biodiesel capability, please consult your Cat dealer. 5

DIMENSIONS Package Dimensions Length 10261.7 mm 404.00 in Width 2530.3.1 mm 99.62 in Height 3977.7 mm 156.60 in Weight 51,230 kg 112,690 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #2354250). Performance No.: DM5406 06 Feature Code: 616DE04 Sourced: U.S. Sourced (03-12) www.cat-electricpower.com 2012 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. 6