DIN Rail Mounting Bracket

Similar documents
Wide-Vue Analog Panel Meters

ANSI Switchboard Meters

AC Wattmeters and VArmeters

Wide-Vue Analog Panel Meters

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

PLATINUM SERIES SWITCHBOARD METERS

Century Style Analog Panel Meters

( )

(770)

Temperature Sensing MI Cable Thermocouple Assemblies. Series TCM Multipoint Thermocouple Assemblies. View Product

Tel: &

Thermocouples W A T L O W

Covers for Cast Iron or Aluminum Device Boxes

DIN Panel Meters Long Scale

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

Price List Effective from :

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Submersible Averaging Duct Transmitters BA/T#SA Temperature Transmitter Installation & Operations

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

Distinctive Characteristics

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

Phoenix Thermal Supply

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.

Phoenix Thermal Supply

Type IMC Indoor current transformer

Hotset High-Watt Density Cartridge Heaters

International Instruments Edgewise Panel Meters

YCCS Zone/Bypass Damper Assembly

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Electronic Temperature Sensor

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Climate Control Products

Duct Averaging Transmitters BA/T#-A Temperature Transmitter Installation & Operations

Standard Program Technical Description

MODEL 422 Submersible Pump Controller

Basic Series Accessories Low Voltage Current Transformer Class 1

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

YCCS Zone/Bypass Damper Assembly

RAPID SHIP SENSORS, STOCK WIRE

CCS Zone/Bypass Damper Assembly

Transformer Disconnects

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Distinctive Characteristics

MS Application. Features. Proportional Valve Actuator General Instructions

MGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.

Distinctive Characteristics

Series A DC Link Chokes

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Instrument Enclosure Assemblies

Reliable liquid or simulated winding indication at eye level

Section 3 Index Furnace Tube Skin Thermocouples

2 SLR Series Line Reactors... 50

Sensors and Accessories

General Specifications

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

B BASIC HEAT TREATMENT CONSOLE

UNIVERSAL CALIBRATOR M

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Cartridge Heaters CARTRIDGE

Standard Product. Polyester powder paint; RAL 7035 textured light gray standard Custom colors available

HPC40 Series Calibrator psi

Direct Automation Trade Price List Process Controls Sensors 1

Weather Protective Devices

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

ICA Manufacturing Catalog. Your One Stop Metal Shop. Table of Contents. Visit us at:

Technical Data Sheet Sigma Series DS Meter

GM Series Direct Coupled Actuator

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

Fuseholders PAGE. Fuseholders.

TYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View

ROTARY Point Level Measurement for Inventory Control

LED Digital Analog Combination

Mark 37/377 Series. Control Valves Mark 37/377 Final Control Element. Final Control Element. Features

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

North American Automatic Manual Reset and Motorized Valves

AT30 SERIES BATTERY CHARGER

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

Strip Heaters Mica Insulated

INSTALLATION & OPERATION MANUAL

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

SINGLE DUCT TERMINAL UNITS

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

FREE-STANDING ENCLOSURE ACCESSORIES FREE-STANDING ENCLOSURE ACCESSORIES. Swing-Out Panels. Panels (Full & Half Length) For Single-Door Enclosures

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

Transcription:

DIN Rail Mounting Bracket Fits Simpson Hawk 3, Falcon and Counters Fits Standard Din Rail C 1 4.30 2.55 3.85 Din Rail Adapter 44 Enclosure: Attachment Clips: Stiffeners: Installed depth: UL94V-0 Rated ABS Spring Steel Steel 4.20 from top of DIN Rail to front of meter bezel

Thermocouples/RTD Quick Disconnect Assemblies Insulated Soft Wire Soft-wire thermocouples are available in two insulation types. All soft-wire selections have beaded butt welded measurement junctions. Temperature Rating Physical Properties Type J K ANSI Color Code Black Yellow Max. Operating Temperature 1 F 1600 F Note: All selections include standard plug and jack connectors. Catalog Number 21238 21239 Type Glass Braid Teflon Continuous 900 F (482 C) 400 F (204 C) Single Reading 1000 F (538 C) F (260 C) Abrasion Resistance Fair Excellent Moisture Resistance Good Excellent Chemical Resistance Good Excellent 316 Stainless Steel Best corrosion resistance of the stainless steel grades. Good corrosion resistance in H2S. Subject to damaging carbide precipitation. 900-1600 F (482-871 C) range. Cat. No. Description Ungrounded Junction This type of thermocouple junction is fully insulated from the welded sheath end. The ungrounded junction is excellent for applications where stray EMFs would affect the reading and for frequent or rapid temperature cycling. Response time is 2.5 seconds. THJ105 THJ1015 THK105 T/C J, 24 Gauge, Fiber Glass Braid, 5 foot T/C J, 24 Gauge, Fiber Glass Braid, 15 foot T/C K, 24 Gauge, Fiber Glass Braid, 5 foot Forming The XACTPAK sheath can be formed around a mandrel twice the sheath diameter. THK1015 THJ035 T/C K, 24 Gauge, Fiber Glass Braid, 15 foot T/C J, 20 Gauge, FEP Teflon, 5 foot THJ315 T/C J, 20 Gauge, FEP Teflon, 15 foot Metal Transition Assemblies Compression Fitting This adjustable fitting can be applied at any point along the sheath. It is used to mount a thermocouple assembly at a given depth, or to mount a thermocouple head on an assembly. Type J K RTD ANSI Color Code Black Yellow White Max. Operating Temperature 1 F 1600 F 1200 F Catalog Number 21242 21243 21244 Single Threaded Catalog# Length Sheath O.D. Inches Bore ±0.001 Inches Male NPT Inches Hex Across Flats Inches 21253 1-1/4 3/16 0.194 1/8 1/2

External Portable and Switchboard Shunts Dimension Table for External Portable Shunts 50mV Shunts Portable 150 amp Catalog No. 06714 Switchboard 100 amp Catalog No. 06 Amps A B C 1 1-1/16 1/4 1/4-20 5 1-1/16 1/4 1/4-20 10 1-1/16 1/4 1/4-20 15 1-1/16 1/4 1/4-20 25 1-1/16 1/4 1/4-20 Amps A B C 30 1-1/16 1/4 1/4-20 50 1-5/16 1/2 3/8-16 75 1-5/16 1/2 3/8-16 100 1-5/16 1/2 3/8-16 150 1-5/16 1/2 3/8-16 200 1-5/16 1/2 3/8-16 Dimension Table for Switchboard Shunts Amps A B C D E 100 4-1/2 1 3-1/2 1/2 3/8-16x1-1/2 150 4-1/2 1 3-1/2 1/2 3/8-16x1-1/2 200 4-1/2 1 3-1/2 1/2 3/8-16x1-1/2 300 5-1/2 1-1/2 4 1 1/2-13x2 400 5-1/2 1-1/2 4 1 1/2-13x2 5-1/2 1-1/2 4 1 1/2-13x2 Portable 50mV Shunts Switchboard 50mV Shunts Switchboard Shunts Range Cat. Number Range Cat. Number 1 06700 100 06 5 06703 150 06503 10 06704 200 06504 250 06505 15 06705 300 06506 25 06707 400 06507 30 06708 06508 50 06709 75 06711 5 leads included 100 06713 150 06714 Portable 100mV Shunts 200 06715 Amps Cat. Number E A C B D 5 leads included 10 06716 100 06717 5 leads not included External Portable Shunts C 1.25" 5.25" 6" B 5.6mm AB

Current Transformers Model 186 Current Transformer Current Transformers with Terminals Reduces high AC current signal to 5 amp AC signal Optimal for remote sensing of AC current signals Converts AC current signal to 0-10 ACV signal For use with rectifier type analog panel meters or digital indicators Perfect for low current measurement where a donut current transformer would not sense a signal Use with analog and 5 amp AC digital indicators Accuracy Frequency Insulation Class Weight ±2.0% (100 Amp) ±1.0% (100-1000 Amp) 50-400 Hz 0.6kV BIL 10kV full wave 1.0lb (453.59g) Range 0-100mA 0-mA 0-5Amp 0-10Amp 0-15Amp 0-20Amp 0-25Amp 0-30Amp 0-40Amp 0-50Amp VA 0.50 0.53 0.40 1.45 1.05 1.04 1.50 1.10 1.09 1.90 Cat. Number 01295 01304 01312 01314 01315 01316 01317 01318 01319 01321 3.53 3.00 1.56 DIA 0.44 3.78 1.83 1.77 0.21 X 0.31 2.75 1.09 2.15 2.43 1.75 2.00 1.38 1.40 1.75.69 2.43.94.75 1.12 2.375 2.81 Burden Range VA@60Hz Catalog Number 100:5 2.0 37020 150:5 5.0 37021 200:5 5.0 37022 300:5 12.5 37023 :5 20.0 37024 1000:5 25.0 37025

Donut Current Transformers Ampere Turns Catalog Primary Secondary Ratio Number A B C 50 5 10:1 01293 75 5 15:1 01306 3.56 1.56 1.10 100 5 20:1 01297 150 5 30:1 01298 200 5 40:1 01299 250 5 50:1 01313 300 5 60:1 01300 3.56 2.06 1.10 400 5 80:1 01305 5 100:1 01301 600 5 120:1 02303 750 5 150:1 02459 1000 5 200:1 02304 4.50 3.00 1.09 Meets A.S.A C57.13 Standard Flexible leads are UL105, 105 C CSA approved Molded from impact and abrasive resistance black nylon for rugged construction ±2% Accuracy Accuracy For Catalog Number Turns Ratio 2 VA Burden 01293 10:1 2% 01306 15:1 2% 01297 20:1 1% 01298 30:1 1% 01299 40:1 1% 01313 50:1.8% 01300 60:1.6% 01305 80:1.5% 01301 100:1.5% 02303 120:1.5% 02459 150:1.3% 02304 200:1.3%

Donut Current Transformer Wrapping Information Formula: Primary Turn Ratio Modification Ka = Kn x Nn / Na Primary Turn Ratio Modification Formula: lp Ns ls Np Where: Ka = Actual Transformer Ratio Kn = Nameplate Transformer Ratio Na = Actual Number of Primary Turns Nn = Nameplate Number of Primary Turns Where: lp - Primary Current ls - Secondary Current Np - Number of Primary Turns Ns - Number of Secondary Turns The ratio of the current transformer can be modified by adding more primary turns to the transformer. By adding primary turns, the current required to maintain five amps on the secondary is reduced. Example: 1 Primary Turn Nameplate Actual Ratio Ratio 100:5 100:5 A 100:5 current transformer designed for one primary turn. Example: A 300:5 Current Transformer. 300p 60s 5s 1p (In practicality one turn is dropped from the secondary as a ratio correction factor.) The ratio of the current transformer can be modified by altering the number of secondary turns by forward or backwinding the secondary lead through the window of the current transformer. By adding secondary turns, the same primary current will result in a decrease in secondary output. By subtracting turns, the same primary current will result in greater secondary output. Again using the 300:5 example adding five secondary turns will require 325 amps on the primary to maintain the 5 amp secondary output or 325p 65s 5s 1p Deducting 5 secondary turns will only require 275 amps on the primary to maintain the 5 amp secondary output or 325p 65s 5s 1p 2 Primary Turns Nameplate Actual Ratio Ratio 100:5 50:5 The above ratio modifications are achieved in the following manner: 4 Primary Turns Nameplate Actual Ratio Ratio 100:5 25:5

Model 183 Multiplier Current Transducers Reduces AC current signals down to 4-20 DCmA Screw terminals for easy connection Operates on 24V DC power Reduces high AC Voltage Signals down to 150 VAC Reduces high DC Voltage signals down to µadc Accuracy ±1% Accuracy: Frequency: Insulation Class: Max. Output: Temp. Effect: Accuracy: Operating: Storage: Supply Voltage: Weight: ±0.5% F.S. Max 60Hz 600V 30DCmA ±0.04%/ C -30 C to +65 C -55 C to +85 C 24 DCV ±10% 1.5lb (680.39kg) DC Volts - 2000 Ohms/Volt Used only with Simpson DC Volt analog panel meters or with 0-2 ma DC digital panel meters. Digital units will need to be recalibrated when a multiplier is used. Range 0-0-1000 0-2000 0-4000 0-0 Multiplier Resistance M 1 2 4 8 10 Meter Sensitivity DC µa Catalog Number 08552 08554 08557 08560 08561 0.25 X 0.31 1.40 2.00 2.36 1.69 4.12 0.44 X 0.50 4.68 AC Volts - 166 Ohms/Volt Used only with Simpson AC Volt, iron vane analog panel meters or with a 0-200 VAC digital meter using an external 25 /1W resistor across the inputs. 2.69 2.14 3.50 0.22 X 0.50 Range 0-0-600 0-750 0-1000 Impedance @ 60 Hz 58,333 75,000 100,000 141,666 3.59 2.75 Voltage Reduced 350 450 600 850 Voltage Drop 150 150 150 150 Catalog Number 08562 08563 08564 08565 0.93 DIA 1.41 2.75 0.15 1.25 DIA 0.75 4.50 2.25 0.44 4.88 3.50 4.00.016.42 2.75 3.38 Input Current Output Current Range(ACA) Range(DCmA) Catalog Number 0-5 A 4-20mA 37000 0-50 A 4-20mA 37001 0-75 A 4-20mA 37002 0-100 A 4-20mA 37003 0-150 A 4-20mA 37004 0-200 A 4-20mA 37005 0-300 A 4-20mA 37006

1/8 DIN NEMA 4 Removable Cover Bezel Kits Protects 1/8 DIN indicators and controllers Dust tight and water tight to NEMA 4 standards Removable front cover allows access to programming buttons or scaling potentiometers This bezel kit provides an attractive appearance for Wide-Vue analog panel meters. Die cast with a black satin finish, bezel kits are designed for behind panel mounting and can accommodate a panel thickness from 1/8 to 3/16. All required mounting hardware is included. Panel Cutout Catalog Size A B Number 3-1/2 3.406 2.094 01253 4-1/2 4.812 2.750 01123 Panel Cutout A B 3/16 to 1/4" Diameter hole for zero adjust access (optional). Wide-Vue or Tru-Vue Bezel Kit Lens Material Gasket Material Bezel Material Bezel Finish Bezel Overall Panel Cutout Clear 94-V-0 UL-rated polycarbonate with UV inhibitor Closed Cell Neoprene Steel Black Polyurethane 4.3 x 2.41 x 0.28 (109.2mm x 61.2mm x 7.1mm) 4.3 x 2.41 x 0.96 (109.2mm x 61.2mm x 24.4mm) 3.66 x 1.79 (93mm x 45.5mm) Bezel kit for 2-1/2 Wide-Vue or Tru-Vue meter 01255 Catalog number 43