Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Emergency Luminaire with LED Series EXLUX 6409/1

LED Linear Luminaire Series EXLUX 6402

Linear luminaire with LED Series EXLUX 6002

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Sheet-Steel Light Fittings Series 6014 / 6414

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Compact Sheet-Steel Light Fittings Series 6114/1

Linear Luminaire for Fluorescent Lamps

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Plug and Socket Devices SolConeX 16 A Series 8570

Compact Sheet-Steel Light Fittings Series 6114

Floodlight LED Series 6125

Floodlight LED Series 6525

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Floodlight Series 6121

Floodlight LED Series 6525

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Sheet Steel Emergency Light Fitting Series 6018

Terminal Boxes Series 8125

Floodlight Series 6521/4

Load disconnect switch Series 8146/5-V11

Control Buttons / Switches for Panel Mounting Series 8003

7 Lighting Technology

Linear Luminaire with LED

Ex UPS standard Series 8265

7 Lighting Technology

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Tubular Light Fitting with LED Series 6036

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Position Switches Series 8074/2

Position Switches Series 8060/2

Position Switches Series 8070/2

Tank Inspection Lights Series 6122

Safety Switches Series 8537

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Control switch/load disconnect switch Series 8008

7 Lighting Technology

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Operating Instructions

Control Buttons Series 8082

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Linear fluorescent luminaire LED V-CG-S

7 Lighting Technology

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Pendant Light Fitting IEC

Battery Boxes Series 8316

Load and Motor Switches, Load-Break Switches Series 8549

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Operating Instructions

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Metal Position Switch Series 8074

EXEL-L. Detail of the internal side. Transparent polycarbonate

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Load and Motor Switches, Load-Break Switches Series 8544

Linear fittings EVDL LED fitting - zones 21, & 22

FHL. Ex d. Body in aluminium

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

EX-REPAIR AND MAINTENANCE RECEPTACLES

Load and Motor Switches, Load-Break Switches Series 8544

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

10 Load and Motor Switchgear

K: bracket type. L: pole type

HTSB system System overview

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

Linear fittings EVNL LED fitting - zones 2, & 22

Control Device System NEC Series ConSig 8040

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

EWE. Ex de. Cooling fins

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Transcription:

> As wall, ceiling and pendant light fitting or side entry lamp > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened www.stahl.de 15454E00 The lights of the can be used for normal lighting but also for an emergency light which is supplied with current via a group or a central system. ATEX / IECEx Zone 0 1 2 20 21 22 For use in x x x x Explosion Protection Global (IECEx) Gas and dust IECEx PTB 13.0003 Ex db eb IIC T4 Gb Ex tb IIIC T80 C Db Europe (ATEX) Gas and dust PTB 13 ATEX 2004 E II 2 G Ex db eb IIC T4 Gb Certifications and certificates Certificates E II 2 D Ex tb IIIC T80 C Db IECEx, ATEX, Brazil (INMETRO), Kazakhstan (TR), Russia (TR), Serbia (SRPS), Belarus (TR) WebCode 6001A Lighting /1

Selection Table Version Through wiring Length Lamp wattage Number of lamps Order number mm W kg EXLUX 6001 5-way 700 18 2 6001/522-9510-15-131 4.500 Order Number Supplement Weight 1310 36 2 6001/542-9510-15-131 6.750 1610 58 2 6001/562-9510-15-131 7.900 without 700 18 2 6001/522-9010-15-131 4.350 1310 36 2 6001/542-9010-15-131 6.540 1610 58 2 6001/562-9010-15-131 8.300 Through wiring without 6001/5..-.0..-..-... with 5 conductors 6006/5..-.5..-..-... ECG 220... 240 V 2-lamps AC, 1-lamp DC 6001/5..-...0-..-... 220... 240 V 2-lamps AC, 2-lamps DC 6001/5..-...1-..-... 110... 240 V 2-lamps AC, 1-lamp DC (18 W and 36 W only) 6001/5..-...2-..-... 110... 240 V 2-lamps AC, 2-lamps DC (18 W and 36 W only) 6001/5..-...3-..-... Connection terminal Spring clamp terminal type WAGO 0.5... 4 mm 2 6001/5..-...-1.-... Screw-type terminal type STAHL 1.5... 6 mm 2 6001/5..-...-2.-... Cable glands Standard 3 x holes M25 6001/5..-...-..-131 2 x M25 x 1,5 cable gland and 2 x M25 x 1,5 stopping plug Special 3 x holes M20 2 x M20 x 1,5 cable gland and 2 x M20 x 1,5 stopping plug 6001/5..-...-..-232 Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! /2 Lighting

Technical Data Electrical data Control gear 6001/...-...0-..-... 6001/...-...1-..-... Lamp start Cold start Cold start Voltage 220... 240 V AC 220... 240 V AC Voltage DC during switching 198 264 V DC 104 264 V DC on Voltage DC during operation 176 264 V DC 198 264 V DC Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC 1 lamp 2 lamps Lamp standard IEC 60081 IEC 60081 Lamp power 18, 36, 58 W 18, 36, 58 W Nominal current 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 6001/...-...2-..-... 6001/...-...3-..-... Lamp start Cold start Cold start Voltage 110... 240 V AC 110... 240 V AC Voltage DC during switching on 104 264 V DC 104 264 V DC Voltage DC during operation 104 264 V DC 104 264 V DC Frequency 0 / 50 60 Hz 0 / 50 60 Hz Operation of the lamps DC 1 lamp 2 lamps Power factor cos p cos p ) 0.97 capacitive; no additional compensation required Disconnection of the light When opening the light Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are NC contacts, they can only be switched on again when the lamp cover and the central locking system are closed. In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. End of life switch The electronic ballast, type 6042/9..-. fulfills the requirements according to IEC 61347-2-3 (simulation of the "end of life effect" of fluorescent lamps, "asymmetric pulse test 1" and "asymmetric power test 2" correspond to the test conditions in the draft IEC 60079-7 ed.4 appendix H). Luminous characteristics Measures for light guidance Lamp standard IEC 60081 IEC 60081 Lamp power 18, 36 W 18, 36 W Nominal current 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma Standard: Deep bowl, reflector of the lamp is white Lateral dazzle limitation in the lamp cover Lighting /3

Technical Data Ambient conditions Operating temperature range Through wiring Type without with 6001/52.- 0-..-... -30... +60 C -30... +50 C 6001/52.- 1-..-... -30... +60 C -30... +50 C 6001/52.-...2-..-... -30... +45 C -30... +40 C 6001/52.- 3-..-... -30... +45 C -30... +40 C 6001/54.- 0-..-... -30... +55 C -30... +50 C 6001/54.- 1-..-... -30... +55 C -30... +50 C 6001/54.- 2-..-... -30... +45 C -30... +40 C 6001/54.- 3-..-... -30... +45 C -30... +40 C 6001/56.- 0-..-... -20... +55 C -20... +50 C 6001/56.- 1-..-... -20... +55 C -20... +50 C The lowest ambient temperature when used with breather is -20 C. Mechanical data Degree of protection IP66 (IEC 60598) IP66 / IP67 (IEC 60598) 18 W und 36 W Protection class I (with internal PE connection) Impact strength (IK code) IK10 (IEC 62262) Material Enclosure Enclosure Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Translucent cover Polycarbonate Seal Silicone foam gasket in the lamp cover Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Connection Through wiring Plastic: Metal: Special: Standard: Special: Through wiring without 2 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Spring clamp terminals 5-pole: L1, L2, L3, N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) 4 mm 2 finely stranded without core end sleeve only (2 free clamping units for each pole available) Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2 x 1.5... 6 mm 2 (solid); 2 x 1.5... 4 mm 2 (finely and extra finely stranded) Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected on the opposite sides. Terminals: see Techn. data Wiring cross-section: 2.5 mm 2 for max. 16 A Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). /4 Lighting

Technical Data Assembly Light distribution curves For outdoor mounting, a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 18 W: 320... 480 mm; 36 W / 58 W: 670... 930 mm) 180 200 180 160 160 120 80 120 80 45 30 15 0 15 30 45 45 30 15 0 15 30 45 cd/klm 83% C0 - C180 C90 - C270 16697E00 cd/klm 77% C0 - C180 C90 - C270 16698E00 2x 18 W 2x 36 W 180 160 120 80 45 30 15 0 15 30 45 cd/klm 75% C0 - C180 C90 - C270 16699E00 Lighting /5

Light distribution curves 2x 58 W Accessories and Spare Parts Designation Figure Description Art. no. Weight Fluorescent lamps 04936E00 Two-pin cap d 26 mm Light colour: universal white Pins made of brass 18 W 1350 Im kg 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Lamp cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 for luminaire L=1610 222429 1.450 for luminaire L=700 (resistant to aromatic substances) 256534 0.639 for luminaire L=1310 (resistant to aromatic substances) 256535 1.149 for luminaire L=1610 (resistant to aromatic substances) 256536 1.450 Lamp-holder Lamp holder G13 1 piece 117252 0.036 Switch 05696E00 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.026 10809E00 Socket key M8 / wrench size 13; to open/close the central locking 222430 0.210 15507E00 Mounting rail for a variable mounting distance 1 pair 222826 0.350 15584E00 Mounting bracket mounting clamp mounted on a mounting rail for a variable mounting distance 1 pair 222456 0.400 15585E00 Pole mounting sleeve for the subsequent mounting on lights 18 W and 36 W, completely with assembly parts 227512 3.200 16985E00 Ceiling and wallmounting bracket mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 15586E00 1 pair 222827 1.200 /6 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight Pipe clamp with mounting rail for a variable mounting distance; Material: stainless steel 1 pair kg 15583E00 R 1 1 / 4 222458 0.900 R 1 1 / 2 222459 1.200 R 2 222460 0.750 Bracket for wall mounting with tube for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Ring bolt 05378E00 M8, direct mounting in insert nuts, 1 pair 115736 0.112 Breathing gland M25 x 1.5 in order to avoid condensate formation for 6009/1 115738 0.017 Ballast 05703E00 Spare ballast for replacement 1:1 6042/243-21; 18 and 36 W; 220... 240 V; 1xDC 258168 1.300 15587E00 6042/243-22; 18 and 36 W; 220... 240 V; 2xDC 258169 1.300 6042/963-21; 58 W; 220... 240 V; 1xDC 117597 1.388 6042/963-22; 58 W; 220... 240 V; 2xDC 117598 1.400 6042/913-22; 18 W; 110... 240 V; 2xDC 202164 1.550 6042/983-22; 36 W; 110... 240 V; 2xDC 202165 1.550 Spare ballast for replacement of: 6042/923-21; 18 W; 220... 240 V; 1xDC 257901 1.400 15587E00 6042/923-22; 18 W; 220... 240 V; 2xDC 257902 1.400 6042/943-21; 36 W; 220... 240 V; 1xDC 257903 1.400 6042/943-22; 36 W; 220... 240 V; 2xDC 257904 1.400 Maßzeichnungen (alle Maße in mm [Zoll]) - Änderungen vorbehalten 15440E00 Maße Leuchte 17/18 W 32/36 W 40/58 W L1 700 [27,56] 1310 [51,57] 1610 [63,39] L2 1) 400 [15,75] 800 [31,50] 800 [31,50] L3 2) 320... 480 [12,60... 18,90] 670... 930 [26,38... 36,61] 670... 930 [26,38... 36,61] b 184 [7,24] 184 [7,24] 184 [7,24] h1 125 [4,92] 125 [4,92] 125 [4,92] 1) fester Montageabstand 2) variabler Montageabstand Lighting /7

Maßzeichnungen (alle Maße in mm [Zoll]) - Änderungen vorbehalten EXLUX 6001 Standardleuchte Ø 42 ± 0,60 [ 1,65 ] Ø ± 0,02 17755E00 Maße Leuchte 17 / 18 W 32 / 36 W L1 978 [38,50] 1587 [62,48] L2 390 [15,35] 338 [13,31] EXLUX 6001 mit Mastschuh Dimensional drawings for assembly parts and accessories (all dimensions in mm [inches]) Subject to alterations 12 [ 0, 47 ] 18,50 [ 0, 73 ] 30 30,50 [ 1, 20 ] 215 [ 8.46] [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] 13 [0,51] 15779E00 ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] Mounting rail 15778E00 15782E00 15781E00 15783E00 Ring bolt fitted in insert nut of the luminaire Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail /8 Lighting

Dimensional drawings for assembly parts and accessories (all dimensions in mm [inches]) Subject to alterations 186 [7,32] 146 [5,75] 200 [7,87] 80 [3,15] 15780E00 03257E00 Wall mounting bracket fitted in mounting rail Bracket for wall mounting with pipe section We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Lighting /9