Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

Similar documents
Bianco RainsaverMK4E Installation and Operating Instructions

INSTRS30709 rev 1 02/10/09 Page 1

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

Bianco Rainsaver MK3 Installation and Operating Instructions. The no brainer. Bianco Rainsaver MK3 & MK3E Installation and Operating Instructions

OPERATION MANUAL SUBMERSIBLE FOUNTAIN PUMP PM2 600LV PM2 900LV PM2 1500LV PM2 2400LV PM2 4500LV

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual

Petrol Engine Powered Pump Instruction Manual

Rainsaver MK4E RAINWATER HARVESTING SYSTEMS

Rainsaver MK3E RAINWATER HARVESTING SYSTEMS

Rainsaver MK6 LEADERS IN QUALITY RAIN SAVING SYSTEMS

Domestic Water Supply Pressure Pumps

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

INSTALLATION AND OPERATING INSTRUCTIONS

GWA BATHROOMS & KITCHENS WARRANTY PERIODS

INSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet

PRODUCT RANGE NEW PUMP PERFORMANCE

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

Issue 3. Description: ROBINHOOD TAP PULL-OUT SERIES Model Numbers: TPO1200. Model may vary slightly from image pictured

Installation and Operating Instructions for

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

INSTALLATION AND OPERATING INSTRUCTIONS

ROCA KHROMA TOILET SUITE

PRODUCT MANUAL. Backpack Sprayer 12L

SWIMMING POOL CARTRIDGE FILTER INSTALLATION AND OPERATING INSTRUCTIONS

ROCA THE GAP BACK TO WALL TOILET SUITE

AL-KO OFF-ROAD PIN COUPLING USERS MANUAL

Installation and Operating Instructions for Davey XP/T & XJ/T Pressure Systems with

PRODUCT MANUAL. Heavy Duty Backpack Sprayer 16L

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

INSTALLATION AND OPERATING INSTRUCTIONS

Owner s Manual. H03548 Rev A

Installation and Operating Instructions

Davey Repair or Replacement Guarantee

Installation and Operating Instructions for Davey HP/T & HS/T Pressure Systems with

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

K877. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 1 x 1 x 1. x 2 x 2 x 1 x 1. x 1 x 1. Revision No: 3C 1

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

ROCA DUO PLUS OVAL INSET BATH

Inst all a ti o n and Oper a tin g Instru c ti o n s

CONTENTS. Calibration Self Check & Technical Specifications 13 Care & Maintenance, Trouble Shooting 15 Warranty 16

INSTALLATION AND OPERATING INSTRUCTIONS

RECOMMENDATIONS Turbosmart recommends that your Blow off valve (BOV) is fitted by an appropriately qualified technician

AL-KO ESC USER MANUAL

K682. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 8. x 4 x 2 x 2 x 4. x 4 x 4 x 4. Revision No: 1A 1

Handling Belts. ARTG No: LM53072 LM53073

K683. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 8 x 2. x 2 x 4 x 4 x 4. x 4. Revision No: 3C 1

WETech Active Trimmer

K681. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 2 x 2 x 2. x 2. Revision No: 4D 1

HANDS FREE FOOT & KNEE OPERATED TAPWARE

HM Series Electric Pumps

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

K708. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 4 x 4. x 4. Revision No: 1A 1

PRODUCT MANUAL. Heavy Duty Shoulder Sprayer 5L & 8L

K381W. Fitting Kit. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 2. x 4. Revision No: 4C 1

SIGMA PNEUMATIC CARE BUTTON

K131. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 2. x 2 x 4. Revision No: 2C 1

VERSION 2017 V.1.0

K1013 K1013. Fitting Instructions for Basic Carrier. x 4 x 4 x 1 x 8. x 4 x 1 x 4 x 1. x 4 x 1 x 1 x 2. Revision No: 1A 1

OWNER S OPERATING MANUAL

MIZU QUICK CHANGE DUAL FILTER SYSTEM

K163. Fitting Kit. Fitting Instructions for Basic Carrier. x 4. Revision No: 2C 1

VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

GBC Polar A4 & A3 Laminators. Instruction Manual

OWNER S OPERATING MANUAL

ALAPE METAPHOR UNDERCOUNTER BASIN

Ford Warranties THE FORD EXPRESS NEW VEHICLE WARRANTY - WARRANTY STATEMENT 1

GLOSS WALL BATH SET PRODUCT CODE: FINISH: GS783 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

TRIMLINE CARTRIDGE FILTERS

PLEASE READ. Easy Installation

RUSH SHOWER/BATH DIVERTER MIXER PRODUCT CODE: FINISH: RU791 CHR CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH

Instruction Booklet. P.O. Box Berkeley Rd UNANDERRA,NSW 2526 Australia Tel:

K309. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 2 x 2 x 4. x 1 x 2 x 1. Revision No: 7C 1

SILVAN AUSTRALIA PTY. LTD.

OWNER S OPERATING MANUAL

DOMINIQUE MKII wall hung vanity 900mm. Wall Hung Vanity 900mm (Left Hand Bowl) Cabinet Only - Front View Cabint Only - Side View

DOMINIQUE MKII SEMI RECESSED vanity

Euro Lightweight Wheeled Walker

K440. Fitting Kit. Fitting Instructions for Basic Carrier. x 4 x 4 x 4 x 4. x 1 x 1 x 4 x 1. Revision No: 10J 1

RUSH WALL TOP ASSEMBLIES EXT D 15MM PRODUCT CODE: FINISH: RU067 MB MATTE BLACK 3/4 TURN OPERATION PREMIUM FINISHES

EcoPure. monarchseries.com.au. Cartridge Filter. INSTALLATION & OPERATING INSTRUCTIONS 50sqft 75sqft 100sqft 150sqft

INSTALLATION AND OPERATING INSTRUCTIONS

Q20. Track System. Fitting Instructions for Basic Carrier. x 2 x 2 x 2 x 1. x 1 x 1 x 4 x 4. Revision No: 1A 1

EXTRA WIDE STEEL ROLLATOR

K500. Fitting Kit. Fitting Instructions for Basic Carrier. x 1 x 4 x 4 x 4. Revision No: 14N 1

INSTALLATION INSTRUCTIONS INSTALLATION OPERATION TROUBLE SHOOTING

AXA Cento semi wall basins with shelves

USER MANUAL MB002. nasal aspirator kit

TRIMLINE CARTRIDGE FILTERS

ROUND REMOTE BUTTONS AND PLATE (IN-WALL)

AL-KO OFF-ROAD BALL COUPLING USERS MANUAL

3.0 INSTALLATION INSTRUCTIONS. Avon 21 Self-closing taps (Push button) B0992AA Self-closing basin pillar tap

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

General Warranty Terms and Conditions

Transcription:

Bianco RainsaverMK6 Installation and Operating Instructions Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water. INSTRS6 rev 0 01/09/16 Page 1

1. Introduction: Bianco Rainsaver MK6 Installation and Operating Instructions The Bianco Rainsaver MK6 is an Automatic Rainwater / Mains Water Changeover Device designed to provide automatic mains back up for Pressure Pump supply systems. The Bianco Rainsaver MK6 is designed to be installed in conjunction with a DAB, BIANCO or UNIVERSAL surface mounted or submersible Pressure Pump supply system that is fitted with an independent PRESSURE AND FLOW CONTROLLER with LOSS OF PRIME PROTECTION and AUTOMATIC RE-START that is set at 2.2 bar start pressure. WARNING! The Bianco Rainsaver MK6 is NOT A PUMP CONTROLLER! 2. General Specifications: Maximum water temperature (mains + pump): 40 0 C. Maximum recommended continuous pump flow: 120 litres per minute. Maximum recommended pump pressure: 1000 kpa. Maximum recommended mains inlet pressure: 1000 kpa. 3. Operation: The Bianco Rainsaver MK6 supplies clean rainwater from a rainwater tank and associated pressure pump system, to toilets, laundry, garden taps and household. Mains water is also connected to the Bianco Rainsaver MK6 as an automatic back up. When the pressure pump ceases to supply water because it has detected that the rain water level in the tank is too low, or if there is a power or pump failure, the Bianco Rainsaver MK6 will automatically change over to supply mains water to meet the household needs. When the rainwater supply is replenished and auto restart has commenced, or the power is restored to the pump, the pump will pressurise the Bianco Rainsaver MK6 and the unit will switch back automatically to supplying tank water to the household. 4. Installation: 4.1 Rainsaver MK6 installation. The Bianco Rainsaver MK6 can be Wall mounted or Pump Mounted i.e. mounted directly onto a pressure pump outlet. 4.11 Wall Mounting: The Rainsaver MK6 can be remotely mounted any distance from the pump. The Rainsaver MK6 can be mounted outdoors. The Rainsaver MK6 can be mounted with the mains inlet pointing in either direction when supported by the pipework. INSTRS6 rev 0 01/09/16 Page 2

4.12 Pump Mounting: Rainsaver MK6 can be mounted directly onto the outlet of the pump controller. 4.2 Filtration and Water Quality The Bianco Rainsaver MK6 is designed to operate on clean rainwater and clean mains water supply, and as such, the rainwater tank should be fitted with an inlet strainer, preferably shaded type to reduce algae, and a suitable first flush device. White International strongly recommends the use of a strainer or filter upstream with easy access for period cleaning from both the rainwater and mains inlet connections of the Bianco Rainsaver MK6. Additional water filters may be required. Also check the water tank and first flush diverter as per manufacturers instructions regarding periodic servicing that is required. Filters need to be checked regularly as reduced flow caused by blocked filters can damage pumping equipment. 4.3 Plumbing Plumbing connections should be carried out by a licensed plumber. Use of flexible pipe connections and isolation vales is recommended to assist in alignment and servicing and to reduce any transmitted noise. All pipe-work and outlet fittings from the Bianco Rainsaver MK6 must be labelled to AS3500. The Bianco Rainsaver MK6 control incorporates a dual check valve to prevent cross connection between mains and rainwater. Connection to an underground rain water tank, or local water supply authorities, may require additional, or higher safety level, back flow prevention, and your licensed plumber can advise you on this. The incorporation of an additional Tee fitting between the tank water pressure pump supply, and the Bianco Rainsaver MK6 lower PUMP INLET, will allow the householder to use collected rainwater, but NOT mains water supply, to irrigate gardens and lawns, or wash cars. Cautions: In conjunction with this manual, read and understand the installation and maintenance manual for the water pump that is to be connected to the Bianco Rainsaver MK6. The Bianco Rainsaver MK6 and any pump connected to it are not to be used by children or infirm persons and must not be used as a toy. A licensed plumber should carry out plumbing connections. Servicing of the Bianco Rainsaver MK6 and, or water pump should only by carried out by qualified persons. INSTRS6 rev 0 01/09/16 Page 3

Do not clean the Bianco Rainsaver MK6 with abrasive or petroleum based fluids, and do not use hydrocarbon propelled sprays on or around the Bianco Rainsaver MK6. 5. Sound Emissions. The Bianco Rainsaver MK6 is virtually silent but may emit noises associated with the flow of water through the unit. In any case, the pump, which is connected to the Bianco Rainsaver MK6, may emit sound levels, which may inconvenience you or your neighbours, or may operate during normal sleeping hours, which may be prohibited by local government regulations. If this is the case, your pump can be switched off during the night or may be operated from a time clock. Your Bianco Rainsaver MK6 will automatically supply your house with Mains water supply while the pump is inactive. 6. Maintenance. Ensure that water flowing through the Rainsaver MK6 is as free from dirt and foreign matter as conditions allow. Ease of accessibility will aid any maintenance and reduce any servicing costs if required. Periodically inspect the rainwater tank inlet strainer and the first flush device. Periodically inspect filters downstream and strainers if fitted upstream from the Bianco Rainsaver MK6 every 6 months depending on water quality and usage. Operate the Rainsaver on mains regularly or at least once a month by turning the power off to the pump 7. Trouble shooting. Consult the manuals supplied with the water pump and its controller if fitted in addition to the following guide. 1. Mains flow is not available or low when Pump is switched off or not operating. a. Isolation valve, if fitted, is not open. b. Debris has blocked the inlet. c. External Inlet strainer / filter, if fitted, are blocked. 2. Pump flow is not available or low when pump is operating through Bianco Rainsaver MK6. a. Pump has lost its prime. b. Isolation valve, if fitted, is not open. c. External Inlet strainer / filter, if fitted, is blocked. 3. Pump does not start. a. Rainwater tank is empty. b. Power supply is off. c. Pump controller is not installed correctly or jammed with debris. d. Pump has a fault. 4. Pump does not stop. a. Leak in plumbing. b. Pump controller is not installed correctly or jammed with debris For after sales service please contact White International Customer Service: 1300 783 601. INSTRS6 rev 0 01/09/16 Page 4

8. Pumps Pumps and pump controllers must be accessible and fitted with barrel unions for service and maintenance. All surface mounted pumps must be protected from the elements with a suitable pump cover. Submersible pump accessories such as pump stands, high inlets, floating suction hose kits assist in the pumping cleaner water that is found at higher levels in the rainwater tank. 9. Water Tanks Water borne algae and roof litter can accumulate at the bottom of your rainwater tank that can be sucked up by your pump. To reduce filter blockages we recommend that suction outlets on rainwater tanks be 100 mm from the bottom of the tank, and submersible pumps elevated by 90 mm. 10. Installation Dimensions INSTRS6 rev 0 01/09/16 Page 5

Typical Installations. DAB, BIANCO or UNIVERSAL surface mounted pumps fitted with SK20 pump controller. RAINSAVERMK6 can be pump or pipe mounted. INSTRS6 rev 0 01/09/16 Page 6

Typical Installations. BIANCO B42A or JH8003P submersible pumps with remote SK13 pump controller. RAINSAVERMK6 can be pipe mounted. INSTRS6 rev 0 01/09/16 Page 7

Typical Installations. DAB DIVERTRON 1200 submersible pump with internal pump controller. RAINSAVERMK6 can be pipe mounted. INSTRS6 rev 0 01/09/16 Page 8

MK6 2 YEAR REPLACEMENT WARRANTY Terms & Conditions 1) White International Pty Ltd / White International NZ Ltd (White International) warrant that all products distributed are free from defects in workmanship and materials, for their provided warranty period as indicated on the top or opposite side of this document. Subject to the conditions of the warranty, White International will repair any defective products free of charge at the premises of our authorised service agents throughout Australia and New Zealand if a defect in the product appears during the warranty period. If you believe that you have purchased a defective product and wish to make a claim under this warranty, contact us on our Sales Hotline on 1300 783 601, or send your claim to our postal address or fax line below and we will advise you as to how next to proceed. You will be required to supply a copy of your proof of purchase to make a claim under this warranty. 2) This warranty excludes transportation costs to and from White International or its appointed service agents and excludes defects due to non-compliance with installation instructions, neglect or misuse, inadequate protection against the elements, low voltage or use or operation for purposes other than those for which they were designed. For further information regarding the suitability of your intended application contact us on our Sales Hotline on 1300 783 601. If you make an invalid claim under this warranty, the original product will be sent back to you unrepaired. 3) This warranty refers only to products sold after the 1st January 2012, and is not transferable to another product type and only applies to the original owner, purchaser or end user, and is in addition to the consumer guarantees found within the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 4) Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. 5) To the fullest extent permitted by law, White International excludes its liability for all other conditions or warranties which would or might otherwise be implied at law. To the fullest extent permitted by law, White International s liability under this warranty and any other conditions, guarantees or warranties at law that cannot be excluded, including those in the Competition and Consumer Act 2010 (Cth), is expressly limited to: (a) in the case of products, the replacement of the product or the supply of equivalent product, the payment of the cost of replacing the product or of acquiring an equivalent product or the repair of the product or payment of the cost of having the product repaired, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer Act 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand; and 6) To the fullest extent permitted by law, this warranty supersedes all other warranties attached to the product or its packaging. 7) In the case of services, supplying the services again or the payment of the cost of having the services supplied again, is at the discretion of White International or a 3rd party tribunal elected under the Competition and Consumer At 2010 (Cth) for goods purchased in Australia and the Consumer Guarantees Act 1993 (NZ) for goods purchased in New Zealand. 8) Our warranty commences from the date of purchase of the above mentioned pumps. Proof of purchase is required before consideration under warranty is given. Record your date of purchase in the space below and retain this copy for your records. Date of Purchase... Model Purchased... WHITE INTERNATIONAL PTY LTD ABN 48 000119380 52-60 Ashford Ave, MILPERRA NSW 2214 PO BOX 304, MILPERRA LPO NSW 2214 Ph: 02 9783 6000 Fax: 02 9783 6001 Customer Service Hotline: 1300 783 601 Customer Service Faxline: 02 9783 6003 EMAIL: Sales Enquiries: info@whiteint.com.au WHITE INTERNATIONAL NZ LTD 15G Kerwyn Ave, East Tamaki, AUCKLAND, NZ PO BOX 12-704, PENROSE, AUCKLAND Ph: 09 579 9777 Fax: 09 579 7775 Customer Service Hotline: 0800 509 506 Customer Service Faxline: 0800 804 344 EMAIL: General Info Enquiries: sales@whiteint.co.nz INSTRS6 rev 0 01/09/16 Page 9