Automatic sliding doors DCU1 DCU1-2M. EN Wiring diagram

Similar documents
Assembly and Operating Instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Automatic Swing Door Operator DFA 127 IN (Inverse) Operating instructions E

Operating Instructions Type MPT 53

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Sliding door operator

Automatic concealed bollards 275 H600 and 275 H800 Control station

Table of contents. Foreword: GEZE sliding door systems 4 Overview table 5

Operating Instructions (Translation)

Important instructions

ES 200 STANDARD ES 200 EASY PLUS

Senior Swing Control Box. Table of Contents

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

M-Series 415 & in 1 Elevator Light Curtain. Installation Manual

OPERATING INSTRUCTIONS

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

ZB0050 / ZB0051 ZB0070 / ZB0071

Gate & Door Controller with LCD and Intelligent Technology

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

Operating Instructions for Control CS 300

Installation manual wall-mounted distributor

KAVİ ELEKTROMEKANİK İNŞ.MÜH.SAN.TİC.LTD. ŞTİ www. kavi-ltd.com Mail : ES 200 EASY. Sliding door operator

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SST FLEX. Automatic break-out sliding doors for emergency exits and escape routes with powerful ES operators

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Technical Documentation

zelsius Installation and operating manual All that counts EnergyMetering

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Original Operating Manual

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

Porte 150 Users Manual Swing Gate Opener 24V DC

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Installation manual portable distributors

User Manual Rittal PMC UPS 6kVA

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

ECONOMISER SERIES E2T USER MANUAL

Installation instructions BasicRelay CR / / 2012

TELEPHONE TECHNICAL SERVICES DS5 USER GUIDE

EURO ECO / EURO deluxe DC 2 EURO ECO DC 2 EURO deluxe. Installation Manual DC 2. DC 2 - Control Unit conforms to DIN EN 12453

Operating Instructions Pedestrian Turnstile Type MPT 33

Original Operating Manual

Electrical operating instructions

Automatic Folding Doors DORMA FFT FFT-F

Midi Traffic Light installation manual TRAFFIC CONTROL ACCESSORIES

ExitSafe. Operating instructions Retain for future reference _EN_1118

PROUD TO PROMOTE. Guide to Safety Edge Systems

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

Operating Instructions for Control CS 300

Operating instructions

User Manual. 1. Introduction

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

G E Z E AU TO M AT I C D O O R S YS T E M S VERSATILE AND COMFORTABLE B E W E G U N G M I T S Y S T E M

PORTEO PORTEO. Weight Configurations Max door weight 100kg. Parameters Max door width 1100mm Max opening angle 110

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Compact Sliding Door Operator Dor-O-Matic 2900 Series

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Operating instructions. FreeCon Contactless Power Contactless power transmission IE-CL240W-PP-BASE IE-CL240W-PP-REMOTE

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Emergency lighting units EM powerled

G E Z E AU TO M AT I C D O O R S YS T E M S VERSATILE AND COMFORTABLE B E W E G U N G M I T S Y S T E M

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

garage door operators

Emergency lighting units EM powerled

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

HIB Enclosed Inverter User Guide

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Automatic concealed bollards 275 H600 and 275 H800 with pit

Phaeton Convenience and Safety Electronics

CONTENTS. GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2

Electrical operating instructions

Talos Revolving Doors Talos Circular Sliding Doors For a stylish entrance. Convenient Transparent Timeless

INSTALLATION GUIDE Table of Contents

CB CONTROL BOARD INSTRUCTION MANUAL VERSION 1.03 DATE 30/10/2000

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

SFset with VIP 400/410 built-in control unit Medium Voltage Circuit Breaker

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Operating instructions Flow monitor SI / / 2013

GEZE AUTOMATIC DOOR SYSTEMS GEZE SLIDING DOOR SYSTEMS VERSATILE AND COMFORTABLE BEWEGUNG MIT SYSTEM

Documentation. RM-BV4 Micro DP. Filter control

ESA II CONTROLLER AND WIRING MANUAL

Electronic Ballast EVG 2000-T

access

Emergency lighting units EM powerled

2 WAY REMOTE STARTER & ALARM SYSTEM INSTALLATION GUIDE FCC ID NOTICE

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

INSTALLATION GUIDE. FCC ID NOTICE

DYNEO Synchronous motors with permanent magnets-drive Commissioning

Rolli o RTS. Quick Commissioning Guide XSE

AWZ 110. AWZ 13,8V/1A/7Ah/LM

TR10A148 RE / Instructions for Fitting, Operating and Maintenance Garage door operator

SLIDE NEW CONTROL BOARD

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

CATALOGUE 2017 AUTOMATIC DOORS

Transcription:

Automatic sliding doors DCU DCU-M EN Wiring diagram 35680-03

Automatic sliding doors Table of contents Symbols and means of representation...4 Validity...4 Product liability...4 Safety instructions...5. Important safety instructions...5. Installation details...5.3 Safety-conscious working...5.4 Inspection of the installed system...5.5 Disposal of the door system...6 Abbreviations...6 3 Safety sensor "close"...8 3. Active infrared control light curtain and radar movement detector GC 363 R...8 3. Active infrared control light curtain and self-monitored radar movement detector GC 363 SF...9 3.3 Active infrared control light curtain GC 339... 0 3.4 Active infrared control light curtain and radar movement detector GC 36 R... 0 3.5 Active infrared control light curtain and self-monitored radar movement detector GC 36 SF... 3.6 Active infrared control light curtain GC 333... 3.7 Active infrared sensor AIR 30... 3 3.8 -channel light barrier GZ 470 V... 3 3.9 -channel light barrier GZ 47 V... 4 3.0 4-channel light barrier GZ 47 V... 4 4 Safety sensor "open"... 5 4. Active infrared control light curtain GC 339... 5 4. Active infrared control light curtain GC 333... 6 4.3 Active infrared sensor AIR 30... 6 5 Break-out doors... 7 5. Break-out sensor... 7 5. Break-out sensor and safety sensor "open"... 7 5.3 Break-out sensor with active infrared control light curtain GC 339... 8 5.4 Break-out sensor with active infrared fan-shaped sensor GC 333... 8 5.5 Break-out sensor with active infrared fan-shaped sensor AIR 30... 9 6 Series connection of safety sensors... 0 6. Safety sensor "close" (standard doors)... 0 6. Safety sensor "close" (FR doors)... 6.3 Protecting the sensor cable against short-circuit... 4 7 Contact sensor authorised... 5 7. Key push button... 5 7. Emergency opening switch without illumination... 5 7.3 Emergency opening switch with illumination... 5 8 Contact sensor inside... 6 8. Standard doors... 6 8. Doors on rescue routes... 7 9 Contact sensor outside... 8 9. Radar movement detector GC 30 R... 8 9. Active infrared fan-shaped sensor GC 363 R... 8 9.3 Active infrared fan-shaped sensor and radar movement detector GC 36 R... 8 9.4 Push button (potential-free contact)... 8

Automatic sliding doors 0 Stop... 8 Programmable inputs... 9. Switch function... 9. Radio activation... 9.3 Pharmacy opening... 30.4 Emergency lock... 30 WC control... 3 3 Interlocking door system, vestibule... 3 4 Mode of operation... 33 4. Mechanical programme switch... 33 4. Switching the operating mode using push buttons or switches... 34 4.3 Keypad programme switch... 34 4.4 Display programme switch (DPS) with OFF key... 35 4.5 Display programme switch (DPS) without OFF key... 35 4.6 Display programme switch, old version (mat. no. 03940)... 36 4.7 Reset function (DPS with OFF key, TPS)... 36 4.8 Blocking or releasing operation of TPS and DPS... 36 5 Configurable outputs... 37 5. PA (gong)... 37 5. PA (fault, fan)... 37 6 Mains connection... 38 7 Locking... 39 7. Locking by toothed belt... 39 7. Rod locking, break axle... 39 7.3 Hook bolt Lock A... 40 8 Rechargeable battery... 40 9 Motor... 4 0 Control... 4 Commissioning and service... 43. Production test... 43. Commissioning... 43.3 Service... 46 Service menu... 47. Service terminal ST0... 47. Display programme switch (DPS)... 57 3 Fault messages... 64 3. Display programme switch... 64 3. Keypad programme switch... 65 3

Automatic sliding doors Symbols and means of representation Warnings In these instructions, warnings are used to warn against material damage and injuries. Always read and observe these warnings. Observe all the measures that are marked with the warning symbol and warning word. Warning symbol Warning word Meaning DANGER Danger to persons. Non-compliance will result in death or serious injuries. WARNING CAUTION Danger to persons. Non-compliance can result in death or serious injuries. Danger to persons. Non-compliance can result in minor injuries. Other symbols and means of representation Important information and technical notes are highlighted to explain correct operation. Symbol Meaning means "important note" means "additional information" X X Symbol for an action: Here you have to do something. If there are several actions to be taken, keep to the given order. Escape and rescue route Symbol in a table or for a piece of information only applicable to escape and rescue route doors. Not an escape and rescue route Symbol in a table or relating to information which applies to standard doors without an escape and rescue route function. Conforms to DIN 8650/EN 6005 Does not conform to DIN 8650 / EN 6005 Symbol in a table or relating to information on safety sensors that are standard-compliant. Symbol in a table or relating to information on safety sensors that are not standard-compliant. Validity Valid for units with Hardware: DCU Rev D, DCU-M Rev D; Software: DCU V3.3, DCU-M V3.3 Product liability In accordance with the manufacturer's liability for their products as defined in the German "Produkthaftungsgesetz" (Product Liability Act), the information contained in this brochure (product information and proper use, misuse, product performance, product maintenance, obligations to provide information and instructions) is to be noted and followed. Failure to comply releases the manufacturer from his statutory liability. 4

Automatic sliding doors Safety instructions Safety instructions. Important safety instructions It is important to follow these instructions for the safety of persons. These instructions must be kept. Only specialists authorised by GEZE are permitted to carry out installation, commissioning and maintenance work. Unauthorised modifications to the system exclude GEZE from liability for any resulting damages. GEZE makes no guarantee for combinations with third-party products. Use only original GEZE parts for repair and maintenance work as well. The connection to the mains voltage must be carried out by a qualified electrician. Perform the power connection and equipment earth conductor test in accordance with VDE 000 Part 60. Use an on-site 0-A overload cut-out as the line-side disconnecting device. Attach safety stickers to glass door leaves, mat. no. 08476. In accordance with Machinery Directive 98/37/EC, a safety analysis is to be performed and the door system identified in accordance with CE Identification Directive 93/68/EEC before the door system is commissioned. Observe the latest versions of directives, standards and country-specific regulations, in particular: AutSchR "Guidelines on automatic sliding doors in escape and rescue routes" EN 6005 "Power operated pedestrian doorsets Safety in use Requirements and test methods" DIN 8650, Part and Part "Automatic door systems" DIN VDE 00-600 "Installation of low-voltage systems - Part 6 Tests" DIN EN 60335--03 "Safety of electrical devices for home use and similar purposes; special requirements for drives, for gates, doors and windows" Accident Prevention Regulations, in particular BGV A (VBG) "General Regulations" and BGV A3 (VBG4) "Electrical Installations and Resources". Installation details The drive is designed only for use in dry rooms. Only use the cables prescribed in the cable plan provided. Lay shields in accordance with the wiring diagram. Always use insulated wire-end ferrules for wire cores. Insulate the wires that are not used. Secure loose, internal drive cables with cable ties. Observe the maximum permitted overall current drain required to supply the periphery..3 Safety-conscious working Secure the workplace against unauthorised entry. Watch the swivelling range of long system parts. Secure the hood/drive shrouding against falling. X X Before carrying out work on the electrical system, cut the power supply (mains and battery) and check to ensure that there is no power. When using an uninterrupted power supply (UPS), the system will still be under power even when disconnected from the mains. Risk of injury by moving parts (drawing in of hair, clothing,...) when a drive is opened. Risk of injury caused by unsecured crushing, impact, drawing-in or shearing spots. Risk of injury caused by sharp edges in the drive. Risk of injury due to glass breakage..4 Inspection of the installed system Measures for checking safety and prevention of crushing, impact, shearing or drawing-in spots. X X Check the function of the presence sensors and movement detectors. The detection field of the movement detector in the direction of emergency exit must cover the opening width (ÖW).5 m in front of the door. Check the protective earth connection to all metal parts that can be touched. 5

Abbreviations Automatic sliding doors.5 Disposal of the door system The door system is made up of materials that should be sent for recycling. For this purpose, the individual components should be sorted corresponding to material type: Aluminium (profiles, covering, return pulleys, sliding blocks,...) Iron (drivers, screws,...) Plastic Electronic parts (bolts, motor, control, transformer, sensors,...) Cable Rechargeable battery The parts listed should be handed in to communal collection points or be disposed of via a scrap recycling company. Rechargeable batteries and batteries contain pollutants and heavy metals. Rechargeable batteries and waste batteries should be handed in to communal collection points or retailers. The rechargeable battery for the drive is a plug-in type and connected to the control; it can be removed easily by loosening two fixing screws. Information regarding the Battery Directive: (Applicable in Germany and in all other member states of the European Union as well as in other European countries, together with the countries' own provisions for a separate waste battery collection system.) In accordance with the Battery Directive, we are obliged to inform you of the following in connection with the sale of batteries or rechargeable batteries respectively in connection with the delivery of devices containing batteries or rechargeable batteries: Rechargeable batteries and batteries must not be disposed of with household waste. Disposal with household waste is expressly forbidden according to the Battery Directive. As the final consumer, you are bound by law to return waste batteries and rechargeable batteries. Please return waste batteries and rechargeable batteries to a communal collection point or retailer. Following use, you may return any batteries or rechargeable batteries received from us by post. The address is: GEZE GmbH, Incoming Goods, Reinhold-Vöster-Str. -9, 79 Leonberg/Germany. Abbreviations Wire colours BK BU brown black blue YE green grey yellow OG P-K RD orange pink red TQ VT turquoise violet white 6

Automatic sliding doors Connections, terminals and plugs AIR Active infrared MB control light curtain MB APO Pharmacy opening MPS AU Automatic DO Permanently open NA DPS Display programme N.C. switch NC ENC Incremental encoder D Reference potential IR Infrared TVER KA Contact sensor OFF outside ÖW KB Contact sensor PA authorised PE KI Contact sensor PROG inside PS LK Luster terminal RBM LCK_A Locking, A RUN LCK_B Locking, B RS485 LKD Locked LS Shop closing MA Motor, A MA Motor, A Motor, B Motor, B Mechanical programme switch Night Not used Opening contact (normally closed) Closer contact (normally open) Emergency lock Off Opening width Output programmable Input programmable Programming interface Programme switch Radar movement detector Status display Communication signal to DPS, TPS Abbreviations SABO Sabotage SCR Shield SHLD Shield SIO Safety sensor "open" SIS Safety sensor "close" ST0 Service terminal ST0 (mat. no. 0876) STG Fault SYNC Synchronisation TEMP Temperature sensor Test Test input TPS Keypad programme switch TST Test signal safety sensors ULKD Unlocked +UB Supply voltage + UB Supply voltage 4V Supply voltage for external devices, max..0 A 4VAKKU Supply during mains power failure, max. 0 ma PE PE PA PA PE PE PA PA DCU03 5 PE 55 PAA STOP PS SIS SIO 5 PE 56 57 PAB PA RUN PROG PE3 SIO SIS SIS SIS SIO 4 SIO LOCK KI KA KB RS485 0 TST 0 TST STOP 5 STOP KI KI (Kl) KA 3 KA PS 6 NA 7 LS 8 AUT 9 DO KB 3 4VAKKU 0 KB PE3 PE3 (Kl) SIO 3 SIO 0 TST SIS SIS 0 TST 7

Safety sensor "close" Automatic sliding doors 3 Safety sensor "close" Up to four safety sensors "close" can be connected (terminals SIS, SIS, SIO and SIO). During detection, the output of the safety sensor "close" is open. D is applied to the input. Set the contact type for the terminal used: With DPS: s, s, s3 or s4 to o With ST0: "SI-", "SI-", "SI3-" or "SI4-contact type" to "opener" Set the function for detection (see Service menu chapter): With DPS: f, f, f3 or f4 With ST0: "SI-", "SI-", "SI3-" or "SI4-function" Check function and correct setting of the sensors during commissioning and service. 3. Active infrared control light curtain and radar movement detector GC 363 R Installation height max. 3500 mm GC 363 R black, mat. no. 537 GC 363 R according to RAL, mat. no. 538 The GC 363 R contains an active infrared control light curtain and a direction-sensitive radar movement detector. GC 363 R 0 ma RBM -UB +UB COM + PK BU RD YE SIS or oder SIS SIS SIS 0 TST 0 TST KI KI KA 3 KA AIR curtain Test In order to safeguard the closing process in compliance with EN 6005 and DIN 8650, a light curtain must be installed on both the inside and outside. The detection field of the light curtain on the floor must cover the whole door width. Follow installation instructions GC 363 R / SF. Necessary parameter adjustment GC 363 R Output configuration: EEL: OUTPUT to () AIR: OUTPUT to (NC) Necessary setting on the control Set parameter Ci (contact sensor inside, contact type) or Co (contact sensor outside, contact type) to 0 (closer). 8

Automatic sliding doors Safety sensor "close" 3. Active infrared control light curtain and self-monitored radar movement detector GC 363 SF Installation height max. 3500 mm GC 363 SF black, mat. no. 539 GC 363 SF according to RAL, mat. no. 540 The GC 363 SF contains an active infrared control light curtain and a self-monitored, direction-sensitive radar movement detector with frequency output (00 Hz). Follow installation instructions GC 363 SF. Set the detection field and sensitivity of the radar movement detector as per AutSchR: Detection field = ÖW.5 m, speed greater than 0 cm/s. GC 363 SF 0 ma RBM COM + +UB 3 3 PK BU RD YE YE/BK /BK or oder SIS SIS 0 TST KI KI 4 V SIS SIS 0 TST KA 3 KA AIR curtain Test 3 not used In order to safeguard the closing process in compliance with EN 6005 and DIN 8650, a light curtain must be installed on both the inside and outside. The detection field of the light curtain on the floor must cover the whole door width. Necessary parameter adjustment GC 363 SF Output configuration: EEL: OUTPUT to 6 (freq) AIR: OUTPUT to (NC) Necessary setting on the control Set parameter Ci (contact sensor inside, contact type) or Co (contact sensor outside, contact type) to 04 (frequency). 9

Safety sensor "close" Automatic sliding doors 3.3 Active infrared control light curtain GC 339 GC 339 black, mat. no. 55 GC 339 according to RAL, mat. no. 55 Follow installation instructions GC 339. Insulate unused wires (, YE). oroder GC 339 SIS 4 V 0 ma SIS SIS SIS PK COM + BU 0 TST 0 TST RD YE AIR curtain Test Necessary parameter adjustment GC 339 Output configuration: AIR: OUTPUT to (NC) 3.4 Active infrared control light curtain and radar movement detector GC 36 R Installation height max. 3000 mm GC 36 R black, mat. no. 753 GC 36 R according to RAL, mat. no. 3057 GC 36 R 5 ma RBM -UB +UB COM + PK BU RD YE or oder SIS SIS SIS SIS 0 T ST 0 T ST KA KI 3 KA KI AIR curtain Test The GC 36 R contains an active infrared control light curtain and a direction-sensitive radar movement detector. Follow installation instructions, mat. no. 865. Accessories recommended for setting the sensor: Remote control, mat. no. 0006. Accessories recommended for setting the light curtain: Infrared detector, mat. no. 3 Accessories: Ceiling installation kit, black, mat. no. 5533 Ceiling installation kit, white, mat. no. 553 Ceiling bracket, mat. no. 5534 Rain cover, mat. no. 6830 0

Automatic sliding doors Safety sensor "close" To safeguard the closing movement, a light curtain with a detection field covering the entire door width on the floor and monitoring the area up to a height of at least,000 mm above the ground (where the main closing edge meets the opposite closing edge) must be mounted both inside and outside as per DIN 8650. The distance between the detection fields must not exceed 00 mm. If only one light curtain is used, the detection field must be located on the floor as close to the door leaf as possible. Set the tilt angle of the optic block accordingly for this purpose. Half- or fully-grooved prism: wide/narrow detection field of the IR curtain 3-piece/6-piece aerial insert: wide/narrow detection field of the radar movement detector Necessary parameter adjustment GC 36 R Output configuration: (radar output active, IR output passive) Presence detection duration: to 6 ( to 60 minutes); the value 0 (30 sec.) is not permitted. Monitoring mode: (on) Multi mode: If adjacent light curtains overlap, set different infrared frequencies. Necessary setting on the control X X Set Ci (contact sensor inside, contact type) or Co (contact sensor outside, contact type) to 0 (closer). 3.5 Active infrared control light curtain and self-monitored radar movement detector GC 36 SF Installation height max. 3000 mm GC 36 SF black, mat. no. 709 GC 36 SF according to RAL, mat. no. 3056 GC 36 SF 5 ma RBM -UB +UB COM + PK BU RD YE or oder SIS SIS SIS SIS 0 T ST 0 T ST KI KI AIR curtain Test The GC 36 SF contains an active infrared control light curtain and a self-monitored, direction-sensitive radar movement detector with frequency output (00 Hz). Follow installation instructions, mat. no. 869. The GC 36 SF is used in the direction of emergency exit. Set the detection field and sensitivity of the radar movement detector as per AutSchR: Detection field = ÖW.5 m, speed greater than 0 cm/s. Necessary setting on the control X X Set Ci (contact sensor inside, contact type) or Co (contact sensor outside, contact type) to 04 (frequency).

Safety sensor "close" Automatic sliding doors Necessary parameter adjustment GC 36 SF Output configuration: (IR output passive) Presence detection duration: to 6 ( minute to 60 minutes), the value 0 (30 s) is not permitted. Monitoring mode: (on) Multi mode: If adjacent light curtains overlap, set different infrared frequencies. The connection of two radar movement detectors of type GC 36 SF in the direction of emergency exit is not possible. Instead, use sensor GC 363 SF incl. GC 363 S interface (see chapter 6..). 3.6 Active infrared control light curtain GC 333 Installation height up to 3000 mm GC 333 black, mat. no. 755 GC 333 according to RAL, mat. no. 3058 GC 333 5 ma -UB +UB COM PK BU RD * or oder SIS SIS SIS SIS 0 T ST 0 T ST YE* The GC 333 contains an active infrared control light curtain. Follow installation instructions, mat. no. 873. For further information see GC 36 R (SIS). Accessories: Ceiling installation kit, black, mat. no. 5533 Ceiling installation kit, white, mat. no. 553 Ceiling bracket, mat. no. 5534 Rain cover, mat. no. 6830 Accessories recommended for setting the sensor: Remote control, mat. no. 0006 Accessories recommended for setting the light curtain: Infrared detector, mat. no. 3 AIR curtain Test * Insulate unused wires (, YE) Necessary parameter adjustment GC 333 Monitoring mode: (on)

Automatic sliding doors Safety sensor "close" 3.7 Active infrared sensor AIR 30 AIR 30, mat. no. 07393 Relay, mat. no. 0335 AIR 30 00 ma -UB +UB 3 4 5 YE A or oder SIS SIS SIS SIS 0 T ST 0 T ST A Test Illustration: Static condition with operating voltage switched on Follow the installation instructions. Only use the AIR 30 as an additional sensor for monitoring closing. An AIR 30 sensor alone is not sufficient to meet the requirements as per DIN 8650. Set the light/dark selector switch to (D) (setting dark-switching) Adjust the sensing width to 0. m above the floor using the adjustment screw. 3.8 -channel light barrier GZ 470 V GZ 470 V, mat. no. 76 3 RD BK BK or oder SIS SIS 0 T ST N.C. SIS SIS 0 T ST Installation.0 m above the floor. Current consumption GZ 470 V: 50 ma GZ 470 V receiver max. 5 m 3 GZ 470 V transmitter The side distance between the light barrier axis and the sliding panel level must not exceed 5 cm. 3

Safety sensor "close" Automatic sliding doors 3.9 -channel light barrier GZ 47 V GZ 47 V, mat. no. 77 GZ 47 ES V transmitter GZ 47 ES V receiver 3 max. 5 m 4 GZ 47 SE V transmitter 5 GZ 47 SE V receiver BK BK 3 RD 4 5 RD BK BK or oder SIS SIS 0 T ST SIS SIS 0 T ST Installation 0. m and.0 m above the floor respectively. Current consumption GZ 47 V: 70 ma The side distance between the light barrier axis and the sliding panel level must not exceed 5 cm. 3.0 4-channel light barrier GZ 47 V According to DIN 8650 safeguarding with light barriers is not suitable for people in need of special protection. Note and follow other standard-related requirements such as power limitation etc. GZ 47 V, mat. no. 77 Install one channel 0. m above the ground, another one.0 m above the ground and the other channels as required. Install GZ 47 SE V on the left, GZ 47 ES V on the right in each case. Current consumption GZ 47 V: 70 ma BK BK 3 RD RD BK BK SIS SIS 0 TST 4 5 BK BK RD GZ 47 ES V transmitter GZ 47 ES V receiver 3 max. 5 m 4 GZ 47 SE V transmitter 5 GZ 47 SE V receiver 3 RD 4 5 BK BK SIS SIS 0 TST The side distance between the light barrier axis and the sliding panel level must not exceed 5 cm. 4

Automatic sliding doors Safety sensor "open" 4 Safety sensor "open" Check function and correct setting of the sensors during commissioning and service. Up to four safety sensors "open" can be connected (terminals SIO, SIO, SIS and SIS). During detection, the output of the safety sensor "open" is open. D is applied to input SIO or SIO. Set contact type for terminals used: With DPS: Set s3, s4, s or s to o. ST0: Set parameter "SI3", "SI4", "SI" or "SI contact type" to "open" Set function for terminals used (see Chapter 3): Set DPS parameter f3, f4, f or f. Set ST0 parameter "SI3-", "SI4-", SI-" or "SI-function". For doors in rescue routes: If the safety sensor "open" is activated during opening, the door does not stop until the reduced opening width is reached. The reduced opening width must be larger than or the same size as the required escape route width (official building approval). 4. Active infrared control light curtain GC 339 Installation height max. 3500 mm GC 339 black, mat. no. 55 GC 339 according to RAL, mat. no. 55 Follow installation instructions GC 339. Insulate unused wires (, YE). GC 339 0 ma -UB +UB PK SIO 3 SIO 0 TST SIO 4 SIO 0 TST COM + BU RD YE AIR curtain Test Necessary parameter adjustment GC 339 Output configuration: AIR: OUTPUT to (NC) AIR width: For installation in open position right: Set AIR width to the right-hand sub-panel. For installation in open position left: Set AIR width to the left-hand sub-panel. 5

Safety sensor "open" Automatic sliding doors 4. Active infrared control light curtain GC 333 Installation height up to 3000 mm GC 333 black, mat. no. 755 GC 333 or * YE* AIR curtain Test * Insulate unused wires (, YE) Necessary parameter adjustment GC 333 Monitoring mode: (on) Follow installation instructions, mat. no. 873. Prism 0.5 m left for monitoring the right-hand fixed panel, 0.5 m right for monitoring the left-hand fixed panel (the prisms are included with the sensor). 4.3 Active infrared sensor AIR 30 AIR 30, mat. no. 07393 Relay, mat. no. 0335 AIR 30 00 ma -UB +UB 3 4 5 YE A or oder SI O SI O 3 SI O 4 SI O 0 T ST 0 T ST A Test Follow the installation instructions. For further information see AIR 30 (SIS). Illustration: Static condition with operating voltage switched on 6

Automatic sliding doors Break-out doors 5 Break-out doors Before commissioning, set the drive type in the Service menu "Door parameters" "Drive type" (Slimdrive SL BO, ECdrive BO or TSA 360NT BO). Note the contents of the "Guidelines on automatic sliding doors in escape and rescue routes (AutSchR)": The programme switch must be protected from unauthorised access e.g. by installing a key push button to block the programme switch. The functions emergency lock, interlocking door system and vestibule are not permitted with automatic sliding doors on rescue routes. The operating mode setting "Night" with timer or switch is not possible. The function "pharmacy" is not available as an input parameter. Break-out sensor, mat. no. 0764 The break-out sensors monitor the position of the swing leaves. They are connected to the inputs SIO or SIO together with any safety sensors "open" that are available. When the break-out sensor is triggered, the door stops during opening and closing. Break-out sensors SIO is configured automatically. If used, SIO must be configured to contact type "opener" and function "break-out". When the side part has been swung out, the break-out sensor output is open. D is applied to input SIO or SIO. 5. Break-out sensor With -leaf systems one break-out sensor is mounted (SIO), any safety sensor open that is available is connected to SIO. With -leaf systems two break-out sensors are mounted (inputs SIO and SIO of the control unit). SIO or oder SIO Break-out sensor Break-Out Sensor YE 3 SIO D 4V 4 SIO D 4V 0 TST 0 TST 5. Break-out sensor and safety sensor "open" Two break-out sensors and two safety sensors "open" can be connected (inputs SIO and SIO of the control). During detection, the output of the safety sensor "open" is open. D is applied to input SIO or SIO. When a break-out sensor or a safety sensor "open" is triggered, the door stops during opening and closing. 7

Break-out doors Automatic sliding doors 5.3 Break-out sensor with active infrared control light curtain GC 339 For further information see section 3.3 Active infrared control light curtain GC 339. GC 339 0 ma -UB +UB PK SIO 3 SIO 0 TST SIO 4 SIO 0 TST COM + BU RD * YE* VB Break-out sensor Break-Out Sensor YE AIR curtain Test * Insulate unused wires (, YE) VB Connection of the wires and fixing of sensor cables (see section 6.3 Protecting the sensor cable against short-circuit) 5.4 Break-out sensor with active infrared fan-shaped sensor GC 333 Further information in chapter 4. Active infrared control light curtain GC 333 GC 333 5 ma -UB +UB COM + Break-out sensor Break-Out Sensor PK BU RD * YE* VB YE SIO or oder SIO 3 0 SIO D 4V TST 4 0 SIO D 4V TST D 4V AIR curtain Test * Insulate unused wires (, YE) VB Connection of the wires and fixing of sensor cables (see chapter 6.3 Protecting the sensor cable against short-circuit) 8

Automatic sliding doors Break-out doors 5.5 Break-out sensor with active infrared fan-shaped sensor AIR 30 AIR 30 00 ma -UB +UB 3 4 5....YE. VB 3.YE A.... SIO or 3 SIO 0 TST oder SIO 4 SIO 0 TST A 3. 3. 3. Break-out sensor Break-Out Sensor.YE... VB., 3..,., 3. Test VB Connection of the wires and fixing of sensor cables (see section 6.3 Protecting the sensor cable against shortcircuit) Illustration: Static condition with operating voltage switched on For further information see chapter 4.3 Active infrared sensor AIR 30 9

Series connection of safety sensors Automatic sliding doors 6 Series connection of safety sensors 6. Safety sensor "close" (standard doors) 6.. Active infrared control light curtain (GC 339, GC 333) with safety/activation sensor (GC 363 R, GC 36 R) GC 339 and GC 363 R meet the requirements as per EN 6005 and DIN 8650. GC 333 and GC 36 R meet the requirements as per DIN 8650. For GC 363 R, GC 36 R: Connect the AIR output directly to terminal SIS of the control. For GC 36 / GC 333: Set the parameter "TEST (monitoring" to On []. GC 363 R, GC 36 R -UB 4V +UB RBM..Sensor COM + PK BU RD YE or SIS oder SIS 0 TST DCU-M DCU 3 KA SIS SIS 0 TST DCU KI GC 339, GC 333 4V -UB +UB PK VB..Sensor GC 339, GC 333 4V COM + -UB +UB BU RD YE PK or ODER VB or Oder 3rd sensor 3. Sensor 3rd 3.Sensor sensor COM + BU RD YE AIR curtain Test VB Connection of the wires and fixing of sensor cables (see section 6.3 Protecting the sensor cable against short-circuit) 0

Automatic sliding doors Series connection of safety sensors 6.. Safety/activation sensors GC 363 R (GC 36 R) GC 363 R meets the requirements as per EN 6005 and DIN 8650. GC 36 R meets the requirements as per DIN 8650. For GC 36: Set the parameter "TEST (monitoring" to On []. GC 363 R, GC 36 R -UB 4V +UB COM + RBM PK BU RD YE or SIS oder SIS 0 TST SIS SIS 0 TST. Sensor VB GC 363 R, GC 36 R -UB 4V +UB PK RBM COM + BU RD YE DCU-M DCU KA 3 KA DCU KI KI. Sensor AIR curtain Test VB Connection of the wires and fixing of sensor cables (see section 6.3 Protecting the sensor cable against shortcircuit) Illustration: Static condition with operating voltage switched on

Series connection of safety sensors Automatic sliding doors 6. Safety sensor "close" (FR doors) 6.. Active infrared control light curtain (GC 339, GC 333) with safety/activation sensor (GC 363 SF, GC 36 SF) GC 339 and GC 363 SF meet the requirements as per EN 6005 and DIN 8650. GC 333 and GC 36 SF meet the requirements as per DIN 8650. For GC 363 R, GC 36 R: Connect the AIR output directly to terminal SIS of the control. For GC 36 / GC 333: Set the parameter "TEST (monitoring" to On []. GC 363 SF 0 ma RBM COM + +UB 3 3 PK BU RD YE YE/BK /BK VB SIS or oder SIS SIS SIS 0 TST 0 TST DCU-M DCU KA KI DCU KA 3 KA..Sensor GC 339, GC 333 4V -UB +UB PK COM +..Sensor GC 339, GC 333 -UB 4V +UB COM + 3. 3.Sensor BU RD YE PK BU RD YE or ODER VB or 3rd Oder sensor 3. Sensor AIR curtain Test 3 not used VB Connection of the wires and fixing of sensor cables (see chapter 6.3 Protecting the sensor cable against short-circuit)

Automatic sliding doors Series connection of safety sensors 6.. Safety/activation sensor GC 363 SF Two interfaces GC 363 S and two relays are required for the series connection of two GC 363 SF. For further information see section 3. Active infrared control light curtain and self-monitored radar movement detector GC 363 SF Set the parameters: Ci (KI contact type) to 0 (opener redundant). E3 (PE3 function) to 0 (KI ). Accessories: Interface GC 363 S, mat. no. 536 Relay (with free-wheeling diode), mat. no. 0335 GC 363 SF setting: EEL: OUTPUT to 5 (current/nc) GC 363 SF V - 4V -UB +UB YE RBM +UB COM + +UB BU RD Interface GC 363 S PK YE/BK /BK GC 363 SF V - 4V +UB RBM -UB +UB COM + +UB YE BU RD VB VB VB DCU-M or SIS ODER 4 V SIS 4 V 0 TST 4 V SIS SIS 4 V 0 TST Interface GC 363 S PK YE/BK /BK VB VB 3 A (+) 3 4 A (+) 4 A (-) A (-) DCU-M KI KI PE3 PE3 AIR curtain Test 3 Relay (with free-wheeling diode) VB Connection of the wires and fixing of sensor cables (see section 6.3 Protecting the sensor cable against short-circuit) Illustration: Static condition with operating voltage switched on 3

Series connection of safety sensors Automatic sliding doors 6.3 Protecting the sensor cable against short-circuit When connecting the sensor cables to the plug-type connectors SIS, SIS, SIO, SIO use the following method: Combine several wires to be connected in one wire-end ferrule Connect VB wires using an insulated parallel connector Parallel connectors: e.g. Bürklin, order no. 07F680 Use shrink tubing to insulate wires until the start of the cable sheath. The shrink tubing must project 0 mm over the insulated parallel connector. Lay the insulated wires backwards over the cable sheaths. Insulate non-used wires and lay them backwards over the cable sheaths. Fix wires and cables using cable ties. Secure sensor cables against movement Fix the sensor cables to the cable holder using a cable tie (). 4

Automatic sliding doors Contact sensor authorised 7 Contact sensor authorised The input KB is active in operating modes au, ls and Na. When activated, the output of the contact sensor authorised is closed (4 V AKKU is applied to the KB input). When KB is activated, the door opens fully, even if the operating mode au winter is set. Do not use terminal strip "KB" for supplying external loads (e.g. number codelock). Otherwise the battery will not be charged. Key push button SCT, single-pole, flush-mounted, AS 500 without profile half cylinder, mat. no. 7996 Accessories: Profile half cylinder, mat. no. 09076 Additional contact, mat. no. 04467 (the additional contact is not a sabotage contact, it is intended to release the DPS or TPS) 7. Key push button KB 3 4VAKKU 0 KB 7. Emergency opening switch without illumination Mat. no. 067846 After activation, the housing must be opened with the appropriate key and the unlock lever activated in order to unlock the switch. 3 KB 3 4VAKKU 0 KB 7.3 Emergency opening switch with illumination Surface-mounted, AS 500, alpine white, mat. no. 37967 Flush-mounted, mat. no. 3657 After activation, the switch must be unlocked by pulling out the mushroom button. T30 8 9 3 0 ma KB 3 4VAKKU 0 KB 5

Contact sensor inside Automatic sliding doors 8 Contact sensor inside The KI input is active in operating modes au and ls. 8. Standard doors During activation, the output of the contact sensor inside is closed (4 V are applied to the KI input). 8.. Radar movement detector GC 30 R GC 30 R black, mat. no. 4087 GC 30 R according to RAL, mat. no. 4088 The remote control does not work with detector hood mounted, LED not visible. The GC 30 R is a direction-sensitive radar movement detector. GC 30 R 85 ma +UB -UB 3 4 BK BU KI D 4V KI 5 Follow installation instructions, mat. no. 3457. Accessories: Remote control, mat. no. 099575 Ceiling installation set, mat. no. 5384 Rain cover, mat. no. 5339 If several GC 30 R units are installed near to one another or behind one another, set different device addresses using the two DIP switches. Otherwise the settings of the other detectors will also be changed by the remote control. 8.. Active infrared fan-shaped sensor and radar movement detector GC 363 R See GC 363 R (SIS), chapter 3. Active infrared control light curtain and self-monitored radar movement detector GC 363 SF. 8..3 Active infrared fan-shaped sensor and radar movement detector GC 36 R See GC 36 R (SIS), chapter 3.4 Active infrared control light curtain and radar movement detector GC 36 R 8..4 Push button (potential-free contact) Plastic elbow switch, white, mat. no. 4078 Plastic elbow switch, stainless steel, mat. no. 4077 Stainless steel elbow switch, mat. no. 9898 Stainless steel elbow switch LS 990, surfacemounted, mat. no. 858 Stainless steel elbow switch LS 990, flush-mounted, mat. no. 8583 KI KI 6

Automatic sliding doors Contact sensor inside 8. Doors on rescue routes Install self-monitored movement detector in the direction of emergency exit. Upon activation, the output of the contact sensor inside is open; D is applied to the KI input. Set the detection field and sensitivity of the radar movement detector as per AutSchR: Detection field = ÖW.5 m, speed greater than 0 cm/s. 8.. Radar movement detector GC 30 SV GC 30 SV, black, mat. no. 4089 GC 30 SV +UB 50 ma -UB Uout - Uout + 3 4 5 BK BU KI D 4V KI not used GC 30 SV according to RAL, mat. no. 4090 (the remote control does not work with detector hood mounted, LED not visible) GC 30 SV is a self-monitored direction-sensitive radar movement detector with analogue voltage output (0 V 0 V). Follow installation instructions, mat. no. 3456. DPS: Set parameter ci to 03. ST0: Set parameter "KI contact type" to "voltage". For further information see GC 30 R (KI), chapter 8.. Radar movement detector GC 30 R. 8.. Active infrared fan-shaped sensor and radar movement sensor GC 36 SF See GC 36 SF (SIS), chapter 3.5 Active infrared control light curtain and self-monitored radar movement detector GC 36 SF. 7

Contact sensor outside Automatic sliding doors 9 Contact sensor outside The KA input is only active in operating mode au. During activation, the output of the contact sensor outside is closed (4 V applied at the KA input). 9. Radar movement detector GC 30 R See GC 30 R (KI), chapter 8.. Radar GC 30 R movement detector GC 30 R. +UB 85 ma BK -UB 3 BU 4 KA 3 D 4V KA 5 9. Active infrared fan-shaped sensor GC 363 R See GC 363 R (SIS), chapter 6.. Active infrared control light curtain (GC 339, GC 333) with safety/activation sensor (GC 363 R, GC 36 R). 9.3 Active infrared fan-shaped sensor and radar movement detector GC 36 R See GC 36 R (SIS), chapter 6.. Active infrared control light curtain (GC 339, GC 333) with safety/activation sensor (GC 363 R, GC 36 R). 9.4 Push button (potential-free contact) See push button (KI), chapter 8..4 Push button (potential-free contact). KA 3 KA 0 Stop, k,0 k STOP 5 STOP, k,0 k STOP 5 STOP With DPS: cn = 0 cn = 0 cn = cn = 0 With STOP contact type ST0: Terminating. kω STOP contact type = closer STOP contact type = opener Terminating Terminating.0 kω For personal protection as per DIN 8650 and EN 6005: Connect terminating resistance to monitor the input in accordance with the configuration. 8

Automatic sliding doors Programmable inputs Programmable inputs The control features three programmable inputs, PE (terminal 5), PE (terminal 5) and PE3 (terminal ), that can be allocated different control functions. The inputs can be programmed using the display programme switch DPS or the service terminal ST0. The functions are described in the Service menu DPS section ( nd menu) and in the Service terminal ST0 section (Configurable inputs).. Switch function With DPS: Set e, e or e3 to 0 (switch function) or (switch function with closing after holdopen PE PE or oder or oder time). PE PE PE 3 With ST0: Set PE-, PE- or PE3-function to "switch function" or "switch function OHZ". 5 PE 5 PE PE 3 During activation, the push button is closed (4 V is applied to inputs PE, PE and PE3). The first switch contact opens the door and the next closes the door. For the switch function with closing after the hold-open time, the door closes automatically after the holdopen time elapses providing it was not closed via the switch beforehand. Check whether the door always opens completely with switch contact even if the operating mode "AU" winter is set.. Radio activation Follow installation instructions and user manual. Parameter setting of contact type with: DPS: Set E, E or E3 to the required function (8, 9, 0,, 4). ST0: Set "input signals", "configurable inputs", "PE function", "PE function" or "PE3 function" to the required function. Push button with transmitting module WRM-4 4V 4V or PE, PE oder or PE, PE oder PE3 D D 4V 4V 4V OUT 5 PE 5 PE PE3 D OUT A B The receiving module WRM-4 can be activated with the transmitting module WTM. Transmitting module WTM, mat. no. 3, for clipping into a plastic elbow switch. Follow the installation instructions for the wireless programme AUT. YE WTM 9

Programmable inputs Automatic sliding doors.3 Pharmacy opening Set function parameter for input used: With DPS: Set e, e or e3 to 06. PE PE With ST0: Set "PE-", "PE-" or "PE3-function" to "pharmacy". 5 PE or oder or oder PE PE 5 PE PE 3 PE 3 During activation, 4 V is applied to the input. The pharmacy opening function is only active in the Na operating mode. Use a push button as the activation element..4 Emergency lock Set parameter for input (terminal) used: With DPS: Set e, e or e3 to 07. With ST0: Set "PE-", "PE-" or "PE3-function" to "emergency lock". or oder PE3 or oder PE PE PE 3 5 PE PE PE 5 PE The door closes and locks as soon as the contact is closed. 4 V are applied to the control. The door remains closed and locked as long as the contact is closed. When the emergency lock is active, the safety sensors "close" (SIS) and obstruction detection are not active. 30

Automatic sliding doors WC control WC control (not with DCU-M) Setting the parameters with: DPS: Set E, E or E3 to (WC control), depending on the input used. Set A to 4 (LS). Set A to 4 (fault WC timeout) if monitoring of permanent locking is required (signal horn to the lodge) Set AC to 0 (open) or 03 (battery operation max. 30 minutes / 30 cycles, then open). ST0: Set "input signals", "PE-function", "PE-function" or "PE3 function" to "WC control". Set "output signals", "PA function" to "shop closing". Set "Door parameters", "Power failure not NA" to "open" or "30 min open". Accessories: AS 500 switch unit with illuminated display for disabled WC, mat. no. 088 ( units required) Optional: SLH0, SIAL HORN, flush-mounted, AS 500, AW, COMPLETE, mat. no. 5939 Push button with illuminated display "occupied" + PE, PE 5 PE PA PA 55 PAA 56 PAB 57 PA or oder or oder 5 PE PE3 3 KA 3 KA + Inside push button (switch unit with illuminated display) OCCUPIED 3 Outside push button (switch unit with illuminated display) Function The control recognises the operating function "WC control" on the basis of the parameter set for the configurable input (PE, PE, PE3). If the WC is not occupied, the door is in automatic mode and is in the closed position. The OCCUPIED signs are off. When the "outside push button" is activated, the WC door is opened. Once someone has entered the cubicle, the WC door is switched to shop closing mode by pressing the "inside push button" and the outside push button is blocked. The OCCUPIED signs light up. The drive keeps the door locked in the closed position by means of motor power. Pressing the "inside push button" again switches the operating mode back to automatic. The OCCUPIED signs go out. The door opens and the "outside push button" is cleared again. When WCs are monitored for permanent locking, the "WC alarm" signal is triggered after 30 minutes and an acoustic signal (signal horn to the gate) is switched on. The time cannot be set. In an emergency, the toilet door can be opened from the outside using the emergency opening switch. In the event of power failure, the door opens or remains in operation for max. 30 minutes or 30 cycles and then opens, depending on the AC parameter setting (power failure not NA). 3

Interlocking door system, vestibule Automatic sliding doors Signal horn + - PA PA 55 PAA 56 PAB 57 PA Signal horn SLH0 to the lodge (optional) Emergency opening switch See "emergency opening switch", chapter 7 Contact sensor authorised. 3 Interlocking door system, vestibule Two sliding doors use the same programme switch. The programme switch only indicates the fault messages of the first control. Interlocking door system: One door only opens if the other one is closed. Vestibule: Both doors run in the same mode of operation. Do not connect terminal. The programme switch is connected to the first control. Set parameters with DPS: RS485 D 4V RS485 -A RS485 -B SCR 4 4 43 Control door First control: sl = 00 Control door Second control sl = 0 for interlocking door system sl = 0 for vestibule Set parameters with ST0: First control: "Interlocking door system vestibule = Master" Second control: "Interlocking door system vestibule = Slave interlocking door system" for interlocking door system "Interlocking door system vestibule = Slave vestibule" for vestibule RS485 4 RS485 -A 4 RS485 -B 43 SCR 3

Automatic sliding doors Mode of operation 4 Mode of operation For sliding doors on rescue routes, the programme switch must be protected from unauthorised access e.g. by using a lockable version. The display programme switch DPS, the service terminal ST0 or GEZEconnects (mat. no. 33367) is required for setting control parameters and commissioning the door drive. Symbol Display Explanation OFF SERVICE OFF (only valid for mat. no. 554 and 5580 in combination with DCU V3.3) The drive is switched to without function for service purposes. The door leaves can be moved freely by hand. Activation and safety sensors are without function. Drive motor and locking are switched off. na LS Au Winter NIGHT The door is closed and locked. The door can only be opened while mode contact sensor authorised (KB) is active or via manual release. SHOP CLOSING (one-direction operation from the inside to the outside) The door can be activated using contact sensor inside (KI) and contact sensor authorised (KB). The safety sensors "close" (SIS) are active. When activated, the door opens up to a reduced opening width set during commissioning. AUTOMATIC with reduced opening width. Activation is possible with contact sensor inside (KI), contact sensor outside (KA) and contact sensor authorised (KB). The safety sensors "close" (SIS) are active. When activated, the door opens up to a reduced opening width set during commissioning. do Au Summer PERMANENTLY OPEN The door is completely opened. AUTOMATIC with full opening width Activation is possible with contact sensor inside (KI), contact sensor outside (KA) and contact sensor authorised (KB). The safety sensors "close" (SIS) are active. When activated, the door opens up to full opening width. 4. Mechanical programme switch The LED on the mechanical programme switch lights up after the service interval has expired or in the event of a fault. MPS, AS 500, mat. no. 36 MPS-ST, with key, AS 500, mat. no. 37 Accessories: Surface-mounted cap single, AS 500, mat. no. 0503 LED Operating modes: OFF, Na, ls, au Winter, DO, au Summer Follow installation instructions, (mat. no. 6). or Set parameters for input/terminal PE: With DPS: e to 0 for MPS With ST0: "PE-function" to "MPS" Set parameters for output/terminal PA and PA: With DPS: Set a or a to 04 for fault display MPS. With ST0: Set "PA-" or "PA-function" to "fault MPS". If the mechanical programme switch is used, it is not possible to change the operating mode using the keypad programme switch, display programme switch or the inputs Na, ls, au and DO. 33

Mode of operation Automatic sliding doors 4. Switching the operating mode using push buttons or switches In addition, it is possible to change between the operating modes Na, au, ls, DO and "OFF" using potential-free push buttons or switches. For the operating mode "OFF" the function parameter must be set for the input used. If the drive is switched to the OFF operating mode, the door opens before the drive switches off. With DPS: Set e, e or e3 to 0. PS 6 NA 7 LS 8 AU 9 DO OFF PE PE or oder PE PE or oder PE3 5 PE 5 PE PE3 With ST0: Set "PE-", "PE-" or "PE3-function" to "OFF". The control switches to the desired operating mode if the level switches from D to 4 V at the corresponding input. Operation using the keypad programme switch or display programme switch is only possible if there is no signal pending at the inputs Na, au, ls and DO. Locking the door (changing to operating mode Na) using a potential-free push button or switch is not possible for doors on rescue routes. 4.3 Keypad programme switch TPS, AS 500, flush-mounted, mat. no. 33 TPS SCT, AS 500, flush-mounted, with key push button, without profile half cylinder, mat. no. 33 70 ma RS485 4 RS485-A LEDs () for operating mode display indicate a fault code when a fault has occurred (see fault messages keypad programme switch). LED () lights up with reduced opening width. Operating modes: OFF, Na, ls, au, DO, Summer / Winter Operation of the programme switch can be blocked for unauthorised persons by using a key push button or assigning a password (see chapter 4.8). No TPS can be connected when PE-function is "MPS" (only display possible). 44 4 4 LEDs for operating mode display LED for reduced opening width 3 Additional contact 3 4 RS485-B 43 SCR KB 3 4VA KKU 0 KB Follow installation instructions, mat. no. 400. Accessories: Profile half cylinder, mat. no. 09076 Additional contact, mat. no. 04467 Surface-mounted cap single, AS 500, mat. no. 0503 Surface-mounted cap double, AS 500, mat. no. 8609 34

Automatic sliding doors Mode of operation 4.4 Display programme switch (DPS) with OFF key AS 500, DPS with OFF, flush-mounted, alpine white, mat. no. 554 AS 500, DPS with OFF and SCT, with profile half cylinder, flush-mounted, alpine white, mat. no. 5580 Operating modes: OFF, Na, ls, au, DO, Summer / Winter opening width OFF 44 4 RS485 4 RS485-A 4 RS485-B 43 SCR Follow the installation instructions 00 ma 4 A DPS cannot be connected if the PE-function is set to "MPS" (only display possible). Changing the operating with the DPS is only possible if 4 V are not applied to Na, ls, au, DO or PE or PE if PE, PE or PE3 is configured to OFF. Operation of the programme switch can be blocked for unauthorised persons by using a key push button or assigning a password (see chapter 4.8). Switching between summer/winter opening width: Press the keys simultaneously. KB 0 KB Display summer/winter (LED lights up for winter opening width) Hidden service key A maximum of one keypad programme switch can be connected to the control together with a maximum of one display programme switch. The control can be configured using DPS. See Service menu, chapter.. Accessories: Key push button SCT, single-pole, flush-mounted, AS 500 without profile half cylinder, mat. no. 7996 Profile half cylinder, mat. no. 09076 Additional contact, mat. no. 04467 Surface-mounted cap single, AS 500, mat. no. 0503 Surface-mounted cap double, AS 500, mat. no. 8609 4.5 Display programme switch (DPS) without OFF key AS 500, DPS without OFF, flush-mounted, alpine white, mat. no. 55809 Operating modes: Na, ls, au, DO, Summer/ Winter opening width Follow the installation instructions. The DPS without OFF key does not have an OFF function. For further information see display programme switch (DPS) with OFF key. Accessories: Adapter frame, mat. no. 5585, for replacement of the old version DPS (mat. no. 03940) by DPS without OFF key. 00 ma 44 4 4 RS485 4 RS485-A 4 RS485-B 43 SCR KB 0 KB Display summer/winter (LED lights up for winter opening width) Hidden service key 3 Additional contact 3 35

Mode of operation Automatic sliding doors 4.6 Display programme switch, old version (mat. no. 03940) The old version of the DPS can still be connected. Connection and function as with the display programme switch without OFF key. 4.7 Reset function (DPS with OFF key, TPS) In the OFF operating mode, the keys and can be pressed at the same time to trigger a software reset. The drive then behaves in the same way as after mains voltage switch-on and carries out initialisation. The parameter settings are not changed. The reset function is not possible with the DPS without OFF key. 4.8 Blocking or releasing operation of TPS and DPS 4.8. With additional key push button ( st possibility) With automatic standard sliding doors Press the key push button briefly to block function. With the DPS, the operation lock is signalled by the display "- -" when any key is pressed. With the TPS, the operation block is signalled by the LED for the respectively set operating mode flashing once when any key is pressed. Press the key push button again briefly for release. Operation is then permanently released. For automatic sliding doors on escape and rescue routes The key push button has to be activated permanently to unlock the operation. Operation is blocked as soon as the key push button is no longer pressed. With the DPS, the operation lock is signalled by the display "- -" when any key is pressed. With the TPS, the operation block is signalled by the LED for the respectively set operating mode flashing once when any key is pressed. 4.8. Release with password ( nd possibility) This requires previous setting of the -digit password in the drive Service menu (factory setting: no password). For release on the TPS: Enter the first digit of the password by the number of times the key is pressed, with TPS: Key DPS: Key au Enter the second digit of the password by the number of times the key is pressed, with TPS: Key DPS: Key DO After the password has been entered, operation of the programme switch has been released. Operation is blocked automatically minutes after the last key has been pressed. With the TPS, the operation block is signalled by the LED for the respectively set operating mode flashing once when any key is pressed. With the DPS, the operation lock is signalled by the display "- -" when any key is pressed. 4.8.3 Permanent release of programme switch operation For permanent release, either fit a jumper between terminals -44 of the TPS or DPS or set the value "00" (factory setting) as the password in the Service menu. 36

Automatic sliding doors Configurable outputs 5 Configurable outputs The control indicates various states via the two configurable outputs PA and PA (see Service menu). The outputs must be configured accordingly. 5. PA (gong) PA is a potential-free relay contact, switching voltage/current max. 4 V AC/DC / 0.5 A. Set parameters for the gong function: With DPS: Set a or a to 0. With ST0: Set "PA-" or "PA-function" to "Gong". The contact closes as soon as SIS or SIS is activated. PA PA 55 PAA 56 PAB 3 5. PA (fault, fan) Gong Bell transformer 3 Feeder PA is a transistor output, switching voltage/current max. 4 V DC / 0.5 A. PA PA 57 PA Set parameters for fault indication: With DPS: Set a or a to 0. With ST0: Set "PA-" or "PA-function" to "Fault closer". The output switches to D as soon as the control detects a system fault. At the same time, the corresponding fault number is displayed on the display programme switch or keypad programme switch. A relay for galvanic isolation must be installed for forwarding the fault message (e.g. to a building management system). Set parameters for the use of a fan for cooling the motor: With DPS: Set a or a to 07. With ST0: Set "PA-" or "PA-function" to "Motor fan". Motor fan for Slimdrive, mat. no. 80533 Motor fan for Powerdrive, mat. no. 3394 37

Mains connection Automatic sliding doors 6 Mains connection Transformer for Slimdrive, mat. no. 0694 Transformer for ECdrive, mat. no. 06530 Transformer for Powerdrive, mat. no. 7975 30V 50Hz L N PE BK BU /YE 3 PE DCU 3 4 AC IN BK BK L TA BK AC 4 BU /YE BU /YE N PE AC PE 5 6 Mains fuse on site, min. 4 A slow-burning Main switch (optional) 3 Transformer 4 Control 5 Cover earthing 6 Earthing connection 38

Automatic sliding doors Locking 7 Locking 7. Locking by toothed belt Locking by toothed belt Slimdrive SL, SLT, SL NT, mat. no. 4004 Locking by toothed belt Slimdrive SC, mat. no. 0575 Locking by toothed belt ECdrive, mat. no. 7766 Locking by toothed belt Powerdrive, mat. no. 4000 S S3 BK RD BK BK C NC YE LK YE LOCK 3 LCK B 4 LCK A 5 LKD 6 ULKD Shown in unlocked state. Switch S3, mat. no. 09080, can be installed optionally, switching voltage/current max. 4 V AC/DC / 0.5 A. In the locked state, switches S and S3 are activated and the contact of switch S is opened. 7. Rod locking, break axle Rod locking Slimdrive SL, SLT, mat. no. 05680 Break axle Slimdrive SF, mat. no. 07574 S S YE S3 S4 M YE YE YE LOCK 6 ULKD 5 LKD 4 LCK A 3 LCK B Shown in unlocked state. Switches S3 and S4, mat. no. 05684, can be installed optionally with break axle, switching voltage/current max. 4 V AC/DC / 0.5 A. In the locked state, switches S and S3 are activated, the contacts of switches S and S3 and the contacts of switches S and S4 are opened. The following rod lockings are used for drives with RC: -leaf SL RC, without potential-free contact mat. no. 34044 -leaf SL RC, with potential-free contact mat. no. 3605 -leaf SLC RC, with potential-free contact mat. no. 4044 -leaf, right closing SL RC, with potential-free contact mat. no. 39769 -leaf, left closing SL RC, with potential-free contact mat. no. 39770 39

Rechargeable battery Automatic sliding doors 7.3 Hook bolt Lock A Hooked locking device Lock Basis HRS, mat. no. 56679 Depending on the drive, number of leaves and direction of closing movement, the following accessories are used: Lock A Integration EC -leaf, -leaf, right, mat. no. 53658 Lock A Integration EC -leaf left, mat. no. 53660 Lock A Integration SL NT -leaf, -leaf right, mat. no. 5367 Lock A Integration SL NT -leaf left, mat. no. 5367 Set the parameters with: Parameter Value Description DPS E 0 Manual unlocking Rt 05 Lock A, hook bolt lock ST0 Door parameters \ electric locking Lock A Hook bolt lock Input signals \ PE Lock A Manual unlocking DCU PE, PE D 4V 3 4 5 4V PE PE 3 4 5 6 5 5 DCU LOCK YE YE PK 6 5 4 3 YE PK YE PK LOCK A 4V 5 4 6 BK RD M k49 7k7 Shown in "unlocked" state Rod contacts (Lock A Integration) Bolt B 3 Bolt A 4 Locked 5 Unlocked 6 Manually unlocked 8 Rechargeable battery Rechargeable battery, mat. no. 06863 4 V Voltage in charged state: 6 V (with rechargeable battery unplugged). - + RD BK AKKU UAKKU D 40

Automatic sliding doors Motor 9 Motor Motor : Motor DCU, mat. no. 05009. Motor : Only with tandem motor DCU-M, mat. no. 057. ENC OG RD BK YE ENC 7 B 6 A 5 5V 4 D 3 D Temp SHLD M + M 3 SHLD M B M A 3 M + M 3 SHLD M B M A Temperature sensor Motor 3 Motor 4

Control Automatic sliding doors 0 Control Control DCU, mat. no. 0500. Terminal bag, mat. no. 06047. AKKU ENCODER M_TEMP M AC IN Control DCU-M, mat. no. 050. Terminal bag, mat. no. 06047. DCU0 M DCU0 F F3 DCU00 F4 F5 DCU00: F 4 V EXT (.5 AT, 5x0 mm) F AC IN (6.3 AT, 5x0 mm) F3 rechargeable battery (6.3 AT, 5x0 mm) RUN Run-LED DCU0: F4 AC IN (6.3 AT, 5x0 mm) F5 rechargeable battery (6.3 AT, 5x0 mm) DCU03 3 µr DCU00 CAN DCU03 - CAN terminating resistance inactive -3 CAN terminating resistance active RUN-LED LED on: Everything OK. LED flashes slowly (0.5 Hz): Drive not taught. LED flashes quickly ( Hz): Fault. F PE PE PA PA RUN STOP PS SIS DCU03 SIO LOCK PROG PE3 KI SIO KA KB SIS RS485 4