SAMPLE. Job Name: Anywhere Water District Construction of Reservoir Suggest'd Equipment Rent Total. Suggest'd Material.

Similar documents
Engineering Service Specifications. Commercial Single-Phase Current Transformer Metering Schemes

Seismic Sensor Accessories SA, SV & ST 6000 Series

320A Single Phase URD Meter Loop Installations

ADDENDUM No. 1 Prospective Bidders

Ground Mount / Piping / Electrical Quick Reference ECS Membrane Processor: PMC and ISD

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

YOUR FULL LINE SOURCE FOR PVC ELECTRICAL PRODUCT

JACKSON ELECTRIC COOP METER LOOP CONSTRUCTION SPECIFICATIONS JUNE 2018

GSC CONDUIT FITTING SOLUTIONS PRODUCT CATALOG

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

Customer Requirements Downtown Secondary Network Service

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

SERVICE REQUIREMENTS COMMERCIAL & INDUSTRIAL CUSTOMERS

BRACKETS, MOUNTS & HARDWARE

Fertilizer Type B 2 CWT $ $ $60.00 $ $60.00 $ Sod Water 60 MGAL $60.60 $3, $30.00 $1, $30.00 $1,

P&C Flex. Non-Metallic Rigid Conduit, Fittings and Accessories. Corrugated Flexible Conduit. Applications

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Generator Fire Safety: Generator assemblies should be located outside the building.

$69, $63, $63, $62, Schedule B - PIP & C905 Pipe

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

Outdoor Power Transmission & Distribution

LIFT STATION 11 ONE-LINE DIAGRAM

MODEL EVA PARTS MANUAL Rev.1.03

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

Product Information Guide

General Cable Support Information

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

U-18. Company furnishes and installs: 10. Service lateral and connectors. 11. Conduit package, Amperes.

COMMERCIAL QUICK REFERENCE

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

Category # 1 - Overhead, Primary, & Secondary Conductors

PITNEY BOWES Sure-Feed Engineering SURE JET MODEL SJVB - TUV. Parts Manual. SJVB-TUVparts 1

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

PROJECT: : Maysak New House Construction_Weno, Chuuk State DATE : 27 June 2016 ORDER : 23 SETS (Complete with Electrical) of the below Items

Castle Model TSM-35. Heavy Duty Screw Pocket Machine. For Models with Serial Number and Above Items Included with Machine

MODEL EVA PARTS MANUAL Rev.1.05

HANGERS, STRUT, AND FITTINGS SUBMITTAL

BIDDER'S PROPOSAL (continued) CITY OF BERKELEY BID PROPOSAL ITEM NO. A: BASE BID

Aqua Green Utility Inc.

PO Box 847 Greensburg, PA Phone (724) Fax (724) /0

Bulb Depot Woodland Park NJ UNIT QTY. UNIT COST TOTAL COST. foot 300 $0.39 $ each 100 $1.45 $ each 100 $1.25 $125.00

Applications. Innovative Solutions For Wire and Cable Management

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

SURFACE TRACK (120/250V) SPECIFICATIONS

ZoneEx Modular Wiring System

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

10 Commercial, Industrial, Agricultural Services

Bid # Plumbing Supplies RESULTS

For Conduit Inspections

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Max. Operating Pressure. Inside Diameter. ft m in mm psi bar in mm

Replacement Parts List

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

7 Single Family Service

PRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

Chapter 8 Interior Wiring and Lighting

San Antonio, Texas San Antonio, Texas Well Mitigation for City of Nixon. Prepared by DYS

Bid Summary Still Creek Wastewater Improvements Phase III City Job No. 411-D November 21, 2013

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

5. Contractor Information 3M Model 2300 Series System Layout Checklist

0.6 / 1kV Afumex Flex Cable. The greater the flow of people, the better the protection should be.

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Lifeline Medical Systems

HILLS MATERIALS COMPANY UNIT COST TOTAL COST UNIT COST TOTAL COST UNIT COST $294, $294, $74, $74, $35, $35,000.

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

Steese Rd - Curb & Sidewalk Improvement

Section 02: Pre-Installation Procedures

UNDERGROUND SERVICES - SECONDARY

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

Existing 400A Circuit Breaker For B Secondary Chill Water Pump. Existing Single 2.5 Conduit. Reuse As Much As Practical

Project # & Name: # CDBG - Pugh Street Streetscape - East College Ave to East Beaver Ave & East Beaver Ave/Locust Lane Improvements

NEC, Inc West Road Houston, Texas Phone: Fax:

THE AquaBlast & RocketRide FUNSLIDES

GRANITE ENCLOSURES MODEL NO. NPS Standard Features

CONNECTING POINT COMPUTER CONTRACT PRICING SHEET EXPIRES: OCTOBER 31, 2018

M O D E L S EST- FL PARTS MANUAL Rev 1.00A

SALEM CITY POWER ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Water Inventory Items Bidder Price List

Installing a Downstream Distribution Panelboard

Maine Turnpike Authority

RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS SECTION II RESIDENTIAL UNDERGROUND AND OVERHEAD SERVICE REQUIREMENTS

ELIPS Pipe Materials Bid Summary August 29, :00am Bid Opening

Immersion Temperature Sensors

Connection 1 Connection 2 ft m in mm psi bar in mm

Overview... I2 Conduit Products Rigid Steel Conduit Elbows... I3 E.M.T. (Thinwall) Conduit Elbows 45 and I3 Galvanized Rigid Conduit Special

1' to 10' deep and 1' to 25' deep

TC-RHH/RHW-2 USE-2 Copper

Wire Mesh Safety Grips

Transcription:

Job Name: Anywhere Water District Construction of Reservoir 1500 Anywhere Water District Construction of Reservoir 1500 Electrical Contractor Sub Bid Qty #Elect Hours Unit Underground Conduit Work $60/hr Rent Total Trenching per linear foot of trench, 18 x 30 approximately 460 L1 32.2 LF 3417.8 1932 0 5349.8 Mandrel Wire Brush and Swab Conduits (use vacuum with pull string) 1 L2 4 Ea 0 240 0 240 Slurry, 2 sack red oxide dyed 32 CY 1.28 CY 3136 76.8 0 3212.8 Shoring/support for conduit in trenches with rods, wire and wood Total all L2 16 Ea 200 960 0 1160 Schedule 40 PVC conduit, 10' lengths with coupling 10.9 L1 34.88 CLF 618.03 2092.8 0 2710.83 PVC coated steel 90 degree elbows 32 L1 3.2 Ea 560 192 0 752 PVC coated steel conduit, 40 mil coating (for transversion to above ground) 1.5 L1 8.25 CLF 601.5 495 0 1096.5

Plastic Duct Spacers 4" with 1.5" separation 250 L1 12.5 Ea 630 750 0 1380 PVC coated female conduit unions 32 L1 3.2 Ea 1107.2 192 0 1299.2 Schedule 40 PVC conduit, 10' lengths with coupling 1" 5 L1 16.5 CLF 426.5 990 0 1416.5 PVC coated steel 90 degree elbows 1" 28 L1 4.2 Ea 341.6 252 0 593.6 PVC coated steel conduit, 40 mil coating (for transversion to above ground) 1" 1.4 L1 9.8 CLF 728 588 0 1316 Plastic duct spacers 4" with 1.5" separation 130 L1 6.5 Ea 327.6 390 0 717.6 PVC coated female conduit unions 1" 28 L1 4.2 Ea 1850.8 252 0 2102.8 Schedule 40 PVC conduit, 10' lengths with coupling 2" 8.9 L1 31.15 CLF 1619.8 1869 0 3488.8 PVC coated steel 90 degree elbows (24 radius) 2" 14 L1 3.5 Ea 504 210 0 714

PVC coated steel conduit, 40 mil coating (for transversion to above ground) 2" 0.7 L1 9.1 CLF 728 546 0 1274 Plastic duct spacers 2" with 1.5" separation 195 L1 9.75 Ea 591.4 585 0 1076.4 PVC coated female conduit unions 2" 14 L1 3.5 Ea 2394 210 0 2604 Core Drill and Seal Conduit Holes in Vaults 4 4.5" L2 2 Ea 48 120 168 336 **Subtotal: Underground Conduit Work 215.71 19830.23 12942.6 168 32840.83 Mount Enclosures PB 1 Hoffman A48H36CLP Enclosure (48x36x10) NEMA 4 1 L2 2 Ea 1485 120 0 1605 Drill or Punch Holes in panel 1 8 L1 0.8 Ea 0 48 0 48 Drill or Punch Holes in panel 2 2 L1 0.3 Ea 0 18 0 18 MRTU 1 Hoffman A48H36CLP Enclosure (48x36x10) NEMA 4 1 L2 2 Ea 1485 120 0 1605 Drill or Punch Holes in panel 1 4 L1 0.4 Ea 0 24 0 24 Drill or Punch Holes in Distribution Panel 2B 3" L1 0.45 Ea 0 27 0 27

1 L1 2 Ea 1083 120 0 1203 Drill or Punch Holes in Panel 2B 2 3/4" L1 0.2 Ea 0 12 0 12 Drill or Punch Holes in Panel 1 3 L1 0.3 Ea 0 18 0 18 TPS1 (Transducer Pressure SWitch) Hoffman A36H30CLP Enclosure (36x30x10) NEMA 4 1 L1 2 Ea 1083 120 0 1203 Drill or Punch Holes in panel 1 2 1" L1 0.2 Ea 0 12 0 12 TPS2 (Transducer Pressure SWitch) Hoffman A36H30CLP Enclosure (36x30x10) NEMA 4 1 L1 2 Ea 1083 120 0 1203 Drill or Punch Holes in panel 1 2 1.5" L1 0.2 Ea 0 12 0 12 Seismic Sensor Control Box provided by sensor manufacturer 1 L1 1 Ea 0 60 0 60 Rigid steel conduit clamps with bolts 3/4 SS304 10 L1 0.6 Ea 9.3 36 0 45.3 Rigid steel conduit clamps with bolts 1 SS304 50 L1 4 Ea 62.5 240 0 302.5 Rigid steel conduit clamps with bolts 2 SS304 5 L1 0.5 Ea 16.85 30 0 46.85 Channel spring nuts 304 SS 3/8 16 13/16 strut 50 L1 3 Ea 61 180 0 241 12 gauge steel channel with 9/16 holes, 1 7/8 oc 1 5/8 x 1 5/8 galvanized 0.5 L1 3 CLF 137.5 180 0 317.5

14 gauge steel channel with 9/16 holes, 1 7/8 oc 1 5/8 x 1 5/8 galvanized 0.1 L1 0.6 CLF 36.6 36 0 72.6 Weld 1 x 6 unistrut horizontal support mounts 24 feet up side of tank and 5 feet on center and approx 26 feet towards center of top of tank for conduit. Manlift and welding rental 10 L1 0.1 Ea 0.5 6 440 446.5 **Subtotal: Mount Enclosures 25.65 6543.25 1539 440 8522.25 Raceway Stub Ups to Enclosures Standard wall galvanized rigid steel conduit 1 L1 4.5 CLF 544 270 0 814 Standard wall galvanized rigid steel conduit 1 inch 1.7 L1 8.5 CLF 1331.1 510 0 1841.1 Standard wall galvanized rigid steel conduit 0.4 L1 4 CLF 648 240 0 888 Galvanized cast metal Types LB, LL or LR conduit bodies Form 8 22 L1 3.3 Ea 188.76 198 0 386.76 Galvanized cast metal Types LB, LL or LR conduit bodies Form 8 1 inch 10 L1 2 Ea 128 120 0 248 Galvanized cast metal Types LB, LL or LR conduit bodies Form 8 10 L1 3 Ea 482 180 0 662

Insulated malleable bushed nipples 32 L1 1.92 Ea 32 115.2 0 147.2 Insulated malleable bushed nipples 1 inch 28 L1 2.24 Ea 52.64 134.4 0 187.04 Insulated malleable bushed nipples 14 L1 2.1 Ea 69.44 126 0 195.44 Type UA liquid tight flex conduit 0.3 L1 1.35 CLF 70.2 81 0 151.2 Insulated malleable liquid tight flex connectors 24 L1 2.4 Ea 151.68 144 0 295.68 **Subtotal: Raceway Stub Ups to Enclosures 35.31 3697.82 2118.6 0 5816.42 Wire # 18 Rd Solid 0.06 L2 0.3 KLF 4.25 18 0 22.25 # 18 Rd/WH Stripe 0.07 L2 0.35 KLF 4.96 21 0 25.96 # 18 BN Solid 0.05 L2 0.25 KLF 3.54 15 0 18.54 # 18 BN/WH Stripe 0.08 L2 0.4 KLF 5.66 24 0 29.66

# 18 OR Solid 0.04 L2 0.2 KLF 2.83 12 0 14.83 # 18 OR/WH Stripe 0.07 L2 0.35 KLF 4.96 21 0 25.96 # 18 Gn/WH Stripe 0.19 L2 0.95 KLF 13.45 57 0 70.45 # 18 OY/WH Stripe 0.19 L2 0.95 KLF 13.45 57 0 70.45 # 18 YL/WH Stripe 0.04 L2 0.2 KLF 2.83 12 0 14.83 # 18 BE/WH Stripe 0.04 L2 0.2 KLF 2.83 12 0 14.83 # 18 BK/WH Stripe 0.04 L2 0.2 KLF 2.83 12 0 14.83 # 18 BN/WH Stripe 0.06 L2 0.3 KLF 4.25 18 0 22.25 # 18 VT/WH Stripe 0.04 L2 0.2 KLF 2.83 12 0 14.83 # 18 BE 0.01 L2 0.05 KLF 0.71 3 0 3.71 # 18 BN 0.03 L2 0.15 KLF 2.12 9 0 11.12

18 AWG stranded comm. cable, individually shielded twisted pair, 80 degree, PVC jacket, 300 v.2 pairs 0.24 L2 1.44 KLF 340.8 86.4 0 427.2 Type THHN 600 volt stranded copper building wire # 14 OR 0.21 L2 1.26 KLF 15.29 75.6 0 90.89 Type THHN 600 volt stranded copper building wire # 14 BE 0.21 L2 1.26 KLF 15.29 75.6 0 90.89 Pulling String 200LB Nylon 1500 L2 1.5 L.F. 240 90 0 330 Type THHN 600 volt stranded copper building wire # 12 0.44 L2 3.08 KLF 46.2 184.8 0 231 Soft drawn stranded copper ground wire #12 0.28 L1 1.19 KLF 39.76 71.4 0 111.16 Type THHN 600 volt stranded copper building wire # 10 0.06 L2 0.48 KLF 9.48 28.8 0 38.28 RGS Cable 0.18 L2 1.755 KLF 306 105.3 0 411.3 **Subtotal: Wire 17.015 1084.32 1020.9 0 2105.22 Mount Intrusion Switch and Tank High Level Alarm, connect light and camera GEMS LS 3 Float Switch 1 L1 1.5 Ea 40 90 0 130 Omron D4A 1101N or equal limit switch and rotating arm 1 L1 1.5 Ea 125 90 0 215

PVC Coated RGS nipples 1/2" x 2 1 L1 0.05 Ea 31.23 3 0 34.23 PVC coated Type T conduit bodies T 18 1/2" 1 L1 0.25 Ea 43.4 15 0 58.4 PVC coated steel conduit, 40 mil coating 1 L1 4.5 CLF 346 270 0 616 PVC coated male conduit unions 1" L1 0.1 Ea 35.2 6 0 41.2 Schedule 40 PVC conduit, 10' lengths with coupling 1/2 custom cut to mount float 0.1 L1 0.31 CLF 4.29 18.6 0 22.89 Schedule 40 PVC couplings 1 L1 0.02 Ea 0.19 1.2 0 1.39 Insulated thread bushing 1 L1 0.1 Ea 6.34 6 0 12.34 Steel or malleable reducing bushings 1/4 to 1/8th 1 L1 0.05 Ea 0.93 3 0 3.93 Hookup Light Pole and Camera 1 L1 1 Ea 0 60 0 60 **Subtotal: Mount Intrusion Switch, High Level Alarm... 9.38 632.58 562.8 0 1195.38 Testing 1 L2 8 Ea 0 480 0 480

Total Manhours,,, and : 311.07 31788.2 18663.9 608 50960.1 Subtotal: 50960.1 Estimate Total: 50960.1 9.75% Tax on s: 3089.6 9.75% Tax on : 59.28 Grand Total: 54108.98