MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

Similar documents
Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

System pro M compact Miniature Circuit Br eakers Description Features

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature circuit breakers

Miniature Circuit Breakers

Control Circuit Protection

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Bulletin 1489 Circuit Breakers. Selection Guide

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Miniature Circuit Breaker UL / CSA Range

Jtec 10kA Miniature Circuit Breaker

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers

System pro M compact Modular DIN rail components E220 - E270 Series

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

and other modular devices for low voltage installation

1489-M Circuit Breakers

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

UMBW-UL489 and UL1077 Listed

Selection Guide. Control Circuit and Load Protection

Product Line Overview. The Most Logically Designed Contact Assembly

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

smissline Description

1492-CB 1492-GH 1492-GS

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Miniature circuit breaker Application guide

Miniature Circuit Breaker

Tmax Molded Case Circuit Breakers

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

ELFA E90S MINI BREAKERS

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

Fuse holders and fuses

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

PD-Series Ground Fault Circuit Protection

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

Phone: Fax: Web: -

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Protection Equipment

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Technical data. Miniature Circuit Breakers. System pro M. System pro M

MS General Information Extended Product Type: MS

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

XT IEC Power Control Manual Motor Protectors

Circuit Protection. Circiut Protection

Short form catalogue. Motor protection & control

3 - Protection components Motor circuit-breakers

Low Voltage A GE Power Controls Company. General catalogue

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Motor Circuit Breakers C4

Protection Equipment. 5/2 Introduction

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Manual Motor Starters. Meta-MEC

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Miniature Circuit-Breakers (MCBs)

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

TMC 91H is now TMC 60 C Series

Thermal-Magnetic Circuit Breaker 201/-WA

Miniature circuit-breaker (MCB) SH200M Series

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

UL/CSA Non-fused Disconnect Switches

BETA Low-Voltage Circuit Protection

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Application Description

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Low-Peak 600V Class RK1

Electronic Circuit Breaker ESS20-0..

4 - Miniature controls

Proline Panelboard and breakers

Jtec 489 UL489 Branch Circuit Breaker

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

MINIATURE CIRCUIT BREAKER

Circuit Protectors CP31F, 32F, 33F

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF series contactors (9 2650)

BETA Switching Switches and Light Indicators

F-Series. Circuit Breaker

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Transcription:

Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for use by Underwriters Laboratories Standard UL077 for supplementary circuit protectors in systems rated 40VAC, 480VAC and 600VAC. Devices are certified per CSA C.. MCBs are approved per IEC-898 and VDE 064, and certified under IEC-947 and VDE 0660 standards for use in systems rated 4VAC or 690VAC (S00 series). MCBs can be applied to 6 /3Hz 400Hz and DC power systems. Special direct current version MCBs include a permanent magnet for DC fault current interruption. These "UC" versions are rated 0/00VDC under UL077/CSA. No. 3. Continuous current ratings are as low as 0. amperes and up to amperes maximum. MCBs are of compact size and can be quickly mounted on standard 3mm DIN rail or can be front mounted by use of a front mounting kit. MCBs include line and load side terminals for conductors from 8 through 4AWG (0.7 mm ) for 40 amperes; up to AWG for 0 and 63 amperes. MCBs can also be connected via busbar conductors which can be either upper or lower mounted for top feed or bottom feed. Dual function terminals allow busbars to be connected with main incoming line conductors without separate lugs. Accessories Auxiliary devices can be added to S60, S70 and S80 series MCBs: Shunt trips Auxiliary contacts Trip contacts Aux/trip contacts Undervoltage release Accessory device modules can be field mounted to all above listed ABB MCBs. Auxiliary contacts are also available for the S00 series MCB. Applications MCBs can be used for equipment protection, in commercial appliances, protection of control circuits against overcurrent faults, computer equipment and other computer peripheral devices. UL 077 MCBs are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided or not required. MCBs and accessories are recognized under UL File E766. CSA C. MCBs and accessories are certified under CSA C. No. 3 per File LR98793. Tripping characteristics Time-current curves ABB miniature circuit breakers are available with different trip characteristics, allowing for maximum system protection. B Characteristic Available with the S60 series has rated currents of 6 through 63 amperes in 0 steps. The "B" timecurrent curve is designed primarily for use in cable protection applications. Instantaneous tripping occurs between approximately 3 to times rated current in 0/ 60Hz systems. This quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring. C Characteristic Available in the S60 series with rated currents up though 63 amperes and the S90 series with rated currents of 80, 00 and amperes. The "C" time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between and 0 times rated current in 0/60 Hz systems. The "C" characteristic is also available in other S Series MCBs. D Characteristic The new magnetic trip action has an instantaneous trip point of approximately times the breaker rating. Thus, the S60-D can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. The 60-D is also suitable for any application where a high instantaneous trip point is desired. K Characteristic The "K" time-current characteristic considers high magnetic start-up currents from motors, transformers and other equipment. Instantaneous tripping occurs between 8 and times rated current in 0/60Hz systems. The "K" characteristic is available up through 63 amperes. The "K" curve offers the best protection for the broadest range of electrical systems. The higher magnetic trip settings maximizes protection while allowing for higher in-rush currents during system start-up. Z Characteristic Also available up through 63 amperes, the "Z" characteristic offers instantaneous tripping between and 3 times rated current in 0/ 60Hz systems. This trip characteristic is available in the S80 series with both the 480VAC and 0/00VDC ratings. Many applications require a very low short circuit trip settings in order to protect semiconductor or other sensitive devices and the "Z" trip characteristic may provide maximum protection and service in these applications. ABB Control Inc.. AC 600 3/00

Gen. info. General information Interruption ratings Trip characteristics overview Interruption ratings Trip characteristics overview Voltage Rated interrupting Rated MCB capacity current type Comment 0 VAC 0kA 0. - 63A S60-B,C,D Single pole 0. - 63A S70-K Single pole 0. - 40A S80-K, Z Single pole 8kA 3-63A S00-B,C,D 6-4A S00-K 30kA 6 - A S00-B,C,D 0. - A S00-K 40 VAC 6kA 0. - 63A S60-B,C,D Single pole 0. - 63A S70-K Single pole 0-63A S80-K, Z Single pole 0kA 0. - 63A S60-B,C,D Multi pole 0. - 63A S70-K Multi pole 0. - 40A S80-K,Z Single pole 8kA 3-63A S00-B,C,D 6-4A S00-K 30kA 6 - A S00-B,C,D 0. - A S00-K 77 VAC 6kA 0. - 63A S60-B,C,D Single pole 0. - 63A S70-K Single pole 0-63A S80-K,Z Single pole 0kA 0. - 40A S80-K,Z Single pole 77/480 VAC 6kA 0. - 63A S60-B,C,D Multi pole 0. - 63A S70-K Multi pole 40-63A S80-K,Z Multi pole 0kA 0. - 3A S80-K,Z Multi pole 60 VDC 0kA 0. - 63A S60-B,C,D Single pole 0. - 63A S70-K Single pole VDC 0kA 0. - 63A S60-B,C,D Multi pole 0. - 63A S70-K Multi pole 0. - 63A S80UC-K,Z Single pole 0 VDC 4.kA 0. - 63A S80UC-K,Z Single pole 00 VDC 4.kA 0. - 63A S80UC-K,Z Multi pole Curve Magnetic characteristic Thermal characteristic Series B 3 - X.X S60, S00 C - 0X.X S60, S90, S00 D 0-0X.X S60, S00 K 8 - X.0X S70,S80, S00 Z - 3X.0X S80 All values are relative to MCB's ampere rating.. ABB Control Inc. AC 600 3/00

General information Tripping curves Gen. info. 0,000 000 B 0,000 000 C 0,000 000 D 000 00 000 00 000 00 00 0 00 0 00 0 0 0 0 seconds 0. 0. 0.0 AC DC seconds 0. 0. 0.0 AC DC seconds 0. 0. 0.0 AC DC 0.0 0.0 0.0 0,000 000 3 7 0 0 30 multiple of rated current K 0,000 000 3 0 8 0 30 multiple of rated current UC-K 3 0 0 30 multiple of rated current 000 00 000 00 00 0 00 0 0 0 seconds 0. 0. 0.0 AC DC seconds 0. 0. 0.0 DC 0.0 0.0 3 8 0 0 30 multiple of rated current 3 0 0 30 multiple of rated current 0,000 000 Z 0,000 000 UC-Z 000 00 000 00 00 0 00 0 0 0 seconds 0. 0. 0.0 AC DC seconds 0. 0. 0.0 DC 0.0 0.0 3 0 0 30 multiple of rated current 3 0 0 30 multiple of rated current ABB Control Inc..3 AC 600 3/00

Gen. info. General information Construction details (S80 shown) Electro-magnetic protection Thermal protection-bimetal Tripping lever Upper terminal Operating mechanism Operator Trip indicator Space for identification marker Arc chamber Fixed contact Moving contact DIN rail holder Lower terminal.4 ABB Control Inc. AC 600 3/00

Miniature Circuit Breakers S60, S70, S80, S90 Description The S Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard UL 077 as supplemental protective devices. The S devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Current limiting Fast breaking time (. 3. msec) Unique bus connection system Wide range of accessories Available with variable depth handle mechanism Optional Z curve for SCR protection CE certified and marked DIN rail or front plated mounting Finger safe terminals Multi-function terminals Suitable for reverse feed UL 077 and CSA. 77/480VAC and 00VDC versions ABB Control Inc.. AC 600 3/00

S60 B S60 77/480 VAC B UL 077 CSA C. No. 3 VDE 064 IEC-898 Cable protection S6-B6 S6-B6 S6-B6NA Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 6 S6-B6 $ 36 0 S6-B0 36 3 S6-B3 36 6 S6-B6 36 0 S6-B0 38 S6-B 38 A 0 4. 3 S6-B3 40 40 S6-B40 4 0 S6-B0 48 63 S6-B63 6 6 S6-B6NA 6 0 S6-B0NA 6 3 S6-B3NA 6 6 S6-B6NA 6 0 S6-B0NA 68 S6-BNA 7 A 9.0 3 S6-B3NA 74 40 S6-B40NA 76 0 S6-B0NA 90 63 S6-B63NA 0 6 S6-B6 78 0 S6-B0 78 3 S6-B3 78 6 S6-B6 78 0 S6-B0 86 S6-B 88 A 9.0 3 S6-B3 94 40 S6-B40 98 0 S6-B0 63 S6-B63 8 Sugg. Rated Catalog List Delivery Wgt. oz. current number price class order ( pc.) qty 6 S63-B6 $ 8 0 S63-B0 8 3 S63-B3 8 6 S63-B6 8 0 S63-B0 30 S63-B 3 A 3 3. 3 S63-B3 4 40 S63-B40 48 0 S63-B0 70 63 S63-B63 94 6 S63-B6NA 4 0 S63-B0NA 4 3 S63-B3NA 4 6 S63-B6NA 4 0 S63-B0NA 6 S63-BNA 68 A 8.0 3 S63-B3NA 76 40 S63-B40NA 84 0 S63-B0NA 63 S63-B63NA 40 6 S64-B6 6 0 S64-B0 6 3 S64-B3 6 6 S64-B6 6 0 S64-B0 7 S64-B 76 B 8.0 3 S64-B3 88 40 S64-B40 96 0 S64-B0 4 63 S64-B63 6 S63-B6 Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery S64-B6 S63-B6NA 0,000 000 B 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 7 0 0 30 multiple of rated current.6 Discount schedule CBB ABB Control Inc. AC 600 3/00

S60 77/480 VAC S60 C C UL 077 CSA C. - NO. 3 VDE 064 IEC-898 Cable & equipment protection 0,000 000 000 00 00 0 0 S6-C S6-C S63-C S64-C C Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 0. S6-C0. $ 4 S6-C 4.6 S6-C.6 4 S6-C 4 3 S6-C3 4 4 S6-C4 4 6 S6-C6 4 8 S6-C8 4 0 S6-C0 4 A 0 4. 3 S6-C3 4 6 S6-C6 4 0 S6-C0 4 S6-C 46 3 S6-C3 48 40 S6-C40 0 S6-C0 60 63 S6-C63 68 0. S6-C0.NA 84 S6-CNA 84.6 S6-C.6NA 84 S6-CNA 84 3 S6-C3NA 84 4 S6-C4NA 84 6 S6-C6NA 84 8 S6-C8NA 84 0 S6-C0NA 84 B 9.0 3 S6-C3NA 84 6 S6-C6NA 84 0 S6-C0NA 84 S6-CNA 88 3 S6-C3NA 90 40 S6-C40NA 96 0 S6-C0NA 63 S6-C63NA 30 0. S6-C0. 96 S6-C 96.6 S6-C.6 96 S6-C 96 3 S6-C3 96 4 S6-C4 96 6 S6-C6 96 8 S6-C8 96 0 S6-C0 96 A 9.0 3 S6-C3 96 6 S6-C6 96 0 S6-C0 96 S6-C 06 3 S6-C3 06 40 S6-C40 6 0 S6-C0 36 63 S6-C63 Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 0. S63-C0. $ 38 S63-C 38.6 S63-C.6 38 S63-C 38 3 S63-C3 38 4 S63-C4 38 6 S63-C6 38 8 S63-C8 38 0 S63-C0 38 3 S63-C3 38 A 3 3. 6 S63-C6 38 0 S63-C0 38 S63-C 6 3 S63-C3 8 40 S63-C40 74 0 S63-C0 00 60 S63-CS60 8 63 S63-C63 8 0. S63-C0.NA 00 S63-CNA 00.6 S63-C.6NA 00 S63-CNA 00 3 S63-C3NA 00 4 S63-C4NA 00 6 S63-C6NA 00 8 S63-C8NA 00 0 S63-C0NA 00 B 8.0 3 S63-C3NA 00 6 S63-C6NA 00 0 S63-C0NA 00 S63-CNA 06 3 S63-C3NA 40 S63-C40NA 4 0 S63-C0NA 64 63 S63-C63NA 304 0. S64-C0. 8 S64-C 8.6 S64-C.6 8 S64-C 8 3 S64-C3 8 4 S64-C4 8 6 S64-C6 8 8 S64-C8 8 0 S64-C0 8 B 8.0 3 S64-C3 8 6 S64-C6 8 0 S64-C0 8 S64-C 34 3 S64-C3 38 40 S64-C40 60 0 S64-C0 300 63 S64-C63 338 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery seconds 0. 0. 0.0 AC DC 0.0 3 0 8 0 30 multiple of rated current ABB Control Inc. Discount schedule CB.7 AC 600 3/00

S60 D S60 77/480 VAC D UL 077 CSA C. VDE 064 IEC-898 Cable & equipment protection S6-D0. S6-D Sugg. Rated Catalog List Delivery order current number price class qty Wgt. oz. ( pc.) 0. S6-D0. $ 4 S6-D 4.6 S6-D.6 4 S6-D 4 3 S6-D3 4 4 S6-D4 4 6 S6-D6 4 8 S6-D8 4 0 S6-D0 4 A 0 4. 3 S6-D3 4 6 S6-D6 4 0 S6-D0 4 S6-D 46 3 S6-D3 48 40 S6-D40 0 S6-D0 60 63 S6-D63 68 0. S6-D0. 96 S6-D 96.6 S6-D.6 96 S6-D 96 3 S6-D3 96 4 S6-D4 96 6 S6-D6 96 8 S6-D8 96 0 S6-D0 96 A 9.0 3 S6-D3 96 6 S6-D6 96 0 S6-D0 96 S6-D 06 3 S6-D3 06 40 S6-D40 6 0 S6-D0 36 63 S6-D63 Sugg. Rated Catalog List Delivery order current number price class qty Wgt. oz. ( pc.) 0. S63-D0. $ 38 S63-D 38.6 S63-D.6 38 S63-D 38 3 S63-D3 38 4 S63-D4 38 6 S63-D6 38 8 S63-D8 38 A 3 3. 0 S63-D0 38 3 S63-D3 38 6 S63-D6 38 0 S63-D0 38 S63-D 6 3 S63-D3 8 40 S63-D40 74 0 S63-D0 00 63 S63-D63 8 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery S63-D63 Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. 0,000 000 D 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 0 0 30 multiple of rated current.8 Discount schedule CB ABB Control Inc. AC 600 3/00

S70 77/480 VAC S70 K K UL 077 CSA C. - NO. 3 VDE 064 IEC-898 Cable & equipment protection seconds 0,000 000 000 00 00 0 0 0. 0. 0.0 S7-K0 S7-K S7-KNA S73-K0 S73-K0 S74-K0NA K AC DC Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 0. S7-K0. $ 4 S7-K 4.6 S7-K.6 4 S7-K 4 3 S7-K3 4 4 S7-K4 4 S7-KS 4 6 S7-K6 4 8 S7-K8 4 0 S7-K0 4 3 S7-K3 4 A 0 4. S7-KS 4 6 S7-K6 4 0 S7-K0 4 S7-K 46 30 S7-KS30 48 3 S7-K3 48 40 S7-K40 0 S7-K0 60 60 S7-KS60 68 63 S7-K63 68 0. S7-K0.NA 84 S7-KNA 84.6 S7-K.6NA 84 S7-KNA 84 3 S7-K3NA 84 4 S7-K4NA 84 6 S7-K6NA 84 8 S7-K8NA 84 0 S7-K0NA 84 B 9.0 3 S7-K3NA 84 6 S7-K6NA 84 0 S7-K0NA 84 S7-KNA 88 3 S7-K3NA 90 40 S7-K40NA 96 0 S7-K0NA 63 S7-K63NA 30 0. S7-K0. 96 S7-K 96.6 S7-K.6 96 S7-K 96 3 S7-K3 96 4 S7-K4 96 S7-KS 96 6 S7-K6 96 8 S7-K8 96 0 S7-K0 96 A 9.0 3 S7-K3 96 S7-KS 96 6 S7-K6 96 0 S7-K0 96 S7-K 06 30 S7-KS30 06 3 S7-K3 06 40 S7-K40 6 0 S7-K0 36 60 S7-KS60 63 S7-K63 Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S73-K0. $ 38 S73-K 38.6 S73-K.6 38 S73-K 38 3 S73-K3 38 4 S73-K4 38 S73-KS 38 6 S73-K6 38 8 S73-K8 38 0 S73-K0 38 3 S73-K3 38 A 3 3. S73-KS 38 6 S73-K6 38 0 S73-K0 38 S73-K 6 30 S73-KS30 8 3 S73-K3 8 40 S73-K40 74 0 S73-K0 00 60 S73-KS60 8 63 S73-K63 8 0. S73-K0.NA 00 S73-KNA 00.6 S73-K.6NA 00 S73-KNA 00 3 S73-K3NA 00 4 S73-K4NA 00 6 S73-K6NA 00 8 S73-K8NA 00 0 S73-K0NA 00 B 8.0 3 S73-K3NA 00 6 S73-K6NA 00 0 S73-K0NA 00 S73-KNA 06 3 S73-K3NA 40 S73-K40NA 4 0 S73-K0NA 64 63 S73-K63NA 304 0. S74-K0. 8 S74-K 8.6 S74-K.6 8 S74-K 8 3 S74-K3 8 4 S74-K4 8 6 S74-K6 8 8 S74-K8 8 B 8.0 0 S74-K0 8 3 S74-K3 8 6 S74-K6 8 0 S74-K0 8 S74-K 34 3 S74-K3 38 40 S74-K40 60 0 S74-K0 300 63 S74-K63 338 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery 0.0 3 8 0 0 30 multiple of rated current ABB Control Inc. Discount schedule CB.9 AC 600 3/00

S80 K S80 77/480 VAC K UL 077 CSA C. - NO. 3 VDE 0660 Cable & equipment protection S8-K6 S8-K S83-K63 Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S8-K0. $ 4 0.3 S8-K0.3 4 0. S8-K0. 4 0.7 S8-K0.7 4 S8-K 4.6 S8-K.6 4 S8-K 4 3 S8-K3 4 4 S8-K4 4 6 S8-K6 4 8 S8-K8 4 A 0 4.6 0 S8-K0 4 3 S8-K3 4 6 S8-K6 4 0 S8-K0 4 S8-K 6 3 S8-K3 8 40 S8-K40 64 0 S8-K0 70 63 S8-K63 80 0. S8-K0. 8 0.3 S8-K0.3 8 0. S8-K0. 8 0.7 S8-K0.7 8 S8-K 8.6 S8-K.6 8 S8-K 8 3 S8-K3 8 4 S8-K4 8 6 S8-K6 8 A 9. 8 S8-K8 8 0 S8-K0 8 3 S8-K3 8 6 S8-K6 8 0 S8-K0 8 S8-K 30 3 S8-K3 34 40 S8-K40 34 0 S8-K0 6 63 S8-K63 8 Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S83-K0. $ 94 0.3 S83-K0.3 94 0. S83-K0. 94 0.7 S83-K0.7 94 S83-K 94.6 S83-K.6 94 S83-K 94 3 S83-K3 94 4 S83-K4 94 6 S83-K6 94 A 3 3.9 8 S83-K8 94 0 S83-K0 94 3 S83-K3 94 6 S83-K6 94 0 S83-K0 94 S83-K 96 3 S83-K3 00 40 S83-K40 4 0 S83-K0 46 63 S83-K63 80 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. 0,000 000 K 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 8 0 0 30 multiple of rated current.0 Discount schedule CB7 ABB Control Inc. AC 600 3/00

S80 (W) for use with ring tongue terminal connectors 77/480 VAC S80(W) K K UL 077 CSA C. - NO. 3 VDE 0660 Cable & equipment protection S8-K6W S8-KW S83-K63W Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S8-K0.W $ 4 0.3 S8-K0.3W 4 0. S8-K0.W 4 0.7 S8-K0.7W 4 S8-KW 4.6 S8-K.6W 4 S8-KW 4 3 S8-K3W 4 4 S8-K4W 4 6 S8-K6W 4 8 S8-K8W 4 A 0 4.6 0 S8-K0W 4 3 S8-K3W 4 6 S8-K6W 4 0 S8-K0W 4 S8-KW 6 3 S8-K3W 8 40 S8-K40W 64 0 S8-K0W 70 63 S8-K63W 80 0. S8-K0.W 8 0.3 S8-K0.3W 8 0. S8-K0.W 8 0.7 S8-K0.7W 8 S8-KW 8.6 S8-K.6W 8 S8-KW 8 3 S8-K3W 8 4 S8-K4W 8 6 S8-K6W 8 A 9. 8 S8-K8W 8 0 S8-K0W 8 3 S8-K3W 8 6 S8-K6W 8 0 S8-K0W 8 S8-KW 30 3 S8-K3W 34 40 S8-K40W 34 0 S8-K0W 6 63 S8-K63W 8 Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S83-K0.W $ 94 0.3 S83-K0.3W 94 0. S83-K0.W 94 0.7 S83-K0.7W 94 S83-KW 94.6 S83-K.6W 94 S83-KW 94 3 S83-K3W 94 4 S83-K4W 94 6 S83-K6W 94 A 3 3.9 8 S83-K8W 94 0 S83-K0W 94 3 S83-K3W 94 6 S83-K6W 94 0 S83-K0W 94 S83-KW 96 3 S83-K3W 00 40 S83-K40W 4 0 S83-K0W 46 63 S83-K63W 80 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery Screws (must be ordered separately!) Item PKG of 0 screws Catalog List number price S-SCR No charge 0,000 000 K 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 8 0 0 30 multiple of rated current ➀ For use with ring tongue or cable terminals only. Cannot be used with busbar system. No charge when ordered with the S80(W). ABB Control Inc. Discount schedule CB7. AC 600 3/00

S80(UC) K S80UC 00 VDC K UL 077 VDE 0660 CSA. No. 3 Cable and Equipment Protection S8UC-K S8UC-K8 S83UC-K6 Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 0. S8UC-K0. $ 04 0.3 S8UC-K0.3 04 0. S8UC-K0. 04 0.7 S8UC-K0.7 04 S8UC-K 04.6 S8UC-K.6 04 S8UC-K 04 3 S8UC-K3 04 4 S8UC-K4 04 6 S8UC-K6 04 B 0 4.6 8 S8UC-K8 04 0 S8UC-K0 04 6 S8UC-K6 04 0 S8UC-K0 04 S8UC-K 08 3 S8UC-K3 0 40 S8UC-K40 6 0 S8UC-K0 36 63 S8UC-K63 0. S8UC-K0. 4 0.3 S8UC-K0.3 4 0. S8UC-K0. 4 0.7 S8UC-K0.7 4 S8UC-K 4.6 S8UC-K.6 4 S8UC-K 4 3 S8UC-K3 4 4 S8UC-K4 4 B 9. 6 S8UC-K6 4 8 S8UC-K8 4 0 S8UC-K0 4 6 S8UC-K6 4 0 S8UC-K0 4 S8UC-K 48 3 S8UC-K3 6 40 S8UC-K40 66 0 S8UC-K0 3 63 S8UC-K63 348 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 0. S83UC-K0. $ 370 0.3 S83UC-K0.3 370 0. S83UC-K0. 370 0.7 S83UC-K0.7 370 S83UC-K 370.6 S83UC-K.6 370 S83UC-K 370 3 S83UC-K3 370 4 S83UC-K4 370 6 S83UC-K6 370 B 3 3.9 8 S83UC-K8 370 0 S83UC-K0 370 6 S83UC-K6 370 0 S83UC-K0 370 S83UC-K 38 3 S83UC-K3 408 40 S83UC-K40 448 0 S83UC-K0 47 63 S83UC-K63 34 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery Direct current applications The S80UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown below. Maximum voltage between leads 0VDC 00VDC 0,000 000 UC-K Single Pole S8UC L- L+ Two Pole S8UC L- L+ 000 00 00 0 0 - + - + 3+ 4- seconds 0. 0. 0.0 DC 0.0 3 0 0 30 multiple of rated current LOAD - + LOAD - + Termination points are marked on all UC type MCBs, points one () and four (4) are negative and points two () and three (3) are positive. Four pole breakers are also available for voltage reversal applications.. Discount schedule CB7 ABB Control Inc. AC 600 3/00

S80 & S80UC 77/480VAC & 00VDC S80 Z Z UL 077 VDE 0660 CSA. No. 3 Fast trip characteristic S8-Z6 S8-Z3 S83-Z3 480 VAC Class 00 VDC Class Sugg. Rated Catalog List Delivery Wgt. oz. current number price class order ( pc.) qty 0. S8-Z0. $ 70 S8-Z 70.6 S8-Z.6 70 S8-Z 70 3 S8-Z3 70 4 S8-Z4 70 6 S8-Z6 70 8 S8-Z8 70 B 0 4. 0 S8-Z0 70 6 S8-Z6 70 0 S8-Z0 70 S8-Z 70 3 S8-Z3 74 40 S8-Z40 78 0 S8-Z0 88 63 S8-Z63 00 0. S8-Z0. 6 S8-Z 6.6 S8-Z.6 6 S8-Z 6 3 S8-Z3 6 4 S8-Z4 6 6 S8-Z6 6 8 S8-Z8 6 B 9. 0 S8-Z0 6 6 S8-Z6 6 0 S8-Z0 6 S8-Z 84 3 S8-Z3 70 40 S8-Z40 76 0 S8-Z0 06 63 S8-Z63 3 0. S83-Z0. 44 S83-Z 44.6 S83-Z.6 44 S83-Z 44 3 S83-Z3 44 4 S83-Z4 44 6 S83-Z6 44 8 S83-Z8 44 B 3 3.9 0 S83-Z0 44 6 S83-Z6 44 0 S83-Z0 44 S83-Z 48 3 S83-Z3 4 40 S83-Z40 66 0 S83-Z0 306 63 S83-Z63 344 Sugg. Rated Catalog List Delivery Wgt. oz. order current number price class ( pc.) qty 0. S8UC-Z0. $ 68 S8UC-Z 68.6 S8UC-Z.6 68 S8UC-Z 68 3 S8UC-Z3 68 4 S8UC-Z4 68 6 S8UC-Z6 68 8 S8UC-Z8 68 0 S8UC-Z0 68 B 0 4.6 6 S8UC-Z6 68 0 S8UC-Z0 68 S8UC-Z 70 3 S8UC-Z3 76 40 S8UC-Z40 88 0 S8UC-Z0 6 63 S8UC-Z63 4 0. S8UC-Z0. 390 S8UC-Z 390.6 S8UC-Z.6 390 S8UC-Z 390 3 S8UC-Z3 390 4 S8UC-Z4 390 6 S8UC-Z6 390 8 S8UC-Z8 390 0 S8UC-Z0 390 B 9. 6 S8UC-Z6 390 0 S8UC-Z0 390 S8UC-Z 398 3 S8UC-Z3 40 40 S8UC-Z40 46 0 S8UC-Z0 498 63 S8UC-Z63 8 0. S83UC-Z0. 94 S83UC-Z 94.6 S83UC-Z.6 94 S83UC-Z 94 3 S83UC-Z3 94 4 S83UC-Z4 94 6 S83UC-Z6 94 8 S83UC-Z8 94 B 3 3.9 0 S83UC-Z0 94 6 S83UC-Z6 94 0 S83UC-Z0 94 S83UC-Z 603 3 S83UC-Z3 6 40 S83UC-Z40 67 0 S83UC-Z0 76 63 S83UC-Z63 8 0,000 000 000 00 UC-Z 0,000 000 000 00 Z Switched neutral To create a miniature circuit breaker from stock items with a switched neutral, order standard MCB (usually a single or three pole version) and a neutral disconnect module, S-NT, which can be field added to the MCB. See accessories page.8. 00 0 0 00 0 0 Direct current applications Please refer to the chart on page... seconds 0. 0. 0.0 DC 0.0 3 0 0 30 multiple of rated current seconds 0. AC 0. 0.0 DC 0.0 3 0 0 30 multiple of rated current Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery ABB Control Inc. Discount schedule CB7.3 AC 600 3/00

S90 C S90 77/480 VAC C VDE 0660 Cable and equipment protection S9-C80 480 VAC Class Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 80 S9-C80 $ 38 00 S9-C00 44 B 6 9. S9-C 9 80 S9-C80 340 00 S9-C00 364 B 3 8.4 S9-C 68 80 S93-C80 36 00 S93-C00 48 B 7.6 S93-C 73 80 S94-C80 740 00 S94-C00 76 B 36.8 S94-C 948 Auxiliary contact S90-H 7 B.7 S90-H Bell alarm S90-S B.7 Shunt trip S90-A 44 B 6. For field mounting, left side, 0V 4VAC S90-A 44 B 6. For field mounting, left side, 4 48VDC Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery 0,000 000 C 000 00 00 0 0 seconds 0. 0. 0.0 0.0 AC DC 3 0 8 0 30 multiple of rated current.4 Discount schedule CB9 ABB Control Inc. AC 600 3/00

Accessories Busbars S60, S70, S80 Acc. Phase L... L Amp rating Number End cap Suggested Weight Busbar Catalog List Delivery of catalog order qty. ounce length number price class poles number quantity ( pc.) 07 SZ-KS/ $ 0 0.6 6 988 SZ-KS/6 36 A.6 8 6 988 SZ-KS/6 46. 0 6 988 SZ-VB4.3 68 0.0 Uninsulated copper bar mounts flush with bottom edge of circuit breakers. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. Phase Amp rating Number End cap Suggested Weight Busbar Catalog List Delivery of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 8 03 PSB-END3 SZ-PSB4N $ 4.4 6 8 03 PSB-END3 SZ-PSB6N A 9. 0 3 PSB-3UL 40 4.0 L L L L... L L Insulated busbar assembly contains separate circuits for use with, +N or pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. 3 Phase Amp rating Number End cap Suggested Weight Busbar Catalog List Delivery of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 3 PSB-3UL $ 60 3 4.3 6 60 06 PSB-END SZ-PSB4N 30 A.4 0 60 06 PSB-END6 SZ-PSBN 76 34. L L L3 Insulated busbar assembly contains 3 separate circuits for use with or 3 pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L L L3 L L L3... 4 Phase Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 60 03 PSB-END4 SZ-PSB6N $ 04 3. A 6 60 988 PSB-END4 SZ-PSB64N 36 3.6 Insulated busbar assembly contains 4 separate circuits for use with 3+N or 4 pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L L L3 L4 L L L3 L4... L L L3 L4 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery ABB Control Inc. Discount schedule CB8. AC 600 3/00

Acc. Accessories Busbars S60, S70, S80 Phase with auxiliary L Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of length catalog number price class order qty. ounce poles number quantity ( pc.) 0 39 044 PSB-END3 SZ-KS3/39N $ 0 A 7.4 6 39 044 PSB-END3 SZ-KS4/39N 6 A 0. Uninsulated copper bar mounts flush with bottom edge of circuit breakers. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L L L... 3 Phase for pole MCB s with auxillary L L L3 L L L3... Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 8 044 PSB-END3 SZ-PSB46N $ 4 B 6. 6 8 044 PSB-END3 SZ-PSB48N 8 B. Insulated busbar assembly contains separate circuits for use with, +N or pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. Phase with auxillary Amp rating Number End cap Suggested Weight Busbar Catalog List Delivery of catalog order qty. ounce length number price class poles number quantity ( pc.) 6 48 06 SZ-PSB9N 74 B 3. Insulated busbar assembly contains 3 separate circuits for use with or 3 pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L L L L L L L L... 3 Phase with auxillary L L L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of length catalog number price class order qty. ounce poles number quantity ( pc.) 0 48 980 PSB-END3 SZ-PSB0N $ 4 B.8 6 48 980 PSB-END3 SZ-PSBN 8 A.6 Insulated busbar assembly contains 4 separate circuits for use with 3+N or 4 pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L L L3 L L L3... Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery.6 Discount schedule CB8 ABB Control Inc. AC 600 3/00

Accessories Busbars S60, S70, S80 Acc. 3 Phase L L L3 L L L3... L L L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 3 SZ-PSB $ 40 4. 0 60 06 SZ-PSB 30.4 A 6 3 SZ-PSB3 0 6.0 6 60 06 SZ-PSB4 76 34. Insulated busbar assembly contains 3 separate circuits for use with, +N or 3 pole MCBs. For use on line side (top) of S60 and S70 MCBs. 3 ph + N, for use with pole MCB s on 3 ph / 4W system L... L Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 0 SZ-KS6/N $ 3. A 0 6 007 SZ-KS6/6N 9.0 Insulated busbar assembly contains circuit for use with pole MCBs. For use on line side (top) of S60 and S70 MCBs. 3 Phase + N, for use with pole MCB s on 3 phase / 4W system N L L L3 Amp rating Number End cap Suggested Weight Busbar Catalog List Delivery of catalog order qty. ounce length number price class poles number quantity ( pc.) 0 8 048 PSB-END4 SZ-PSB8N $ 98 B.3 6 8 048 PSB-END4 SZ-PSB60N 38 A 30.8 Insulated busbar assembly contains 4 separate circuits for use with +N or pole MCBs. For use on load side (bottom) of S60, S70, S80 and line side (top) of S80 MCBs. L N L N L3 N L N L... MCB Busbar accessories Busbar mounted terminal block p/n: SZ-ESK -pole Busbar End Caps Bus tooth covers p/n: SZ-BSK -poles Busbar end caps Catalog List Delivery Suggested Weight Description number price class order qty. ounce qty. ( pc.) Busbar tooth covers (shrouds unused portion of busbar) IEC busbar mounted terminal block pole, for use on all busbars PSB-END3 PSB-END4 PSB-END PSB-END6 $ A 0 SZ-BSK 4 A 0 SZ-ESK 0 A.0 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery ABB Control Inc. Discount schedule CB8.7 AC 600 3/00

Acc. Accessories S60, S70 & S80 S-H Auxiliary contacts Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) For field mounting: left side N.O./ N.C. S-H $ 36 N.O. S-H0 36 N.C. S-H0 36 N.O./ N.C. S-H 4 N.O./ N.C. S-H 4 N.O./ N.C. (low voltage) S-HKL 60 A.4 The S-H auxiliary switch can be field mounted to any S60, S70 or S80 series breaker. The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 6A/40 VAC and.a/0 VDC. Minimum operating voltage is VAC/VDC. Bell alarm For field mounting, left side S-S 48 A.4 The S-S bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 6A/40 VAC and.a/0 VDC. Minimum operating voltage is VAC/VDC. S-A Bell alarm with auxiliary contact For field mounting, left side S-S/H 8 A.4 The S-S/H bell alarm with auxiliary contact device combines one set of bell alarm contacts with one set of auxiliary contacts (N.O.). Shunt trip For field mounting, left side -60 VAC (-60VDC) S-A 0-4 VAC (0-0 VDC) S-A 38 A. For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available depending on control system voltage (-4 VAC/VDC). S-BM Undervoltage release For field mounting, left or right side V 4V 48V 0V 0V 380V S-BM S-BM S-BM3 S-BM4 S-BM S-BM6 6 A. When control voltage drops below approximately 0% of rated voltage, the S-BM opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory; can be left or right side mounted. S-S Hand operated neutral disconnect For field mounting, right side, 40A max. S-NT 7 A.4 When switching of neutral with breaker contacts is desired, the neutral module S-NT can be added to any S60, S70 or S80 MCB. The neutral connection makes before the MCB contacts connect line to load. Makes contact before MCB contacts close. Must be opened manually. S-S/H Factory mounting All accessories can be easily mounted in the field. For factory mounting of any accessory devices, add $30 list to total price per breaker. To create complete catalog number, take suffix of accessory device following S- and add suffix to end of breaker part number. Multiple suffixes must be added in alphabetical order. Example: S7-K0A $ 64 ( pole, 0A breaker with type A shunt trip) S7-K0 @ $96 + A @ $38 + factory mounting @ $30 = $64 S7-K0AH $ 300 ( pole, 0A breaker with type A shunt trip and H aux. contacts) S7- K0 @ $96 + A @ $38 + H @ $36 + factory mounting @ $30 = $300 Auxiliary contacts and shunt trips may be mounted in combination. Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery S-NT NOTE: Above accesssories are for use with types S60, S70 and S80 breakers only..8 Discount schedule CB8 ABB Control Inc. AC 600 3/00

Accessories S60, S70, S80 Acc. S00-ME Front mounting kit Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) For poles S00-ME $ 60. For poles S00-ME 70 A.9 For 0 poles S00-ME3 80 3.6 Optional rear terminals ( per kit) MB-RT 6. Includes flange, mounting rail, terminals for rear connection and hardware. Front mounting clip For 4 poles MB-CL 3 A Simple mounting clip for up to four module mounting. Front mounting bracket For 3 poles MB-3PD 3 A. For flush mounting of three pole MCBs: includes hardware. MB-CL Pin-type connector AWG (3mm ) SZ-AST3 9 A 0 0. Needed for connecting large cable AWG (3mm ) and busbar on same breaker. Locking device Adaptor only SA 9 0.7 A 0 Padlock only w/ keys SA 9 0. Allows breaker to be locked in ON or OFF position. MB-3PD Labeling accessory sheet = 00 blank labels sheet = 00 numbered labels STL-ST 74 A Snaps into rail indent on front of MCB Label holder & labels includes 00 label carriers. SZ-AST3 Enclosure, IP For 4 modules 644 84 8. For 6 modules 646 98 A 0.8 For 0 modules 60 6 0.4 For 0 modules 6 0 4.0 Molded plastic complete with mounting rail and knock-outs for cable entries. Blanking plates Single pole (set of 0) BP-P 6 A Twelve pole (snap-off, set of ) BP-P 7 SA Terminal covers For modules PCD 3.0 For 4 modules PCD4 4.8 A For 6 modules PCD6 6 3.4 For 8 modules PCD8 66 4. For additional protection against accidental contact. Includes integrated mounting rail. SA Handle mechanism RHS-M 76 A 9. For use with, 3 and 4 pole S MCBs and disconnect switch selector handles with mm shaft. Mounting rail Universal mounting SMR-39 A 8 3mm DIN rails are available in 39-inch strips ( meter). Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery ABB Control Inc. Discount schedule CB8.9 AC 600 3/00

Tech data Technical data Mounting and operating instructions Mounting MCB Removing MCB Mounting Universal mounting position using snap-on mounting to standard 3x7.mm DIN rail. Miniature circuit breakers (MCBs) can also be mounted to front of door using a panel cut-out with breaker handle protruding through panel opening for external operation. Special front mounting kit type ME is available (see page.). Connection Terminals are suitable for solid or flexible conductors from 8 to 4 AWG (0.7 to mm ) with no busbar connected. When maximum busbar size of 36 mm is used, maximum cable is 6 AWG (6 mm ). Maximum tightening torque of 7. in-lb ( Nm) for line/load terminals and 4. in-lb (0.Nm) for accessory device terminals. Possible mounting arrangements of MCB accessories Operation MCBs are switched on by moving the handle to the upper position. Stamped onto the handle switch, a I is visible confirming that the breaker is closed. The MCBs are trip-free, if the handle is being forced to the ON position, the breaker will still trip under fault conditions. The O marking indicates that the breaker is in the OFF position. The MCB is now open and the load is disconnected from line power. When a breaker has tripped, the MCB handle should first be set to the full OFF position to make certain the trip mechanism has been reset. Once the fault has been determined and cleared the MCB can again be switched ON. Maintenance ABB miniature circuit breakers require no special maintenance; only normal electrical system maintenance procedures are required. H S S/H MCB NT H S S/H A BM MCB A BM MCB BM Auxiliary switch/bell alarm neutral disconnect Auxiliary switch Shunt trip or undervoltage release mounted with auxiliary switch Shunt trip and/or undervoltage release Set MCB to OFF position and mount Set breaker to ON position Break out opening on side of MCB auxiliary switch to side of breaker Attach with spring clamps Bell alarm with auxiliary contact Set MCB to OFF position, insert metal pin as Break out opening on side of MCB noted above with arrow and mount device to Set breaker to ON position and remove seal side of MCB Attach with spring clamps Shunt trip and undervoltage release Remove seal Add shunt trip to MCB Attach with spring clamps.0 ABB Control Inc. AC 600 3/00

Technical data Busbars & connectors Connection methods Tech data Dual function terminals provided in open position for connection to busbars. Pressing on screw head opens box terminal for cable insertion. Only the lower terminal is dual function. Terminals allow for connection of cable 8-4 AWG. Conductors of different sizes may also be used in same terminal. Up to five conductors, 6 AWG each, can be safely connected per terminal. Lower terminals can be bussed together with single phase or multi-phase busbars as shown. Upper terminals can also be busbar connected. Lower terminal can also be bussed with solid round conductor. Cables can be connected to box terminals in addition to busbar connections on lower, dual function terminals. ABB Control Inc.. AC 600 3/00

Tech data Technical data S60, S70, & S80 Item S60-B S60-C, -D S70-K S80-K Approvals: UL 077 077 077 077 CSA C. No.3 C. No. 3 C. No. 3 C. No. 3 VDE 064, 0660 0660 0660 0660 IEC 898, 947 898, 947 898, 947 898, 947 No. of poles:,,3,4 +N,3+N,,3,,3,4, +N,3+N,,3,4,+N,3+N Tripping characteristic: B C,D K K Rated currents: 6 to 63A 0. to 63A 0. to 63A 0. to 63A Minimum operating voltage: V V V V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 0VAC 0kA 0kA 0kA 0kA for 0.-40A 6kA for 0-63A 40VAC 6kA 0kA 6kA 0kA 6kA 0kA 0kA for 0.-40A 0kA for 0.-3A 6kA for 0-63A 6kA for 40-63A 77VAC 6kA 6kA 6kA 0kA for 0.-40A 77/480 VAC 6kA 6kA 6kA 0kA for 0.-3A 6kA for 40-63A 60VDC 0kA 0kA 0kA 0kA 0kA 0kA VDC 0kA 0kA 0kA Frequency: 0/60Hz (See below) 0/60Hz (see below) 0/60Hz (see below) 0/60Hz (see below) Rated voltage IEC single pole 40/4VAC 40/4VAC 40/4VAC 40/4VAC 60VDC 60VDC 60VDC 60VDC IEC multi-pole 4VAC 4VAC 4VAC 4VAC 0VDC 0VDC 0VDC 0VDC Protection category: IP0 IP0 IP0 IP0 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 3mm DIN rail 3mm DIN rail 3mm DIN rail 3mm DIN rail Terminals: Conductors from 8-4AWG Conductors from 8-4AWG Conductors from 8-4AWG Conductors from 8-4AWG (0.7 sq mm) (0.7 sq mm) (0.7 sq mm) (0.7 sq mm) 0A and above 0A and above 0A and above 0A and above Conductors from 8-AWG Conductors from 8-AWG Conductors from 8-AWG Conductors from 8-AWG (0.7 3sq mm) (0.7 3sq mm) (0.7 3sq mm) (0.7 3sq mm) Service life at rated load: 0,000 operations 0,000 operations 0,000 operations 0,000 operations Ambient temperatures: - C to + C - C to + C - C to + C - C to + C Shock resistance: 0g minimum of 0 impacts, 0g minimum of 0 impacts, 0g minimum of 0 impacts, 0g minimum of 0 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: g, minimum of 30 minutes g, minimum of 30 minutes g, minimum of 30 minutes g, minimum of 30 minutes Disconnecting neutral rating: 6kA switching 6kA switching 6kA switching Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 0/60Hz applications. For frequencies other than 0/60Hz, the magnetic (instantaneous) trip values are increased by the factor given below: 6 /3-60Hz 00Hz 00Hz 400Hz DC Approx. factor.... Thermal tripping is independent of frequency.. ABB Control Inc. AC 600 3/00

Technical data S80, S80UC, S90 Tech data Item S80UC-K S80-Z S80UC-Z S90-C Approvals: UL 077 077 077 CSA C. No. 3 C. No. 3 C. No. 3 VDE 0660 0660 0660 0660 IEC 898,947 898, 947 898, 947 898 No. of poles:,,3,,3,4,,3,,3,4 Tripping characteristic: K Z Z C Rated currents: 0. to 63A 0. to 63A 0. to 63A 80 to A Minimum operating voltage: V V V V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 0VAC 6kA for 0.-40A 0kA for 0.-40A 6kA for 0.-40A ka for 0-63A 6kA for 0-63A ka for 0-63A 40VAC 6kA for 0.-40A 6kA for 0.-40A 0kA for 0.-40A 0kA for 0.-3A 6kA for 0.-40A 6kA for 0.-40A ka for 0-63A ka for 0-63A 6kA for 0-63A 6kA for 40-63A ka for 0-63A ka for 0-63A 77VAC 4.kA for 0.-40A 0kA for 0.-40A 4.kA for 0.-40A ka for 0-63A 6kA for 0-63A ka for 0-63A 77/480 VAC 4.kA for 0.-40A 0kA for 0.-3A 4.kA for 0.-40A ka for 0-63A 6kA for 40-63A ka for 0-63A 60VDC 0kA 0kA 0kA 0kA VDC 0kA 0kA 0kA 0kA 0VDC 4.kA 4.kA 4.kA 4.kA 00VDC 4.kA 4.kA Frequency: 0/60Hz (see below) 0/60 Hz (see below) 0/60Hz (see below) 0/60Hz (see below) Rated voltage IEC single pole 40/4VAC 40/4VAC 40/4VAC 30/440VAC 0VDC 60VDC 0VDC 60VDC IEC multi-pole 4VAC 4VAC 4VAC 440VAC 440VDC 0VDC 440VDC 0VDC Protection category: IP0 IP0 IP0 IP0 Depth of unit per DIN 43880: 68mm 68mm 68mm 70mm Mounting position: optional optional optional optional Standard mounting: 3mm DIN rail 3mm DIN rail 3mm DIN-rail 3mm DIN-rail Terminals: Conductors from 8-4AWG Conductors from 8-4AWG Conductors from 8-4AWG Conductors from 4-/0AWG (0.7 sq mm) (0.7 sq mm) (0.7 sq mm) (. 0sq mm) 0A and above 0A and above 0A and above Conductors from 8-AWG Conductors from 8-AWG Conductors from 8-AWG (0.7 3sq mm) (0.7 3sq mm) (0.7 3sq mm) Service life at rated load: 0,000 operations 0,000 operations 0,000 operations 0,000 operations Ambient temperatures: - C to + C - C to + C - C to + C - C to +4 C Shock resistance: 0g minimum of 0 impacts, 0g minimum of 0 impacts, 0g minimum of 0 impacts, 30g minimum of 0 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: g, minimum of 30 minutes g, minimum of 30 minutes g, minimum of 30 minutes 60m/s, at 0 0 Hz Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 0/60Hz applications. For frequencies other than 0/60Hz, the magnetic (instantaneous) trip values are increased by the factor given below: 6 /3-60Hz 00Hz 00Hz 400Hz DC Approx. factor.... Thermal tripping is independent of frequency. ABB Control Inc..3 AC 600 3/00

Tech data Technical data Let-through values Description All ABB miniature circuit breakers substantially reduce the maximum let-through current from the peak available short circuit current. I K - RMS current of fault I D - Max let-through of MCB V n - System voltage V B - Arc voltage of MCB t k - Breaking time of MCB Let-through values I t S60-B S70-K S80-K For other curves, please contact ABB Control. Version I t I Peak S60B TD9980 S60C TD998 S60D TD998 S70K TD997 TD990 S80K TD9978 S80Z TD9979 S90C TD998 Version Amps Time-current trip S60B 6-63 TD97 S70K 0. - 8 TD970 0-40 TD9706 0-63 TD9707 S80K 0. - 8 TD9708 0-40 TD9709 0-63 TD970 S80Z 0. - 63 TD97.4 ABB Control Inc. AC 600 3/00

Technical data Temperature derating factors Terminal markings Tech data Type B, C, D Type K, Z Current carrying capacity of type B, C, D, K and Z thermal trip characteristics as a function of ambient temperature. Terminal markings Input optional from top or bottom. 3 3 3N 3 7N 4 4 6 4N 4 6 8N Pole Pole 3 Pole Pole & NA 3 Pole & NA D 3 BELL ALARM 9 AUX SW C U 4 96 98 4 I C D H S/H A / A BM ABB Control Inc.. AC 600 3/00

Tech data Technical data Breaker resistance values & wire size comparison Miniature circuit breaker resistance values Ampere Milliohms rating S60-B S70-K S80-K S80-Z 0. 33300 0.3 9700 0. 6340 00 000 0.7 400.0 0 390 70.6 69 6 00 460 40 69 3 6 47 0 4 0 49 6 4. 04 8 38 33.8 3.9 0 3.3.6. 7. 3.3.6 6 7.0 7.7 8. 0.9 0 6. 6.7.7 6.0.0 4.6 3.97 4. 3 3.6 3..6.8 40 3.0.8.44. 0....77 63.4 0.70 0.70.3 Comparison of IEC and AWG wire sizes mm AWG (mm ) Amps / UL Amps / IEC.0 8 6 (.3) 0. 4 (.). 0 (3.3) 0 4 0 (.3) 30 6 3 8 (8.4) 0 0 0 6 (3.3) 6 6 6 4 (.) 8 8 3 (6.7) 00 (33.6) 3 Ampacities for AWG wire are based on copper cable rated 7 C, except for 6AWG which is based on 60 C wire. Taken from UL08 Table.. Consult applicable standards for futher detail and information..6 ABB Control Inc. AC 600 3/00

00.00 00.00 Inches Millimeters Approximate dimensions S60, S70, S80, S90 Dims S60 & S70 3.4 (90.0).7 (69.0) 0.69 (7.) 0.69 (7.) 0.69 (7.) CL.07 (.) 0.69 (7.) UPPER TERM..77 (4.0) LOWER TERM. CL.9 (74.9) 0.8 (4.8) CL.68 (68.0) CL.46 (37.).98 (0.) S80 3.4 (90.0).7 (69.0) 0.69 (7.) 0.69 (7.) CL 0.69 (7.).07 (.) 0.69 (7.) UPPER TERM..77 (4.0) LOWER TERM. CL.9 (74.9) 0.8 (4.8) CL.68 (68.0).46 (37.).98 (0.) S90.77 4.97 0.03 6.3 4.06 7 0.69 7. 0.3 9 0.3 9 3.9 8 -A, -A -H -S ABB Control Inc..7 AC 600 3/00

Dims Approximate dimensions Accessories 00.00 00.00 Inches Millimeters Accessories H/S (/X) Left side mtd H (/X) A (X) 3-pole MCB Left or right side mtd U (X) 0.3 8.8 0.3 8.8 0.69 7. 0.69 7. MB-CL.77 4 D C.L..6 7..77 4 C.L. 0.69 7..38 3.07. MB-3PD 3.. ( 3P ).43 ( P ).87 C L C L BREAKER CUT OUT BKT. MT. HOLES 0. DIA. TYP 0.74 ( P ) RHS-M CL.07..38 3 0.0 0. 0.63 6 0.83 0.97 4.7.77 4 CL 3.4 90 0.34D 8.6D 0.80 0.3 3.6 8. 4.36 0.4.89 48 0.0. 0.7 6.9.8 ABB Control Inc. AC 600 3/00

00.00 00.00 Inches Millimeters Approximate dimensions Accessories Dims 644 60 4.9 4.3 0 4.9 4.9 4.3 0 30 9.06 7.09 80 7.09 80 646 66 4.9 4.3 0 6.30 60 6.09.3 3 9.84 0 7.09 80.60 30 ABB Control Inc..9 AC 600 3/00

X-ref Cross-reference Older Suggested Physical Electrical version replacement comparison comparison series S60L S60B Same pole spacing Same trip characteristic as L S60K S70K Same pole spacing Same trip characteristic as K S70 is 6kA IC S0L S60B Same pole spacing Same trip characteristic as L S60B is 6kA IC S0K S80K Same pole spacing Same trip characteristic as K S80K is 6kA IC S0Z S80Z Same pole spacing Same trip characteristic as Z S0L S60B Same pole spacing Same trip characteristic as L S0-UCK S80UC-K Same pole spacing Same trip characteristic as K S0-UCZ S80UC-Z Same pole spacing Same trip characteristic as Z S0-K S00-K Different pole spacing Same trip characteristic as K S30-B S60-B Same pole spacing Same trip characteristic as B Many older styles of ABB miniature circuit breakers have been replaced by new and improved versions. Many of these newer styles can be directly interchanged, both electrically and physically, with the older version. There are also many international styles of ABB circuit breakers which are not normal stock items and may be interchanged with stocked ABB versions. Note: MCB types S60/70 and S80 can be raised to the same height as older style S0 series MCBs through the use of a height adjuster (SZ-ES68/83; $ 30 list per 0). The height adjustor snaps onto the DIN rail and raises the height of components 68mm to match that of the S0 series (83mm)..30 ABB Control Inc. AC 600 3/00

Miniature Circuit Breakers S00 Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding safety, reliability and switching capacities. The S00 heavy-duty circuit breaker fulfills these requirements by virtue of its technical features. It is equipped with a thermal and/or electromagnetic release to protect circuits, motors, switchgear and systems from the effects of overload and short-circuit currents. For the worldwide market, the S00 breakers carry UL, CSA, IEC, CE and many other agency approvals. Features High breaking capacity Energy-limiting Current-limiting Extremely fast breaking time Optimal selectivity Various versions for special applications Compact dimensions, DIN cap size Easy and quick to install Easy to connect; finger safe terminals Wide range of accessories UL 077 recognized 600VAC and 00VDC versions ABB Control Inc..3 AC 600 3/00

S00 B & C S00 77/600 VAC B UL 077 CSA C. VDE 064 IEC 947- C VDE UL 077 CSA C. 064 IEC 947- S0-C6 S0-C6 S03-C0 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S0-B6 $ 68 0 S0-B0 68 3 S0-B3 68 6 S0-B6 68 0 S0-B0 68 S0-B 68 B 8.90 3 S0-B3 68 40 S0-B40 68 0 S0-B0 86 63 S0-B63 0 6 S0-B6 38 0 S0-B0 38 3 S0-B3 38 6 S0-B6 38 0 S0-B0 38 S0-B 38 B 7.8 3 S0-B3 38 40 S0-B40 38 0 S0-B0 36 63 S0-B63 39 6 S03-B6 478 0 S03-B0 478 3 S03-B3 478 6 S03-B6 478 0 S03-B0 478 S03-B 478 B.36 3 S03-B3 478 40 S03-B40 478 0 S03-B0 6 63 S03-B63 74 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S0-C6 $ 68 0 S0-C0 68 3 S0-C3 68 6 S0-C6 68 0 S0-C0 68 S0-C 68 B 8.90 3 S0-C3 68 40 S0-C40 68 0 S0-C0 84 63 S0-C63 0 6 S0-C6 38 0 S0-C0 38 3 S0-C3 38 6 S0-C6 38 0 S0-C0 38 S0-C 38 B 7.8 3 S0-C3 38 40 S0-C40 38 0 S0-C0 36 63 S0-C63 39 6 S03-C6 478 0 S03-C0 478 3 S03-C3 478 6 S03-C6 478 0 S03-C0 478 S03-C 478 B.36 3 S03-C3 478 40 S03-C40 478 0 S03-C0 6 63 S03-C63 74 0,000 000 000 00 00 0 B Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery 0 seconds 0. 0. 0.0 AC DC 0.0 3 7 0 0 30 multiple of rated current 0,000 000 C 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 0 8 0 30 multiple of rated current.3 Discount schedule CB0 ABB Control Inc. AC 600 3/00

S00 77/600 VAC S00 D & K seconds 0,000 000 000 00 00 0 0 0. 0. 0.0 S0-D0 S0-D3 S03-K6 D AC DC 0.0 3 0 0 30 multiple of rated current 0,000 000 000 00 00 0 K D VDE UL 077 CSA C. 064 IEC 947- Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) 3 S0-D3 $ 90 6 S0-D6 90 0 S0-D0 90 S0-D 90 3 S0-D3 90 B 8.90 40 S0-D40 90 0 S0-D0 0 63 S0-D63 6 3 S0-D3 37 6 S0-D6 37 0 S0-D0 37 S0-D 37 3 S0-D3 37 B 7.8 40 S0-D40 37 0 S0-D0 408 63 S0-D63 44 3 S03-D3 44 6 S03-D6 44 0 S03-D0 44 S03-D 44 3 S03-D3 44 B.36 40 S03-D40 44 0 S03-D0 600 63 S03-D63 646 K UL 077 CSA C. VDE 064 IEC-898 Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) 0. 0. S0-K0. $ 8 0.4 0. S0-K0. 8 0. 0.3 S0-K0.3 8 0.8 0.4 S0-K0.4 8 0.38 0.8 S0-K0.8 8 0.3 0.8 S0-K0.8 8 0.73. S0-K. 8. S0-K. 8.4. S0-K. 8 3 S0-K3 8.8 4. S0-K4. 8 B 8.90 3.8.8 S0-K.8 8.3 8 S0-K8 8 7.3 S0-K 8 0 S0-K 8 4 0 S0-K0 8 8 6 S0-K6 8 3 3 S0-K3 0 9 37 S0-K37 0 34 4 S0-K4 6 38 4 S0-K4 6 0. 0. S0-K0. 36 0.4 0. S0-K0. 36 0. 0.3 S0-K0.3 36 0.8 0.4 S0-K0.4 36 0.38 0.8 S0-K0.8 36 0.3 0.8 S0-K0.8 36 0.73. S0-K. 36. S0-K. 36.4. S0-K. 36 3 S0-K3 36 B 7.8.8 4. S0-K4. 36 3.8.8 S0-K.8 36.3 8 S0-K8 36 7.3 S0-K 36 0 S0-K 36 4 0 S0-K0 36 8 6 S0-K6 36 3 3 S0-K3 39 9 37 S0-K37 39 34 4 S0-K4 44 38 4 S0-K4 44 0. 0. S03-K0. 8 0.4 0. S03-K0. 8 0. 0.3 S03-K0.3 8 0.8 0.4 S03-K0.4 8 0.38 0.8 S03-K0.8 8 0.3 0.8 S03-K0.8 8 0.73. S03-K. 8. S03-K. 8.4. S03-K. 8 3 S03-K3 8 B.36.8 4. S03-K4. 8 3.8.8 S03-K.8 8.3 8 S03-K8 8 7.3 S03-K 8 0 S03-K 8 4 0 S03-K0 8 8 6 S03-K6 8 3 3 S03-K3 74 9 37 S03-K37 74 34 4 S03-K4 644 seconds 0 0. AC 0. 0.0 DC 0.0 3 8 0 0 30 multiple of rated current Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery ABB Control Inc. Discount schedule CB0.33 AC 600 3/00

S00 (UC) B S00UC 600 VAC/VDC B UL 077 CSA C. VDE 0660 S0UC-B40 S0UC-B6 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S0UC-B6 $ 6 0 S0UC-B0 6 3 S0UC-B3 6 6 S0UC-B6 6 0 S0UC-B0 6 S0UC-B 6 C 8.90 3 S0UC-B3 6 40 S0UC-B40 6 0 S0UC-B0 8 63 S0UC-B63 9 6 S0UC-B6 44 0 S0UC-B0 44 3 S0UC-B3 44 6 S0UC-B6 44 0 S0UC-B0 44 S0UC-B 44 C 7.8 3 S0UC-B3 44 40 S0UC-B40 44 0 S0UC-B0 0 63 S0UC-B63 68 Rated Catalog List Delivery Weight current number price class (oz.) pc 6 S03UC-B6 $ 646 0 S03UC-B0 646 3 S03UC-B3 646 6 S03UC-B6 646 0 S03UC-B0 646 S03UC-B 646 C.36 3 S03UC-B3 646 40 S03UC-B40 646 0 S03UC-B0 734 63 S03UC-B63 83 6 S04UC-B6 908 0 S04UC-B0 908 3 S04UC-B3 908 6 S04UC-B6 908 0 S04UC-B0 908 C 3.7 S04UC-B 908 3 S04UC-B3 908 40 S04UC-B40 908 0 S04UC-B0 030 63 S04UC-B63 64 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery S03UC-B0 S04UC-B 0,000 000 B 000 00 00 0 0 seconds 0. 0. 0.0 AC DC 0.0 3 7 0 0 30 multiple of rated current.34 Discount schedule CB0 ABB Control Inc. AC 600 3/00

S00 UC 600 VAC/VDC S00 (UC) K K VDE UL 077 CSA C. 0660 S03UC-K8 S04UC-K0 Rated Catalog List Delivery Weight current number price class (oz.) pc 0. 0. S0UC-K0. $ 0 0.4 0. S0UC-K0. 0 0. 0.3 S0UC-K0.3 0 0.8 0.4 S0UC-K0.4 0 0.38 0.8 S0UC-K0.8 0 0.3 0.8 S0UC-K0.8 0 0.73. S0UC-K. 0. S0UC-K. 0.4. S0UC-K. 0 3 S0UC-K3 0.8 4. S0UC-K4. 0 C 8.90 3.8.8 S0UC-K.8 0.3 8 S0UC-K8 0 7.3 S0UC-K 0 0 S0UC-K 0 4 0 S0UC-K0 0 8 6 S0UC-K6 0 3 3 S0UC-K3 86 9 37 S0UC-K37 86 34 4 S0UC-K4 30 38 4 S0UC-K4 30 0. 0. S0UC-K0. 488 0.4 0. S0UC-K0. 488 0. 0.3 S0UC-K0.3 488 0.8 0.4 S0UC-K0.4 488 0.38 0.8 S0UC-K0.8 488 0.3 0.8 S0UC-K0.8 488 0.73. S0UC-K. 488. S0UC-K. 488.4. S0UC-K. 488 3 S0UC-K3 488 C 7.8.8 4. S0UC-K4. 488 3.8.8 S0UC-K.8 488.3 8 S0UC-K8 488 7.3 S0UC-K 488 0 S0UC-K 488 4 0 S0UC-K0 488 8 6 S0UC-K6 488 3 3 S0UC-K3 8 9 37 S0UC-K37 8 34 4 S0UC-K4 6 38 4 S0UC-K4 6 Rated Catalog List Delivery Weight current number price class (oz.) pc 0. 0. S03UC-K0. $ 7 0.4 0. S03UC-K0. 7 0. 0.3 S03UC-K0.3 7 0.8 0.4 S03UC-K0.4 7 0.38 0.8 S03UC-K0.8 7 0.3 0.8 S03UC-K0.8 7 0.73. S03UC-K. 7. S03UC-K. 7.4. S03UC-K. 7 3 S03UC-K3 7.8 4. S03UC-K4. 7 C.36 3.8.8 S03UC-K.8 7.3 8 S03UC-K8 7 7.3 S03UC-K 7 0 S03UC-K 7 4 0 S03UC-K0 7 8 6 S03UC-K6 7 3 3 S03UC-K3 84 9 37 S03UC-K37 84 34 4 S03UC-K4 90 38 4 S03UC-K4 90 0. 0. S04UC-K0. 996 0.4 0. S04UC-K0. 996 0. 0.3 S04UC-K0.3 996 0.8 0.4 S04UC-K0.4 996 0.38 0.8 S04UC-K0.8 996 0.3 0.8 S04UC-K0.8 996 0.73. S04UC-K. 996. S04UC-K. 996.4. S04UC-K. 996 3 S04UC-K3 996 C 3.7.8 4. S04UC-K4. 996 3.8.8 S04UC-K.8 996.3 8 S04UC-K8 996 7.3 S04UC-K 996 0 S04UC-K 996 4 0 S04UC-K0 996 8 6 S04UC-K6 996 3 3 S04UC-K3 4 9 37 S04UC-K37 4 34 4 S04UC-K4 76 38 4 S04UC-K4 76 0,000 000 UC-K Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery 000 00 00 0 0 seconds 0. 0. 0.0 DC 0.0 3 0 0 30 multiple of rated current ABB Control Inc. Discount schedule CB0.3 AC 600 3/00

Acc. Accessories S00 S00-H Auxiliary contacts Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) Auxiliary contacts N.O./ N.C. S00-H N.O. S00-H0 $ 84 B.4 N.C. S00-H0 For field mounting left side Bell alarm with auxiliary contacts N.O./ N.C. S00-S N.O. S00-S0 9 B.4 N.C. S00-S0 For field mounting left side Handle mechanism S00-RD3 00 B 6. For use with 3 pole S00 MCBs and disconnect switch selector handles with mm shafts Electrical Catalog List Delivery Wgt. oz. accessories number suffix price class (pc.) Undervoltage release V -UA 4 V -UA4 48 V -UA48 0 V -UA0 30 V -UA30 00 V -UA00 Factory mount only. Shunt trip V -AL 4 V -AL4 48 V -AL48 0 V -AL0 30 V -AL30 00 V -AL00 Factory mount only. $ 66 B.7 4 B.7 Front mounting kit For pole S00-ME 6. to 3 poles S00-ME 3 A.9 to 7 poles S00-ME3 64 3.6 Delivery Class A - Standard item, stock to weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time D - 0 to week lead time E - Call for delivery.36 Discount schedule CB8 ABB Control Inc. AC 600 3/00

Technical data S00 Tech data Item S00-B, C, D S00-K Approvals: UL 077 077 CSA C. - No.3 C. - No. 3 VDE 064/6.78 064/6.78 IEC 947- No. of poles:,,3, +N, +NA,,3, +N, +NA Tripping characteristic: B.C.D. K Rated currents: 6 to 63A 0. to 4A Rated voltage: UL/CSA single pole 77VAC 77VAC UL/CSA multi pole 600VAC 600VAC IEC single pole 690VAC 690VAC Rated interrupting capacity: Single pole 6-A 30KA/40VAC 0.-A 30KA/40VAC 4KA/77VAC 4KA/77VAC 3-63A 8KA/40VAC 6-4A 8KA/40VAC 4KA/77VAC 4KA/77VAC Multi-pole 6-63A 4KA/480VAC 6-63A 4KA/480VAC 6KA/600VAC 6KA/600VAC Frequency: 0/60 Hz 0/60Hz Mounting position: optional optional Standard mounting: 3mm DIN rail 3mm DIN rail Terminals: Conductors from 6-4AWG Conductors from 6-4AWG (-sq mm) (-sq mm) Service life at rated load: 0,000 operations 0,000 operations Calibration temperature: 40 C 40 C Approvals: UL CSA VDE No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL single pole UL multi pole IEC multi pole Item S00UC-B, K 077 C. 0660,,3, 4 B, K B: 6 to 63A K: 0. to 4A 77VAC/0VDC 600VAC/600VDC 690VAC/70VDC Rated interrupting capacity: B single pole: 6 A 8KA/40VAC 4KA/77VAC 30KA/0VDC 3 63A 30KA/40VAC 4KA/77VAC 30KA/0VDC B two-pole: 6 63A 4KA/480VAC 6KA/600VAC 30KA/00VDC B three-pole: 6 63A 4KA/480VAC 6KA/600VAC 30KA/600VDC K single pole: 0. A 30KA/40VAC 4KA/77VAC 30KA/0VDC 3 63A 8KA/40VAC 4KA/77VAC 30KA/0VDC K two-pole: 0. 4A 4KA/480VAC 6KA/600VAC 30KA/00VDC K three-pole: 0. 4A 4KA/480VAC 6KA/600VAC 30KA/600VDC Frequency: Mounting position: Standard mounting: Terminals: Service life at rated load: Calibration temperature: 0/60Hz optional 3mm DIN-rail Conductors from 6 to 4AWG (-sq mm) 0,000 operations 40 C ABB Control Inc..37 AC 600 3/00

Dims Approximate dimensions S00 Accessories 00.00 00.00 Inches Millimeters S00.9 7.97 0 0.98 3.64 9..73 44 3. 80. 6..4 9.77 4 CL.9 7 3.6 9 S00-RD3 Handle mechanism 0.4 6 ;;; 3. 80.60 40.7 S00 Front mounting kit L.8 46.9 74 ; ; ; ; ; ; ; ; ; ; ; ; ; 4.4.00 CL CUT-OUT " L " L + 0. 3 CL 0.4 D 6 D L +.0 6 3.3 84 0.3 8.38 ABB Control Inc. AC 600 3/00

Residual current devices F360 series Pole 4 Pole Description RCDs provide ground fault equipment protection by monitoring the leakage of current to ground. The F360 series will trip when ground faults are detected in excess of the GF trip rating of the RCCB. These devices provide GF protection only and are used in series with standard MCBs which provide overload and short circuit protection. The F360 series can be used as a main device providing GF protection for several MCB branch devices. The F360 series are UL03 recognized for use in 77/480VAC applications. The F36 is for use in single phase/two wire or two wire systems. The F364 is for use in three phase/four wire systems. ABB Control Inc..39 AC 600 3/00