Portable Pack USER MANUAL

Similar documents
General Information. standard and advanced modular dimming. Sensor 96 dimmer rack

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

TOPAZ 12 PORTABLE PACK AND ASSOCIATED CONTROL MODULES USER GUIDE (Part # LIT A)

Elektralite LED Pro Line Pancake USER MANUAL (Version 2)

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

The WDS A Dimmer Users Manual Rev , 2012 City Theatrical, Inc.

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Neutron Pro Operations Manual

Dimmer Doubler User Manual

STAGE LIGHTING CONTROL EQUIPMENT

30A SMART ENERGY MANAGEMENT SYSTEM TM

LIPPERTCOMPONENTS, INC.

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Installation Instructions

Alliance Towel Dispensing System. Operation Manual

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

In-Wall Slide-Out OWNER'S MANUAL. Rev: Page 1 In-Wall Slide-out Owner's Manual

SAVE THESE INSTRUCTIONS

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

QTFX-F1, QTFX-F2 FLAME EFFECT

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

User Manual. Solar Charge Controller 3KW

Routine Maintenance Procedures

P/N Wheeler. user manual

9.2, 9.2s, 9.20, 9.20s Treadmill

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

LED Downlight Ceiling Fixtures

Installation Instructions

System 3 ZB1PS Device Chassis. Operator s Manual

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

User Manual Solar Charge Controller 3KW

LED Pinspot 2. Snapshot. User Manual

ES25 Battery-powered ACSR Cutter with 120 V Charger with 220 V Charger

LED Pinspot 2. Snapshot. User Manual

Level-Up (Towable) System

Installation, Operation and Maintenance Manual

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Transient Fault Location for Branch Circuit Breakers TFT Turquoise Circle Newbury Park, CA Toll Free:

Robotic Cleaner Troubleshooting Guide. Copyright 2010 Hayward Industries Inc.

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

USER MANUAL LUX-LD30W LED MOVING HEAD

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

Assembly Instructions MP-P2 Power Supply and Chassis Base Plate

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Installation and User Manual. with RAIN SENSOR.

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Cisco Beacon Point Module

Measurements are expressed in millimeters.

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Lighting BRINGING IMAGINATION TO LIGHT PHX 250 LED ZOOM PROFILE SPOT SUMMARY FEATURES Degree Zoom Lens Degree Zoom Lens

CH-158 Color Bank 8 USER MANUAL

60 Series Engine Controls

DC-Motor Controller. User Manual

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

If You Are Experiencing This, Click Thru:

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Troubleshooting Guide: 355 Lights (12V)

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

1 AMP CURRENT SOURCE

Installation Instructions

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

Electronic Circuit Breaker ESS20-0..

Installation, Operation and Maintenance Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

5 Operation 5.1 DESCRIPTION

LED Twister II. User manual UK Version 1.0

CALTRAP INSTALLATION AND OPERATIONS MANUAL

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

Lighting BRINGING IMAGINATION TO LIGHT PHX LED ZOOM PROFILE SPOT SUMMARY FEATURES Degree Zoom Lens Degree Zoom Lens

MODULATING SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

Snapshot. Hurricane 1300 USER MANUAL F-1300

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

INSTALLATION INSTRUCTIONS

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

TS , -850 Series TS , -850 Series TS-57031, TS

9.31, 9.33, 9.35 Treadmill

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

DIESEL Engine Fire Pump Controllers Features

Sunburst SB2400 Dimmer Rack and Receiver. Version 1.02 P/N F371

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Copyright 2005 Kegel

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

C954, C956 Treadmill

Hand Held Pull Tester Instruction Manual Order No

Transcription:

se nsor Portable Pack USER MANUAL Contents Introduction...3 SP6 face panel components... 3 SP12 face panel components... 4 Electronics modules...5 Removing...5 Dimmer modules...6 Circuit breakers...6 LEDs...6 Removing...6 Line and load s...7 SP6 single phase operation...8 SP12 single phase operation... 9 Input s...10 Connector pinout data...10 Beacon...11 Door......11 Cooling system...12 Specifications...12 Electronic Theatre Controls, Inc. UL and C UL Listed AC Lighting Loads ly For Indoor Use ly Utilizer Dans Un Endroit A L'Abri ETC Sensor dimming equipment is protected by US patent number 5,352,958. 7052M1002 3030 Laura Lane, Middleton, WI 53562 800/688-4116 FAX 608/836-1736 Copyright 1994-95 Electronic Theatre Controls, Inc. Specifications subject to change. Revised 7-95.

2 Electronic Theatre Controls, Inc.

Introduction The Sensor Portable Pack is a modular dimming system that consists of a single electronics module and multiple dimmer modules in a fan-cooled, aluminum and steel housing. It is available in standard and Advanced Features (AF) configurations. ❶ ❷ Beacon Analog sensor 0-10 VDC In AMX192 Out In DMX512 Thru sensor ❸ Address Reset Error IAS Phase C Analog DMX AMX ❹ ❺ SP6 Portable Pack ❶ LED beacon ❷ Input panel ❸ Electronics module (MPE shown) ❹ Door ➎ Circuit breakers Sensor Portable Pack User Manual 3

Beacon Analog 0-10 VDC In AMX192 Address Out Phase C DMX In Error IAS Analog AMX DMX512 Reset Thru ❶ ❷ sensor sensor ❸ ❹ ❺ SP12 Portable Pack ❶ LED beacon ❷ Input panel ❸ Electronics module ❹ Door ➎ Circuit breakers 4 Electronic Theatre Controls, Inc.

Electronics modules Standard configuration Sensor Portable Packs are generally equipped with a Multi-Protocol Electronics (MPE) module. MPE modules are factory-configured for seven user-selectable dimmer configurations and accept DMX512, AMX192 and 0 10V DC analog input. Advanced Features (AF) packs are equipped with a Control Electronics Module (CEM). CEMs accept only DMX512, but feature an easy-to-use user interface that incorporates an integral LCD and keypad. Like all Sensor dimming systems, the Portable Pack provides feedback on dimming system status. In packs equipped with the MPE, this is accomplished via a warning beacon and a system of flashing LEDs. AF packs also provide a warning beacon, but the CEM also provides extensive error messages and warnings on the integral LCD. In addition, AF packs may be networked on ETCLink, and provide feedback information on individual dimmer modules. For more information regarding the electronics module, see the CEM User Manual or MPE User Manual that was shipped with your system. sensor 1 Address 1 1 Reset Error IAS Phase C Analog DMX AMX Multi-Protocol Electronics (MPE) Module sensor Dimmer About 7 4 8 5 9 6 Exit Next OA OB Backup 1 2 3 Thru OC ETCLink Setup A/B 0 At Clear Enter Reset Control Electronics Module (CEM) Removing electronics modules To remove the electronics module, follow these steps: 1. Open the door. 2. Pull the small metal handle out of the bottom edge of the front panel. 3. Grasp the handle and gently pull the electronics module out. To replace the module, insert it firmly until you feel it seat securely. When the module is correctly seated, it should be flush with the dimmers. Be sure to slide the handle back into the front panel. Sensor Portable Pack User Manual 5

Dimmer modules Each SP6 contains one electronics module and either six standard or three double-height dimmer modules. Each SP12 contains one electronics module and either twelve standard or six double-height dimmer modules. Sensor packs support 15A, 20A, 50A, or 100A dimmer modules in various combinations. (Custom dimmer configurations are available by special order.) OFF OFF 20 20 ❶ Standard Sensor 20A dimmer module (D20) ❷ Signal 20 A Signal 20 A Except for 15A and 20A modules, which are interchangeable, module slots are designed to accept only the size module specified for that space. Do not attempt to insert a module into a slot configured for a different size module. ❶ Dimmer module circuit breakers the left end of a dimmer module s front panel are either one or two circuit breakers (depending on whether the module is single or dual). If the breaker switch is to the right, the circuit is off or tripped. If the breaker switch is to the left, the circuit is on. ❷ LEDs All modules have an LED marked Signal on the right end of the front panel. The Signal LED is on whenever the pack is receiving DMX512 input. Sensor AF (Advanced Features) dimmer modules also have an LED marked Output which is on whenever the dimmer has an output voltage. Dual modules have two sets of LEDs. Removing dimmer modules To remove dimmer modules, open the door, then grasp the center part of the face panel with both hands and pull. To replace the module, insert it firmly until you feel it seat securely. When the module is correctly seated, it should be flush with the other dimmer modules. Warning: Do not touch the AC power bus. If more than one adjacent modules are removed, the AC bus is exposed. 6 Electronic Theatre Controls, Inc.

Line and load s The back panel of the Sensor Portable Pack contains both line and load s. Load s The Sensor Portable Pack may be configured with either stage pin; grounded twistlock; parallel blade; or multi-pin s (Veam, Socapex or Pyle) to connect the pack to lights or other output devices. Line feed s The back panel contains Cam-Lok E1016 series line feed s. Line feed cables with mating s (not supplied) must be connected to the Cam-Lok power s in the order described below. To connect the Cam-Lok, insert it into the back of the pack, then twist clockwise until it locks in place. Reverse this procedure to disconnect the cables. Connect cables in this order: 1. Grounding plug (Green) 2. Neutral plug (White) 3. Phase plugs (Black/Red/Blue) Warning: Cables must be disconnected in the reverse sequence! Warning: Multiple power leads may be attached to the Portable Pack. Disconnect all power leads before servicing or attempting to work on any part of this device. Service s must be installed and removed by qualified personnel only. Sensor Portable Pack User Manual 7

Setting up SP6 for single phase operation To convert a Sensor SP6 Portable Pack from three phase to single phase operation, follow these steps: 1. Disconnect power from all Cam-Loks. 2. Remove all dimmer modules from the Portable Pack, exposing the bus bars and s. 3. Remove the screws at the right ends of the two inch long copper bars that connect the phase B to the phase B bus bar. Loosen the screws at the left end of the bars. 4. Rotate the top bar up and secure it to the phase A. 5. Rotate the bottom bar down and secure it to the phase C. 6. Tighten all screws to 40 inch/pounds of torque. 7. Replace dimmer modules. 8. Connect power to the A and C phase Cam-Loks. Do not connect power to the B phase Cam-Lok. Single phase operation is automatically detected by both the CEM and the MPE, so no additional configuration is necessary. Phase C Phase C Phase s wired for three phase operation Phase s wired for single phase operation 8 Electronic Theatre Controls, Inc.

Setting up SP12 for single phase operation To convert a Sensor SP12 Portable Pack from three phase to single phase operation, follow these steps: 1. Disconnect power from all Cam-Loks. 2. Remove all dimmer modules from the Portable Pack, exposing the bus bars and s. 3. Remove the screws at both ends of the two inch long copper bars that connect the phase B to the phase B bus bar. Loosen the screws at the left end of the bars. 4. Use the top bar to connect the phase A to the phase B, as shown below. 5. Use the bottom bar to connect the phase B to the phase C, as shown below. 6. Tighten all screws to 40 inch/pounds of torque. 7. Replace dimmer modules. 8. Connect power to the A and C phase Cam-Loks. Do not connect power to the B phase Cam-Lok. Single phase operation is automatically detected by both the CEM and the MPE, so no additional configuration is necessary. Phase C Phase C Phase s wired for three phase operation Phase s wired for single phase operation Sensor Portable Pack User Manual 9

Input panel (MPE) s ❶ 0-10 Vdc analog input ❷ AMX192 input and pass-through ❸ DMX512 input and pass-through Input panel (CEM) s s s ❶ ETCLink input and pass-through ❷ DMX512 input and pass-through Input s Beacon Beacon The Sensor Portable Pack is available with two input panel options. Standard configuration packs are equipped with input and pass-through s for DMX512 and AMX192, as well as a single analog input. Advanced Features packs are equipped with DMX512 and ETCLink input and pass-through s. an SP12, each analog channel controls two dimmers. Analog channel 1 controls dimmers 1 and 13, channel 2 controls dimmers 2 and 14, and so forth. Note: Sensor electronics modules are somewhat interchangeable. The CEM will work in a standard pack, but it will not accept AMX192 or analog input. the other hand, an MPE will work in an AF pack, but it will not support Sensor s Advanced Features (AF) option. DMX512 and AMX192 termination switches are located next to their respective s. The termination switch on the last pack in the series must be in the ON position. switches on all other packs must be in their OFF positions. Analog 0-10 Vdc ❶ PUSH In AMX192 Out ETCLink ❷ PUSH PUSH Connector pinout information In DMX512 Thru ❸ PUSH In DMX512 Thru Note: You may use DMX512 and AMX192 inputs simultaneously or DMX512 and analog inputs simultaneously, but you may not use AMX192 and analog inputs simultaneously. ❶ ❷ PUSH DMX512 in AMX192 in XLR 5-pin male XLR 4-pin female DMX512 thru AMX192 thru XLR 5-pin female XLR 4-pin male Pin Signal Pin Signal 1... Common 1... Common 2... Data (-) 2... Clock (+) 3... Data (+) 3... Analog multiplex 4... Pass through 4... Clock (-) 5... Pass through Analog In D-sub 25-pin female Pin Signal 1-12... Signal 13-24... Not used 25... Common 10 Electronic Theatre Controls, Inc.

Beacon Door An LED status beacon is mounted in the top left corner of the pack s front panel. Under normal operating conditions, this beacon is illuminated. If the pack s electronics module senses an error condition in the pack, the beacon flashes until the error is corrected. In packs with the MPE, the beacon alerts you to run the MPE diagnostic routines to determine what the problem is. See the MPE User Manual for more information. In packs with the CEM, the beacon alerts you to check the CEM s LCD for error messages. See the CEM User Manual for more information. Each Sensor Portable Pack is equipped with a door that protects the dimmer modules and contains the cooling system s electrostatic air filter. To ensure proper cooling, always keep the door closed except when you are working on the pack. Sensor Portable Pack User Manual 11

Cooling system The Sensor Portable Pack is cooled by a fan located on the back panel. The pack s cooling fan draws air through the filter, over the surfaces of the modules and then blows it out the back of the pack. The fan runs when any of the dimmers in the pack are on. They continue to run for three minutes after all dimmers are off. Warning: Never obstruct the fan exhaust by placing objects that may block air flow behind your pack. For optimum performance, the average ambient temperature in an area where a Sensor Portable Pack is being used should be about 68 F (20 C). Under no circumstances should the ambient temperature be allowed to exceed 104 F (40 C). Air filter A door-mounted, electrostatic air filter removes dust and other airborne debris from the cooling air. This filter must be kept clean to ensure proper cooling. The filter should be cleaned every six months (more often in dirty locations). Follow these steps to clean the filter: 1. Open the door. 2. Brush or vacuum filter from both sides. 3. If a more thorough cleaning is necessary, use compressed air to blow out embedded dust and dirt. 4. Close the door. To remove air filter (for replacement or more thorough cleaning) follow these steps. 1. Open the door. 2. Use a Phillips-head screwdriver to remove the metal strip holding down the left side of the filter. 3. Remove filter from door. 4. Reverse procedure to replace filter. Specifications SP6 15 H x 17 W x 12 D Empty weight: 40 pounds Input power 80A, 120/208, 3Ø, 5-wire, 50/60HZ 120A, 120/240, 1Ø, 4-wire, 50/60HZ 10,000 Amps RMS @ 120/240 VAC SP12 24 H x 17 W x 12 D Empty weight: 68 pounds Input power 160A, 120/208, 3Ø, 5-wire, 50/60HZ 240A, 120/240, 1Ø, 4-wire, 50/60HZ 10,000 Amps RMS @ 120/240 VAC 12 Electronic Theatre Controls, Inc.