FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS. by John Michalak Romet International, Inc.

Similar documents
ADVANCED APPLICATION OF ROTARY METERS

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter PRODUCT FEATURES. Applications. Brief information. Operating Principle

NDM Rotary Gas Meter Installation and Operation Manual

RABO Rotary Gas Meter

ROOTS Meters Series B3 Meter Models 8C175-56M175

Elster RABO. Connected Industrial. Highly Accurate Rotary Gas Meter FEATURES & BENEFITS. Applications. Brief information

Installation and Maintenance Manual Series B3-HPC GE Meters

Fundamentals of Turbine Meters. Paul Honchar Sensus Metering Systems

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

Dresser * Series B3-HPC Rotary Meter

GTS, GTX and E-CLASS GAS TURBINE METERS SB

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

FUNDAMENTALS OF GAS TURBINE METERS Paul Honchar Sr. Product Manager Sensus 805 Liberty Boulevard DuBois, PA, USA 15801

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Series B3 ROOTS Meters Models:

cs200 series commercial / Industrial pressure reducing regulators

Series B3 ROOTS Meters Models:

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Installation and operation manual Series: imrm and imrm-twin

2.0 Burner Operating Parameters and Requirements

KleanLine Dry Gas Filters. Technical Bulletin

P200 Pressure Regulator

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

B42 Series Regulator Residential Regulator

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

P200 Pressure Regulator

627 Series Pressure Reducing Regulators

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

627 Series Pressure Reducing Regulators

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

P200 Pressure Regulator

To ensure proper installation, digital pictures with contact information to before startup.

Bray/McCannalok High Performance Butterfly Valves Technical Manual

T205VB Series Tank Blanketing Vacuum Breakers

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

ANDERSON GREENWOOD. Before installation these instructions must be fully read and understood.

627 Series Pressure Reducing Regulators

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

SECTION Pressure & Temperature Control

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

F300 Pressure Regulator

26 - COOLING SYSTEM CONTENTS ENGINE COOLING - DESCRIPTION... 3 ENGINE COOLING - OPERATION... 9 COOLING SYSTEM FAULTS... 1

Rosemount 1195 Integral Orifice Primary Element

FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems

SR100 Series Service Regulators. Technical Bulletin

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Describe the function of a hydraulic power unit

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

IOM Manual. IOM Manual. Series 76/77.

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Series PVP Variable Volume Piston Pumps

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Yarway Hy-Drop Throttling valve

Crispin Valves Operating Guide. Crispin

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

Installation Operation Maintenance

Industrial Turbo Meters, Sizes 2" through 6"

T205 Series Tank Blanketing Regulators

LIQUID MEASUREMENT STATION DESIGN Class No

GTS/GTX/E-Class Turbine Meters Installation, Operation and Maintenance

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Controls the destructive forces inherent in high pressure drop service through rapid energy dissipation.

Volumeter. RMG Meßtechnik GmbH. Publication No E

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

Troubleshooting, Service Tips, And Major Improvements For Hydrostatic Transmissions (Special Edition){3200}

RMG Meßtechnik GmbH. Publication No E

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 )

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

T205 Series Tank Blanketing Regulators

The 7100B Series is designed to protect low pressure storage tanks and systems from being overpressured. Introduction

BARTON 7400 Precision Gas Turbine Flow Meters

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Installation, Operation, and Maintenance Manual

A-PDF Split DEMO : Purchase from to remove the watermark

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

Signet 2517 Brass Paddlewheel Flow Sensor * *

Mark II and Mark IIE Turbo-Meters

VB VALVES & AUTOMATION

MODEL 200 MULTI-JET FLOW METER

Flow Computer Installation

Operating Manual. High Performance Vacuum Pump Models and 15600

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Series 100 Slam Shut Valve

SECTION METERS AND GAGES FOR HVAC PIPING

SPRING COLOR. Blue-black Black. Green-black Black Red-black Blue-black Green-black Green Orange. Red Red-black

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

type 630r relief Valve

ORIFICE PLATE flow meters

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

PETROL. Double Case PD Flowmeters. Trust in us Our Quality Counts. Technical Bulletin. PETROL Instruments S.r.l.

SERIES PC INSTRUCTION AND OPERATION MANUAL

Inline Pressure Control Or Shutoff Valves (Non-digital) And Bypass Pressure Control Or Shutoff Valves (Non-digital)

Transcription:

FUNDAMENTAL PRINCIPLES OF ROTARY GAS METERS by John Michalak Romet International, Inc. INTRODUCTION Rotary gas meters have been in use for over sixty years in the natural gas distribution industry. Over the years, the construction has switched from heavy cast iron bodies to lighter, high strength aluminum. Advances in manufacturing techniques such as CNC machining centers have enhanced the measurement performance of the rotary meter. Traditionally rotary meters are installed on applications requiring a flow capacity of 1,000 to 38,000 cfh. PRINCIPLES OF OPERATION Rotary gas meters measure the gas by positively displacing or capturing the gas in a measurement chamber. Gas entering the inlet of the rotary meter pressure body produces a differential pressure across the meter, which causes the two impellers to rotate. The timing gears synchronize the impellers to turn in opposing directions. Each rotation of the impellers measures four displaced volumes of the gas. of the custody transfer of gas are regulated and enforced by the gas regulatory departments in your area. METER TYPES Rotary gas meters are available in several pressure ratings and with a variety of module types to meet the diverse requirements of the gas industry. This paper will only address the most commonly installed rotary gas distribution system. These meters typically have a 175 psig or 12 bar MAOP and an ANSI 125 flange connection. Standard Counter Module The Standard Counter Module registers actual gas volume only and makes no adjustments or corrections to the readings. The Standard Counter Module is available in a side read (as shown) or end read configurations. The meter module converts the rotation of the impellers into standard noncompensated (NC) units of volume that, depending on the module type, may also convert the NC volume to standard base temperature and/or pressure conditions. This converted or compensated volume is what is used for the measurement of the custody transfer or billing of the gas. The related specifications for the measurement Temperature Compensated Counter (TC) Module Since the temperature of the natural gas may vary substantially from the base temperature (60 F or 15 C), the measurement of the custody transfer of natural gas is converted to a volumetric equivalent of this base temperature condition. The TC module measures the gas temperature with a bi-metallic probe and converts the non-compensated (NC) volume 1

mechanically through a combination of a temperature cam and striker lever assembly. Temperature Compensated Instrument Drive (TCID) Module Electronically Compensated Module (ECM2 ) Temperature compensated instrument drive meters convert the non-compensated volume to a volume converted to the base temperature (60 F or 15 C) condition and provide this compensation volume through the instrument drive. The instrument drive rotation provides a specific temperature compensated volume per rotation to the instrument. ACCURACY The electronically compensated module employs a solid-state sensor to sense the rotation of the impellers and produce a highresolution input (three pulses per impeller rotation) of the non-compensated (NC) metered gas volume. These volumetric input pulses are converted to the base temperature condition (60 F or 15 C), using the programmed routines in the microprocessor and the temperature value from the sensor, to perform the necessary calculations. A rotary meter provides accurate gas measurement over a wide range of flow rates within its rated capacity. The following graph illustrates the typical accuracy curve for a rotary meter. Instrument Drive (STD ID or DCID) Module Instrument drive meters permit the mounting of a variety of mechanical or electronic (electronic volume correctors) conversion devices. The instrument drive rotation provides a specific non-compensated volume per rotation to the instrument. CAPACITY The maximum rated capacity of a rotary gas meter (Q max) is marked on the meter. This rating is indicated in actual units of volume (acfh or am³/h) since rotary meters measure gas by positive displacement. Natural gas is measured in standard units of volume (scfh or sm³/h). The standard unit of volume is simply the volume of gas after being converted to the base conditions. The following formula is employed to correctly size a rotary meter to the flow requirement. Q max = Flow (scfh or sm³/h) / P F x T F Where the pressure factor P F is: 2

P F = Pressure Factor = (P ATM + P ACT ) / P BASE Where: P ATM = Atmospheric pressure (psia or abar) P ACT = Actual gas pressure (psia or abar) P BASE = Base pressure (psia or abar) T F = Temperature Factor = T ABS + T BASE / T ABS + T ACT Where: T ABS = 459.67 F or 273.15 C T BASE = 60 F or 15 C T ACT = Actual gas temperature F/ C Example The maximum flow requirement for a factory is 40,000 scfh at 40 psig. The peak load occurs in the wintertime when the average flowing temperature of the gas is 38 F. P F = (14.65 40) / 14.73 = 3.71 T F = 459.67 + 60 / 459.67 + 38 = 1.04 Q max = 40,000 / 3.71 x 1.04 = 10367 acfh Therefore, the recommended meter would be and RM11000 with a maximum flow capacity of 11,000 acfh. TESTING The verification of a rotary meter body is performed at two flow rates with an allowable error of ±1%. 95% ±5% of the meter capacity 20% ±5% of the meter capacity A bell prover determines the meter accuracy by comparing the known volume of the bell to the registered volume of the rotary meter. By measuring the travel of the bell, the volume being passed through the meter is determined and compared to the registered volume from the meter. A transfer prover verifies the test meter s accuracy by comparing the known volume passed through the master meter of the prover to the volume registered by the test meter. The flow for the prover is developed by a fan with a motor control to adjust the flow rate. If the rotary meter has a temperature conversion module, the accuracy of the module must also be verified. In the case of mechanical (TC) modules, the temperature conversion accuracy is verified at three temperatures (32, 60 & 86 F or 0, 15 & 30 C) for a specific test volume. Electronic temperature conversion modules (ECM2 ) require the verification of the temperature sensor accuracy at the above three test points and a temperature conversion test at only one temperature. In all of the tests, the allowable error is ±1%. GENERAL INSTALLATION PRACTICES FOR MECHANICAL AND ELECTRONIC ROTARY METERS Remember that a rotary meter represents a substantial cash register for a gas utility. Good installation practices are the key to obtaining the accurate gas measurement. Rotary gas meters can be installed in either a horizontal or vertical pipe. The recommended installation is in a vertical pipe to permit any contaminants in the gas to pass through the meter with the minimum of damage. The verification of the meter body accuracy is performed on certified prover system. The two main types of systems currently employed are: Bell Transfer 3

ROMET LTD. ROMET LTD. METER POSITIONS FROM TOP TO BOTTOM STANDARD VERTICAL FROM BOTTOM TO TOP REVERSED VERTICAL HORIZONTAL FROM LEFT TO RIGHT HORIZONTAL FROM RIGHT TO LEFT INCORRECT ROMET LTD. GROUND SURFACE GROUND SURFACE Meter Model RM1000-RM5000 6 15/16 RM7000-RM23000 9 11/16 RM30-RM140 176 mm RM200-RM650 246 mm INSTALLATION F L The manufacturer s recommended hardware specifications relating to the mounting flanges and flange bolts, washers and gaskets should be checked for compliance. *The dimension between the pipe flanges should equal the meter dimension plus two times gasket thickness. Install the rotary meter with full-face flange gaskets. Tighten the flange bolts to the manufacturer s recommended torque value. Install the meter oil supplied by the manufacturer as required: ½ way on sight glass. ROME T LTD. *Note: gasket thickness varies. GROUND SURFACE FIELD INSPECTION AND PRE- INSTALLATION PROCEDURE Prior to installing a rotary meter, inspect for any damage that may have occurred during transport to site. Remove the protective plugs from the inlet and outlet of the meter. Blowing into the meter will confirm that the impellers are rotating freely and without resistance. Ensure that the piping manifold of the meter station is free of foreign material (dirt, tap shavings, pipe dope, weld slag, etc.) and scale. Strainers and filters are recommended upstream of the meter to ensure gas quality. Check that the mounting flanges for the meter are level (within ±1/16 per foot or 5 mm per meter), parallel to each other and the correct F L distance apart (refer to the chart below). INLET METER PRESSURIZE THE METER Ensure all oil plugs (and any other connections) are properly tightened and secured before pressurizing the meter set. When the meter installation has been completed, the meter set should be pressurized SLOWLY (maximum 5 psig or 35 kpa per second) up to the allowable operating pressure specified to avoid overspeed or slamming of the meter. Should the installation be subject to sudden INSTANT ON-OFF loads, a properly sized restricting orifice or Venturi flow nozzle should be installed downstream of the meter to protect the meter from damage. Check for any gas leaks or other possible problems. After start up, the readout counter or drive should be running smoothly and in the correct direction when the required gas flow rate has been reached. METER FL INLET MAINTENANCE LEVEL LEVEL Under normal operating conditions, the oil should be inspected every 5-10 years and 4

changed or topped up as required. The change period will vary with the cleanliness of the gas being measured. 5

INSTRUMENTS AND ADAPTOR PLATES ON ROTARY METERS 1) The TCID/ID module is fitted with a universal mounting platform. The platform is stamped to confirm the front which must be oriented to the corrector and not the meter, regardless of the meter position. Due to the center line offset inherent to the design of the instrument, drive shaft alignment is necessary to ensure proper operation of the instrument and meter. Misalignment or incorrect mounting will result in periodic rotational binding. 2) The meter will function briefly and sometimes without an indication of a problem. Module failure is imminent. Drive pin Corrector properly mounted on platform Gasket Drain hole Mounting screws and washers (4) 3) If the drive pin located on the ID drive is not set to the instrument, the pin may bind against the mounting assembly, which creates downward force onto the bevel gears and ultimately, gear failure. 4) In the event of an instrument failure, (jamming) a direct or negative force is applied to the internal components of the module resulting in bevel gear and/or striker arm and clutch damage. 5) Ensure the gasket placement and sealing between the instrument to the platform. Periodic cleaning of the drain hole located under the instrument platform is recommended. 6) During the winter months, instruments have been found to freeze up due to moisture accumulating in the goose neck assembly. Although rare, this cause of module failure is more likely in the northern climates.