SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

Similar documents
TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

TX101/201 Insertion Turbine Instructions

TX100/200-SERIES INSERTION TURBINE. T X / S E R I E S I N S E R T I O N T U R B I N E instru c tions TX101/201 TX115/215

TX 115/215 Hot-tap Insertion Turbine Instructions

TX115/215 Hot-tap Insertion Turbine Instructions

TX101/201 Insertion Turbine Instructions

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

EX100/200 Series. Insertion Magnetic Flow Meter Instructions. EX11x EX21x. EX15x EX25x PROUDLY MADE IN THE USA

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

SeaMetrics Flow Meters and Flow Computers

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

TURBINE METERS - WP Series

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Signet 2517 Brass Paddlewheel Flow Sensor * *

FIXED DEPTH INSERTION METER INSTRUCTIONS

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

M SERIES Multi-Jet Cold Water Meter

Shop online at omega.com For latest product manuals: omegamanual.info

PSF50 Paddle flow switch

Hydro-Flow Model 2200 Installation and Operation Guide B

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

MODEL 1100 TURBINE FLOW METER

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Hydro-Flow Model 3100

Model 1100 Turbine Flow Meter

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Low Profile Insertion Vortex

LEVEL AND FLOW MEASUREMENT WS131 FLOW METER USER MANUAL.

Hot Tap Insertion Vortex

TURBINE FLOW METER SELECTION GUIDE

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

G2 Industrial Grade Meters

EZ-IN Series Turbine Flowmeter

BI-DIRECTIONAL INSERTION METER

Compu-Flow. Electromagnetic Insertion Flow Meter. Compu-Flow EXM MAG

EX800-Series. Electromagnetic Flow Sensor Instructions PROUDLY MADE IN THE USA

MFM220 & MFM220DC Plastic-Bodied Magmeter

Liquid Turbine Flowmeter

OVAL GEAR FLOWMETER ELECTRONIC MODEL 019 / ¾

flow measurement solutions RIM10 series rotor insertion flowmeters

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

G2 SERIES INDUSTRIAL GRADE METERS

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Positive Displacement Flowmeters GM020 series instruction manual

+GF+ SIGNET 2517 Adjustable Brass. Flow Sensor. Instruction Manual. Standard Sensor. Hot-Tap Sensor GEORGE FISCHER +GF+

Turbine Flow Meter Series Turbine Meter USER MANUAL

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

Series TTMP PVC Electronic Totalizing Meter

Chapter Page. 1 Introduction Description 1

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Model FVP General Specification. Flanged Vortex Plate. Product Features

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Warnings and Cautions. Precision Flow Insertion Mass Flow Meter. Instruction Manual BULLETIN F-41-PFS FR# R

VERIS FLOW MEASUREMENT GROUP

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

Vortex Plate. Model VP General Specification. Product Features

MODEL 200 MULTI-JET FLOW METER

TABLE OF CONTENTS GENERAL INFORMATION

C.W. COX COMPANY a product line of Perfecto Products, Inc

FPD1001B thru FPD1003B, FPD1102B and FPD1103B, FPD1201B thru FPD1203B SERIES LOW FLOW Positive Displacement Flowmeters

ZDM Positive Displacement Flow Meter User Instructions

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Signet 2552 Metal Magmeter

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Positive Displacement Flowmeters GM007 series instruction manual

Positive Displacement Flowmeters GM020 series instruction manual

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

INSTALLATION AND OPERATION

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

Appendix. Clearance. Skewed profiles. Application Schematics

TURBINE FLOW METER Installation and Operation Guide

MODEL 900 IMPELLER-TYPE FLOW METER

Signet 2552 Metal Magmeter

User s Guide FP-2540/FP Flow Sensors. Shop online at omega.com SM For latest product manuals:

Transcription:

F- SERIES INSERTION TURBINE instructions -0XX -1XX

Table of Contents GENERAL INFORMATION General Information Features, Specifications... Page 1 Installation Piping, Immersion, Positioning the Meter... Page 2 Straight Pipe Recommendations...Page 3 Full Pipe Recommendations... Page 4 Fitting Installation, Meter Installation... Page 5 Proper Depth Setting, Dimension C, Pipe Wall Thickness... Page 6 Set-Up Connection, Calibration, K-Factors... Page 7 Operation Flow Range, Flow Rates... Page 8 Parts List Parts Exploded View... Page 9 Troubleshooting & Repair Troubleshooting, Repair, Rotor Replacement... Back TableS AND DIAGRAMS The Series is an adjustable depth insertion turbine that comes in brass or 316 stainless models to fit 3 to 40 pipe. Installation fittings are standard 1-1/2" (-XSX Models) or 2 (-XLX Models) male NPT. Fittings such as saddles and weldolets may be purchased either locally or from Dwyer Instruments Inc. Please see Series SDF. Ruby bearings and a non-drag pickoff give these adjustable insertion turbine flow sensors a wide flow range and long life. A sensor detects the passage of miniature magnets in the rotor blades. The resulting square-wave signal can be sent for hundreds of feet without a transmitter, over unshielded cable. This signal can be connected directly to many PLC s and other controls without any additional electronics. FEATURES 3/4 diameter tubing for low insertion force 2 Adapter removes to mount hot-tap machine Full-port 2 ball valve for sensor removal Adapter fitting with 2 NPT threads Locking collar If desired, a modular system of electronics can be installed directly on the flow sensor or mounted remotely. The Series RTI (loop powered) provides digital rate and total display, as well as programmable pulse. The Series RTI also provides a 4 to 20 ma analog output. The BAT is a blind analog (4 to 20 ma) transmitter. Programmable pulse for pump pacing is available with the PWD. The hot-tap models can be installed or serviced without shutting down the line by means of a 2 full-port isolation valve that comes with a nipple for installation on the pipe fitting. In most circumstances, no special tool is required. Modular electronics (optional) rate/total/pulse/4-20 ma (Series RTI) blind 4-20 transmitter (Series BAT) 18 Foot Cable Rugged cast aluminum housing Compression nut for easy adjustment, secure locking Adapter fitting with 1-1/2 NPT threads -1XX Features... Page 1 Specifications... Page 1 Positioning the Meter... Page 2 SPECIFICATIONS* Rotor housing Removable jewel bearings Rotor -0XX Piping... Page 2 Straight Pipe Recommendations... Page 3 Full Pipe Recommendations... Page 4 Meter Installation... Page 5 Depth Setting... Page 6 Pipe Wall Thickness... Page 6 Connection Diagram... Page 7 Parts Exploded View... Page 9 Parts List... Page 9 Power Sensor Pipe Size Materials Fitting Size Flow Range Accuracy Supply Voltage Current Type Output Sinking Current External Pull-up Resistor Housing Sensor Body Rotor Shaft/Bearings Isolation Valve 6-40 Vdc < 2 ma Magnetoresistive Current Sinking Pulse 100 ma max 3 to 40 Vdc -S Model -L Model 3-12 (50-300mm) 12-40 (300-890mm) Cast aluminum Brass or 316 SS PVDF standard Nickel-bound tungsten carbide/ruby -0-1 None Bronze (316SS optional) 1-1/2 NPT 2 NPT 0.5-30 feet/sec (0.15-9.14 meter/sec) +/-1.5% of full-scale Note: For larger pipe sizes contact Dwyer Rotor Replacement...B ack Maximum Temperature Maximum Pressure 200 F (93 C) 200 psi (14 bar) Insertion Force 0.44 x pressure in pipe Cable #22 AWG 3-con, 18 (6m); 2,000 (650m) maximum cable run *Specifications subject to change. Page 1

INSTALLATION INSTALLATION An insertion flow sensor measures the velocity of flow at one point in the pipe; flow rate and total can be inferred from this one point. Accuracy is decreased by any factor which makes the flow at the measured point unrepresentative of the entire flow stream. This includes distorted flow patterns caused by upstream fittings too close to the sensor. The worst offenders are fittings that increase the flow on one side of the pipe, such as partially-opened gate or butterfly valves. Fluid moving in a pipe does not flow at the same velocity. Toward the center of the pipe, fluid moves faster than at the wall, and the relationship between the two changes as overall flow rate increases. This change in the velocity profile can result in non-linearity, which means that the K-factor that is correct for one flow rate may be incorrect for another. Recommended depth settings (see page 6) have been carefully chosen to minimize this source of error, and should be followed carefully, especially in the smaller pipe sizes. Piping. For best results, the sensor should be installed with at least ten diameters of straight pipe upstream and five downstream. Certain extreme situations such as partially-opened valves are particularly difficult and may require more straight diameters upstream. See Straight Pipe and Full Pipe recommendations on following pages. may experience occasional temporary immersion, as in a flooded vault, a unit modified for immersion should be specified (Option -IMM). Positioning the Meter. Horizontal is the preferred installation orientation, since it improves low-flow performance slightly and avoids problems with trapped air. Bottom, top, and vertical pipe installations are all acceptable if required by the piping layout. Fair (unacceptable if air is present) Best Fair (unacceptable if fluid contains sediment) STRAIGHT PIPE RECOMMENDATIONS (X = diameter) 10X Reduced Pipe Two Elbows In Plane Two Elbows, Out Of Plane 10X 20X Immersion. The Series standard sensors are not designed for continuous underwater operation. If your meter CAUTION: These water meters are not recommended for installation downstream of the boiler feedwater pump where installation fault may expose the meter to boiler pressure and temperature. Maximum recommended temperature is 200ºF. Expanded Pipe 20X 30X Spiral Flow Propeller Meter 50X Page 2 Page 3 Swirling Flow Partially Open Butterfly Valve

INSTALLATION INSTALLATION FULL PIPE RECOMMENDATIONS -0XX INSTALLATION Possible Problem Better Installation Ensures full pipe Fitting Installation. -0XX sensors come with a 1-1/2 male NPT pipe thread adapter fitting. Any fitting that provides the matching NPT female thread may be used. (For comparable saddle fitting please see Series SDF.) Installation procedure compensates for fitting height differences. Cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. Compression nut Allows air pockets to form at sensor Possible Problem Better Installation Meter Installation. Loosen the compression nut so that the adapter slides freely. Pull the meter fully upward and finger-tighten the compression nut. Using a thread sealant, install the adapter in the pipe fitting. Do not overtighten. Loosen the compression nut and lower the meter to the appropriate depth setting (see diagram and instructions that follow). Caution: Do not allow the meter to fall into the pipe uncontrolled, as this may damage the meter. Be sure flow is in the direction of the arrow on the housing. Tighten compression nut fully. -1XX INSTALLATION Adapter fitting with standard 1-1/2" NPT threads -0XX Hot-tap meters are designed to be installed and serviced without depressurizing the pipe. Compression nut Post-valve cavitation can create air pocket Keeps pipe full at sensor Fitting Installation. The hot-tap sensors have a 2 male NPT thread for compatibility with the 2 isolation valve. Any fitting that provides matching NPT female thread may be used. The installation procedure compensates for differences in fitting height. Locking collar 2 adapter removes to mount hot-tap machine Possible Problem Better Installation If initial installation is performed on an unpressurized pipe, cut a minimum 1-3/4 hole in the pipe. If possible, measure the wall thickness and write it down for use in depth setting. Then install the threaded fitting (saddle, weldolet, etc.) on the pipe. (Such as the Series SDF.) If it is necessary to do the initial installation under pressure, any standard hot-tap drilling machine with 2 NPT adapter, such as a Transmate or a Mueller, can be used. Ordinarily, it is not necessary to use an installation tool, since the small-diameter tube can be controlled by hand but should be used for higher pressures. Full-port 2 ball valve allows sensor removal Standard 2 NPT threads Page 4 Air can be trapped Allows air to bleed off Meter Installation. Remove the sensor unit from the valve assembly. Using a thread sealant, install the valve assembly on the pipe fitting. If the initial installation is a pressure ( hot-tap"), remove the 1-1/2 x 2 adapter bushing at the back of the valve. Thread the tapping machine on, open the valve, and tap using a minimum of 1-3/4 or maximum 1-7/8 cutter. After retracting the machine and closing the valve, reinstall the flow sensor. When the sensor is secure, open the valve and adjust depth setting (see diagram and instructions that follow). Be sure flow is in the direction of the arrow on the housing. Tighten locking collar and compression nut fully. -1XX Sensor Removal Page 5

INSTALLATION SET-UP Table 1: Dimension "C" Proper Depth Setting. It is important for accuracy that the sensor be inserted to the correct depth into the pipe. 1. In Table 1, find Dimension C for your sensor model and pipe size. Subtract wall thickness of your pipe (Table 2) to calculate Dimension D. 2. Measuring from the outside of the pipe to the joint in the housing, as shown in the diagram on the left, adjust the sensor to Dimension D and hand-tighten compression nut. 3. Align the conduit housing with the centerline of the pipe, as shown. Be sure the arrow on the housing points in the direction of flow. strain relief FLOW 4. Check Dimension D one more time. 5. Tighten the compression nut fully. Calibration ( K-Factor ). In order to properly process pulses from the flow sensor, a number must be entered into the control to which the sensor is connected. This number, called the K- factor, is the number of pulses the sensor puts out per unit of fluid passing through the pipe. It is normally provided for Dwyer sensors in pulses per gallon (see Table 3 below). These numbers are based on extensive testing, which has shown close agreement between different sensors in the same installation. Most K-factor error can be attributed to installation variables, such as depth setting and fitting configuration. It is possible to field calibrate a sensor by catching the fluid in a measured container and comparing with the number of pulses recorded. (To record individual pulses, set the K-factor on the control to 1.00.) This is especially desirable if the installation has less than the recommended length of straight pipe upstream of the sensor. For detailed intructions on field calibration, please contact Dwyer Instruments Inc. Connection. Sensors are supplied with 18 ft. of cable. For sensors with no additional electronics, see diagram for color coding. For sensors with on-board electronics, see the manual accompanying the electronics module. Nominal Pipe Size -0-S -0-L -1-S -1-L Table 2: Pipe Wall Thickness NOMINAL Pipe Size 3 4 6 8 10 12 14 16 18 20 24 30 36 Sch. 40 Sch. 80 Stainless Steel (10S) Stainless Steel (40S) 3 4 6 8 10 12 14 16 18 20 24 30 36 9.16 9.08 8.99 8.82 8.48 8.14 7.80 7.46 6.78 - - - - 14.16 14.08 13.99 13.82 13.48 13.14 12.80 12.46 11.78 10.42 9.40 9.38-16.00 15.80 15.70 15.50 15.10 14.80 14.50 13.80 - - - - - 19.95 19.85 19.65 19.45 19.15 18.85 18.45 17.75 16.45 15.45 14.35 - - 0.216 0.237 0.280 0.322 0.365 0.406 0.438 0.500 0.562 0.593 0.687 0.300 0.337 0.432 0.500 0.593 0.687 0.750 0.843 0.937 1.031 1.218 0.120 0.120 0.134 0.148 0.165 0.180 0.188 0.188 0.188 0.218 0.250 0.312 0.312 0.216 0.237 0.280 0.322 0.365 0.375 0.375 0.375 0.375 0.375 0.375 0.375 0.375 TABLE 3: TX100/200 K-factors (in Pulses/Gallon) for various pipe sizes Nominal Pipe Size 3 4 6 8 10 12 14 16 18 20 24 30 36 Sch. 40 12.067 7.049 2.949 1.690 1.033 0.694 0.575 0.465 0.391 0.326 0.220 - - Sch. 40 13.506 7.917 3.293 1.845 1.150 0.772 0.631 0.498 0.419 0.354 0.419 - - Stainless Steel (10S) 10.688 6.160 2.663 1.551 0.944 0.642 0.538 0.439 0.364 0.303 0.199 0.127 0.088 Stainless Steel (40S) 12.067 7.049 2.949 1.690 1.033 0.687 0.565 0.455 0.377 0.313 0.204 0.128 0.088 (Type K) 13.441 7.777 3.317 1.865 1.181 0.781 - - - - - - - (Type L) 13.097 7.564 3.193 1.800 1.133 0.744 - - - - - - - Copper Pipe 12.115 7.156 2.886 1.682 1.033 0.684 - - - - - - - Duct Iron (Class 52) 9.974 6.301 2.734 1.528 0.948 0.635 0.487 0.401 0.330 0.269 0.177 0.114 0.079 (Type L) (Type K) Brass Pipe Duct. Iron (Class 52) 0.090 0.110 0.140 0.200 0.250 0.280 0.109 0.134 0.192 0.271 0.338 0.405 0.219 0.250 0.250 0.312 0.365 0.375 0.280 0.290 0.310 0.330 0.350 0.370 0.390 0.400 0.410 0.420 0.440 0.470 0.530 Record Your Settings Once you have the meter set up and operational, it is important to record your meter setttings and save them for future reference. K-Factor Insertion Depth (Dim. D) Page 6 Page 7

OPERATION PARTS LIST Flow Range. These sensors are designed to operate at flow velocities of 0.5 to 30 feet per second (see Table 2, below). If erratic readings are encountered at low flows, check the chart to see if flow is below minimum for the pipe size. The standard shaft and bearings should have a long life at continuous high flow. -0XX TX101/201-0XX Parts 1 Upper housing assembly 2 Housing Gasket TABLE 4: Flow Rates converted from Feet/Sec to Gallons/Minute at various velocities: Schedule 40 pipe Feet / Sec Nominal pipe size 3" 4" 6" 8" 10" 12" 16" 24" 30" 36" 38" 40" 3 Lower housing 4 Housing screw assembly 5 Plug, steel (0.5) 11.5 19.8 45 78 123 176 313 704 1100 1585 1770 1960 6 Strain relief (1.0) 23 39.7 90 156 246 349 551 1250 2200 2910 3530 3915 7 Sensor w/cable 8 Tube (2.0) 46.1 79.4 180 312 492 698 1100 2510 4401 5830 7070 7825 9 Compression nut (5.0) 115 198 450 780 1230 1740 2750 6270 11002 14570 17670 19560 TX115/215-1XX 10 Compression Ferrule 11 Adapter fitting (10.0) 230 397 900 1560 2460 3490 5510 12530 22005 29140 35350 39120 12 Rotor housing O-ring (20.0) 461 794 1800 3120 4920 6980 11020 25060 44010 58270 70700 78240 13 Rotor housing (30.0) 691 1190 2700 4680 7370 10470 16520 37600 66015 87410 106050 117500 14 Jewel bearing assembly (for carbide shaft) 15 Turbine Rotor assembly 16 Rotor repair kit (consists of #14 & #15) -1XX Parts (hot-tap) All part numbers are the same except those 17 Locking Collar below 18 Adapter fitting O-ring 19 Adapter, hot tap 20 Valve assembly (inlcudes Adapter, #20) Page 8 Page 9

TROUBLESHOOTING and REPAIR Troubleshooting Caution! Never attempt to remove a flow sensor when there is pressure in the pipe. Loosen the compression nut slowly to release any trapped pressure. If fluid sprays out when removing the sensor, stop turning and depressurize the pipe. Failure to do so could result in the sensor being thrown from the pipe, resulting in damage or serious injury. The flow sensor has only one moving part, the rotor. If this is turning properly and there is no signal, the Hall-effect sensor is not operating properly. To check the signal, apply 12 VDC regulated* power to the red (+) and black (-) leads. Set a multimeter to voltage reading. Put the positive multimeter lead on the red wire and the negative lead on the white wire. Slowly turn the rotor. Voltage reading should swing between +12 Volts and 0 Volts as the rotor turns. If it does not, the Hall effect sensor is not working properly. Checking for continuity is not a useful test of these sensors. *NOTE: An unregulated power supply can exceed max voltage of micro powered sensor (gray cable) and damage sensor. Rotor Replacement. Rotors are easily field-replaced. Shaft and rotor are a single unit, and are not replaced separately. If replacement is due only to normal shaft wear, bearing replacement is probably not necessary. If the rotor has been damaged by impact, the bearings should also be replaced. Rotor and bearings can be ordered as a kit (see parts listing). Follow these steps: 1. Unscrew the threaded bearing housings to expose the shaft ends. If bearings are being replaced, back them completely out. 2. Remove the rotor. Put the new rotor in its place. 3. Thread in one bearing housing part way, then the other. Take care to start the end of the shaft into the bearing hole before tightening further. 4. Screw in bearing housings until they bottom. Note: Do not use excessive force. 5. Check for free spin. Blowing lightly on the rotor should result in it spinning rapidly and coasting to a smooth stop. Turbine Rotor WARRANTY/RETURN Refer to "Terms and Conditions of Sale" in our catalog or on our website. Contact customer service to receive a Returns Goods Authorization number before shipping your product back for repair. Be sure to include a brief description of the problem plus any relevant applciation notes. Shaft Bearing Housing Dwyer Instruments, Inc. 102 Indiana Highway 212 Michigan City, IN 46360 USA (P) 219.879.8868 (F) 219.872.9057 1.800.872.9141 www.dwyer-inst.com PL-OM-65200391-091912 9/19/12