FUJI FRENIC INVERTER USER GUIDE

Similar documents
USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Starting guide FRENIC-Lift

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

LIFT INVERTER SERIES L1000A

Expanding Application of FRENIC-Lift Series for Elevators

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

LIFT INVERTER SERIES L1000A

VFD E Series. Features

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

Overvoltage Suppression F7 Drive Software Technical Manual

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

DE ES A A. For Modernisation and New Installation L1000A L1000A L1000A

SMS PRODUCT CATALOGUE

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

GS2 Series - Introduction

Troubleshooting. YASKAWA ELECTRIC SIEP C D YASKAWA AC Drive A1000 Technical Manual 301

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Fuji Electric High Performance Compact Inverter. Single-phase 200 V kw Three-phase 400 V kw

Application Note CTAN #234

MRL Manual Control box with Yaskawa L1000

DYNEO Synchronous motors with permanent magnets-drive Commissioning

J1000 D E F I 1000 J1000 J1000 J1000 J1000

HIDRA CRONO Controller VVVF Control Techniques Unidrive SP (Asynchronous motors)

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Addendum to Instruction Manual GP10 and VG10

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

ADJUSTABLE FREQUENCY CRANE CONTROLS

SYSDrive Frequency Inverter

C2000 driving IM with TQC+PG

Electronic Ballast EVG 2000-T

VSD Series II Variable Speed Micro Drives

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Description 1/8-7.5HP

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

AC Drive for Elevator

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Technical Information

Technical Explanation for Inverters

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Delta Products VFD CP2000 Bypass Control Packages.

ALTIVAR 58 AC Drives


SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Unidrive M700 Class leading performance with onboard real-time Ethernet

L300P Inverter Specifications

YASKAWA AC Drive A1000

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

TRIPS AND FAULT FINDING

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

3 Year. Warranty. Maximum Engineering for Global Advantage. The High Performance Multifunctional Inverter CEN-G1EN18.05

Experience & Innovation

Introduction The aim of this application note is to outline how to configure an ACSM1 drive to run with an ABB BSM series AC servo motor.

Quick Start Guide of CV50- ControlVIT Series

General Specifications

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

OPERATING INSTRUCTIONS FOR SLIDING DOOR RETROFIT CONTROLLER DC-02

LIFT INVERTER SERIES L1000A

L1000A. Lift Inverter Drives.

Magnetek DSD 412 Drive

Issue 2.0 December EPAS Midi User Manual EPAS35

SINAMICS GM150 IGCT version

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

MAGPOWR Spyder-Plus-S1 Tension Control

PowerView PV380-R2 Mechanical Configuration

New. High Performance Inverter FUJI INVERTERS 24A1-E-0042

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Closed Loop Stepper Systems

Shenzhen Sine Electric Co., Ltd.

Frequency Inverters SJ Series Type P1

ECONOMISER SERIES E2T USER MANUAL

HIGH POWER SOLENOID DRIVER 1

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

J1000. Compact Inverter Series.

HVAC Products. Introducing the SED2 Variable Frequency Drives

High-Efficiency AR Series. RK Series /0.72 /Geared. CRK Series. RBK Series. CMK Series. 2-Phase Stepping Motors A-278.

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Combined Ventilation Controller RVWS-T-224HA

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Stepping Motor and Driver Package. High-Efficiency AR Series. DC Power-Supply Input. Built-in Controller Type Pulse Input Type

Motorized Cylinders. EZC Series. Stroke 150 mm

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

EZS. Motorized Linear Slides. Series. RoHS-Compliant

APPLICATION GUIDE. Pure easiness for a wide range of applications ACS580 general purpose drives

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

PLEASE COMPLETE AND RETURN AS SOON AS POSSIBLE

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

YASKAWA AC Drive V1000. YASKAWA AC Drive V1000

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Hybrid Control System, Alpha Step

Sliding doors / fire doors

Transcription:

International Lift Equipment Ltd : Fuji Frenic Lift Manual Page 1 INTERNATIAL LIFT EQUIPMENT LTD FUJI FRENIC INVERTER USER GUIDE FM 40432

Page 2 Contents Drive overview... 4 Keypad operation... 5 Keypad operation... 6 Keypad menus... 6 0 QUICK SET... 6 1 DATA SET... 6 2 DATA CHECK... 6 3 OPR MNTR (OPERATI MITOR)... 6 4 I/O CHECK... 7 5 MAINTENANC (MAINTENANCE)... 7 6 ALM INF (ALARM INFORMATI)... 7 7 ALM CAUSE (ALARM CAUSE)... 7 8 DATA COPY... 7 9 LOAD FCTR (LOAD FACTOR)... 7 Example of parameter setting... 8 Encoder connections... 9 Standard (Built-in) input connection for 12V/15V incremental encoder... 9 Option card OPC-LM1-PR for synchronous motors... 9 Option card OPC-LM1-PS1 for synchronous motors... 10 Getting running for the first time and auto tuning... 12 Open loop operation... 12 Closed loop operation... 12 Gearless machines (permanent magnet)... 13 Final setting prior to running for the first time.... 14 Setting speeds, acceleration, deceleration and jerks for High speed... 14 S curve for high speed (HS on Skycom Solo, HS or DTS on Skycom)... 14 Setting speeds, acceleration, deceleration and jerks for medium speed... 15 S curve for medium speed (MS1 on Skycom)... 15 Setting speeds, acceleration, deceleration and jerks for reduced power mode... 15 S curve for reduced power mode (RPR on Skycom / Skycom Solo)... 15 Inspection speed... 16 Performance related settings... 17 Brake lift / release timers... 17 Critical settings for open loop... 17 No load current (parameter P06)... 17 Slip frequency (parameter P12)... 17 Slip compensation gains (parameter P09 for driving, P10 for braking)... 18 Gains (closed loop and Gearless)... 18 Anti roll back parameters (gearless only)... 18 Brake Checking Signal for UCM Compliance (EN81-1 + A3)... 19 Introduction... 19 Description of the function and parameters... 19 Function Behavior... 20 Brake feedback is abnormal at starting... 20 Brake feedback is abnormal at stopping... 21 Brake feedback is abnormal during travel (with BBE trip)... 21

Page 3 Brake feedback is abnormal during travel (no BBE trip)... 22 Brake feedback is abnormal when the lift is stationary... 22 Test of BRKE1 Function at start... 23 Test of BRKE1 function during travel... 24 Test of BRKE2 Function at start... 25 Test of BRKE2 function during travel... 26 Fault codes and their meanings... 27 bbe Reset procedure... 28 Document History... 28

Page 4 Drive overview FUJI FRENIC Lift series inverters is specially designed for operation of induction and permanent magnet synchronous motors used in lift applications. Also induction motors without encoder (open loop) can be controlled obtaining good performance and high positioning accuracy at stop. The main characteristics of FUJI FRENIC Lift are: Compact dimensions with high output power Rescue operation possible with Battery or UPS with indication of recommended direction Short floor operation with distance based control 200% overload for 10 Seconds Incremental encoder input (12V or 15V / Open Collector) Optional cards for different encoder types (EnDat 2.1, SinCos...) Pole tuning and Auto tuning without removing the ropes Multifunctional, detachable keypad Braking transistor is integrated in all capacities Operation of Induction motor without encoder (open loop) Different S curves and accel/decel profiles for all speed inputs (medium and reduced power speeds) High switching frequency for reduced motor noise (15Khz standard) Conformity to European standards The CE marking on Fuji Electric products indicates that they comply with the essential requirements of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC issued by the Council of the European Communities and the Low Voltage Directive 73/23/EEC. Inverters with built-in EMC filter that bear a CE marking are in conformity with EMC directives. Inverters having no built-in EMC filter can be in conformity with EMC directives if an optional EMC compliant filter is connected to them. General purpose inverters are subject to the regulations set forth by the Low Voltage Directive in the EU. Fuji Electric declares the inverters bearing a CE marking are compliant with the Low Voltage Directive. FRENIC Lift inverters are in accordance with the regulations of following council directives and their amendments: EMC Directive 2004/108/EC (Electromagnetic Compatibility) Low Voltage Directive 2006/95/EC (LVD) For assessment of conformity the following relevant standards have been taken into consideration: EN61800-3:2004 EN50178:1997 The FRENIC- Lift inverters are categorized as category C2 according to EN61800-3:2004. When you use these products in the domestic environment, you may need to take appropriate countermeasures to reduce or eliminate any noise emitted from these products.

Page 5 Keypad operation To operate, commission and Set up FRENIC Lift inverter there are two possibilities: using inverter keypad or PC. For operation using a PC it is necessary to use the dedicated software Lift Loader. This software is free of charge and can be downloaded from our website www.ileweb.co.uk (a USB to RS485 converter is required) The keypad is connected to the inverter through the RJ-45 connector. This connection is also used for the connection with the PC or the lift controller using DCP 3 protocol LED-display shows the operation values, for example Set point frequency, actual frequency or alarm codes. Displays the actual used multipliers and/or units used in the LEDdisplay. The actual units will be indicated by a line below the unit s indicator. LCD-display for showing different information, like operation status, functions values. The lowest line shoes information regarding keypad operation. a) Shows the actual operation status like FWD=UP, REV=DOWN or Stop = Standstill. b) Shows the actual operation mode Terminal operation = REM or via DCP=COMM Keys: With these keys displayed values can be set or function values can be changed. Status Led shows inverter status. Figure 12: Overview of keypad Keys explanation: Use this key to change between operation and programming mode. Use this key to move the cursor to the right in programming mode In Alarm mode: Alarm reset In Programming mode: leave the parameter changing in the settings In Programming mode: Function selection inside the menu or change the function value In Programming mode: Scroll to the next parameter In Programming mode: Parameter edit or saving In Operation mode: for choosing the displayed value (and units) Change between Remote (Terminal control) and Local (keypad operation) These 3 keys may not be used in lift application. In local mode with these keys the motor can be started and/or stopped.

Page 6 Keypad operation Keypad menus The complete menu list can be accessed by pressing the PRG key. The LCD display shows the 4 first menus from the complete list. 0. QUICK SET 1. DATA SET 2. DATA CHECK 3. OPR MNTR 4. I/O CHECK 5. MAINTENANCE 6. ALM INF 7. ALM CAUSE 8. DATA COPY 9. LOAD FCTR Figure 1: Complete menus list Detailed menus description 0 QUICK SET This menu contains all of the parameters required for set up and commissioning of the Frenic inverter specific to ILE installations. The parameters in this menu will allow all the motor data to be set, all autotune functions and all S curve settings. After selecting a parameter it can be checked and/or changed (edited) if needed by pressing key. 1 DATA SET This menu is used for accessing all parameters. It displays the function codes list and describes the function of that code. Every function has a number and name assigned. After selecting a function it can be checked and/or changed (edited) if needed by pressing key. 2 DATA CHECK Also using this menu parameters can be changed. In this menu only function codes and parameter values are shown (without the names) and the set values can be directly read. Parameter values changed from default are indicated by a star on the right side of the parameter number. By pressing key the selected function can be changed. Figure 2: DATA CHECK menu. Function changed and saved 00,00 P01 4 P02* 11kW P03 20A P04 0 3 OPR MNTR (OPERATI MITOR) In this menu different operating values can be shown in the LCD display. There are 4 different screens showing 4 lines each, for example output frequency, output current, output voltage and calculated torque.

Page 7 4 I/O CHECK Used for checking the I/O status and if FRENIC Lift is receiving the correct control signals from the ILE controller and the output signals are being issued correctly. Input and output signals are displayed in different screens. Figure 3: Example with digital inputs displayed. In this Example X2 and FWD inputs are active. 00,00 TRM X2 X6 FWD X3 X7 REV X4 X8 X1 X5 EN 5 MAINTENANC (MAINTENANCE) Shows the inverter condition: runtime, main capacitors capacitance, firmware version. 6 ALM INF (ALARM INFORMATI) In this menu the alarm memory is shown. After the selection of an alarm by pressing key the most relevant information of each alarm is shown. 7 ALM CAUSE (ALARM CAUSE) In this menu the possible alarm causes are shown. After the selection of an alarm by pressing key a possible cause of this alarm is shown. 8 DATA COPY With this menu the complete inverter parameter set can be saved to the keypad and transfered from one inverter to another. This may be helpful to set up different installations with the same motor and same characteristics. Be aware that function protection (F00) is no copied. Motor data and communication set are copied only between inverters of same range. 9 LOAD FCTR (LOAD FACTOR) In this menu the maximum current, the average current and the average braking torque during a preset measuring time can be measured in the real application.

Page 8 Example of parameter setting Figure 4: LCD display of the first 4 menus after pressing PRG key 00,00 1. DATA SET 2. DATA CHECK 3. OPR MNTR 4. I/O CHECK Figure 5: Menu selection (in this figure maintenance menu is selected) 00,00 2. DATA CHECK 3. OPR MNTR 4. I/O CHECK 5. MAINTENANC Figure 6: Selection of Menu 1 00,00 1.DATA SET 2.DATA CHECK 3.OPR MNTR 4.I/O CHECK Figure 7: Function code selection. In this figure P03 Rated current from the P Group (Motor functions) 00,00 P01 M-POLES P02 M- CAP P03 M- Ir P04 M- TUN Figure 8: To edit (go inside) the function Figure 9: Changing the value of P03 (motor rated current), in this example to 12. 00,00 P03 M-Ir 12 A 0.00~500.00 Actual value Setting range 00,00 P03 M-Ir 12 A 0.00~500.00 After changing the value using the arrow keys, it can be saved by pressing key. Exiting a parameter without saving is possible by pressing the key.

Page 9 Encoder connections Standard (Built-in) input connection for 12V/15V incremental encoder The FRENIC Lift control board includes an interface for the connection of an encoder for applications with induction motors. The connection is via screw terminals. The output supply voltage is 12 or 15VDC and is compatible with standard HTL 10-30VDC encoders. Pulse resolution from 360 to 6000 can be set using function L02. Supply voltage The supply voltage of the encoder can be selected by setting the slide switch SW5 located on the inverter control board. The default setting is 12V, which can be used for standard encoders with supply voltages from 10 to 30 VDC. FRENIC Lift Term1 PAO PBO Term6 Built-in HTL - Interface PO CM PA PB PZ Maximum 20m cable length Output encoder signal Open collector output -max. 27VDC, 50mA- level: 2V or less Common terminal CM to be connected to the lift controller (shaft copy) Incremental Encoder HTL Figure 10: Connection using HTL encoder interface $ The encoder cable must always be shielded. The shield must be connected at the inverter and the encoder end using the ground terminal or dedicated terminal. Option card OPC-LM1-PR for synchronous motors For permanent magnet synchronous motors For encoder Heidenhain Type ERN1387 or ERN487 or compatible Output signal: 2048 Sin/Cos pulses (periods) per revolution Operating supply voltage: 5VDC±5% (maximum current is 300 ma) Absolute signal: 1 Sin/Cos signal with 1 Period/turn

Page 10 FRENIC Lift OPC-LM1-PR PO PO CM CM CM PA+ PA- PB+ PB- PC+ PC- PD+ PD- CM FPA FPB Maximum cable length 5m Maximum cable length 20m Heidenhain ERN1387 Output encoder signal Open collector output -max. 27VDC, 50mA- level: 2V or less to be connected to the lift controller (shaft copy) Figure 11: Connection option card OPC-LM1-PR Table 1: Connection description of terminals for OPC-LM1-PR Terminal description in the option card Signal name from Heidenhain Description P0 Up und Up Sensor Supply voltage 5V, connection of Up Sensor mandatory for cable length >10m CM 0V (Up) und 0V Sensor Common 0 V for the power supply PA+ A+ A phase PA- A- A phase inverted PB+ B+ B phase PB- B- B phase inverted PC+ C+ C phase (Absolute signal) PC-- C- C phase inverted (Absolute signal) PD+ D+ D phase (Absolute signal) PD- D- D phase inverted (Absolute signal) $ Prior to the commissioning, the encoder resolution (pulses per revolution) has to be set using parameter L02. $ For synchronous motors it is also necessary to set the encoder type in function L01. Option card OPC-LM1-PS1 for synchronous motors For permanent magnet synchronous motors For encoder Heidenhain Type ECN1313 or ECN413 or ECN113 Output signal: 2048 Sin/Cos pulses (periods) per revolution Operating voltage: 5VDC±5%; 300mA Data connection: EnDat 2.1

Page 11 FRENIC Lift OPC-LM1-PS1 PO PO CM CM CM PA+ PA- PB+ PB- CK+ CK- DT+ DT- CM FPA FPB Maximum cable length 5m Maximum cable length 20m Heidenhain ECN1313 Endat2.1 Output encoder signal Open collector output -max. 27VDC, 50mA- level: 2V or less to be connected to the lift controller (shaft copy) Figure 12: OPC-LM1-PS1 option card connection Table 2: Connection description of terminals for OPC-LM1-PS1 Terminal name in the option card Signal name from Heidenhain Description P0 Up and Up Sensor Supply voltage 5V, connection of Up Sensor mandatory for cable length >10m CM 0V (Up) and 0V Sensor Common 0 V for the power supply PA+ A+ A signal PA- A- A signal inverted PB+ B+ A signal PB- B- A signal inverted CK+ Clock+ Clock signal for serial communication CK- Clock- Clock signal inverted for serial communication DT+ DATA+ Data line for communication of the absolute information DT- DATA- Data line inverted for communication of the absolute information $ Prior to the commissioning, the encoder resolution (pulses per revolution) has to be set using parameter L02. $ For synchronous motors it is also necessary to set the encoder type in function L01.

Page 12 Getting running for the first time and auto tuning Open loop operation Before running for the first time the site motor parameters have to be checked and adjusted to suit. It is recommended that an autotune is then performed. The auto tune is non rotating so the ropes can be left on. The lift should be on inspection, should be ready to run i.e. all emergency stops, car doors and landing locks made. Check the motor data parameters in table 3 are set correctly in menu 0 (quick set) Table 3: Parameters to be set prior to auto tuning Parameter Description Default value New setting P01 Number of motor poles 4 4=1500 rpm 6=1000rpm P02 Motor capacity (KW) As per drive size Set as motor data plate P03 Motor rated Current (Amps) As per drive size Set as motor data plate F04 Motor speed (RPM) 1500 Set as motor data plate F05 Motor Voltage (Volts) 380 Set as motor data plate $ If you wish to switch to open loop so you can run the lift before the motor encoder is fitted set parameter F42 to 2 (torque vector control) Once the motor parameters are set carry out the following procedure. Make sure the motor is correctly connected Set parameter P04 to 3 and press Give the drive a run command by pressing test up or test down. MC & MC1 will come in and there will be an audible motor noise Once the tune is complete release the test direction Closed loop operation For closed loop installations the set up procedure is the same as for open loop, it is also recommended that an autotune is performed before the first travel. The auto tune procedure is carried out the same as for an open loop application. The motor data needs to be set as in table 3, but the additional parameter in table 4 also has to set and checked. Table 4: Parameters to be set prior to auto tuning on closed loop Parameter Description Default value New setting L02 Encoder resolution (PPR) 2048 As per encoder data plate Once the motor parameters are set carry out the auto tune as open loop (see section above).

Page 13 Gearless machines (permanent magnet) For gearless applications the procedure for auto tuning is the same as for the open and closed loop applications above. Once an auto tune is completed a second tune is required for finding the offset of the poles in relation to the permanent magnets, this is known as a pole tune. After carrying out the auto tune set the additional parameter in table 5 below. Table 5: Parameters to be set prior to carrying out a pole tune Parameter Description Default value New setting L05 Current loop controller 1.5 As per following formula L05 = 4, 33 I n L V n [mh] L=Motor inductance (minimum value between Ld and Lq) V n =Motor rated voltage [V] (F05) I n =Motor rated current [A] (P03) The pole tune can now be carried out as follows. This tune checks for wiring abnormalities so it is important that the motor phasing is correct Make sure the motor is correctly connected i.e U-U, V-V, W-W Set parameter L03 to 1 and press Give the drive a run command by pressing test up or test down. MC & MC1 will come in and there will be an audible motor noise and the screen should show executing this tune lasts approximately 4 seconds Once the tune is complete executing disappears from the screen release the test direction $ If ER7 appears whilst tuning it may be because the motor has surface mounted magnets or the motor wiring is incorrect. To check motor wiring is correct rotate the motor a quarter of a turn and make a note of the value in parameter L04 carry out another tune (as above procedure) if the value of L04 is more than 15 different from the previous value the motor wiring is incorrect. If the value is less than 15 out the motor wiring is correct but the motor may have surface mounted magnets. If so set L03 to 4 and tune again. If ER7 still appears contact the ILE technical support department.

Page 14 Final setting prior to running for the first time. The parameters in table 6 have to be worked out and set so the inverter knows how far the lift will travel for 1 revolution of the motor. It needs this information so the speed references and distance based short floor operation work correctly. Table 6: Parameters set before running for the first time Parameter Description Default value New setting F03 Motor RPM at full lift speed 1500 See formula below To work out the above parameter use the formula below. F03 = 19.1 V R D P (R=ROPING RATIO (1 FOR 1:1; 2 FOR 2:1); V=LIFT SPEED IN M/S; D=SHEAVE DIAMETER IN METERS; P= GEAR RATIO e.g. IF THE GEAR RATIO IS 53:2 DIVIDE 2 BY 53 AND INSERT THE RESULT INTO THE FORMULA) Setting speeds, acceleration, deceleration and jerks for High speed S curve for high speed (HS on Skycom Solo, HS or DTS on Skycom) Figure 13: High speed S curve showing parameters. High speed Speed High speed L24: S-curve setting 6 L25: S-curve setting 7 E13: Acceleration/ deceleration time 6 Creep speed Zero speed L19: S-curve setting 1 E12: Acceleration/ deceleration time 5 L26: S-curve setting 8 L28: S-curve setting 10 E14: Acceleration/deceleration time 7 L28: S-curve setting 10 Time From the diagram above we can see the parameters for tuning the high speed S curve the parameters are listed below in table 7 Table 7: High speed parameter settings Parameter Description Default value New setting C07 Creep (level) speed 4Hz, 6m/min, 150RPM Site specific C11 High speed 50Hz, 60 m/min, 1500RPM Site specific L19 Jerk 1 20% Site specific E12 Acceleration rate 1.8 seconds Site specific L24 Jerk 2 20% Site specific L25 Jerk 3 20% Site specific E13 Deceleration rate 1.8 seconds Site specific L26 Jerk 4 20% Site specific L28 Jerk 56 20% Site specific E14 Decel from creep to zero speed 1.8 seconds Site specific The parameters in the above table are all of the speed and comfort settings for a high speed run. All speeds on Geared machines will be set so the units are in Hertz, if it is a gearless application we will set the units as meters/minutes to work these back to meters/second divide by 60.

Page 15 All acceleration / deceleration units are in seconds the bigger the figure the softer the accel / decel. All jerks units are percentages of the S curve you are on, the higher the figure the softer the jerk. Setting speeds, acceleration, deceleration and jerks for medium speed S curve for medium speed (MS1 on Skycom) Figure 14: Medium speed S curve showing parameters. From the diagram above we can see the parameters for tuning the high speed S curve the parameters are listed below in table 8 Speed Manual speed (Middle) Creep speed Zero speed L22: S-curve setting 4 L23: S-curve setting 5 E10: Acceleration/ deceleration time 3 L19: S-curve setting 1 E14: Acceleration/deceleration time 7 E11: Acceleration/deceleration time 4 L28: S-curve setting 10 L26: S-curve setting 8 L28: S-curve setting 10 Time Table 8: Medium speed parameter settings Parameter Description Default value New setting C07 Creep (level) speed 4Hz, 6m/min, 150RPM Site specific C10 Medium speed 50Hz, 60 m/min, 1500RPM Site specific L19 Jerk 1 20% Site specific E10 Acceleration rate 1.8 seconds Site specific L22 Jerk 2 20% Site specific L23 Jerk 3 20% Site specific E11 Deceleration rate 1.8 seconds Site specific L26 Jerk 4 20% Site specific L28 Jerk 56 20% Site specific E14 Decel from creep to zero speed 1.8 seconds Site specific The parameters in the above table are all of the speed and comfort settings for a high speed run. All speeds on Geared machines will be set so the units are in Hertz, if it is a gearless application we will set the units as meters/minutes to work these back to meters/second divide by 60. All acceleration / deceleration units are in seconds the bigger the figure the softer the accel / decel. All jerks units are percentages of the S curve you are on, the higher the figure the softer the jerk. Setting speeds, acceleration, deceleration and jerks for reduced power mode S curve for reduced power mode (RPR on Skycom / Skycom Solo) The Skycom can be parameterised to give an output which when on a non essential journey i.e. Homing and when in a group on no specific traffic pattern, the lift can run at a reduced acceleration, high speed and deceleration rate thus saving energy. The drive parameters for this speed input are as below.

Page 16 Figure 14: Medium speed S curve showing parameters. Manual speed (Low) Creep speed Zero speed Speed L19: S-curve setting 1 L20: S-curve setting 2 F07: Acceleration/ deceleration time 1 L26: S-curve setting 8 E14: Acceleration/deceleration time 7 L21: S-curve setting 3 F08: Acceleration/deceleration time 2 L28: S-curve setting 10 L28: S-curve setting 10 Time From the diagram above we can see the parameters for tuning the high speed S curve the parameters are listed below in table 9 Table 9 : Reduced power mode speed parameter settings Parameter Description Default value New setting C07 Creep (level) speed 4Hz, 6m/min, 150RPM Site specific C09 Reduced power speed 50Hz, 60 m/min, 1500RPM Site specific L19 Jerk 1 20% Site specific F07 Acceleration rate 1.8 seconds Site specific L20 Jerk 2 20% Site specific L21 Jerk 3 20% Site specific F08 Deceleration rate 1.8 seconds Site specific L26 Jerk 4 20% Site specific L28 Jerk 56 20% Site specific E14 Decel from creep to zero speed 1.8 seconds Site specific The parameters in the above table are all of the speed and comfort settings for a high speed run. All speeds on Geared machines will be set so the units are in Hertz, if it is a gearless application we will set the units as meters/minutes to work these back to meters/second divide by 60. All acceleration / deceleration units are in seconds the bigger the figure the softer the accel / decel. All jerks units are percentages of the S curve you are on, the higher the figure the softer the jerk. Inspection speed Inspection speed is set in our test department at 15Hz for geared machines or 10 meters/minute for gearless machines if the speed needs increasing or decreasing table 10 highlights the parameter. Table 10 : inspection speed parameter settings Parameter Description Default value New setting C06 Inspection speed 15Hz, 10m/min Site specific

Page 17 Performance related settings Brake lift / release timers The FRENIC inverter controls the lifting of the brake via a relay output (terminals Y5C & Y5A) this in turn drives the BKC contactor on the controller, which then switches the brake voltage. If the brake lifts or drops particularly fast or slow there may be issues with rollback, snatch or general ride discomfort at the start and stop of operation. Table 11 shows the parameters for controlling the brake. Table 11: Brake parameter settings Parameter Description Default value New setting L82 Brake lift time 0.2 seconds Site specific L83 Brake drop time 0.2 seconds Site specific Critical settings for open loop No load current (parameter P06) The no-load current (function P06) defines the value of the current of the motor when no load is applied to the motor (exciting current). Typical values of the no-load current range from 30 % of P03 up to 70 % of P03. In the majority of the cases the value measured by the auto-tuning procedure will be correct. In some cases the auto-tuning procedure cannot be finished correctly (due to unusual behaviour of the motor). In this later case the value of P03 must be set manually. To calculate the no-load current you can use the formula P06 = ( P03) 2 2 P02 *1000 1.47 * F05 If the value of P06 is too low you will find that the motor does not have enough torque. I the value is too high the motor oscillates (this oscillation will cause a vibration in the motor that is transmitted to the cabin). Slip frequency (parameter P12) The slip frequency function defines the value of the slip frequency of the motor. It is the key function for good slip compensation by the inverter; this means that this function is very important in open loop control of induction motors for good floor levelling accuracy because it will ensure that the rotating frequency of the motor is the same regardless of the load condition of the motor. In the majority of the cases the value measured by the auto-tuning procedure will be correct. In some cases the auto-tuning procedure cannot be finished correctly (due to unusual behaviour of the motor). In this later case the value of P12 must be set manually. To set function P12 manually we can calculate it from the following formula: ( Synchronous _ speed( rpm) Rated _ speed( rpm)) No _ Poles P 12 = 0,7 120

Page 18 Slip compensation gains (parameter P09 for driving, P10 for braking) The slip frequency can be also compensated in both driving and braking mode. The method for adjusting these values is as follows. You need to measure one floor level with car empty both going up and down: - If the car speed going up is lower than the desired speed (the car doesn t reach floor level) decrease the value of P10 by 10% (braking mode). - If the cabin speed going down is higher than the desired speed (the car goes past floor level) decrease the value of P09 by 10% (driving mode). Adjust these parameters until good floor levelling accuracy is achieved. Gains (closed loop and Gearless) The driving and braking gains of the FRENIC inverter may be adjusted to increase performance with respect to undershoot, overshoot, hunting during high speed and noise / vibration in the motor. The parameters are shown in table 12 below. Table 12: Gain parameter settings Parameter Description Default value New setting L36 ASR P CSTANT (high 10% Site specific speed) L37 ASR I CSTANT (high 0.02 Site specific speed) L38 ASR P CSTANT (low 10% Site specific speed) L39 ASR I CSTANT (low speed) 0.02 Site specific L38 ASR P CSTANT (low speed) 10% Site specific The higher the percentage value the tighter the control of the motor will be, also the smaller the time constant the tighter the control will be. $ All gain parameters should be adjusted in small increments, too high or low value can cause the motor to lose control of the load. Consult ILE s Technical support department if you are unfamiliar with adjusting these parameters. Anti roll back parameters (gearless only) The FRENIC inverter has an extra set of gain parameters for controlling high out of balance loads in gearless applications. Once enabled the time, P gain and I gain can be adjusted to eliminate any roll back. $ Anti roll back parameters should only be enabled after the brake release and drop timers have been set and the gains adjusted (see section 12.1 and 12.2) The parameters are shown in table 13 below. Table 13: Anti roll back parameters (ULC Compensation) Parameter Description Default value New setting L65 ULC ENABLE 0 1 (to enable) L66 ULC ACTIVATI TIMER 1 Site specific L68 ULC ASR P CSTANT 10 Site specific L69 ULC ASR I CSTANT 0.5 Site specific L73 ULC ASR GAIN 5 Site specific

Page 19 Anti roll back is enabled by changing parameter L65 to 1 The time the anti roll back is enabled for is set using parameter L66 (this should not need to be more than default) The gains in parameters L68, 69 & 73 should then be adjusted until the roll back is adjusted out. $ The default parameters set by ILE should eliminate any roll back, if you are unfamiliar with adjusting these parameters consult ILE s Technical support department Brake Checking Signal for UCM Compliance (EN81-1 + A3) Introduction From January 2012 the lift standard EN 81-1:1998+A3:2009 has to be applied. A3 addendum is related to Unintended Car Movement (UCM). In case of electrical traction lifts, one possible solution to fulfill the new A3 addendum of the EN81-1 standard, is to use the two brakes certified according to this standard that are directly coupled to the driving sheave (gearless) and additionally monitor their status individually, by using one switch for each brake that detects the actual brake status (released or applied). If the detected brake status is not correct the operation of the lift must be prevented. The following section explains how to set the function, test the function and reset any alarms related to the UCM. Description of the function and parameters The parameters related to the UCM function are shown below. Parameter Description Default value New setting E06 Command Assignmet to Input X6 25 111 E07 Command Assignmet to 25 112 Input X7 H95 BBE Alarm Reset 0 See description H96 Check Brake Control 0 1 L84 Brake Control Check Time 0.00 2.00 This function is not active in factory default settings. It means that this function has to be activated. The parameter used to activate this function is H96. The functionality of H96 is explained below. H96 is set automatically during the wizard if the response to the brake switches fitted and connected question is yes. a) When H96 = 0 Even BRKE1 and BRKE2 functions are correctly programmed (E06 set to 111 and E07 set to 112) and wired, monitoring function for UCM is not active. b) When H96 = 1 Brake monitoring operation is performed by the BRKE1 and BRKE2 inputs according to UCM. When BRKE1 or BRKE2 status is not correct, the timer of brake check time (L84) starts. BBE alarm is generated when the BRKE1 or BRKE2 inputs remain in an incorrect condition during the brake check time (L84). During the lift travel, the alarm is not issued, the alarm is generated as soon as BRKS function is OFF and L84

Page 20 Function Behavior timer expires. For additional details, please refer to the function behavior diagram below. In the following figures, each possible scenario using BRKE1 and BRKE2 functions are explained. Brake feedback is abnormal at starting Speed High speed Standard travel Travel with abnormal brake operation at starting Creep speed Stop speed(f25) 0 EN (EN1,EN2) H67 FWD S S 1 S S 2 S S 4 BRKS BRKE1 Zero speed command High speed command Creep speed command Zero speed command BRKE2 Brake1 Release Release Brake2 Release ALM L82 L84 L83 L84 L82 L84 Inverter trips bbe.

Page 21 Brake feedback is abnormal at stopping Speed High speed Creep speed Stop speed(f25) 0 EN (EN1,EN2) H67 FWD S S 1 S S 2 S S 4 BRKS BRKE1 Zero speed command High speed command Creep speed command Zero speed command BRKE2 Brake1 Release Brake2 Release ALM L82 L84 L83 L84 Inverter trips bbe. Brake feedback is abnormal during travel (with BBE trip) Speed High speed Creep speed Stop speed(f25) 0 EN (EN1,EN2) H67 FWD S S 1 S S 2 S S 4 BRKS BRKE1 Zero speed command High speed command Creep speed command Zero speed command BRKE2 Brake1 Release Brake2 Release ALM L82 L84 L84 L83 L84 Alarm is internally generated. Inverter trips bbe.

Page 22 Brake feedback is abnormal during travel (no BBE trip) Speed High speed Creep speed Stop speed(f25) 0 EN (EN1,EN2) H67 FWD S S 1 S S 2 S S 4 BRKS BRKE1 Zero speed command High speed command Creep speed command Zero speed command BRKE2 Brake1 Release Release Brake2 Release ALM L82 L84 L84 L83 L84 Inverter doesn t trip with bbe, because L84 timer is not expired. Inverter doesn t trip bbe. Brake feedback is abnormal when the lift is stationary Speed 0 EN (EN1,EN2) FWD S S 1 S S 2 S S 4 BRKS BRKE1 BRKE2 Brake1 Release Brake2 Release ALM L84 Inverter doesn t trip with bbe, because L84 timer is not expired. L84 Inverter trips bbe

Page 23 Test of BRKE1 Function at start To test the function follow the following flowcharts BRKE1 function test at start Make a normal call demand on the lift by entering the call from the CPU As soon as the inverter is in RUN mode short between +24V and BKS1 at X15 on the terminal rail L84 time is expired Inverter trips bbe? NO YES Remove the short Function not properly working check all parameters set correctly Follow the reset procedure on page 28 of this manual NO Error is reset? YES Function Testing is finished

Page 24 Test of BRKE1 function during travel BRKE1 function test during travel Make a normal Car call demand on the lift using the CPU During high speed Short between +24V and BKS1 on X15 of the terminal rail L84 time is expired Travel is finished Inverter trips bbe? NO YES Remove the short Function not working properly check all parameters set correctly Follow the Reset procedure on page 28 of this manual NO Error is reset? YES Function testing finished

Page 25 Test of BRKE2 Function at start BRKE1 function test at start Make a normal call demand on the lift by entering the call from the CPU As soon as the inverter is in RUN mode short between +24V and BKS2 at X15 on the terminal rail L84 time is expired Inverter trips bbe? NO YES Remove the short Function not properly working check all parameters set correctly Follow the reset procedure on page 28 of this manual NO Error is reset? YES Function Testing is finished

Page 26 Test of BRKE2 function during travel BRKE1 function test during travel Make a normal Car call demand on the lift using the CPU During high speed Short between +24V and BKS2 on X15 of the terminal rail L84 time is expired Travel is finished Inverter trips bbe? NO YES Remove the short Function not working properly check all parameters set correctly Follow the Reset procedure on page 28 of this manual NO Error is reset? YES Function testing finished

Page 27 Fault codes and their meanings Table 14 is a list of all the event codes on the FRENIC inverter, if any events persist please consult ILE s technical support department Table 14: Fault codes Alarm message Displayed OC OU LU Lin OH1 Description Motor overloaded: OC1= Overload during acceleration OC2= Overload during deceleration OC3= Overload during constant speed Overvoltage in inverter DC link: OU1= Overvoltage during acceleration OU2= Overvoltage during deceleration OU3= Overvoltage during constant speed Under voltage in inverter DC link Input phase loss Inverter heat sink temperature too high Possible causes Check if the motor is connected correctly Check motor data has been entered correctly Check brake operation Braking is resistor not connected or defective Lift not balanced correctly Deceleration time too short Check mains connection Supply voltage too low Mains supply failure Acceleration too fast Load too high Check connection of the input signal Check mains input fuses Check input connections Inverter fan defective Ambient temperature too high OH2 External Alarm Not used in ILE controller OH3 Ambient temperature around inverter too high Check temperature inside controller cabinet OH4 Motor over temperature detected Not used in ILE controller PG Encoder error Check encoder cable Motor not rotating (safety gear in) Brake did not lift OL1 Motor overload Check brake Motor, car or counterweight safety gear in Inverter at current limit, possibly too small Check functions F10~F12 OLU Inverter overload Over temperature in IGBT Failure in the cooling system Switching frequency (function F26) too high Lift load too high. Er1 Save error Data has been lost Er2 Keypad communication error Keypad was removed while inverter in was running Er3 CPU error Failure in the inverter CPU Er4 Option card communication error Option card not correctly installed. Check cables and shield connection. Er5 Option card error Check configuration (switches and bridges correct?) Check cables and shield connection. Er6 Operation error Check parameter L80, L82, L83, L84 If gearless carry out pole tuning Er7 Error during auto tuning / pole tuning Check MC contactors are not open Check encoder cable Check encoder Er8 RS485 Comms error High noise level Check connection ErE Speed error Check brake Check safety gear is not in Check parameters L90- L92 Current limiter active

Page 28 ErH OS bbe Option card hardware fault Motor speed greater than L32xF 03 (rpm) 100 Sub code 11 BRKE1 signal is abnormal Sub code 12 BRKE2 signal is abnormal If gearless was pole tuning successful Option card not correctly installed Inverter software not compatible with the option card Check encoder resolution parameter L02 Check parameter F03, P01, L32 Check status of the brake micros 1 or 2 Check +24V is present at the brake switches Check L84 time bbe Reset procedure Because UCM brake switch monitoring is a safety feature it has to be reset via the correct procedure. The event cannot be reset by cycling the inverter power. First clear the problem by checking the status of the brake switches, brake switch time (L84) and the supply to the brake switches. Go to parameter H95 and enter the value 111 followed by the FUNCTI DATA button Press RESET repeatedly until the bbe event is cleared. $ NOTE: The bbe event will not clear if the fault that caused the issue in the first instance is not fixed. Document History Version Changes Date Author Checked Approved V1.0 Initial Version 31/9/11 J. Colquhoun R. Bierton J. Miller V1.1 Text updated 03/09/12 J. Colquhoun R. Bierton J. Miller V1.2 UCM function added 20/10/12 J. Colquhoun R. Bierton J. Colquhoun V1.3 UCM function ammended 15/07/13 J. Colquhoun C. Saunt J. Colquhoun