HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

Similar documents
Appendix: Safety and application notes for... 15

HOYMILES MICRO-IVERTER MI-250

MICRO-INVERTER OMNIKSOL M-300

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

Instruction Manual. Harmonic Filter AHF 005/010. Drives Solutions

Differential Pressure Transmitter

HBLT-C1 Controller. Instruction Manual. For pump control of levels in industrial refrigeration systems

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Compact System NRGS 11-2 NRGS Original Installation Instructions English

User Manual Rittal PMC UPS 6kVA

Dimensions WxHxD [mm] Weight [kg]

! C A U T I O N! Damages on the machine possible.

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

MWF+ Application. Types Available. Average temperature sensor. Datasheet

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

PURE SINE WAVE DC TO AC POWER INVERTER

Ucontrol. 1 Data sheet. Multipurpose controllers for variable voltage 3 ~ fans PXDM Examples of application. 1.2 Equipment / Function

SOLSTART Instruction Manual

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

USE AND INSTALLATION HANDBOOK

Appendix: Safety and application notes for 19

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

1.Safe testing IMPORTANT:

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Triple Output Power Supply

Actuators for air and gas dampers

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Pressure chlorine changeover unit C 7520

Technical Documentation

USER MANUAL MPS 1-5KW SERIES

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Assembly and Maintenance Manual Type ASNU

VT Oil-Free Range Operators Handbook

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

PRECISION UK Ltd DUPLEX AGSS PLANT

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Switching DC Power Supply

Pure sine wave charger inverter Product Manual

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

High Frequency SineWave Guardian TM

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

PREFACE. Dear customer,

Source Capture Air Purification System

Uninterruptible power supply Supply MEg101.4

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

RVS-AX Instruction Manual

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

GEWAS 181 A. Alarm- and protection device Leak-water detector

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

SPECIAL REVERSE HORIZONTAL FLOW ENCLOSURE OPERATING AND MAINTENANCE MANUAL. Issue No: 1

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

Assembly and Maintenance Manual Type AS

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

FL ballasts Electronic fixed output. PC T5 TOP lp, W PC TOP T5

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Multi-Mover Charger for model L25

Operating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Pulsar EXtreme 2200C / 3200C

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

LEAD ACID BATTERY CHARGER

Breezair TBA 550 Installation Manual

Installation and Operating Instructions. Solar System Controller ISC3020

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

Pulsar EXtreme CLA 1500C

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Fuse state indicator MEg72. User manual

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

Clamping and drive module

AIR COOLED CHILLERS WATER COOLED CHILLERS

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

DC POWER SUPPLY ALIMENTATION C.C.

16 37 TM INTEGRATED RADIO CONTROL INSTRUCTION MANUAL

OWNER S MANUAL MiniBoost

EPS/ELA-Series User Manual EPS/ELA 250W

Installation manual wall-mounted distributor

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

HBLT-Wire LEVEL SENSOR For analogue measurements of NH3 and HFC in refrigeration systems

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Transcription:

HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

2

Heat exchanger Fan Mounting hole Speed control Air flow hole Technical information plate Power cable 230V Glycol inlet/outlet WARNING During the installation the heat dump unit should be disconnected from the el. main until the final installation and putting into function is done. USER INSTRUCTIONS User instruction consists of installation and usage instructions. This instruction is integral part of every cooler unit, and it should always be with the cooler and also during every displacement or installation, so technical personnel could use it. Before installation and usage of cooler, you should carefully read this user instruction in which there are important information for correct and safe use. Unit weight is 18 kg. NOTE: The unit should be installed and serviced by a suitably trained person. 1. Unpack the unit from its transportation packaging and visually inspect for signs of damage. 2. Site the heat dump in a convenient location, preferably in a non heat sensitive and shaded area on the outside of building. If it can not be installed outside, ensure that the area is free from other heat sources. The unit should be sited to allow free circulation of air. Height from the ground to base of unit should not exceed 9 metres. (30 feet) 3. Fix the unit to the wall. HEAT DUMP PIPES 1. Heat dump pipes are 15 mm and must be run with a space between the flow and return. 3

2. Only approved glycol tubing can be used. PVC pipes must never be used it is unsuitable for hot glycol. DISMANTLING DECOMMISSIONING PROCEDURE 1. Plug out the unit from Electricity Supply. 2. Disconnect the recirculating coolant Inlet/Outlet pipes. ADJUSTMENTS MAINTENANCE REQUIREMENTS It is not recommended that the end user makes any adjustments or carriers out any maintenance other than: 1. Check the mains lead and plug visually for condition. 2. Check the unit and its pipe work for evidence of leaks visually. METHODS OF CLEANING NOTE: Do not use a water or stream hose to clean the unit whilst still installed. NOTE: It is important that all the vents and grills are kept clear (including condenser grills where applicable). NOTE: Personal protective equipment should always be used. Twice annually: by a competent service / maintenance engineer: 1. Isolate the unit from the base cooler Electricity supply 2. Remove any extraneous debris from the unit or its casing preferably using a vacuum cleaner or a brush. 3. Check unit for electrical safety. Max. / min. ambient temperature (recommended) Minimum: - 5 C (nb 30% glycol/watermix) Maximum: 32 C WARNING In accordance with current law regulation, installation and use of unit must be done by specialized and adequate trained technical personnel. SPEED CONTROL PKE-2.5V UNIT OPERATION To operate HD unit, power supply should be 230V, 50 Hz. Connecting cable (5m) is directly connected to control box. Electronic circuit installed into control box placed on HD unit has function that depending on temperature (according to temperature probe) of heat exchanger regulates fan speed. Important is that temperature probe is correctly installed on appropriate place, otherwise will operate incorrectly. 4

PROGRAMMING THE REQUIRED FUNCTION Operation as controller = J1 to "Set" = down position: (P-controller with increasing speed for increasing actual value) Settings for "n-min", "P-band" and "Set" = RECUIRED value For operation as a controller, the actual value measured by the sensor is compared with the nominal value that has been set. The output voltage and hence the rotational speed of the connected motor automatically change as a function of the parameter settings. 5

Sensor selection: - Temperature sensor TF..(KTY10-6) = "J4" and "J5" up = "A" (factory settings) connection at terminals "E" and "GND" - settings: set value "Set" 0-100% 0-60ºC, control range "Pband" 10-30% 6-18, "n-min" 0-100% (measuring range approx. 0 to 80 ºC) Oprema settings: JUMPER J1 SET J4 A J5 A POTENTIOMETERS n-min adjusted to 0% (minimum) Pband adjusted to 30% (maximum) Set adjusted to 50% (~30-35 C, middle position) Technical data - Line voltage 1-230V (-15% / +10%), 50/60 Hz - Rated current 2.5A (at line voltage 230 V) - Min. motor current 0.2 A - Stepless controlled output voltage approx. 25-100% (deactivation at approx. 25%, restart at approx. 35%) - Maximum line fuse 10 A - Sensor supply +24 V (+20% / -31%) Imax. 20mA - Max. heat dissipation approx. 10 W - Max. permissible ambient temperature 40ºC - Permissible rel. humidity 85% no condensation - Interference emission EN 50081-1 - Interference immunity EN 61000-6-2 - Harmonics current EN 61000-3-2 - Housing protection / PKE2.5V IP 54 0,50 kg weight PKE2.5VE IP 20 0,26 kg 6

SAFETY INFORMATION - Apart from the operating instructions and the obligatory regulations to be followed by users relating to accident prevention, the recognized technical regulations must also be observed (safety and branch-related work as per UVV, VBG, VDE, etc.). - These devices are potentially dangerous if they are used incorrectly by untrained personnel or are not implemented according to their specified use. - Work on electric components/modules may only be carried out by trained electricians in accordance with electro-technical regulations (e.g. EN60204, DIN VDE 0100/0113/0160). The contractor or owner must also ensure that the electric systems and equipment are operated and maintained in accordance with electro-technical regulations. - It is forbidden to carry out work on electrically live parts. The enclosure rating of the device when open is lp00! It is possible to inadvertently touch components carrying hazardous voltages! - During operation, the device must be closed or installed in a control cabinet. - Fuses may only be replaced by new ones and must not be repaired or bypassed. - Use only fuses mentioned in schematic diagram. - The safe isolation from the supply must be checked using a two-gole voltage detector. - Any faults detected in the electric system/modules/operating equipment must be corrected immediately. If these faults are not corrected, the device/system is potentially very dangerous. The device/system must therefore not be operated when it is faulty. Transport and storage - Always use the original packaging materials when transporting the controller. - Avoid shocks and impacts to the device. - Check the packaging and controller for damage. - Store the controller in its original packaging in a dry and weather-proff room. - The device must not be exposed to extreme heat and low temperatures 7

DISASSEMBLING INSTRUCTIONS Disassembling procedure must be done in accordance with law regulations related to: Steel, plastic and other materials should be put aside by authorized person Insulation material must be removed by authorized companies and persons Symbol of crossed can means that product at the end of its life cycle must be put apart from other waste, related with decreasing use of dangerous substances in electrical and electronic devices, and also in accordance with adequate waste disposal. Individual collection and recycling of this equipment allow us to avoid negative effects on environment, and we can recycle and again use some of the parts. Unauthorized disposal of units by users can be penalized in accordance with current low regulations 8

9