USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

Similar documents
Solar Power Light Meter

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Digital Formaldehyde Meter

Non-Contact Phase Rotation Tester

USER GUIDE Moisture Meter

User's Manual. Earth Ground Resistance Tester. Model Introduction

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Hot Wire CFM/CMM Thermo-Anemometer

Non-Contact Phase Rotation Tester

User Guide. Model Insulation Tester / Megohmmeter

User's Guide. CO 2 Meter. Model CO250

Model Battery Powered Milliohm Meter

User's Guide. Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer. Introduction

DT304. Digital Temperature Logger INSTRUCTION MANUAL

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

Model Insulation Tester / Megohmmeter. User Manual

USER MANUAL. Insulation Tester + DMM. Model MG320

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

operating manual DL7 101 DIGITAL THERMOMETER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Phase Sequence Tester

User Guide. Model Insulation Tester / Megohmmeter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

362 Clamp Meter. Users Manual

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

MANUAL DE INSTRUÇÕES DO ANEMÔMETRO DIGITAL MODELO AN-3040

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

Cable Length Meter INSTRUCTION MANUAL

True RMS Autoranging Multimeter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

User's Guide. Vane Anemometer. Model Measures Air Velocity & Temperature. Degrees C/F switchable

Autoranging Multimeter

Quick Guide. brite Advanced Retail scale

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

i-stat 1 Analyzer 2 Before You Use the Analyzer

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Marin Control Digital

1.Safe testing IMPORTANT:

DOUBLE WAYS THERMOCOUPLE METER. Users Manual

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

DAFM4. Digital Air Flow Meter INSTRUCTION MANUAL Fax: (503) ENGLISH DAFM4 VOL CFM

Autoranging Industrial Multimeter

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Thermocouple Thermometer Models

Barnant Company (Type J) (Type K) (Type T)

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

OPERATING INSTRUCTIONS

CHAD VALLEY BABY. 578/1812 Deluxe Baby Bouncer. Circus Friends

Window Thermometer models / / 00423

DIGITAL RCD(ELCB) TESTER

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Safety design conforming to the following provisions

EM20 Digital Anemometer User Manual

User Manual. CFM/CMM Vane Thermoanemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT


INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Self-Leveling Rotary Laser Level with GreenBrite Technology Model No Instruction Manual

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

Visit us at

SERVICE MANUAL. STARTER Portable Meter ST300 ST300C ST300D ST400D. Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ (973)

Users Manual. Airflow Meter

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

FOR YOUR PERMANENT FILE

Instruction Manual. Single-Input Thermistor Thermometer (Model )

Electronic Cordless Sweeper. Operating Instructions

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

Humidity Monitor model 00619

Installation and Connection: Installation and Operating Manual

IAQ-CALC TM Indoor Air Quality Meter

Panel Mount Digital Tachometer Model

82V LITHIUM-ION BATTERY CHARGER GC 400

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Safety design conforming to the following provisions

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Thermometer models / 00831A

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

User's Guide. True RMS Multim eter. Extech 430

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

This manual covers the following model:

752 Recipe Converter Instruction Manual

PAC 600 PAC 800 PAC 800 comfort

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

OPERATING INSTRUCTION

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

FOR YOUR PERMANENT FILE

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

RECHARGEABLE POWER OUTAGE LED LIGHT INSTRUCTION MANUAL

Transcription:

USER GUIDE Model RH10 Hygro Thermometer Humidity and Temperature Meter

Introduction Congratulations on your purchase of the Extech Hygro Thermometer Model RH10. This device measures relative humidity and air temperature using the attached probe. The large, easy to read backlit LCD includes primary and secondary displays plus status indicators. To conserve battery energy the meter switches OFF automatically after a 30 minute period of inactivity. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Please visit our website (www.extech.com) to check for the latest version of this User Guide, Product Updates, and Customer Support. Safety The probe extending from the top of the meter houses the sensitive measurement sensors, do not mishandle, shock, or allow liquids to come into contact with it. The probe sensor can cause personal injury if it is misused or mishandled. Use caution when handling this device. Do not allow children to handle this device or the accessories and packing materials supplied with it. The meter uses a 9V battery (installed in the rear battery compartment). Please remove the battery from the meter if the meter is not to be used for a long period of time. Spent batteries that remain in the meter could potentially leak and cause damage to the meter. 2

Meter Description Front side of meter 1. Relative Humidity and Air Temperature Probe 2. Power ON/OFF button 3. Backlight ambient light sensor 4. Relative Humidity reading on LCD 5. Air Temperature reading on LCD 6. MAX MIN button Rear side of meter 7. Threaded Tripod mount 8. Temperature units select switch access 9. Battery compartment 3

Display Layout 1. Temperature reading digits 2. Relative Humidity reading digits 3. Low Battery symbol 4. Maximum air temperature and relative humidity measurements 5. Minimum air temperature and relative humidity measurements 6. Relative Humidity unit of measure 7. Temperature units of measure 8. Auto Power OFF reminder clock symbol 4

Operation Power Press the Power button to switch the meter ON or OFF. If the meter does not switch ON when prompted, check that a fresh 9V battery is installed in the rear battery compartment. To conserve energy, the meter switches OFF automatically after 30 minutes of inactivity. Relative Humidity and Temperature Measurements 1. Switch the meter ON. 2. Hold the probe in the area to be tested & allow adequate time for readings to stabilize. 3. Read the Relative Humidity measurement in %RH units at the center of the LCD. 4. Read the Air Temperature in degrees C or F on the lower display digits. NOTE: Do not immerse the probe in liquid; it is intended for use in air only. o F/ o C units selection 1. Ensure that the meter is switched OFF. 2. Open the battery compartment by carefully sliding the rear compartment cover downward. 3. Remove the battery from the compartment. The battery can remain connected to the red/black wires but it must be physically removed from the compartment cavity. 4. The unit of measure can be changed using the surface mount selector switch located on the printed circuit board accessible through an opening in the battery compartment. See the Description section of this manual for the location of the opening. 5. With good lighting, locate the switch visually. Then use a non-conductive screwdriver or other tool to toggle the switch left or right. The switch is labeled in the battery compartment. If the label is removed, move the switch to the left for degrees F and to the right for degrees C. 6. Place the battery back in the compartment as detailed in the battery replacement section. 7. Switch the meter ON and verify that the LCD display shows the desired unit of measure. MAX MIN Recording 1. Press the MAX MIN button to display the highest readings (maximum) recorded. The readings shown will be the highest readings measured since the meter was switched ON. The MAX icon will appear at the top of the LCD. 2. Press the MAX MIN button again to display the lowest readings (maximum) recorded. The readings shown will be the lowest readings measured since the meter was switched ON. The MIN icon will appear at the top of the LCD. 3. Press the MAX MIN button again to switch the display back to real time measurement indicator mode. The MAX and MIN icons will switch OFF. LCD Backlight The LCD backlight switches ON automatically when the ambient light dims below the threshold. The ambient light sensor is located directly above the LCD window. To test the backlight, cover the ambient light sensor and the LCD backlight should immediately switch ON. 5

Maintenance Cleaning and storage 1. Meter housing only: Clean with a damp cloth and mild detergent when necessary. Do not use solvents or abrasives. 2. Do not attempt to introduce liquid into the probe access holes when cleaning. The probe head can be cleaned using a dry, lint free cloth to dust and to free debris from the probe openings. 3. Store the meter in an area with moderate temperature and humidity. Battery Replacement The battery symbol appears on the LCD when the 9V battery needs to be replaced. Note that the meter automatically switches OFF after 30 minutes of inactivity to conserve battery energy. Replace the 9V battery as follows: 1. Switch the meter OFF if necessary. 2. Remove the rear battery compartment cover by sliding the compartment cover downward. 3. Replace the 9V battery carefully. 4. Place the red and black wires cautiously in the battery compartment to avoid crimping when closing the compartment cover. 5. Always re assemble the meter before operating. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. Other Battery Safety Reminders o Never dispose of batteries in a fire. Batteries may explode or leak. o Never mix battery types. Always install new batteries of the same type. WARNING: To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely. 6

Specifications Function Range and Resolution Accuracy Humidity 0.0 to 20.0% RH 20.0 to 80% RH 80.0 to 95.0% RH ± 5.0% RH ± 3.5% RH ± 5.0% RH Air Temperature 20.0 to 60.0 o C ( 4.0 to 140.0 o F) ± 2.0 o C (± 3.0 o F) Display Accuracy note Sampling Rate Auto Power OFF Operating Conditions Storage Conditions Power Supply Battery Life Dimensions / Weight Dual LCD with backlight and status indicators Accuracy is specified for the following ambient temperature range: 18 to 28 C (64 to 82 F) 2 samples per second Meter automatically switches OFF after 30 minutes of inactivity 0 to 50 o C (32 to 122 o F); < 80% RH non condensing 10 to 60 o C (14 to 140 o F); <80% RH non condensing 9V Battery Approx. 150 hours 135 x 229 x 46mm (5.3 x 9 x 1.8 ); 200g (7.0 oz.) Copyright 2013 2015 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form www.extech.com 7