Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

Similar documents
Flow volume: l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

LPE4. OptiLine. Product Description. Max differential pressure: 16 bar LPE GB

ACD6. Std Line. Product Description. Max differential pressure: 7 bar Circulation, lubrication and transfer ACD GB

ACG7. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACG GB

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer ACF GB

Flow volume: 2-24 l/min Max differential pressure: 10 bar Applications: Lubrication, circulation and transfer

Screwpump Series ACD

ACF5. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer

LPE3. Std Line. Product Description. Max differential pressure: 16 bar Circulation, lubrication and transfer LPE GB

Screwpump. Series D GB. General Description. Model Code D 4

Alfa Laval three-screw pump

Opti Line ACG8 Screw pump Maintenance & Start up Instruction

Series PRODUCTS. self-priming Horizontal screw pump for non lubricating liquids. Water. Seawater. Heavy fuel oils. Bilge/Ballast pumps

Seamless Performance Upgrade to IMO OptiLine

ISD SO-NB-G105 SO-NB-G85 SO-NB-P46 PV2R1-* - * -RAA-42/4290 PV2R2-* - * -RAA-41/4190 PV2R3-* - * -RAA-31/3190 PV2R4-* - * -RAA-30/3090

EMTEC Series 3-Screw

8L SERIES THREE SCREW PUMPS

In Motion. A company presentation from I MO A B. A company presentation from IMO ab 1 A Colfax Business Unit

TRITEC SERIES THREE SCREW PUMPS

LEISTRITZ PUMPEN GMBH. Leistritz Screw Pumps & Systems L3MA 3 L. The new L3MA pump series according API 676 3rd. API 676 3rd. 6 3r

Hydraulic gear pumps and motors

This instruction is valid for all ACE pump models shown on page 2

Pumps. s i n c e PUMPS. KRAL Screw Pumps. Overview.

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

Pumps. KRAL Screw Pumps C Series. Quality, innovation and short lead times.

TXV series. pumps with control. variable displacement piston pumps. TXV - Presentation ADVANTAGES

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Maintenance and Service Instruction

Pump your business. 40 bar program. Screw pumps series SMxT16B Dry & submersible screw pumps for industrial applications

Product Range IDEX CORPORATION

VIKING HEAVY DUTY PUMPS SERIES 225 AND 4225 JACKETED BRACKET, STANDARD CONSTRUCTION FEATURES

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

This instruction is valid for all ACF/UCF pump models shown on page 2

This instruction is valid for all ACF/UCF pump models shown on page 2

Variable displacement axial piston pumps,

L & C SERIES. Lubrication & Circulation Pumps. Pump Your Heart Into It

ACG/UCG 7. Maintenance and Service Instruction. Screw pumps. This instruction is valid for all ACG/UCG pump models shown on page 2

KRAL Pumps with Magnetic Coupling.

PRODUCT SERVICE MANUAL FOR. F312XICR-312_, 325_, 400_ and 437_ Pumps. For Solar Turbines

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

MODEL PRESSURE REDUCING REGULATOR BODY SIZES 1/4" OR 3/8" (DN8 or DN10) TECHNICAL BULLETIN 3381-TB FEATURES APPLICATIONS

Quality. 1. Cam ring 2. Cam roller 3. Piston 4. Shaft coupling Connection block 10. Valve plate 11. Axial bearing 6

Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Nominal Flow. Pressure Range. Temp. Range. Viscosity Range. Stainless Steel.

Product Service Manual For AA3G Series Pumps Size 187 Through 250

GRUNDFOS DATA BOOKLET. Grundfos UPBasic. Circulator pumps 50 Hz

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE


1½" GR Internal Eccentric Gear Pump

D SERIES HYDRAULIC PUMP

Vickers. Vane Pumps. Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment.

Gusher s s Advantages

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 )

INSTRUCTION MANUAL AND PARTS LIST FOR PG/RG3D_-187, 218, 250 and 312 SERIES PUMPS

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 BEARINGS 303

MS-Series. S Series. Twin Triple Screw Pumps.

PRODUCT OBSOLETED 1Q16

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 100. Staffa Fixed Displacement Hydraulic Motor

Axial piston variable pump (A)A4VSO

SCM M2. Other advantages:

Gerotor pump, fixed displacement volume

NV452 Monoblock directional control valve

VIKING GENERAL PURPOSE PUMPS SERIES 32 AND 432

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Squirrel Cage Induction Motors MA - A4 - BB - B4 - B5 SERIES SIZES. MarelliMotori ASI.CT.033.2

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Product Manual. MARATHON EN395-6h 2009

KRAL Screw Pumps K Series.

High Pressure Gear Pumps KP 5

2SP TWIN SCREW PUMPS ABS BV DNV GL LR RINA SERIES

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

SCM DIN. Other advantages:

HYDRAULIC-MOTORS. Radial Piston Motors with fixed displacement RM...X series V g = 250 cm 3 /rev cm 3 /rev

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

K12DHZ-312P Pump PRODUCT SERVICE MANUAL. Imo Part Number / BOM # 3220/523

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

VIKING UNIVERSAL SEAL PUMPS. Heavy-Duty, Foot-Mounted Internal Gear Pumps With Multiple Seal Options. Operating Range1: Nominal Flow Rates:

INSTRUCTION MANUAL AND PARTS LIST FOR A3D SERIES PUMPS

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Contents. Directional Control Valve 3 Series CV 452. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves.

SCM ISO. SCM ISO is a range of robust axial piston motors especially suitable for mobile hydraulics.

PRODUCTS PRESENTATION

Discharge rate* 2 L/min MPa (DE10-1) 37.8 MPa (DE10-7)

PERMANENT MAGNETIC COUPLINGS

GRUNDFOS DATA BOOKLET MTS. Screw pumps 50/60 Hz

Variable displacement axial piston pumps,

Pumps. KRAL Screw Pumps. K Series.

FIXED DISPLACEMENT VANE PUMPS

Directional Control Valve CV550

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Variable Displacement Plug-In Motor A6VE

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

UNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Product Service Manual For DLH12DHT SERIES PUMPS

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Hydraulic Pump Series F1plus Fixed Displacement

Transcription:

Opti Line ACG8 Screw pump Product description Flow volume: 80 1200 l/min Max differential pressure: 16 bar Applications: Lubrication, circulation and transfer

The ACG pumps are used for a number of different uids: Lubrication oil, fuel oil, vegetable oil, hy drau lic oil and other hydraulic uids, glycol, polymers, emulsions, and any non-aggressive uid with suf cient lubricating properties. When so required the ACG pump may be certied according to any of following classi cation societies: DNV, BV, LRS, ABS, RS, GL, RINA, KR, NK or CCS. Application Typical applications are: Lubrication of diesel engines, gears, gas and steam turbines, hydro tur bines and paper machines. Circulation for cooling and ltration in large machineries, hy drau lic systems and transformer oil for insulation in transformers. Transfer onboard ships, in oil fac to ries, re feineries, tank farms etc. Fuel supply duties for diesel engines. Discharge pressure Maximum discharge pressure is 16 bar. Displacement cm 3 /r 65 82 103 126 159 193 251 307 359 Design The characteristic of the valve allows the valve The Opti Line ACG pump is a positive displacement pump of 3-screw type. The design basi- not too high demands on pressure modulation to be used as pressure regulating valve when cally meets the requirements of EN ISO 14849. are required. The valve has a maximum set pressure of 16 bar. Pressure relief valve The pump is equipped with an integral pressure relief valve with internal return, limiting the differential pressure across the pump and protecting the pump, should the discharge line be blocked. The valve is adjustable for different opening pressures. The value of the pressure limit can be set at the factory and should be adjusted at in stal la tion (see Installation & Startup instruction for low-pressure pumps). The maximum pressure ackumulation varies with pump size, speed and viscosity, but will normally not exceed 4 bar. 2 Technical data Differential pressure Maximum differential pressure is 16 bar and minimum 1 bar For low viscosity this value is reduced according to the table below. It may also be reduced at high speed/high viscosity related to the pump size and the torque capability of the selected magnetic shaft coupling. Please refer to your IMO representative or use the pump selection software Win- Pump to determine the exact operating limits. Viscosity (cst) 2 7 12 20 30 37 Max. diff. pressure (bar) 5 8 10 12 15 16 Inlet pressure Maximum inlet pressure is 15 bar. Minimum inlet pressure is 0,85 bar, however adjusted upwards related to pump size, operating speed, viscosity and vapor pressure. Please refer to your IMO representative or use the pump selection software WinPump to determine the exact operating limits. Displacement Size, lead 045K 045N 052K 052N 060K 060N 070K 070N 070D www.imo.se Drive The power from motor to the Opti Line ACG pump is transmitted without mechanical contact over a magnetic coupling. A coupling hub with a set of permanent magnets is mounted on the pump shaft. This hub is totally enclosed by a stainless steel can. The motor hub with another set of permanent magnets rotates on the outside of this can. Thus the pumped liquid is totally contained within the pump without the use of a conventional shaft seal. The pump is designed for this type of drive only.

Speed The maximum speed is 3600 rpm. For higher speeds contact your IMO representative. Rotation The ACG pump is designed to operate in one rotational direction only, as standard clockwise when facing the shaft end. For shorter periods of time, a few minutes for emptying a discharge line, the pump may be operated in reverse direction, provided the back pressure is limited to 3 bar. Fluid viscosity 1.6 cst up to 1500 cst. Moment of inertia Moment of inertia, 10 3 kgm 2 Pump with complete coupling Size 045 052 060 070 NHBP 15 16 NJBP 16 17 NKBP 17 17 28 67 NLBP 17 17 28 72 NMBP 19 19 34 78 Mounting attitude The Opti Line ACG pump can be mounted in any attitude. Fluid temperature 20 C up to 180 C. Sound level Typical sound level refers to pump with standard driver and free field conditions at 5 bar, 2950 rpm and 40 cst, measured according to ISO 3741. PumpSize 045 052 060 070 Sound level db(a) 59 63 66 68 Material and design Pump body Power rotor Idler rotors Elastomers Nodular cast iron Steel Perlitic cast iron Viton For handling of fluids that may be aggressive to above materials consult your IMO representative. Viscosity table cst 2 4 8 20 37 75 200 400 800 1500 SSU 32.6 39.2 52.2 99.4 174 346 927 1850 3700 6940 Units The following units are frequently used for specification of pumps: SI unit IMO units USA units conversion Pressure Pa (MPa) bar psi 1 bar = 14.5 psi = 0.1 MPa Speed r/s rpm rpm 1 rpm = 0.016667 r/s Viscosity mm 2 /s cst SSU mm 2 /s = cst (see table) Temperature C C F C = ( F 32)/1.8 Length m mm inch 1 mm = 0.0394 inch Flow rate m 3 /s lit/min GPM 1 lit/min = 0.264 USGPM www.imo.se 3

Performance guide Typical performance values at 5 bar Flow calculated at 26 cst, power at 260 cst For values under other operating conditions, please refer to the IMO AB pump selection software WinPump (download it from www.imo.se and apply for licence). 045K rpm l/min kw form l/min kw form 1470 77 1,5 NJBP 95 1,8 NJBP 1770 97 1,8 NJBP 119 2,2 NJBP 2950 174 3,5 NJBP 216 4,2 NJBP 3550 213 4,4 NJBP 265 5,4 NJBP 052K rpm l/min kw form l/min kw form 1470 125 2,2 NJBP 153 2,7 NKBP 1770 156 2,8 NJBP 191 3,4 NKBP 2950 277 5,3 NKBP 340 6,4 NKBP 3550 339 6,9 NLBP 415 8,0 NKBP 060K rpm l/min kw form l/min kw form 1470 197 3,7 NLBP 240 4,4 NLBP 1770 245 4,6 NLBP 298 5,5 NLBP 2950 432 8,9 NLBP 525 10,5 NLBP 3550 528 11,3 NLBP 641 13,3 NLBP 070K rpm l/min kw form l/min kw form 1470 314 6,6 NKBP 388 7,8 NKBP 1770 389 8,5 NKBP 480 9,9 NKBP 2950 686 16,8 NKBP 843 21,0 NLBP 3550 836 21,8 NKBP 1 027 27,2 NLBP 070D rpm l/min kw form 1470 440 9,7 NLBP 1770 548 12,4 NLBP 2950 971,3 24,7 NLBP 3550 1186,7 32,0 NLBP 045N 052N 060N 070N m3/h 90 80 70 60 50 40 30 20 10 0 045K 045N 052K 052N Flow 060K 060N 070K 070N 070D 1 400 1 200 1 000 800 600 400 200 0 lit/min The performance shown above is calculated at a certain pressure and viscosity. In order to achieve the right selection of pump, magnetic coupling and motor, the IMO AB pump selection program WinPump has to be used. The program can be down loaded free from www.imo.se. 4 www.imo.se

Pump model code Pump series ACG Size (Power rotor diameter, mm) 045, 052, 060, 070 Lead K = Low lead N = Normal lead D = High Lead size 070 Generation Design generation 8 Material in pump body N = Nodular cast iron Magnetic shaft coupling (Size of coupling selected) H, J, K, L, M Mounting B = Flange mounting Valve P = Pressure relief valve included Special design Code group omitted for standard design www.imo.se 5

Pump dimensions 6 www.imo.se

Pump dimensions www.imo.se 7

Sectional view 8 www.imo.se

Sectional view List of components Pos No Denomination 002 Motor 003 Connecting frame 004 Angle bracket 005 Magnetic coupling 005A Retaining ring 006A Screw 007A Screw 007B O ring (106) Balancing 113 Key 122 Ball bearing 124 Retaining ring 124A Support ring 202 Idler rotor 401 Pump body 451 Screw Pos No Denomination 453 Screw 462 Plug 462A Washer 480 Valve housing 5010 Compl. front cover (502) Plug 2 Steel 506 Gasket 514 Retaining ring 556 Gasket 6000 Compl. Valve (601) Valve top cover 602 Washer (605) O ring (608) Valve spindle (608A) Retaining ring Pos No Denomination (612) Regulating nut (614) Valve piston (615) Spring 701 Screw 701A Washer 702 Screw 702A Washer 703 Screw 703A Washer 703B Nut 998 Drive hub 998B Screw Components with Pos No within parenthesis are part of subassembly www.imo.se 9

Installation The Opti Line ACG pump is ange-mounted to an electric motor via a con nect ing frame and a magnetic coupling and has an angle bracket for mounting hor i zon tal ly and vertically, see mounting instructio Maintenance and Ser vi ce Spare parts for these pumps are easily available from stock. For detailed in for ma tion and know-how about service, see the Installation & Service instruction for ACG-pumps or contact your IMO representative. 10 www.imo.se OACE3 1101.01 GB

www.imo.se 11

www.imo.se IMO AB: P. O. Box 42090, SE 126 14 Stockholm, Sweden Telephone: +46 8 50 622 800, Telefax: +46 8 645 1509