Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Similar documents
2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Process Valve/Series VN

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

High Pressure Coolant Valve

Coolant Valve. VNC Series. Cylinder actuation by pilot air

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

3 Port Solenoid Valve Direct Operated Poppet Type

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP3145/3165/3185

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Process Valve/Series VN

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Solenoid Valve

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series VP3145/3165/3185

Steam Valve. Series VND. 2 Port Valve for Steam. With indicator (Option) By adopting of PTFE seal, the valve is suited for steam.

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

VNA VNB SGC SGH VNC VNH VND VCC

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series SV1000/2000/3000/4000

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

3 Port Solenoid Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Direct Air Operated 2 Port Valve/Manifold For Air, Gas, Vacuum and Oil

Series AV2000/3000/4000/5000

3 Port Solenoid Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Impulse Lubricator. Standard Specifications

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

1 1/4 (32A) to 2 (50A) added.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

2 Port Solenoid Valve For Dust Collector

3 Port Direct Operated Poppet Rubber Seal. Standard Continuous duty Energy saving Vacuum Energy saving/vacuum

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Pilot Operated 2 Port Solenoid Valve for Dry Air

Series VXR21/22/23. Water Hammer Relief, Pilot Operated 2 Port Solenoid Valve. For Water and Oil

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Soft Start-up Valve. AV2000/3000/4000/5000 Series

NAMUR Interface 5 Port Solenoid Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

0.35 W (Without light)

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Pilot Operated 2 Port Solenoid Valve for Dry Air

Specifications. Fluid Ambient and fluid temperature ( C)

2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)

Series VQZ1000/2000/3000 Single Unit

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

4F0/1/2/3 Series. Min. working pressure MPa Refer to the individual specifications below to 60 Lubrication Not required (when lubricating,

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

PD3/PDV3-20A/25A/40A Series

Air-hydro Converter CCT Series. Application Example. Multipoint intermediate stops

Transmitters: Relay Valve

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

Series SY3000/5000/7000

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

CVE2/CVSE2 CVE3/CVSE3

Specifications VH600. Ambient temperature and operating fluid temperature Operating angle Lubrication

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more

Vacuum / Release Unit

Compact Proportional Solenoid Valve

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

(Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Rubber Seal VP300/500/700

3-in-1 package (solenoid valve + governor + solenoid valve) realizes compact piping in double shutoff application.

2-Color Display Digital Pressure Switch

Series VQ Port Solenoid Valve

HN B G1/US B G2/US B G3

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Transmitters: Relay Valve VR4151/4152

VXP21/22/23 Series. Pilot Operated 2 Port Solenoid Valve. For Air, Gas, Steam, Water and Oil VX2 VXK VXD VXZ VXS VXB VXE VXP VXR VXH VXF VX3 VXA

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

General purpose direct acting 2, 3 port solenoid valve

Direct Operated 2 Port Solenoid Valve For Water, Oil, Steam, Air

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Transcription:

Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet permits normal and reverse flow. Operation from 0 MPa is possible. Compressed Air Air pressure circuit: Application examples Wide variations N.C., N.O., C.O., types are available. hreaded type from 6A to 50A is standardized. Actuator stop valve Intermediate stop, inching Actuator skip valve erminal deceleration, intermediate deceleration, accelerative start Actuator exhaust valve High speed operation, high speed exhaust Air motor driving valve Air blow valve Line stop valve Main Residual line pressure exhaust valve Main Branch Air-hydro Air pressure circuit: Application examples Operation Capacity When Used in Air-hydro Units Cylinder speed (mm/s) Bore (mm) his series can supplement the capacity of conventional air-hydro valve units. hey are suited to operate large bore cylinders as well as to simultaneously operate multiple cylinders and suspend their operation. hus they can be used in the same way as the conventional air-hydro units. Air-hydro circuit: Application example Basic circuit Conditions Supply 0.49 MPa pressure Hydraulic ISO V3 fluid Load No load Piping m length A, CCVSO Piping diameter A, CCVLO 3/8B (9 mm) /B (3 mm) Piping length 3A 3/4B (9 mm) 4A B (5 mm) Refer to Air-hydro Unit pages in Best Pneumatics No. for further information on air-hydro. When speed controller is mounted Connect a speed controller (Series AS etc.) to A port of (in order to protect the speed control valve from surges when cylinder operation is suspended, thus improving stopping accuracy). Cylinder Speed controller Speed controller Skip valve function Combination of or more valves of Series provides a skip valve function. Connect the skip valve to the A port side of a stop valve. Stop valve Skip valve Stop valve Cylinder Skip valve VNB SC VNC VNH VND VCC Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com 357

Process : Port For Compressed Air and Air-hydro Circuit Control Series How to Order Seal material A NBR seals B FKM seals C EPR seals Refer to able () for availability. solenoid 0 hread type Nil F N A A Bracket ( : //3/4.) Rc Nil None NP B Note) With bracket NPF Note) Only valve s,, 3 and 4. Shipped after assembled at our factory. Bracket part no. : VN-A6 (with thread) s to 4: VN -6 5A to 4 5A type Port Symbol Symbol Orifice dia. 3 Note) (mm) N.C. N.O. C.O. Symbol 6A ø0 8A 0A ø5 0A 5A 3 ø0 0A 4 ø5 5A 5 ø3 3A 6 ø40 40A 7 ø50 50A Note) only Port Rc 8 4 3 4 4 Rated voltage 3 4 5 6 7 9 Option 00 VAC 50/60 Hz 00 VAC 50/60 Hz 0 VAC 50/60 Hz 0 VAC 50/60 Hz 4 VDC VDC 40 VAC 50/60 Hz Other Nil: Non-locking push type B: Slotted locking type B (tool required) Nil: Non-locking push type CE compliant Nil Q CE compliant Electrical entry: D or DZ only A: Non-locking push type A (projecting) to 4 5 to 7 able () Applicable Fluids Fluid 358 A ( material: NBR seal) Air (Standard, Dry) Carbon dioxide (CO) (0.7 MPa Max.) Nitrogen gas (N) urbine oil, Hydraulic fluid Kinematic viscosity 40 to 00 mm /s B ( material: FKM seal) Argon Helium urbine oil Hydraulic fluid 99 C or less C ( material: EPR seal) Carbon dioxide (CO) (0.7 MPa max.) Note) his product cannot be used for water application. Option Electrical entry/with light/surge voltage suppressor Symbol Electrical entry CE compliant rommet S rommet with surge voltage suppressor E rommet terminal EZ rommet terminal with light/surge voltage suppressor Z with light/surge voltage suppressor D DZ with light/surge voltage suppressor rommet S rommet with surge voltage suppressor C Conduit S with surge voltage suppressor Z Note) with light/surge voltage suppressor L Note) with indicator light D DZ with light/surge voltage suppressor DL with indicator light Note) Except rated voltage 6, 7, 9. CE compliant products only Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com to 4 5 to 7

Process : Port For Compressed Air and Air-hydro Circuit Control Series Port Rc Orifice diameter ø (mm) -6A -8A 8 4 0-0A -0A 5-5A 3-0A 3 4 0 Note) his product cannot be used for water application. Flow characteristics Measured by air Measured by water Note) Mass (kg) C [dm 3 / (bar sec) ] 3.5 5.9 7.9 6 3 34 b 0.35 0.4 0.6 0.35 0.5 0.6 Cv Av x 0-6 m 0.88.5.9 3.8 4.8 7.5 5 4 5 0 30 0 0. 0.3 0.5 solenoid 0. 0.4 0.6 4-5A 5-3A 6-40A 7-50A Port Rc 4 Orifice diameter ø (mm) 5 3 40 50 Flow characteristics Cv Effective area (mm) 0 8 30 8 500 43 770 Mass (kg) solenoid 0.8 0.9.3.4.. 3. 3. solenoid Specifications Fluid (Main piping) Refer to able () on page 358. Note ) A 5 to 60 C Fluid Note ) B 5 to 99 C temperature C ( type only) Ambient temperature Proof pressure Operating pressure range Pressure range 5 to 50 C Note ) ( type: 60 C).5 MPa 0 to MPa 0. to 0.7 MPa air Lubrication emperature Not required (Use turbine oil Class ISO V3, if lubricated. Note ) ) 5 to 50 C Note ) ( type: 60 C) Mounting orientation Note 3) Unrestricted Note ) No freezing Note ) Lubrication is not allowed for use with EPR seal material. Note 3) For external solenoid, it is recommended that the solenoid valve be oriented either vertically upward or horizontally. JIS Symbol Style type solenoid N.C. N.O. C.O. Normally closed Normally open Double acting 0 0 03 (P) (P) (P) 0 (P) (P) 0 (P) Pilot Solenoid Specifications Port 6A to 5A 3A to 50A 3A to 50A (CE compliant) Pilot solenoid valve SF4- -3 VO30-00 VO307-00 D DZ-Q Electrical entry rommet, rommet, Conduit rommet terminal Other (Option) Coil rated AC (50/60 Hz) 00 V, 00 V, Other voltage (Option) voltage (V) DC 4 V, Other voltage (Option) Allowable voltage fluctuation emperature rise 5% to +0% of rated voltage 35 C or less 70 C or less 50 C or less (When rated voltage is applied.) (When rated voltage is applied.) (When rated voltage is applied.) 5.6 VA (50 Hz), VA (50 Hz),.7 VA (50 Hz), Inrush Apparent 5.0 VA (60 Hz) 0.5 VA (60 Hz) 0.7 VA (60 Hz) AC power 3.4 VA (50 Hz), 7.5 VA (50 Hz), 7.6 VA (50 Hz), Holding.3 VA (60 Hz) 6 VA (60 Hz) 5.4 VA (60 Hz) Power.8 W (without light), DC consumption W (with light) 4.8 W (without light), 5 W (with light) Non-locking push type Other (Option) Non-locking push type Note) For How to Order solenoid valves, refer to page 363. VNB SC VNC VNH VND VCC Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com 359

Series Construction N.C. N.O. Port (P) Port 0(P) No. 3 Note) 4 Note) 5 6 7 8 Port Component Parts Description Body Cover assembly Plate assembly element Piston assembly ravel spring Return spring Pilot solenoid valve Replacement Parts Port Material Note Aluminum alloy Platinum silver painted Aluminum alloy Platinum silver painted Aluminum alloy material (NBR, FKM, EPR) Aluminum alloy material (NBR, FKM, EPR) Aluminum alloy Stainless steel Piano wire Note) Parts e and r are for selection of valve composition. C.O. type does not have a return spring u. Working Principle Part no. No. Description A 3 4-6A, 8A, 0A -0A, 5A -0A -5A 3 Plate assembly NBR VN-A3AA VN-A3AA VN3-A3AA VN4-A3AA Seal FKM VN-A3AB VN-A3AB VN3-A3AB VN4-A3AB material EPR VN-A3AC VN-A3AC VN3-A3AC VN4-A3AC 4 disc NBR VN-4AA VN-4AA VN3-4AA VN4-A4AA Seal ( disc assembly FKM VN-4AB VN-4AB VN3-4AB VN4-A4AB for 5A-50A) material EPR VN-4AC VN-4AC VN3-4AC VN4-A4AC 8 Pilot solenoid valve SF4- -3 (Refer to page 363 for details.) 0, (N.C.) When the solenoid valve i is not energized (or when air is exhausted from the port (P) of the air operated style), the valve element r linked to the piston t is closed by the return spring u. When valve element opens When the solenoid valve is energized (or when pressurized air enters through the port (P) of the air operated style), the air that has entered under the piston moves upward to open the valve element. When valve element closes When the power to the solenoid valve is turned off (or when fluid is exhausted from the port (P) of the air operated style), the air under the piston is exhausted, and the return spring closes the valve element. 0, (N.C.) In contrast with the N.C., when the power to the solenoid valve is turned off (or when air is exhausted from the port 0(P) of the air operated style), the valve is held open by the return spring. When the solenoid valve is energized (or when pressurized air enters through the port 0(P) of the air operated style), the valve element closes. 03 (C.O.) he valve element of the C.O. type, which has no return spring, is in an arbitrary position when air is exhausted through the ports (P) and 0(P). When pressurized air enters the port (P) (exhaust from the port 0(P)), the valve element opens, and it closes when pressurized air enters the port 0(P) (exhaust from the port (P)). 5-3A VN5-A3AA VN5-A3AB VN5-A3AC VN5-A4AA VN5-A4AB VN5-A4AC 6-40A VN6-A3AA VN6-A3AB VN6-A3AC VN6-A4AA VN6-A4AB VN6-A4AC 7-50A VN7-A3AA VN7-A3AB VN7-A3AC VN7-A4AA VN7-A4AB VN7-A4AC VO30-00 (Refer to page 363 for details.) 360 Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com

Process : Port For Compressed Air and Air-hydro Circuit Control Series Port : 6A, 8A, 0A Applicable cable O.D. ø6 to ø8 (D.) Pilot port (P) x Rc /8 (Back side 0 (P)) (Non-locking push type) 7 (: : D) 08. (rommet terminal: E) 06.7 (rommet: ) 63 () Pg.9 Main port (Back side ) Port : refer to table below 65 (rommet terminal: E) 70 (: ) 74.5 (: D) Bracket x ø4.5 x M4 x 0.7 depth 7-6A -8A -0A Main port, 8 4 In the case of EZ or Z, the length is longer by 0 mm. For DZ, the length is longer by 7 mm. VNB SC VNC VNH VND VCC Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com 36

Series Port : 0A, 5A, 0A, 5A Applicable cable O.D. ø6 to ø8 (D.) (Non-locking push type) Pilot port (P) x Rc /8 (Back side 0 (P)) L (: : D) K (rommet terminal: E) J (rommet: ) 4 x øp F () Pg.9 Main port (Back side ) Port : refer to table below (rommet terminal: E) H (: ) I (: D) In the case of EZ or Z, the length is longer by 0 mm. For DZ, the length is longer by 7 mm. -0A -5A 3-0A 4-5A Main port, 3 4 A B C D E F H I J K L M N P Q R S U 63 80 90 4 50 60 8 35 40 4 7.5 0 7.5 84 00 80.5 9 08 75 84 90 80 89 95 84.5 93.5 99.5 4 35.5 5.5 5.5 37 53 44.5 56 7 5 6 7 6 3 36 4.5 5.5 6.5 4.3 8.3 33.3.3.3.3 5 30 35 34 43 49 55 60.5 73 Port : 3A, 40A, 50A Applicable cable O.D. ø6 to ø8 (D, DL) Pilot port (P), 0(P) L (: ) K (erminal with indicator light: DL) J (: D) I (Conduit: C) H (rommet: ) () (Non-locking push type) Main port (Back side ) Port : refer to table below Main port Pilot port, (P), 0(P) 5-3A 6-40A 7-50A 4 8 4 4 Note) ( ): CE compliant product (-Q) 36 A 05 0 40 B 77 96 3 C 53 60 74 D 6.5 30 37 E 0.5 37 60 F 0 4 4 9.5 47 70 H 63 80.5 03.5 I 75.5 93 6 J Note) 9 (5.5) 36 (33) 59 (56) Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com K 3 40.5 63.5 L 9.5 47 70 M 55 63 74

Process : Port For Compressed Air and Air-hydro Circuit Control Series How to Order Pilot Solenoid s //3/4 5/6/7 SF4 DZ 3 Coil rated voltage 00 VAC 50/60 Hz 00 VAC 50/60 Hz 3 0 VAC 50/60 Hz 4 0 VAC 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC 50/60 Hz 9 Other Semi-standard S E EZ Z D DZ Nil Non-locking push type Non-locking push A type A (projecting) Slotted locking B type B (tool required) Semi-standard Electrical entry/ With light/surge voltage suppressor rommet rommet with surge voltage suppressor rommet terminal rommet terminal with light/surge voltage suppressor with light/surge voltage suppressor with light/surge voltage suppressor VO307 00 VO30 00 Coil rated voltage 00 VAC 50/60 Hz 00 VAC 50/60 Hz 3 0 VAC 50/60 Hz 4 0 VAC 50/60 Hz 5 4 VDC 6 VDC 7 40 VAC 50/60 Hz 9 Other Semi-standard Q CE compliant Electrical entry rommet C Conduit Note ) D With surge voltage suppressor Nil None Surge voltage suppressor S (Except DZ, DL ) CE compliant with light/ DZ surge voltage suppressor DL Note ) with indicator light Note ) When the electrical entry is, the solenoid valve parts are as follows; VO30-00 -X30 Light/Surge voltage Suppressor Coil rated voltage Note ) Semi-standard CE compliant products only Accessory Function plate for VO30 (D seal, with screw): DX060-3-4A Function plate for VO307 (D seal, with screw): DX5-4-A VNB SC VNC VNH VND VCC Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com 363

Series Specific Product Precautions Be sure to read before handling. Refer to front matters 4 and 43 for Safety Instructions, and pages 7 to 9 for Port Solenoid s for Fluid Control Precautions. Pilot. Pilot port piping (P) and 0(P) piping should be as follows according to the model Port (P) 0 (P) 0 Bleed port 0 03 Bleed port Pilot exhaust Installing a silencer to the exhaust port and the bleed port is recommended for noise reduction and for dust entry prevention. Piping When high temperature fluids are used, use fittings and tubing with heat resistant features. (Self-align fittings, eflon tubing, Copper tubing, etc.) Mounting Direction of Pilot Solenoid Warning With external solenoids, the solenoid valves are not splash proof specifications, and so care must be taken not to get fluid on oneself such as when performing maintenance. Direction of mounting When replacing a valve, if an external solenoid valve is mounted in the wrong direction, it may malfunction or leak air. Use with Air-hydro Unit. Piping Surge pressure is generated between the cylinder and the during intermediate stoppage. o directly thread in the cylinder, use durable fittings (Stainless steel square nipples etc,) instead of ductile iron fittings (JIS B 30) or steel pipe fittings (JIS B 30). When is installed away from the cylinder, use a high-pressure rubber hose (JIS B 6349) instead of steel pipe, when possible.. Air bleeding Series valves have no air bleeding port. Bleed air comes from the middle piping. Bleeding by a vacuum pump is more effective.. Hydraulic fluid urbine oil, rade ISO V3, with petroleum hydraulic fluid is recommended. 3. Speed control valve he combination shown in the following table is recommended for best performance of the Series. (Piping: JIS K 6349 high pressure hose) Combination between Series- and Speed control valve (Series AS) 0A 5A 0A 5A 3A 40A 50A 3 4 5 6 7 AS 40-03 40-04 500-06 600-0 800-900-4 900-0 Piping (I.D.) B (ø9.5) B (ø.7) 3 4 B (ø9.) B (ø5.4) 4 B (ø3.8) B (ø38.) B (ø50.8) 364 Courtesy of Steven Engineering, Inc.-30 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com