Contents. 1. Preface Change record Fuse Replacement...5. MPU fuses...5

Similar documents
How to get started. with. Kongsberg XP Auto systems. Serial number: Please Read This First

Nota Conductor s Chair

Music Stands CONTENTS. Assembly and Owner s Manual. Note: Note:

SKF Belt Tension System. The SKF way to support transmission Easy Quick Repeatable

6170 Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

TLT. Standards. Telescopic pillar. Very small built-in dimension EN/IEC UL Powerful

Rectangular Door L-VAT with pneumatic actuator double acting

RECHARGE STATION OPERATION MANUAL. Version

BLY17MDA-2W Series. 24V, 10A Brushless Controller/Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Linear actuator CAHM-31. Benefits. Modular Robust Reliable High speed and/or high load All metal design. Picture CAHM-3130-LS0300-D1-010

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

MBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA

TM4500. Track Mounted Step Motor Driver. User s Guide. CE Certified and RoHS Compliant #L010060

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

MBDC V, 30A Brush Controller. User s Guide E. Landon Drive Anaheim, CA

MANITOWOC (Crawler Mount) LOAD CHART

Installation, Operating & Maintenance Instructions. Hot surfaces; do not touch!

Universal Battery Holder Operator s Manual

Electronic lubrication control unit

Flushing Instruction

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

DPD72001, DPD Unipolar Step Motor Driver. User s Guide E. Landon Drive Anaheim, CA

MDC Series

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

3000 Series Operation Manual

Microscope light manual

Metric dovetail slides. A selection of sizes for tooling, work feeding and positioning operations

Mini UHV gate valve with manual actuator with pneumatic actuator

DPS32001 and DPS32PS1

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

Control Gate Valve with stepper motor actuator

DPBHV001, DPZHV002. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

INSTRUCTIONS: JOEY 30 CART (MK2)

M2004. Document ID: 3HAC Revision: - Copyright 2010 ABB. All rights reserved.

Linear actuator CAR 32. Benefits. Industrial reliable and robust actuator Wide range of components Right- and left-hand version

Wenger Corporation 2011 Printed in USA 08/11 Part #158E006-02

Block feeder SPVS Used in oil or grease lubrication systems

MBC01081 Series. Bipolar Microstep Driver. User s Guide E. Landon Drive Anaheim, CA

UHV Angle valve (Series 284) with pneumatic actuator, single acting with closing spring (NC)

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

Assembly Instructions Signature Choral Riser 3-Step Model

Wall mount PMV pump with suction kits and hoses

SUPER PUMP OUT SYSTEM

Block feeder SPVS Used in oil or grease lubrication systems

BLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA

DC Distribution Panel User Guide # S

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

SKF Explorer cylindrical roller bearings. Extended range for large, heavy industrial applications

BLD75-1. Bilevel Step Motor Driver. User s Guide. 910 East Orangefair Lane, Anaheim, CA

BLY17MDA Series. 24V, 10A Brushless Controller/Motor. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

ARM. series SIGNUM SYSTEMS CORPORATION. ARM Board Setup. User Guide

OnBoard Drum Major Podium

Toro Sprayer Calibration Tool

USER'S MANUAL MODEL DPD60001 MICROSTEP DRIVER PACK

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Telescopic pillar. For infant care CPMB. Benefits. Standards

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide E. Landon Drive Anaheim, CA

BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor

LINK-BELT (Rough Terrain) LOAD CHART

MDCSL V, 30A

Bearing designs. Spherical roller bearings. Extract from the Railway technical handbook, volume 1, chapter 4, page 96 to 98

MBL600 Bilevel Step Motor Driver

Contactor Combiner Box Installation Manual

ABB Robotics. Product manual, spare parts IRB 6640

Linear actuator CAT 33. Benefits. Small Robust Highly efficient Lubricated for service life Digital encoder feedback

HV-Angle Valve (Series 264) HV-InlineValve (Series 265) with electromagnetic actuator single acting with closing spring (NC)

Universal Deck & Rail Cart

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

MBDC Series

AN RPM to TACH Counts Conversion. 1 Preface. 2 Audience. 3 Overview. 4 References

FOG FURY FAZE. User Instructions

Do-It-Yourself Battery Pack

abc INSTALLATION, OPERATION, & MAINTENANCE MANUAL ADDENDA 210 MKII LOW TEMPERATURE CELL SAMPLER

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

BroadBand PowerShield. 20 AHr Battery. User Manual

Disconnect Combiner Box Installation Manual

LINK-BELT. These charts are not to be used for any other purpose. LOAD CHARTS for Use in CCO Written Examinations

victron energy B L U E P O W E R

BSC Series

MDC Series

MDC Series

Inexpensive solution for the lubrication of linear guides and rolling bearings

RM40, GMD40, RMD40, RMDG40 Sample Transporter DN40CF. Instruction Manual

Detailed Specifications & Technical Data

Air and water reels. Models and Series B. Installation and maintenance guide DANGER

Mechanical Spiral Sensor

PARTS BOOK ROTARY HEADS 50 CUT, INDIRECT DRIVE BOOM MOUNT

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

Installation Manual uniflow Gen. Budget Connector for ibos

Models P, P, P, , DANGER

HV Angle valve (Series 264) HV Inline valve (Series 265) with pneumatic actuator, single acting with closing spring (NC)

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Operators Manual. FHX Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 07/2017

AWRF Associated Wire Rope Fabricators

Transcription:

Fuse Replacement

Contents 1. Preface... 2. Change record...4. Fuse Replacement...5.1.2..4.5.6.7 ii MPU fuses...5 X1 fuses...6 X2 fuses...7 Y/Z fuses...8 Tool Rotation/Reciprocating knife fuses...9 Chiller fuse... 9 Heater for Chiller Fuse...11

1. Preface Fuse Replacement Manual for Kongsberg Note: We remind you that only the Esko Staff, or persons having received appropriate training, are allowed to handle, manipulate or do repairs on the system. Note: Information about fuse replacement is available also from the User Manual for. Copyright 2014, Esko-Graphics Kongsberg AS, Norway All Rights Reserved. This copyright does not indicate that this work has been published. This material, information and instructions for use contained herein are the property of EskoGraphics Kongsberg AS. There are no warranties granted or extended by this document. Furthermore, Esko-Graphics Kongsberg AS does not warrant, guarantee or make any representations regarding the use, or the results of the use of the system or the information contained herein. Esko-Graphics Kongsberg AS shall not be liable for any direct, indirect, consequential or incidental damages arising out of the use or inability to use the system or the information contained herein. The information contained herein is subject to change without notice. Revisions may be issued from time to time to advise of such changes and/or additions. No part of this system may be reproduced, stored in a data base or retrieval system, or published, in any form or in any way, electronically, mechanically, by print, photoprint, microfilm or any other means without prior written permission from Esko-Graphics Kongsberg AS. This document supersedes all previous dated versions. Correspondence regarding this publication should be forwarded to: Global support Esko-Graphics Kongsberg AS Document no: D50 Esko-Graphics Kongsberg AS www.esko.com P.O.Box 1016, N-601 Kongsberg, Norway Tel: +47 2 28 99 00 Fax: +47 2 28 85 15 / 2 28 67 6 1

2 2. Change record 4 Date By Description 29-11-201 jhbe Version 1

. Fuse Replacement Before starting the Fuse Replacement procedure: Switch Power Off using the Main Power Switch Remove the Main Power plug from the wall socket Note: Some of the equipment described here is optional..1 MPU fuses MPU Location Note: MPU location is model dependent. All fuses are located on the rear side of the Main Power Unit (MPU). Fuse Location 5

Procedure 1. 2.. 4. 5. 6. Remove frame cover in front of MPU Remove the metal shield covering F1/F2, F24/F48. Remove one fuse, check with ohm meter. If blown, replace with a new, identical fuse. Repeat for each fuse. Replace base cover. Insert main power cable into the wall socket and turn main power ON Fuse Details Fuse location F1 and F2, line fuses F24, +24V fuse F48, 48V Servo power fuse.2 X1 fuses X1 Amplifier Location Fuse Location 1 SCU unit 2 6/12A amplifier X1 6 115V T 10A 250V (5x20 mm) T 6,A 250V (5x20 mm) T 15A 250V (5x20 mm) 20V T 5A 250V (5x20 mm) T 6,A 250V (5x20 mm) T 15A 250V (5x20 mm)

Procedure 1. 2.. 4. Remove X1 cover. Check the X1 fuse with ohm - meter. If blown, replace with a new, identical fuse. Replace covers. Insert main power cable into the wall socket and turn main power ON. Fuse Details T 8A 250V 1 1/4 x 1/4 in. (6, x 2 mm). X2 fuses X2 Amplifier Location Fuse Location 1 6/12A amplifier X2. Procedure 1. Remove X2 cover. 2. Check the X2 fuse with ohm - meter. If blown, replace with a new, identical fuse. 7

. Replace covers. 4. Insert main power cable into the wall socket and turn main power ON. Fuse Details T 8A 250V 1 1/4 x 1/4 in. (6, x 2 mm).4 Y/Z fuses Y Amplifier Location Fuse Location 1 Y-amplifier unit 2 TCU Z-axis motor Procedure 1. 2.. 4. 8 Remove Y cover. Check the Y and Z fuse with ohm - meter. If blown, replace with a new, identical fuse. Replace covers. Insert main power cable into the wall socket and turn main power ON.

Fuse Details Y: T 8A 250V 1 1/4 x 1/4 in. (6, x 2 mm) Z: T 4A 250V 1 1/4 x 1/4 in. (6, x 2 mm).5 Tool Rotation/Reciprocating knife fuses Fuse Location Procedure 1. Fuses are available from beneath the Toolhead cover. 2. Remove fuse F9 or F10 and check with ohm - meter. If blown, replace with a new identical fuse.. Insert main power cable into the wall socket and turn main power ON. Fuse Details F9: T 2A 250V 1 1/4 x 1/4 in (6, x 2 mm) F10: T 2A 250V 1 1/4 x 1/4 in (6, x 2 mm).6 Chiller fuse 9

Remove the on/off button Remove cover (4 screws) Fuse location Pull out the fuse holder Turn the fuse holder 90 deg. Now you have easy access to the fuse. 1 - Spare fuse 2 - Fuse in action Fuse: T 1A 250V (5x20 mm) 10

.7 Heater for Chiller Fuse Heater Fuse Location The Fuse is available inside the connector cover. Fuse details F - 4A 250V T 5x20mm Slow Blow (42448944) 11