Battery, Testing, Charging Using Midtronics MCR340V Battery Analyzer or InCharge 940 (INC-940) Battery Charging Station

Similar documents
Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

BBT-205. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

MDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

Mazda North American Operations Irvine, CA MULTI-MODEL - BATTERY TEST PROCEDURE REQUIREMENTS USING THE GR BULLETIN NOTE

MDX-653P INSTRUCTION MANUAL. Battery Conductance and Electrical System Analyzer

Drivetrain Binding/Tires Scrubbing During Low Speed Maneuvering, ESP Light in Instrument Cluster ON or Flashing

MDX-645P INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

Previous versions of this TSB should be discarded. TSB UPDATE NOTICE: The information contained in this TSB supersedes TSB No. PG

MDX-700P HD INSTRUCTION MANUAL. Battery Conductance and Electrical System Analyzer

Bulletins - SI/MI - ( ) Battery maintenance program

BVA-460 Operator's Manual

Gary Mackey National Sales Manager Associated Equipment Corporation

DESCRIPTION & OPERATION

Generator: All Technical Service Bulletins Charging System - No Start/Generator Lamp Flashing Group: 27

R230 Dual Battery On-board Electrical System. 218 HO Dual Battery (ACB)

TECHNICAL SERVICE BULLETIN

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

Title: M.I.L. ON DTC P3191, P3190, AND/OR P0A0F Models:

User s Manual. Automatic Switch-Mode Battery Charger

MDX-640 MDX-640 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:


INTRODUCTION OF A HANDS-ON BATTERY AND SYSTEM ANALYZER. CONDUCTANCE PROFILING TM Where did the need come from?

2/2/2018 Feed Circuit Test (Starting System) - ALLDATA

2007 Dodge Nitro R/T ENGINE Starting - Service Information - Nitro. Starting - Service Information - Nitro

Heavy-Duty Battery and Electrical System Diagnostic Tester

VAS 6161 INSTRUCTION MANUAL. Vehicle Battery and Electrical Diagnostic Platform

Battery Cut-Off Switch, Disconnecting and Removing During the Pre-Delivery Inspection (PDI) 2004, 2005

Don't just Perform Service - Sell It!

DSS-7000 INSTRUCTION MANUAL. Battery Diagnostic Service System. For testing 6- and 12-volt automotive and 12-volt and 24-volt charging systems.

# : SMU - Revised DTC P0341 Camshaft Position (CMP) Sensor Performance - (Feb 20, 2002)

Service Bulletin

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Service Bulletin

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

BATTERY & STARTER ANALYSER (BSA-12) User Manual

TABLE OF CONTENTS. Page 1

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To > 2004 All All All All > 2004 All All All All

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

AUTO CHARGE LPC SERIES

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

DIGITAL BATTERY TESTER 12V

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To All All All All

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

SPN 609 or Suspect Parameter Number (SPN) and Failure Mode Indicator (FMI) Description

1 of 8 9/11/2015 3:59 PM

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To. All All All

Power Sliding Door (PSD) Diagnostic Approach. Fixing Intermittent Malfunctions. Power Sliding Door (PSD) Diagnostic Information

BVA-350 Operator s Manual

Disclaimer. Safety Precautions and Warnings. NexBat NB300 12V Battery Analyzer

BVA-230 Operator's Manual

00 02 Apr. 24, Service

6.7L Diesel Fuel Conditioning Module

Sedan Range. Incorrect Fuel Gauge Reading Diagnosis of Fuel Level Sender Unit

STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS

STARTING SYSTEM TEST STARTING SYSTEM

BATTERY TESTER ANALYZER

SCHEMATIC AND ROUTING DIAGRAMS

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To. Passat Wagon 2007 BPY (2.0L) All 3C_7E C_7E051587

SB-300 Operator s Manual

LOW TIRE PRESSURE WARNING SYSTEM; BULLETINS SUMMARY

ElPower script. Contents. ElPower script diagnostics of the engine starting and charging system

SP6. Automatic Battery Charger. Model

EXP-1003 HD INSTRUCTION MANUAL. Expandable Electrical Diagnostic Platform

9/11/2017 General Information (12) > [BOD051] Service Action: Power Tailgate IPM Update To Prevent Battery Discharge 2006 Kia Sedona MotoLogic

IMPORTANT SAFETY INSTRUCTIONS

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Tips & Technology For Bosch business partners

Technical Service BULLETIN

Service Bulletin Product Update: Moisture in Headlight. March 10, WARRANTY CLAIM INFORMATION In warranty: The normal warranty applies.

PSJ-2212, PSJ-3612, PSJ-4424

CHARGING SYSTEM SECTION CHG CONTENTS ELECTRICAL & POWER CONTROL CHG-1 PRECAUTION... 3 WIRING DIAGRAM... 9 BASIC INSPECTION...13 PREPARATION...

4.0L CEC SYSTEM Jeep Cherokee DESCRIPTION OPERATION FUEL CONTROL DATA SENSORS & SWITCHES

Models: SP3, SPSS3 Automatic Battery Charger

TECHNICAL SERVICE BULLETIN

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Service Bulletin

Service Bulletin

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

4/24/2014 ALLDATA Repair Toyota Truck Tacoma PreRunner V6-4.0L (1GR-FE) - Tire Pressure Monitor - Sensing Transmitter Activation

DSS-7000 INSTRUCTION MANUAL. Midtronics Battery Diagnostic Service System

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

Powertrain DTC Summaries EOBD

Table of Contents. Chapter 1 Product Summary... 2

FUNCTION SELECTION. Check the Trouble Code SCAN-100. Preceding Work: Perform the Entering Diagnosis Procedures

Udiag BST300 Battery Tester User Manual

Technical Service Bulletin

PTI900X PST-900X. Battery Tester with Printer. For 6 and 12 Volt batteries and 24 Volt charging systems OWNERS MANUAL

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Service Bulletin

AUTO CHARGE 1200 PUMP PLUS

Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To 2.0L TDI (CBEA) 2.0L TDI (CJAA) 2.0L TDI (CJAA) 2.0L TDI (CJAA)

AUTO CHARGE D PUMP PLUS

Service Bulletin

Powertrain DTC Summaries OBD II

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Transcription:

Condition Battery, Testing, Charging Using Midtronics MCR340V Battery Analyzer or InCharge 940 (INC-940) Battery Charging Station 27 06 05 Oct. 6, 2006, 2012377, Supersedes Technical Bulletin Group 27 number 04-01 dated Sept. 1, 2004 due to additional models and information. Model(s) Year Eng. Code Trans. Code VIN Range From VIN Range To Touareg 2004 > 2007 All All All All Technical Background The Midtronics MCR340V and InCharge 940 are the only approved VW battery testers and chargers that can be used to test and charge batteries in VW vehicles. The use of non-approved battery testers and chargers is not allowed since damage may occur to the battery internally. Production Solution No production change required. Page 1 of 7

Service WARNING Danger of injury! Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for leadacid batteries. Note: In order to prevent damage to the battery or vehicle, observe battery type descriptions and notes. Switch off all electrical consumers. Switch ignition OFF and remove ignition key. Testing/charging directly at battery Do not remove battery from the vehicle to test the battery; always test battery in the vehicle except for the following conditions: - Battery was removed for a separate repair prior to performing the battery test. - Over the counter parts. When testing or charging battery either installed or removed from vehicle: Single Battery System - 3.2L, 3.6L, and 4.2L Engines Start/Accessory battery Select Standard (Lead-Acid) for 3.2L, 3.6L, and 4.2L engines (located under driver's seat). 450 DIN* * Always verify using DIN rating as shown on battery label. Page 2 of 7

Dual Battery System - 5.0L (TDI) Engine Accessory battery Select Standard (Lead-Acid) for 5.0L (TDI) engine (located under driver's seat). 520 DIN* * Always verify using DIN rating as shown on battery label. Starter battery Select AGM (Absorbed Glass Mat) for 5.0L (TDI) engine (located under spare tire). 480 DIN* or 520 DIN* * Always verify using DIN rating as shown on battery label. Always use actual DIN rating as shown on battery label -arrow-. Label shown is for example only. DIN or SAE specifications may vary from battery to battery. Page 3 of 7

If DIN rating is not shown: Use SAE value as printed on the battery label. If using the SAE value rating: The Midtronics tester menu option must be changed to achieve accurate results. The change from DIN to SAE can be made from the Other menu option on the Midtronics tester. Testing/charging from remote location (Reduced DIN rating requirement) When using remote location terminals -arrows-, located in the engine compartment, always reduce DIN rating on MCR340V or INC-940 testers. 3.2L, 3.6L, and 4.2L engines: 270 DIN. 5.0L (TDI) engine: 295 DIN. The use of these reduced DIN ratings are required to compensate for the internal battery manager and/or the extended length of cable due to the battery location. MCR 340V and INC-940 displays "System Noise" at beginning of battery test The MCR 340V and INC-940 may display "System Noise" at beginning of battery test, whether testing directly at battery or at remove location. This is an infrequent and a normal message which may be caused by: - Battery monitoring control module. - Ignition left in "ON" position. - Accessories or loads turned ON in vehicle with key in "ON" position. - Loads running with the ignition in the "OFF" position such as: the cooling fan or after-run coolant pump. - Aftermarket equipment (ipod (due to improper installation), Lojack, remote starters, televisions, lighting, etc.) Page 4 of 7

This may be overcome by verifying: - Ignition is in "OFF" position. - All loads (cooling fan or after-run coolant pump) are OFF prior to testing. - Any aftermarket equipment is disconnected from the vehicle's electrical system. Wait a few minutes, then retest again. If test was executed at remote location and condition persists, retest directly at battery. Battery testing results: Midtronics MCR340V Battery Analyzer vs. INC-940 Battery Charging Station In some cases, when testing a battery using the MCR340V tester: Test results may be Good Battery - Recharge. However, when attempting to charge the same battery with INC-940 Charger: Results may be to Replace Battery either after testing or during the charging process. This is normal since both MCR 340V and INC 940 use a conductance test, but the INC 940 also incorporates the use of a 150A load test and sophisticated charging algorithm which monitors the charging state of the battery. In this case, the results of INC 940 should always be used instead of MCR340V. Charging system test results at battery: Low Charging Voltage using the Midtronics MCR 340V Battery Analyzer If performing a charging system test with Midtronics MCR340V tester directly at the battery: Test results may be Problem Low Charging Voltage. This result may be due to a faulty generator, however, do not automatically assume that the generator is faulty. Since the MCR340V is connected at the battery, the low charging voltage could be due to excessive voltage drop on the generator battery cable, poor connections, contaminated or faulty grounds in the charging system. To deem the generator faulty: Verify charging voltage and current output, directly at generator, using the 5051 measurement tools functions. Test generator at the back or as close as possible to achieve accurate results. Failure to properly diagnose the issue may lead to the replacement of unnecessary parts which could result in a denied warranty claim. Page 5 of 7

Charging system test for dual batteries using the MCR340V When performing the charging system test, using the MCR340V, perform it at either battery using the 5051B measurement tool. Charging system test results at remote location: Excess Ripple Detected using the Midtronics MCR340V Battery Analyzer If performing a charging system test with Midtronics MCR340V tester at remote location terminal: Test results may be Problem - Excess Ripple Detected. This result may be due to periodic system noise in the vehicle s electronics system or possible low battery voltage. To ensure test results are accurate: Always retest directly at battery and perform any action as directed by Midtronics tester (good, recharge or replace). Perform charging system test again at battery. Battery testing/charging: INC-940 Battery Charging Station -Automatic Mode- When using INC-940 Battery Charging Station in Automatic Mode and testing or charging a deeply discharged battery: INC-940 may continuously display a message Are clamps connected? In order to test battery: Manually charge battery for 30 minutes and perform test again. Battery testing/charging: INC-940 Battery Charging Station -Manual Mode- When using INC-940 Battery Charging Station in Manual Mode and testing or charging a deeply discharged battery: INC-940 may display a message Are clamps connected? twice. This is not a result of defective INC-940 test equipment, but is a safety feature of the INC-940 to ensure cables are connected to the battery before power is turned ON. INC-940 Battery Charging Station always displays Check Connections The INC 940 may always display the message to Check Connections after cables are connected to the battery terminals. This is most likely due to the sensing probe making contact with the clamp. Page 6 of 7

There is one sensing probe on each clamp, (+) and (-), make sure to check both! There must be no contact between the inside connection and the outside jaw of the clamp, -arrows- as shown. Inside connection is bent and touching the outside of the clamp, - arrows- as shown. If the clamp is incorrect: Use a small flat tool and gently bend the sensing probe so it does not make contact with the clamp. If this does not resolve the issue: Contact Midtronics Corporation Customer Service Department at 1-800-776-1995 for assistance. Warranty Information only. Required Parts and Tools No Special Tools required. Page 7 of 7